HP4-DC48V [NAIS]
10 AMP POWER RELAY; 10 AMP功率继电器型号: | HP4-DC48V |
厂家: | NAIS(MATSUSHITA ELECTRIC WORKS) |
描述: | 10 AMP POWER RELAY |
文件: | 总11页 (文件大小:374K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VDE
2c, 3c
10 AMP POWER RELAY
FEATURES
HP-RELAYS
25
.984
36
1.417
• Interchangeable with existing models
• Long life and high reliability
44.5
1.752
• High contact capacity up to 10 A 250 V AC
• Available with plug-in/solder and quick-connect terminals
mm inch
SPECIFICATIONS (at 20°C 68°F)
Contacts
Characteristics (at 60 Hz, 20°C 68°F)
Arrangement
2 Form C 3 Form C 4 Form C
15 mΩ
2 Form C 3 Form C 4 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Maximum operating speed
Initial insulation resistance*1
20 cpm
more than 100 MΩ at 500 V DC
Silver
alloy
Between open
contacts
1,000
Vrms
2,000
Vrms
1,000
Vrms
Contact material
Silver
Nominal switching
capacity
Breakdown
voltage*2
1,500
Vrms
2,000
Vrms
1,500
Vrms
Rating
10 A 250 V AC (resistive)
Between contact sets
Remarks
Between contact and
coil
1,500
Vrms
2,000
Vrms
1,500
Vrms
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "initial breakdown voltage" section
*2 Detection current; 10 mA
Approx.
15 ms
Operate time*3 (at nominal voltage)
Approx. 25 ms
Approx. 25 ms
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Release time (without diode)*3
(at nominal voltage)
Approx.
15 ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Temperature rise
Max. 65°C
98 m/s2 {10 G}
Functional*4
Destructive*5
Shock resistance
980 m/s2 {100 G}
58.8 m/s2 {6 G}, 10 to 55 Hz
at 1 mm double amplitude
117.6 m/s2 {12 G}, 10 to 55 Hz
at 2 mm double amplitude
Functional*6
Vibration resistance
Destructive
Conditions for opera-
Ambient
–50°C to +40°C
–58°F to +104°F
tion, transport and
temp.
storage*7
(Not freezing and
condensing at low
temperature)
Humidity
5 to 85% R.H.
Approx.
60g
Approx.
100g
Approx.
125g
Unit weight
2.12 oz
3.53 oz
4.41 oz
LIFE DATA
Contact rating and expected life For AC load type
Voltage
Load
125 V AC
250 V AC
Expected life
(min. operations)
Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4) Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4)
—
10 A
5 A
1A
—
7.5 A
10 A
7.5 A
3 A
7.5 A
5 A
2×105
5×105
1×106
2×106
1×107
Electrical
life
Current
3 A
2 A
0.7 A
0.6 A
0.4 A
Mechanical life
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
411
HP
Contact rating and expected life For DC load type
Voltage
Load
24 V DC
125 V DC
Expected life
(min. operations)
Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4)
Resistive (cosϕ ] 1)
Inductive (cos ϕ ] 0.4)
—
7.5 A
5 A
7 A
5 A
—
—
2×105
5×105
1×106
2×106
1×107
Electrical
life
0.5 A
0.3 A
0.1 A
0.4 A
0.2 A
0.06 A
Current
3 A
1A
0.6 A
Mechanical life
Life curve
Notes:
1. For DC inductive loads, use an arc suppress-
ing circuit.
1,000
900
800
700
600
500
400
300
200
100
0
Mechanical life
more than 10,000,000
operations
2. When used under a DC load operating at
high repetition rate with considerable arcing,
corrosion of the contacts and/or the contact
blades is likely to occur. When using the relay
under conditions of high temperature, humidity
or high repetition rate, it is suggested that the
relay cover be removed to facilitate extended
operation.
5
10
Load current, A
TYPICAL APPLICATIONS
HP relays enjoy wide use in various appli-
cations, particularly in automation con-
trols and remote controls.
Machine tool
Food processing packing machines
Office equipment
Transportation
Communication and measuring devices
Amusement devices
Applications include:
Industrial machinery
Coin operate devices
Home appliances
ORDERING INFORMATION
Ex. HP
3
M
AC240V
Contact arrangement
Terminal
Coil voltage
2: 2 Form C
3: 3 Form C
4: 4 Form C
Nil: Standard plug-in terminal
AC 6, 12, 24, 48,
115, 220, 240 V
DC 6, 12, 24, 48,
110 V
M: Direct mounting (3 Form C only)
TM: Top mounting (2 Form C only)
L: Lamp wired, standard plug-in terminal
(Notes) 1. For UL/CSA or VDE recognized types, add suffix UL/CSA or VDE (HP2-TM type VDE application under way)
2. Standard packing Carton: 50 pcs. Case: 200 pcs.
3. UL/CSA approved type is standard.
TYPES AND COIL DATA
1. Standard plug-in terminal type (without lamp wired)
DC TYPES at 20°C 68°F
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Max.
allowable
voltage, V DC
Coil
resistance,
Ω (±10%)
Nominal
operating
power, W
Nominal coil
voltage, V DC
Nominal coil
current, mA
Type
Part No.
HP2-DC6V
6
12
24
48
110
6
4.8
9.6
0.9
1.8
3.6
7.2
16.5
0.9
1.8
3.6
7.2
16.5
0.9
1.8
3.6
7.2
16.5
6.6
13.2
26.4
52.8
121
6.6
25
110
240
109
54.5
26.7
15.0
250
120
60
1.5
1.3
1.3
1.3
1.7
1.5
1.4
1.4
1.5
1.6
1.6
1.5
1.5
1.5
1.7
HP2-DC12V
HP2-DC24V
HP2-DC48V
HP2-DC110V
HP3-DC6V
2 Form C
19.2
38.4
88
440
1,800
7,300
24
4.8
HP3-DC12V
HP3-DC24V
HP3-DC48V
HP3-DC110V
HP4-DC6V
12
24
48
110
6
9.6
13.2
26.4
52.8
121
6.6
100
3 Form C
4 Form C
19.2
38.4
88
400
1,560
7,450
22
31
14.9
273
127
63
4.8
HP4-DC12V
HP4-DC24V
HP4-DC48V
HP4-DC110V
12
24
48
110
9.6
13.2
26.4
52.8
121
95
19.2
38.4
88
380
1,500
7,000
32
15.7
412
HP
AC TYPE (50/60 Hz) at 60 Hz, 20°C 68°F
Pick-up
voltage,
V AC (max.)
Drop-out
voltage,
V AC (min.)
Max.
allowable
voltage, V AC
Nominal
operating
power, VA
Nominal coil
voltage, V AC
Inductance,
H
Nominal coil
current, mA
Type
Part No.
HP2-AC6V
6
4.8
9.6
1.8
3.6
7.2
14.4
34.5
66
6.6
13.2
26.4
52.8
126.5
242
0.049
0.190
0.776
3.106
15.83
57.90
66.26
0.030
0.119
0.475
1.899
10.36
39.32
44.05
0.019
0.077
0.309
1.292
6.953
26.57
29.75
310
160
78
1.9
1.9
1.9
1.9
2.1
2.1
2.2
3.1
3.1
3.1
3.1
3.3
3.1
3.3
4.8
4.8
4.8
4.6
4.8
4.6
4.9
HP2-AC12V
HP2-AC24V
HP2-AC48V
HP2-AC115V
HP2-AC220V
HP2-AC240V
HP3-AC6V
12
24
19.2
38.4
92
2 Form C
48
39
115
220
240
6
18
176
192
4.8
9.5
9.0
520
260
130
65
72
264
1.8
3.6
7.2
14.4
34.5
66
6.6
HP3-AC12V
HP3-AC24V
HP3-AC48V
HP3-AC115V
HP3-AC220V
HP3-AC240V
HP4-AC6V
12
9.6
13.2
26.4
52.8
126.5
242
24
19.2
38.4
92
3 Form C
48
115
220
240
6
28.5
14.2
13.9
800
400
200
95
176
192
4.8
72
264
1.8
3.6
7.2
14.4
34.5
66
6.6
HP4-AC12V
HP4-AC24V
HP4-AC48V
HP4-AC115V
HP4-AC220V
HP4-AC240V
12
9.6
13.2
26.4
52.8
126.5
242
24
19.2
38.4
92
4 Form C
48
115
220
240
42
176
192
21
72
264
20.5
NOTES
1. The range of coil current for AC relays
is ±15% (60 Hz). For DC relays it is
±10% at 20°C, 68°F.
2. The HP relay will operate in a range
from 80% to 110% of the nominal coil
voltage. It is, however, recommended
that the relay be used in the range of
85% to 110% of the nominal coil volt-
age, with the temporary voltage varia-
tion taken into consideration.
lays drops below 80% of the nominal
coil voltage, the relay will generate a
considerable amount of heat which is
not recommended for maximum effi-
ciency.
4. The coil resistance of DC types is the
measured value of the coil at a temper-
ature of 20°C 68°F. If the coil tempera-
ture changes by ±1°C, the measured
value of the coil resistance should be
increased or decreased by 0.4%.
5. For applications from 220 V to 240 V
DC, connect a resistor in series with
the relay coil. See chart for resistor val-
ues.
Voltage
2 Form C 3 Form C 4 Form C
7.3 kΩ
(5 W)
7.45 kΩ
(5 W)
7 kΩ
(5 W)
220 V DC
8.7 kΩ
(5 W)
8.8 kΩ
(5 W)
8.3 kΩ
(5 W)
240 V DC
3. When the operating voltage of AC re-
2. Standard plug-in terminal type (with lamp wired)
DC TYPES at 20°C 68°F
Max.
allowable
voltage,
V DC
Nominal
operating
power,
W
Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.) V DC (min.)
Drop-out
voltage,
Coil
resistance,
Ω (±10%)
Nominal coil
current,
mA
Type
Part No.
HP2-L-DC6V
HP2-L-DC12V
HP2-L-DC24V
HP2-L-DC48V
6
12
24
48
110
6
4.8
9.6
0.9
1.8
3.6
7.2
16.5
0.9
1.8
3.6
7.2
16.5
0.9
1.8
3.6
7.2
16.5
6.6
13.2
26.4
52.8
121
6.6
25
110
240
109
54.5
26.7
15.0
250
120
60
1.5
1.3
1.3
1.3
1.7
1.5
1.4
1.4
1.5
1.6
1.6
1.5
1.5
1.5
1.7
LED
2 Form C
3 Form C
4 Form C
19.2
38.4
88
440
1,800
7,300
24
Neon lamp HP2-L-DC110V
HP3-L-DC6V
4.8
HP3-L-DC12V
LED
12
24
48
110
6
9.6
13.2
26.4
52.8
121
6.6
100
HP3-L-DC24V
19.2
38.4
88
400
HP3-L-DC48V
Neon lamp HP3-L-DC110V
HP4-L-DC6V
1,560
7,450
22
31
14.9
273
127
63
4.8
HP4-L-DC12V
LED
12
24
48
110
9.6
13.2
26.4
52.8
121
95
HP4-L-DC24V
19.2
38.4
88
380
HP4-L-DC48V
1,500
7,000
32
Neon lamp HP4-L-DC110V
15.7
413
HP
AC TYPE (50/60 Hz) at 60 Hz, 20°C 68°F
Max.
allowable
voltage,
V AC
Nominal
operating
power,
VA
Nominal coil
voltage,
V AC
Pick-up
voltage,
V AC (max.) V AC (min.)
Drop-out
voltage,
Nominal coil
current,
mA
Inductance,
H
Type
Part No.
HP2-L-AC6V
HP2-L-AC12V
HP2-L-AC24V
HP2-L-AC115V
6
4.8
9.6
1.8
3.6
7.2
34.5
66
6.6
13.2
26.4
126.5
242
0.049
0.190
0.776
15.83
57.90
66.26
0.030
0.119
0.475
10.36
39.32
44.05
0.019
0.077
0.309
6.953
26.57
29.75
310
160
78
1.9
1.9
1.9
2.1
2.1
2.2
3.1
3.1
3.1
3.3
3.1
3.3
4.8
4.8
4.8
4.8
4.6
4.9
LED
12
24
19.2
92
2 Form C
3 Form C
4 Form C
115
220
240
6
18
Neon lamp HP2-L-AC220V
HP2-L-AC240V
176
192
4.8
9.5
72
264
9.0
HP3-L-AC6V
1.8
3.6
7.2
34.5
66
6.6
520
260
130
28.5
14.2
13.9
800
400
200
42
LED
HP3-L-AC12V
HP3-L-AC24V
HP3-L-AC115V
12
9.6
13.2
26.4
126.5
242
24
19.2
92
115
220
240
6
Neon lamp HP3-L-AC220V
HP3-L-AC240V
176
192
4.8
72
264
HP4-L-AC6V
1.8
3.6
7.2
34.5
66
6.6
LED
HP4-L-AC12V
HP4-L-AC24V
HP4-L-AC115V
12
9.6
13.2
26.4
126.5
242
24
19.2
92
115
220
240
Neon lamp HP4-L-AC220V
HP4-L-AC240V
176
192
21
72
264
20.5
3.Top Mounting (TM) and direct mounting (M) type
DC TYPES at 20°C 68°F
Max.
allowable
voltage,
V DC
Nominal
operating
power,
W
Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.) V DC (min.)
Drop-out
voltage,
Coil
resistance,
Ω (±10%)
Nominal coil
current,
mA
Type
Part No.
HP2-TM-DC6V
HP2-TM-DC12V
HP2-TM-DC24V
HP2-TM-DC48V
HP2-TM-DC110V
HP3-M-DC6V
6
12
24
48
110
6
4.8
9.6
0.9
1.8
6.6
13.2
26.4
52.8
121
6.6
25
110
240
109
54.5
26.7
15.0
250
120
60
1.5
1.3
1.3
1.3
1.7
1.5
1.4
1.4
1.5
1.6
2 Form C
Top Mounting Type (TM)
19.2
38.4
88
3.6
440
7.2
1,800
7,300
24
16.5
0.9
4.8
HP3-M-DC12V
HP3-M-DC24V
HP3-M-DC48V
HP3-M-DC110V
12
24
48
110
9.6
1.8
13.2
26.4
52.8
121
100
3 Form C
Direct Mounting Type (TM)
19.2
38.4
88
3.6
400
7.2
1$B!"(J560
7,450
31
16.5
14.9
AC TYPE (50/60 Hz) at 60 Hz, 20°C 68°F
Max.
allowable
voltage,
V AC
Nominal
operating
power,
VA
Nominal coil
voltage,
V AC
Pick-up
voltage,
V AC (max.) V AC (min.)
Drop-out
voltage,
Nominal coil
current,
mA
Inductance,
H
Type
Part No.
HP2-TM-AC6V
HP2-TM-AC12V
HP2-TM-AC24V
HP2-TM-AC48V
HP2-TM-AC115V
HP2-TM-AC220V
HP2-TM-AC240V
HP3-M-AC6V
6
4.8
9.6
1.8
3.6
7.2
14.4
34.5
66
6.6
13.2
26.4
52.8
126.5
242
0.049
0.190
0.776
3.106
15.83
57.90
66.26
0.030
0.119
0.475
1.899
10.36
39.32
44.05
310
160
78
1.9
1.9
1.9
1.9
2.1
2.1
2.2
3.1
3.1
3.1
3.1
3.3
3.1
3.3
12
24
19.2
38.4
92
2 Form C
Top Mounting Type (TM)
48
39
115
220
240
6
18
176
192
4.8
9.5
72
264
9.0
1.8
3.6
7.2
14.4
34.5
66
6.6
520
260
130
65
HP3-M-AC12V
HP3-M-AC24V
HP3-M-AC48V
HP3-M-AC115V
HP3-M-AC220V
HP3-M-AC240V
12
9.6
13.2
26.4
52.8
126.5
242
24
19.2
38.4
92
3 Form C
Direct Mounting Type (M)
48
115
220
240
28.5
14.2
13.9
176
192
72
264
414
HP
4. Direct mounting (with lamp wired) type
DC TYPES
Max.
allowable
voltage,
V DC
Nominal
Nominal coil
voltage,
V DC
Pick-up
voltage,
V DC (max.) V DC (min.)
Drop-out
voltage,
Coil
resistance,
Ω (±10%)
Nominal coil
current,
mA
operating
power,
W
Type
Part No.
3 Form C Neon lamp
HP3-ML-DC110V
110
88
16.5
121
7,450
14.9
1.6
AC TYPE (50/60 Hz) at 60 Hz, 20°C 68°F
Max.
allowable
voltage,
V AC
Nominal
operating
power,
VA
Nominal coil
voltage,
V AC
Pick-up
voltage,
V AC (max.) V AC (min.)
Drop-out
voltage,
Nominal coil
current,
mA
Inductance,
H
Type
Part No.
HP3-ML-AC115V
HP3-ML-AC220V
HP3-ML-AC240V
115 V
220 V
240 V
92
34.5
66
126.5
242
10.36
39.32
44.05
28.5
14.2
13.9
3.3
3.1
3.3
3 Form C Neon lamp
176
192
72
264
LAMP-WIRED RELAYS
Specifications
NEON LAMP
LED
Life of neon lamp....continuous: more than 25,000 hours
(more than 3 years)
on/off = 1: more than 6 years
Life of LED..............continuous: more than 50,000 hours
(more than 5.5 years)
on/off = 1: more than 100,000 hours
(more than 11 years)
Variation
Coil Voltage
Type
AC
DC
6 V
6 V
12 V
12 V
24 V
48 V
110 V
—
LED (Light emitting diode)
Neon lamp
HP2-L
HP3-L
HP3-ML
HP4-L
24 V
—
115 V
220 V
240 V
—
Notes:
1. AC 48 V type is not available for lamp wiring.
Circuit diagrams
Operating current of LED
Neon lamp type
LED type
Coil Voltage
DC 6V
Operating current of LED
DC 6.4 mA
DC 12V
DC 24V
DC 48V
AC 6V
DC 5.7 mA
DC 4.7 mA
DC 4.5 mA
AC 10.5 mA
AC 9.0 mA
AC 12V
AC 24V
AC 7.7 mA
Notes:
1. Operating current of relays should be in-
creased by the value of LED operating current.
Please refer the table. Operating current of
neon lamp is approx. 0.3 mA to 0.4 mA.
2. To use the HP relay in the inductive load cir-
cuit, the contact protection circuit is recom-
mended.
Terminal No.
Type
(DC type)
HP4-L
HP3-L
HP3-ML
HP2-L
Polarity
( + )
7
2
10
2
10
1
( – )
Notes:
1. Pay attention to the polarity of coil See circuit diagram (LED type only).
415
HP
ACCESSORIES
Please refer to "MOUNTING METHODS" for further information.
UL, CSA recognized except BRACKET and INSERTING PLATE.
Solder terminal socket
for rectangular hold boring
(with hold-down clip)
Screw terminal socket
for DIN rail assembly
(with hold-down clip)
HP
Relay
For HP2, HP4
HP2-SRS
HP2-SFD
HP-BRACKET
for direct mounting
HP2
(UL, CSA, VDE)
HP3-SRS
(UL, CSA)
HP3-SFD
HP3
HP INSERTION PLATE for P/C
board mounting
(UL, CSA, VDE)
HP4-SRS
(UL, CSA, VDE)
HP4-SFD
HP4
(UL, CSA)
(UL, CSA)
mm inch
DIMENSIONS AND WIRING DIAGRAM
HP2 (2 Form C) Plug-in terminal types
5
8
5
0.5
.020
.197 .315.197
44
1.732
51
2.008
25
.984
15
.591
0.8 .031
Circuit diagram
5.26
.207
9.5 .374
7.5 .295
36
1.417
5.8 .228
5.3 .209
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
5.26 .207
10
.394
Min. 20mm .787 inch:
±1.5 ±.059
Accepts
Faston 205
416
HP
mm inch
HP2-SRS (with hold-down clip)
Optimum space-saving panel cut-out.
Can be mounted from either the front or
the rear of the panel.
Front surface-mounting
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
HOLD-DOWN CLIP
48±0.5
57.9±3
HP RELAY
+1
1.890±.020
2.280±.118
34
–0
+0.39
–0
1.339
5
HP SOCKET
.197
4 mm SCREW
SPRING WASHER
48±0.2
38
22
33
1.299
+0.1
–0
1.890
24
.945
1.496
.866
±.008
+.004
–0
56
2.205
13 .512
PANEL
5
Rear surface-mounting
.197
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
HOLD-DOWN CLIP
HP RELAY
6.2 .244
1.0 .039
6 .236
4.1
.161
5.5
13
30
.217
.512
56.9±3
1.181
2.240±.118
39
1.535
48±0.5
1.890±.020
HP SOCKET
4 mm SCREW
SPRING WASHER
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
14 .551
PANEL
31
1.220
Min. 20mm .787 inch:
±1.5 ±.059
HP2-SFD (with hold-down clip)
Mounting dimensions
Front wiring in restricted space
10±0.2
12
23.8±0.6
.937±.024
HP2 RELAY
2-M4 .157 SCREW HOLE or
4.2±0.1 .165±.004 DIA. HOLE
.394±.008
.472
22±0.2
22±0.2
.866±.008
.866±.008
HOLD DOWN CLIP
5.8±0.2
.228±.008
58±1
80±1
3.150±.039
2.283±.039
7.5±0.2
69±1
2.717±.039
36±1
69±0.5
2.717±.020 3.150
80
.295±.008
9.5±0.2
35.4±0.5
1.417±.039
1.394±.020
.374±.008
0.6±0.15
.024±.006
6±0.3
.236±.012
Installation screw
4.1±0.3
4 .157
10±0.6
.394±.024
30
30
.161±.012
block
1.181
1.181
15±0.2
.591±.008
22±0.6
33.8±0.6
(installation screw,
hexagonal nut,
spring washer)
1.331±.024
Panel hole dimensions
for side-by-side installation
37.9±0.6
.866±.024
1.492±.024
Max. 85 3.346
Max. 89 3.504
Note: Hold down clip and installation screw block are
included in package.
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
HP2-TM (2 Form C) Top mounting types
35.7
2.8
1.406
.110
52.3
46.8
2.059
1.843
4 mm SCREW or
8-32 NC-2 SCREW
SCREW WASHER
7
5.5 .217
.276
24.7
.972
35.7
PANEL
1.406
25
.984
15
Mounting dimensions
0.8
0.8
.031
Circuit diagram
.591
.031
9.5 .374
45.5 58
1.791 2.283
45.5
1.791
7.5 .295
5.8 .228
5.3 .209
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
2.25R .089R
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
4.5±0.1 DIA. HOLE or
5.26
.207
4.5
.177
5.26
4 mm SCREW HOLE
Accepts
Faston 205
2
.207
.117±.004 DIA. HOLE
.079
10
Min. 20mm .787 inch:
±1.5 ±.059
30
1.181
.394
417
HP
mm inch
HP3 (3 Form C) Plug-in terminal types
5
8
5
38
.197.315.197
1.496
0.5
.020
44
1.732
3
.118
7
.276
36
5
1.417
.197
38
1.496
11 11
.433 .433
Circuit diagram
4.75
.187
5.75
.226
5.5
Dimension :
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
General tolerance
±0.2 ±.008
0.5
.020
.217
8.5
36
1.417
2
.079
.335
7.65
.301
4
.157
4.1
.161
2
±1.5 ±.059
.079
Accepts
Faston 187
HP3-SRS (with hold-down clip)
Optimum space-saving panel cut-out.
Can be mounted from either the front or
the rear of the panel.
Front surface-mounting
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
22.23
.875
4.1
+1
31
1.220
–0
48±0.5
.161
40±0.3
6.2
.244
+0.39
–0
3.5
3.5
.138
1.890±.020
1.575±.012
.138
0.6 7.65
.024.301
HOLD DOWN CLIP
HP RELAY
5
48±0.2
1.890±.008
.197
+1
31
1.220
–0
+.039
5.5
52±0.3
–0
42.95 22
1.691 .866
38
56
30
.217
2.047±.012
1.496
2.205
1.181
Rear surface-mounting
5
.197
8.5
.335
4.2±0.1 DIA. HOLE or
2.75
.108
4 mm SCREW HOLE
4.2+−00.2 dia.
.165±.004 DIA. HOLE
.165+−.0008 dia.
1
8
11 11
Lot No.
.039
5.5
.217
.315
3.5
.138
.433.433
45
14.5
.571
30
1.772
1.181
+1
39
1.535
48±0.5
–0
+.039
–0
Dimension :
General tolerance
1.890±.020
Max. 2mm .079 inch:
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
+1
46
1.811
–0
+.039
–0
Min. 20mm .787 inch:
±1.5 ±.059
HP3-SFD (with hold-down clip)
Mounting dimensions
Front wiring in restricted space
2-M4 .157
22±0.2
23.8±0.6
.937±.024
HP3 RELAY
HOLD DOWN CLIP
SCREW HOLE or
4.2±0.1 .165±.004
DIA. HOLE
.866±.008
12
37±0.2
37±0.2
.472
1.457±.008
1.457±.008
5.5±0.2
58±1
2.283±.039
.217±.008
80±1
8.5±0.2
3.150±.039
69±1 36±1
.335±.008
2.717±.039 1.417±.039
35.4±0.5
69±0.5
2.717±.020 3.150
80
7.65±0.2
1.394±.020
.301±.008
1.75±0.15
.069±.006
6±0.3
Installation screw
10±0.6
.394±.024
.236±.012
block
4 .157
45
45
4.1±0.3
33.8±0.6
(installation screw,
hexagonal nut,
spring washer)
1.772
1.772
.161±.012
1.331±.024
37±0.6
1.457±.024
37.9±0.6
Panel hole dimensions
for side-by-side installation
1.492±.024
Max. 85 3.346
Max. 89 3.504
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
Note: Hold down clip and installation screw block are included in package.
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
418
HP
mm inch
HP3-M (3 Form C) Direct mounting types
38
1.496
Mounting dimension
16
.630
4.2
.165
2.1R
60
2.362
44
60
1.732 2.362
73.5
2.894
5
7
11
.197
.276 .433
2.1R
20.5
.807
3
.118
4.2±0.1 DIA. HOLE or
36
4 mm SCREW HOLE
4.2
1.417
.165±.004 DIA. HOLE
.165
MIN. 2
.079
16
.630
MIN. 40
1.575
38
1.496
11 11
.433 .433
4 mm SCREW or
8-32 NC-2 SCREW
SPRING
WASHER
4.75 4.75 4.75
.187 .187 .187
Circuit diagram
2.5
2.5
.098
5.75
.226
0.5
.020
.098
5.5
.217
8.5
0.5
2
.020
36
.079
0.5
.335
7.65
.301
1.417
.020
0.5 4.1
.020 .161
73.5
44
1.732
2.894
60
2.362
2
7
.079
.276
Accepts
Faston 187
20.5
.807
5
11
.433
.197
36
1.417
Dimension :
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
General tolerance
±0.2 ±.008
16
.630
38
1.496
Min. 20mm .787 inch:
±1.5 ±.059
HP4 (4 Form C) Plug-in terminal types
5
8
5
0.5
.197 .315 .197
.020
44
1.732
51
2.008
50
1.969
40
1.575
10
.394
Circuit diagram
0.8
.031
9.5 .374
5.26
.207
36
7.5 .295
1.417
5.8 .228
5.3 .209
25
.984
10
10
.394
.394
Accepts
Faston 187
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
419
HP
mm inch
HP4-SRS (with hold-down clip)
Optimum space-saving panel cut-out.
Can be mounted from either the front or
the rear of the panel.
Front surface-mounting
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
HOLD-DOWN CLIP
HP RELAY
53±3
+1
48±0.5
1.890
±.020
34
2.087±.118
5
–0
.197
1.339
+.039
–0
HP SOCKET
4 mm SCREW
SPRING WASHER
48±0.2
22
38
33
1.299
1.890
.866
56
2.205
1.496
±.008
+1
–0
+.039
–0
13 .512
48
PANEL
5
.197
6.2
.244
Rear surface-mounting
4.1
.161
1.0 .039
.236
13
.512
4.2±0.1 DIA. HOLE or
4 mm SCREW HOLE
.165±.004 DIA. HOLE
HOLD-DOWN CLIP
HP RELAY
6
58
5.5
.217
2.283
52±3
2.047±.118
39+–01 48±0.5
HP SOCKET
4 mm SCREW
SPRING WASHER
1.890
1.535
–0
Dimension :
Max. 2mm .079 inch:
General tolerance
±0.2 ±.008
+.039 ±.020
14
.551
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
PANEL
+1
58
–0
+.039
Min. 20mm .787 inch:
±1.5 ±.059
2.284
–0
HP4-SFD (with hold-down clip)
Front wiring in restricted space.
Two HP2 relays can be mounted in one socket.
25±0.1
Mounting dimensions
2-M4 .157 SCREW HOLE or
4.2±0.1 .165±.004 DIA. HOLE
12
23.8±0.6
.937±.024
53±0.2
53±0.2
.472
.984±.004
10±0.2
10±0.2
2.087±.008
2.087±.008
HOLD DOWN CLIP
.394±.008
.394±.008
HP4 RELAY
58±1
2.283±.039
5.8±0.2
69±0.5
.228±.008
80±1
3.150±.039
69±1
2.717±.020
7.5±0.2
2.717±.039
36±1
1.417±.039
.295±.008
35.4±0.5
80
9.5±0.2
1.394±.020
3.150
.374±.008
0.6±0.15
.024±.006
4 .157
61
61
10±0.6
.394±.024
Installation screw
6±0.3
2.402
2.402
.236±.012
block
15±0.2
.591±.008
15±0.2
33.8±0.6
Panel hole dimensions
for side-by-side installation
.591±.008
(installation screw,
hexagonal nut,
spring washer)
4.1±0.3
1.331±.024
.161±.012
37.9±0.6
53±0.6
2.087±.024
1.492±.024
Note: Hold down clip and installation screw block are
included in package.
Max. 85 3.346
Max. 89 3.504
Dimension :
General tolerance
Max. 2mm .079 inch:
±0.2 ±.008
2 to 9mm .079 to .354 inch: ±0.5 ±.020
9 to 20mm .354 to .787 inch: ±1.0 ±.039
Min. 20mm .787 inch:
±1.5 ±.059
ACCESSORIES for HP2 and HP4 types
HP Bracket (with 2 screws, 2 washers)
The HP Bracket is used for mounting HP2
relays and HP4 relays directly to the pan-
el. It facilitates soldering or quick connec-
tions with Faston 205 tab 0.8 mm .031
inch.
Mounting methods
(a) Remove the M3 × 7 screw (red col-
ored) fixed to the relay, and place the
bracket on the relay with the attaching M3
× 7 screw (blue colored) and the spring
washer.
(b) Use the additional M3 × 7 screw and
washer for attaching the bracket to the
panel.
For the HP4 type relay
8
two brackets are used
.315
Notes:
1. This bracket is unavailable for UL, CSA
and VDE applications.
23
.906
90°±3°
14
.551
2. When using the special bracket, it is
recommended to use the screws and
washers called out in the chart in the next
page in order to eliminate any possible
damage to the relay coil.
2 .079
14
.551
8.5
.335
20
.787
4
1
.158
.039
3 DIA. HOLE
.118 DIA. HOLE
3.5 DIA. HOLE
.138 DIA. HOLE
Keying tab.
420
HP
Thickness of a special bracket
A suitable screw
1.0 mm (.039 inch)
M3 × 7-M3 × 8
for M3
1.6 mm (.063 inch)
M3 × 8
2.0 mm (.079 inch)
M3 × 8-M3 × 10
for M3
A suitable washer
for M3
Screw
M
3
×
7
Millimeter
3mm .118inch diameter
7mm .276inch length
mm inch
Dimensions and mounting method
HP2
HP4
4.5 DIA. HOLE
.177 DIA. HOLE
4.5 DIA. HOLE
.177 DIA. HOLE
50
25
.984
1.969
3 mm SCREW
8.5
8.5
.335
.335
1. Rear-surface mounting
42
1.654
51
2.008
51
2.008
20
20
BRACKET
.787
.787
7
KEYING TAB
3 mm SCREW
51
2.008
7
.276
MIN.
26
MIN.
26
1.024
.276
25
25
PANEL
27
1.063
.984
.984
1.024
3.2 DIA. HOLE
.126 DIA. HOLE
3.2 DIA. HOLE
.126 DIA. HOLE
25
50
3 mm SCREW
.984
1.969
2. Front-surface mounting
44
44
42
1.654
1.732
1.732
3 mm SCREW
13 .512
13 .512
PANEL
KEYING
TAB
BRACKET
14.5 .571
28.5
1.122
44 1.732
51 2.008
14.5 .571
MIN.
26
MIN.
26
.984 1.024
25
25
1.024
.984
4.5 DIA. HOLE
.177 DIA. HOLE
4.5 DIA. HOLE
.177 DIA. HOLE
HP Inserting Plate for HP2 and HP4 types
1. HP inserting plate is used for mounting
HP2 and HP4 relays on a printed board to
adjust the length of the terminals.
2. If adjustment by soldering is not suit-
able, bore 1/8" diameter hole on the print-
ed circuit board and mount the relay with
a M3 × 10 screw. The chart to the right
suggests the proper screws for different
printed circuit boards.
3. Two plates are used for the HP4 type
relay.
Thickness of P/C board
1.0 mm .039 inch
Suitable screw
M3 × 10
1.2 mm .047 inch
M3 × 10
PC board pattern
HP2
HP4
15
.591
3
3
4.5 .177
25
.118
.118
.984
10
.394
10
10
1.0
.039
.394
5.8
.394
8 .315
.228
5.8 .228
1.0
.039
16
.630
5.8 .228
5.8 .228
4 DIA. HOLE
.157 DIA. HOLE
46
7.5
7.5
36
1.417
1.811
.295
.295
7.3
8.9
.350
8.9
.350
9.5
9.5
.287
HP INSERTION
PLATE
.374
.374
PC BOARD
16.5 .650
25 .984
15
.591
3.2 DIA. HOLE
.126 DIA. HOLE
15
.591
3.2 DIA. HOLE
.126 DIA. HOLE
15
5
.591
.197
2 .079
Please refer to the above second instruction.
Tolerance: ±0.1 ±.004
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.