Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
FEATURES  
PRODUCT OVERVIEW  
The UEP Series DC/DC Converters deliver  
the most power/current (up to 30W/6Amps)  
from a 1" x 2" package. And because of their  
footprint compatibility, they can be used as  
drop in replacements for their bigger brothers,  
the standard 2" x 2" and 1.6" x 2" devices,  
commonly used in the industry.  
n
Choice of 3 input ranges:  
10-18V, 18-36V, 36-75V  
n
Models Include  
3.3V @ 4.5A or 6A  
5V @ 3.5A or 6A  
15V @ 1.2A  
12V @ 1.4A  
By combining a high-frequency (340kHz),  
high-efficiency (to 89%), synchronous-rectifier  
topology with the newest components and  
time-tested, fully automated, SMT-on-pcb  
construction, these UEP Models are able  
to bring you 15-30W in the standard 2" x 1"  
package from which most competitors can  
only get 5-10W. All UEP’s deliver their full  
output power over ambient temperature  
ranges from –40°C to as high as +70°C  
(model and input voltage dependent) without  
heat sinks or supplemental forced-air cooling.  
Devices derate to +100°C.  
Output voltages are 3.3, 5, 12 or 15 Volts.  
Input voltage ranges are 10-18V (“D12”  
models), 18-36V (“D24” models) or 36-75V  
(“D48”) models. All models feature input pi  
filters, input undervoltage and overvoltage  
lockout, input reverse-polarity protection,  
output overvoltage protection, output current  
n
Guaranteed efficiencies to 89%  
n
15-30 Watts in 1" x 2" package  
n
340kHz synchronous-rectifier topologies  
n
–40 to +60/70°C ambient w/o derating  
n
Fully isolated (1500Vdc); I/O protected  
n
Trim and On/Off Control  
n
limiting, and continuous short-circuit protection.  
Standard features also include on/off control  
and output-trim. All models are certified to  
IEC950, UL1950 and EN60950 safety require-  
ments for OPERATIONAL insulation. “D48”  
models (36-75V inputs) are CE marked.  
UEP Series DC/DC’s are packaged  
in low-cost, light-weight, diallyl phthalate  
(UL94V-0 rated) plastic packages with stand-  
offs. EMC compliance is achieved via a low-  
noise design rather than through expensive  
metal shielding.  
UL1950/EN60950 certified  
n
CE mark (75VIN models)  
For full details go to  
www.murata-ps.com/rohs  
+INPUT  
(1)  
+OUTPUT  
(4)  
SWITCH  
CONTROL  
–OUTPUT  
(5)  
–INPUT  
(2)  
PWM  
CONTROLLER  
OPTO  
ISOLATION  
REFERENCE &  
ERROR AMP  
TRIM  
(6)  
UVLO & OVLO  
COMPARATORS  
ON/OFF  
CONTROL  
(3)  
3.3V and 5V-output models use the synchronous-rectifier configuration shown above.  
12V and 15V-output models employ a standard, diode-rectification architecture.  
Figure 1. Simplified Schematic  
Typical topology is shown.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 1 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Performance Specifications and Ordering Guide ➀  
Output  
R/N (mVp-p)  
Max.  
Input  
Package  
(Case,  
Pinout)  
Regulation (Max.)  
Efficiency  
Vo u t  
(Volts)  
Io u t  
(mA)  
Vin Nom.  
(Volts)  
Range  
(Volts)  
Vo u t  
(mA)  
Model  
Typ.  
85  
85  
85  
85  
85  
85  
85  
85  
85  
85  
85  
85  
85  
Line  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
0.2ꢀ  
Load ➂  
0.5ꢀ  
0.5ꢀ  
0.5ꢀ  
0.3ꢀ  
0.5ꢀ  
0.5ꢀ  
0.5ꢀ  
0.3ꢀ  
0.5ꢀ  
0.5ꢀ  
0.5ꢀ  
0.5ꢀ  
0.5ꢀ  
Min.  
Typ.  
84.5ꢀ  
87.5ꢀ  
87.5ꢀ  
88ꢀ  
UEP-3.3/4500-D12  
UEP-3.3/4500-D24  
UEP-3.3/4500-D48  
UEP-3.3/6000-D48  
UEP-5/3500-D12  
UEP-5/3500-D24  
UEP-5/3500-D48  
UEP-5/6000-D48  
UEP-12/1400-D12  
UEP-12/1400-D24  
UEP-12/1400-D48  
UEP-15/1200-D12  
UEP-15/1200-D24  
3.3  
3.3  
3.3  
3.3  
5
4500  
4500  
4500  
6000  
3500  
3500  
3500  
6000  
1400  
1400  
1400  
1200  
1200  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
12  
24  
48  
48  
12  
24  
48  
48  
12  
24  
48  
12  
24  
10-18  
18-36  
36-75  
36-75  
10-18  
18-36  
36-75  
36-75  
10-18  
18-36  
36-75  
10-18  
18-36  
80/1490  
50/730  
35/360  
40/470  
120/1760  
65/850  
40/430  
35/710  
60/1650  
45/800  
20/400  
60/1760  
45/860  
83.5ꢀ  
85.5ꢀ  
85.5ꢀ  
86ꢀ  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
C15, P21  
84ꢀ  
86ꢀ  
5
86ꢀ  
88ꢀ  
5
86ꢀ  
88ꢀ  
5
88ꢀ  
91ꢀ  
12  
12  
12  
15  
15  
82.5ꢀ  
85ꢀ  
85ꢀ  
87ꢀ  
85ꢀ  
87ꢀ  
82.5ꢀ  
85ꢀ  
85ꢀ  
87ꢀ  
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless otherwise noted.  
Ripple/Noise (R/N) is tested/specifed over a 20MHz bandwidth. All models are specified with no  
external input/output capacitors.  
Load regulation is specified over no load to 100ꢀ load conditions for 3.3 and 5Vo u t models, 25mA to  
100ꢀ load conditions for 12 and 15 Vo u t models.  
Nominal line voltage, no-load/full-load conditions.  
PART NUMBER STRUCTURE  
MECHANICAL SPECIFICATIONS  
2.00  
(50.80)  
U EP - 3.3 / 4500 - D48 N - C  
PLASTIC CASE  
0.49  
(12.45)  
Case C15  
ROHS-6  
Hazardous  
Output Configuration:  
Substance  
STANDOFF  
0.020 (0.51)  
0.040 0.001 DIA.  
(1.016 0.025)  
U = Unipolar  
Compliance  
0.20 MIN  
(5.08)  
External Pinout  
N Suffix  
1.800  
(45.72)  
0.10  
(2.54)  
Available for 12Vo u t  
and 15Vo u t Models  
1
2
4
5
Nominal Output Voltage:  
3.3, 5, 12 or 15 Volts  
0.800  
(20.32)  
0.600  
(15.24)  
1.00  
(25.40)  
Input Voltage Range:  
0.400  
(10.16)  
0.400  
(10.16)  
D12 = 10-18 Volts (12V nominal)  
D24 = 18-36 Volts (24V nominal)  
D48 = 36-75 Volts (48V nominal)  
3
6
BOTTOM VIEW  
0.100  
(2.54)  
0.10  
Maximum Output Current  
in mA  
(2.54)  
DIMENSIONS ARE IN INCHES (MM)  
Optional Functions  
I/O Connections  
UEP converters are designed such that the 12 and 15Vo u t models can be  
configured for either positive logic on/off control (no suffix) or negative logic  
(“N” suffix). 3.3 and 5Vo u t models are available with positive logic only (no suffix).  
Pin  
1
Function P21  
+Input  
2
–Input  
No Suffix On/Off Control function (positive polarity) on pin 3  
3
On/Off Control  
+Output  
–Output  
Trim  
N
On/Off Control function (negative polarity) on pin 3.  
(12V and 15V models only.)  
4
5
6
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 2 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Performance/Functional Specifications  
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀➁  
Input  
Dynamic Characteristics (continued)  
Input Voltage Range:  
Switching Frequency  
6A Models  
1.2A-4.5A Models  
D12 Models  
D24 Models  
D48 Models  
10-18 Volts (12V nominal)  
18-36 Volts (24V nominal)  
36-75 Volts (48V nominal)  
400kHz ( 20kHz)  
340kHz ( 40kHz)  
Environmental  
Overvoltage Shutdown:  
D12 Models  
D24 Models  
Operating Temperature (Ambient):  
Without Derating ➅  
With Derating  
18.5-21 Volts (20V typical)  
37-40 Volts (38V typical)  
77-81 Volts (78.5V typical)  
–40 to +60/70°C  
to +100°C (See Derating Curves)  
D48 Models ➆  
Case Temperature:  
Maximum Allowable  
Start-Up Threshold: ➂  
D12 Models  
D24 Models  
+100°C  
9.3-9.8 Volts (9.6V typical)  
16.5-18 Volts (17V typical)  
34-36 Volts (35V typical)  
Storage Temperature  
–40 to +105°C  
D48 Models  
Physical  
Undervoltage Shutdown: ➂  
D12 Models  
D24 Models  
Dimensions  
Shielding  
2" x 1" x 0.51" (51 x 25 x 12.95mm)  
None  
7-8.5 Volts (8V typical)  
15.5-17.5 Volts (16.5V typical)  
32.5-35.5 Volts (34.5V typical)  
Case Material  
Pin Material  
Weight  
Diallyl phthalate, (UL94V-0 rated)  
Gold-plated copper alloy with nickel underplate  
1.4 ounces (39.7 grams)  
D48 Models  
Input Current:  
Normal Operating Conditions  
Standby Mode (Off, OV, UV)  
See Ordering Guide  
5mA  
All models are specified with no external input/output capacitors.  
See Minimum Output Loading Requirements under Technical Notes.  
See Technical Notes for details.  
Input Filter Type  
Pi  
Reverse-Polarity Protection  
Brief duration, 10A maximum  
The On/Off Control is designed to be driven with open-collector logic or the application of appro-  
priate voltages (referenced to –Input (Pin 2)). Applying a voltage to the On/Off Control pin when  
no input voltage is applied to the converter may cause permanent damage. See Technical Notes.  
Output noise may be further reduced with the addition of external output capacitors. See Technical  
Notes.  
On/Off Control (Optional, Pin 3): ➃  
D12, D24, & D48 Models  
On = open or 13V - +VIN, IIN = 50µA max.  
Off = 0-0.8V, IIN = 1mA max.  
On = 0-0.5V, IIN = 50µA max.  
D12N, D24N, & D48N Models  
Off = open or 2.4-10V, IIN = 3.7mA max.  
Operating temperature range without derating is model and input-voltage dependent. See  
Temperature Derating.  
Output  
UEP-3.3/600-D48 and UEP-5/6000-D48 do not have overvoltage shutdown. See Absolute  
Maximum Ratings for allowable input voltages.  
VOUT Accuracy (50ꢀ load):  
1.5ꢀ, maximum  
Minimum Loading: ➁  
3.3V/5V Outputs  
12V/15V Outputs  
No load  
25mA  
Absolute Maximum Ratings  
Input Voltage:  
Continuous:  
Ripple/Noise (20MHz BW) ➀ ➄  
Line/Load Regulation  
Efficiency  
See Ordering Guide  
See Ordering Guide  
See Ordering Guide  
D12 Models  
D24 Models  
D48 Models  
22 Volts  
44 Volts  
88 Volts  
Isolation Voltage:  
Input-to-Output  
1500Vdc minimum  
470pF  
Transient (100msec):  
D12 Models  
D24 Models  
Isolation Capacitance  
Isolation Resistance  
22 Volts  
44 Volts  
88 Volts  
100MW  
D48 Models  
Current Limit Inception: ➂  
6A Models  
4.5A Models  
3.5A Models  
1.4A Models  
1.2A Models  
Input Reverse-Polarity Protection  
Current must be <10 Amps. Brief duration  
only. Fusing recommended.  
7-8 Amps  
5.5-7 Amps (6.25 Amps typ.)  
5.5-6 Amps (5.25 Amps typ.)  
1.9-2.7 Amps (2.3 Amps typ.)  
1.5-2.1 Amps (1.8 Amps typ.)  
Output Overvoltage Protection:  
3.3V Outputs  
5V/12V/15V Outputs  
4.5 Volts, unlimited duration  
6.8/15/18 Volts, unlimited duration  
Short Circuit: ➂  
Average Current  
Hiccup, indefinite  
3 Amps maximum  
Output Current  
Hiccup. Devices can withstand sustained  
output short circuits without damage.  
VOUT Trim Range ➂  
5ꢀ  
Case Temperature  
+100°C  
Overvoltage Protection ➂  
Temperature Coefficient  
Zener/transorb clamp, magnetic feedback  
0.02ꢀ per °C.Dynamic Characteristics  
Storage Temperature  
–40 to +105°C  
+300°C  
Lead Temperature (soldering, 10 sec.)  
Dynamic Characteristics  
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term  
reliability. Proper operation under conditions other than those listed in the Performance/Functional  
Specifications Table is not implied.  
Transient Response (50-100ꢀ load)  
300µsec max. to 1.5ꢀ of final value  
Start-Up Time: ➂  
VIN to VOUT  
50msec  
30msec  
On/Off to VOUT  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 3 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
4
TECHNICAL NOTES  
1
2
3
+OUTPUT  
TRIM  
+INPUT  
–INPUT  
Floating Outputs  
Since these are isolated DC/DC converters, their outputs are “floating.” Design-  
ers will usually use the –Output (pin 5) as the ground/return of the load circuit.  
You can, however, use the +Output (pin 4) as ground/return to effectively  
reverse the output polarity.  
6
5
20k  
5-22  
LOAD  
Turns  
ON/OFF  
CONTROL  
–OUTPUT  
Minimum Output Loading Requirements  
3.3 and 5V models employ a synchronous-rectifier design topology. All models  
regulate within spec and are stable under no-load conditions. 12/15V models  
employ a traditional forward, diode-rectification architecture and require 25mA  
loading to achieve their listed regulation specs. Operation under 25mA load  
conditions will not damage the 12/15V devices; however they may not meet all  
listed specifications.  
Figure 2.Trim Connections Using A Trim Pot  
4
1
2
3
+OUTPUT  
+INPUT  
RTRIM DOWN  
6
5
–INPUT  
TRIM  
LOAD  
Filtering and Noise Reduction  
All UEP Series DC/DC Converters achieve their rated ripple and noise speci-  
fications with no external input/output capacitors. In critical applications,  
input/output noise may be further reduced by installing external I/O caps.  
Input capacitors should be selected for bulk capacitance, low ESR and high  
rms-ripple-current ratings. Output capacitors should be selected for low ESR  
and appropriate frequency response. All caps should have appropriate voltage  
ratings and be mounted as close to the converters as possible.  
ON/OFF  
CONTROL  
–OUTPUT  
Figure 3.Trim Connections To Decrease Output Voltage Using Fixed Resistors  
4
1
2
3
+OUTPUT  
TRIM  
The most effective combination of external I/O capacitors will be a function  
of load and layout conditions. Our Applications Engineers can recommend  
potential solutions and discuss the possibility of our modifying a given device’s  
internal filtering to meet your specific requirements. Contact our Applications  
Engineering Group for additional details.  
+INPUT  
–INPUT  
6
LOAD  
RTRIM UP  
ON/OFF  
CONTROL  
5
–OUTPUT  
Input Fusing  
Certain applications and/or safety agencies may require the installation of  
fuses at the inputs of power conversion components. Fuses should also be  
used if the possibility of sustained, non-current-limited, input-voltage polarity  
reversals exists. For DATEL UEP Series DC/DC Converters, you should use  
slow-blow type fuses with values no greater than the following.  
Figure 4.Trim Connections To Increase Output Voltage Using Fixed Resistors  
Model  
Trim Equation  
2.49(VO 1.27)  
UEP-3.3/4500-D12  
UEP-3.3/4500-D24  
UEP-3.3/4500-D48  
UEP-3.3/6000-D48  
16.9  
–15  
RTDOWN (k) =  
3.3 VO  
VIN Range  
Fuse Value  
3.16  
D12 Models  
D24 Models  
3 Amps  
2 Amps  
1 Amp  
2 Amp  
16.9  
RTUP (k) =  
VO 3.3  
D48 Models (1.2-4.5A)  
D48 Models (6A)  
2.49(VO 2.527)  
5 VO  
UEP-5/3500-D12  
UEP-5/3500-D24  
UEP-5/3500-D48  
UEP-5/6000-D48  
RTDOWN (k) =  
RTUP (k) =  
6.292  
Trimming Output Voltages  
15  
VO 5  
These converters have a trim capability (pin 6) that allows users to adjust the  
output voltage 5ꢀ. Adjustments to the output voltage can be accomplished  
via a trim pot, Figure 2, or a single fixed resistor as shown in Figures 3 and 4.  
A single fixed resistor can increase or decrease the output voltage depend-  
ing on its connection. Fixed resistors should have an absolute TCR less than  
100ppm/°C to minimize sensitivity to changes in temperature.  
6.34(VO 5.714)  
12 VO  
49.9  
63.4  
RTDOWN (k) =  
RTUP (k) =  
RTDOWN (k) =  
RTUP (k) =  
UEP-12/1400-D12  
UEP-12/1400-D24  
UEP-12/1400-D48  
36.23  
49.9  
VO 12  
7.87(VO 7.136)  
15 VO  
UEP-15/1200-D12  
UEP-15/1200-D24  
UEP-15/1200-D48  
A single resistor connected from the Trim (pin 6) to the +Output (pin 4), see  
Figure 3, will decrease the output voltage. A resistor connected from the Trim  
(pin 6) to –Output (pin 5) will increase the output voltage.  
56.16  
63.4  
VO 15  
Trim adjustment greater than 5ꢀ can have an adverse effect on the converter's  
performance and is not recommended.  
Accuracy of adjustment is subject to tolerances of resistor values and factory-  
adjusted output accuracy. Vo = desired output voltage.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 4 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Input Overvoltage/Undervoltage Shutdown and Start-Up Threshold  
Under normal start-up conditions, devices will not begin to regulate until the  
ramping-up input voltage exceeds the Start-Up Threshold Voltage (35V for  
"D48" models). Once operating, devices will not turn off until the input voltage  
drops below the Undervoltage Shutdown limit (34V for "D48" models). Subse-  
quent re-start will not occur until the input is brought back up to the Start-Up  
Threshold. This built in hysteresis prevents any unstable on/off situations from  
occurring at a single input voltage.  
+INPUT  
1
3
ON/OFF  
CONTROL  
–INPUT  
2
Input voltages exceeding the input overvoltage shutdown specification listed in  
the Performance/Functional Specifications will cause the device to shutdown. A  
built-in hysteresis of 0.6 to 1.6 Volts for all models will not allow the converter  
to restart until the input voltage is sufficiently reduced.  
Figure 3. Driving the Negative Polarity On/Off Control Pin  
Dynamic control of the remote on/off function is best accomplished with a  
mechanical relay or an open-collector/open-drain drive circuit (optically iso-  
lated if appropriate). The drive circuit should be able to sink appropriate current  
(see Performance Specs) when activated and withstand appropriate voltage  
when deactivated.  
The two 6 Amp models do not feature overvoltage shutdown and withstand  
surges to 100V without shutting down. For custom overvoltage protection,  
contact DATEL.  
Input Reverse-Polarity Protection  
If the input-voltage polarity is accidentally reversed, an internal diode will  
become forward biased and likely draw excessive current from the power  
source. If the source is not current limited (<10A) nor the circuit appropriately  
fused, it could cause permanent damage to the converter.  
Applying an external voltage to pin 3 when no input power is applied to the  
converter can cause permanent damage to the converter.  
Start-Up Time  
The VIN to VOUT start-up time is the interval of time where the input voltage  
crosses the turn-on threshold point, and the fully loaded output voltage enters  
and remains within its specified accuracy band. Actual measured times will  
vary with input source impedance, external input/output capacitance, and load.  
The UEP Series implements a soft start circuit that limits the duty cycle of the  
PWM controller at power up, thereby limiting the Input Inrush current.  
On/Off Control  
The input-side, remote On/Off Control function (pin 3) can be ordered to oper-  
ate with either polarity (negative polarity available for 12 and 15 Volt models  
only). Positive-polarity devices (standard, no part-number suffix) are enabled  
when pin 3 is left open or is pulled high (+13V to VIN applied with respect to  
–Input, pin 2, (see Figure 2). Positive-polarity devices are disabled when pin 3  
is pulled low (0-0.8V with respect to –Input). Negative-polarity devices are off  
when pin 3 is open or pulled high (+2.4V to +10V), and on when pin 3 is pulled  
low (0-0.5V). See Figure 3.  
The On/Off Control to VOUT start-up time assumes the converter has its nominal  
input voltage applied but is turned off via the On/Off Control pin. The specifica-  
tion defines the interval between the time at which the converter is turned on  
and the fully loaded output voltage enters and remains within its specified  
accuracy band. Similar to the VIN to VOUT start-up, the On/Off Control to VOUT  
start-up time is also governed by the internal soft start circuitry and external  
load capacitance.  
+INPUT  
1
3
200k  
13V CIRCUIT  
5V CIRCUIT  
Current Limiting  
ON/OFF  
When output increases to 120ꢀ to 190ꢀ of the rated output current, the DC/DC  
converter will go into a current limiting mode. In this condition the output  
voltage will decrease proportionately with increases in output current, thereby  
maintaining a somewhat constant power dissipation. This is commonly  
referred to as power limiting. Current limit inception is defined as the point  
where the full-power output voltage falls below the specified tolerance. See  
Performance/Functional Specifications. If the load current being drawn from  
the converter is significant enough, the unit will go into a short circuit condi-  
tion. See “Short Circuit Condition.”  
CONTROL  
–INPUT  
2
Figure 2. Driving the Positive Polarity On/Off Control Pin  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 5 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Short Circuit Condition  
Typical Performance Curves  
When a converter is in current limit mode the output voltages will drop as the  
output current demand increases. If the output voltage drops too low, the  
magnetically coupled primary side voltages will also drop, thereby shutting  
down the PWM controller.  
Temperature Derating Curves for UEP-3.3/4500 Output Models  
17.5  
Following a time-out period, the PWM will restart, causing the output voltage to  
begin ramping to its appropriate value. If the short-circuit condition persists,  
another shutdown cycle will be initiated. This on/off cycling is referred to  
as "hiccup" mode. The hiccup cycling reduces the average output current,  
thereby preventing internal temperatures from rising to excessive levels. The  
UEP is capable of enduring an indefinite short circuit output condition.  
VIN = 18V-27V (D24)  
VIN = 36V-48V (D48)  
15  
12.5  
10  
VIN = 18V-30V (D24)  
VIN = 36V-60V (D48)  
Thermal Shutdown  
7.5  
These UEP converters are equipped with Thermal Shutdown Circuitry. If envi-  
ronmental conditions cause the internal temperature of the DC/DC converter  
rises above the designed operating temperature (typically 118°C case), a  
precision temperature sensor will power down the unit. When the internal  
temperature decreases below the threshold of the temperature sensor the unit  
will self start.  
VIN = 12V (D12)  
VIN = 18V-36V (D24)  
VIN = 36V-75V (D48)  
5
2.5  
0
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
Output Overvoltage Protection  
Ambient Temperature ( C)  
°
Output voltages are monitored for an overvoltage condition via magnetic  
coupling to the primary side. If the output voltage should rise to a level which  
could be damaging to the load circuitry, the sensing circuitry will power down  
the PWM controller causing the output voltages to decrease. Following a  
time-out period the PWM will restart, causing the output voltages to ramp to  
their appropriate values. If the fault condition persists, and the output voltage  
again climbs to excessive levels, the overvoltage circuitry will initiate another  
shutdown cycle. This on/off cycling is referred to as “hiccup” mode.  
5%0ꢀꢁꢂꢁꢃꢄꢅꢆꢆꢀ$ꢇꢄ %FFICIENCY VSꢂ ,INE 6OLTAGE AND ,OAD #URRENT  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
ꢃꢁ  
ꢆꢃ  
ꢆꢁ  
6). ꢁ ꢂꢃ6  
6
). ꢁ ꢄꢅ6  
6
). ꢁ ꢆꢇ6  
ꢁꢇꢆ  
ꢁꢇꢀꢈ  
ꢈꢇꢆꢉ  
ꢈꢇꢀꢆ  
ꢊꢇꢆꢃ  
ꢊꢇꢀꢅ  
ꢉꢇꢆꢂ  
ꢉꢇꢀꢀ  
ꢆꢇꢃ  
,OAD #URRENT ꢈ!MPSꢉ  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 6 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Typical Performance Curves  
Temperature Derating Curves for UEP-3.3/6000-D48  
UEP-3.3/4500-D48 Efficiency vs. Line Voltage and Load Current  
21  
18  
15  
12  
9
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
VIN = 36V  
V
IN = 36V  
VIN = 75V  
V
IN = 48V  
VIN = 48V  
6
V
IN = 75V  
3
0
0.4  
0.91  
1.43  
1.94  
2.45  
2.96  
3.48  
3.99  
4.5  
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
Load Current (Amps)  
Ambient Temperature ( C)  
˚
UEP-3.3/6000-D48 Efficiency vs. Line Voltage and Load Current  
5%0ꢀꢁꢂꢁꢃꢄꢅꢆꢆꢀ$ꢇꢈ %FFICIENCY VSꢂ ,INE 6OLTAGE AND ,OAD #URRENT  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
ꢃꢁ  
ꢆꢃ  
ꢆꢁ  
V
IN = 36V  
6
). ꢁ ꢂꢃ6  
V
IN = 48V  
6
). ꢁ ꢂꢄ6  
V
IN = 75V  
6
). ꢁ ꢂꢅ6  
1
2
3
4
5
6
ꢁꢇꢆ  
ꢁꢇꢀꢈ  
ꢈꢇꢆꢉ  
ꢈꢇꢀꢆ  
ꢊꢇꢆꢃ  
ꢊꢇꢀꢅ  
ꢉꢇꢆꢂ  
ꢉꢇꢀꢀ  
ꢆꢇꢃ  
Load Current (Amps)  
,OAD #URRENT ꢉ!MPSꢊ  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 7 of 11  
7
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Typical Performance Curves  
Temperature Derating Curves for UEP-5/6000-D48  
Temperature Derating Curves for UEP-5/3500 Output Models  
32  
28  
24  
20  
16  
12  
8
20  
17.5  
15  
VIN = 18V-27V (D24)  
VIN = 36V-48V (D48)  
VIN = 36V-48V  
12.5  
10  
VIN = 18V-30V (D24)  
VIN = 36V-60V (D48)  
7.5  
5
VIN = 75V  
VIN = 12V (D12)  
VIN = 18V-36V (D24)  
VIN = 36V-75V (D48)  
4
2.5  
0
0
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
Ambient Temperature ( C)  
Ambient Temperature ( C)  
˚
°
5%0ꢀꢁꢂꢃꢁꢄꢄꢀ$ꢅꢆ %FFICIENCY VSꢇ ,INE 6OLTAGE AND ,OAD #URRENT  
5%0ꢀꢁꢂꢃꢁꢄꢄꢀ$ꢅꢆ %FFICIENCY VSꢇ ,INE 6OLTAGE AND ,OAD #URRENT  
ꢀꢁ  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
ꢃꢁ  
ꢆꢃ  
ꢆꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
ꢃꢁ  
ꢆꢃ  
ꢆꢁ  
6
). ꢁ ꢂꢃ6  
6
). ꢁ ꢂꢃ6  
6
). ꢁ ꢄꢅ6  
6
). ꢁ ꢂꢄ6  
6
). ꢁ ꢆꢇ6  
6
). ꢁ ꢂꢅ6  
ꢁꢇꢈ  
ꢁꢇꢄ  
ꢉꢇꢉ  
ꢉꢇꢃ  
ꢉꢇꢀ  
ꢊꢇꢈ  
ꢊꢇꢄ  
ꢈꢇꢉ  
ꢈꢇꢃ  
ꢁꢇꢈ  
ꢁꢇꢄ  
ꢉꢇꢉ  
ꢉꢇꢃ  
ꢉꢇꢀ  
ꢊꢇꢈ  
ꢊꢇꢄ  
ꢈꢇꢉ  
ꢈꢇꢃ  
,OAD #URRENT ꢈ!MPSꢉ  
,OAD #URRENT ꢈ!MPSꢉ  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 8 of 11  
8
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Typical Performance Curves  
Temperature Derating Curves for 12V Output Models  
UEP-5/3500-D48 Efficiency vs. Line Voltage and Load Current  
18  
16  
14  
12  
10  
8
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
VIN = 18V-27V (D24)  
VIN = 36V-48V (D48)  
V
IN = 36V  
VIN = 18V-30V (D24)  
VIN = 36V-60V (D48)  
V
IN = 48V  
VIN = 12V (D12)  
6
VIN = 18V-36V (D24)  
VIN = 36V-75V (D48)  
V
IN = 75V  
4
2
0
0.3  
0.7  
1.1  
1.5  
1.9  
2.3  
2.7  
3.1  
3.5  
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
Load Current (Amps)  
Ambient Temperature ( C)  
˚
UEP-5/6000-D48 Efficiency vs. Line Voltage and Load Current  
5%0ꢀꢁꢂꢃꢁꢄꢅꢅꢀ$ꢂꢄ %FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT  
95  
90  
85  
80  
75  
70  
65  
60  
55  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
V
IN = 36V  
6
). ꢁ ꢂꢃ6  
V
IN = 48V  
6
). ꢁ ꢄꢅ6  
V
IN = 75V  
6
). ꢁ ꢆꢇ6  
1
2
3
4
5
6
ꢁꢆꢇꢁ  
ꢁꢆꢈꢅ  
ꢁꢆꢉꢊ  
ꢁꢆꢃꢀ  
ꢁꢆꢄꢃ  
ꢁꢆꢀꢇ  
ꢇꢆꢁꢅ  
ꢇꢆꢈꢉ  
ꢇꢆꢉꢁ  
Load Current (Amps)  
,OAD #URRENT ꢇ!MPSꢈ  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 9 of 11  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Typical Performance Curves  
5%0ꢀꢁꢂꢃꢁꢄꢅꢅꢀ$ꢁꢂ %FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT  
5%0ꢀꢁꢂꢃꢁꢄꢅꢅꢀ$ꢄꢆ %FFICIENCY VSꢇ ,INE 6OLTAGE AND ,OAD #URRENT  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
6
). ꢁ ꢂꢃ6  
6
). ꢁ ꢂꢃ6  
6
). ꢁ ꢄꢅ6  
6
). ꢁ ꢂꢄ6  
6
). ꢁ ꢂꢅ6  
6
). ꢁ ꢆꢇ6  
ꢁꢆꢇꢁ  
ꢁꢆꢈꢅ  
ꢁꢆꢉꢊ  
ꢁꢆꢃꢀ  
ꢁꢆꢄꢃ  
ꢁꢆꢀꢇ  
ꢇꢆꢁꢅ  
ꢇꢆꢈꢉ  
ꢇꢆꢉꢁ  
ꢁꢆꢇꢁ  
ꢁꢆꢈꢉ  
ꢁꢆꢊꢂ  
ꢁꢆꢃꢇ  
ꢁꢆꢅꢃ  
ꢁꢆꢄꢀ  
ꢁꢆꢀꢊ  
ꢇꢆꢁꢅ  
ꢇꢆꢈ  
,OAD #URRENT ꢇ!MPSꢈ  
,OAD #URRENT ꢈ!MPSꢉ  
UEP-12/1400-D48 Efficiency vs. Line Voltage and Load Current  
5%0ꢀꢁꢂꢃꢁꢄꢅꢅꢀ$ꢁꢄ %FFICIENCY VSꢆ ,INE 6OLTAGE AND ,OAD #URRENT  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
ꢀꢁ  
ꢂꢃ  
ꢂꢁ  
ꢄꢃ  
ꢄꢁ  
ꢅꢃ  
ꢅꢁ  
ꢃꢃ  
V
IN = 36V  
6
). ꢁ ꢂꢃ6  
V
IN = 48V  
6
). ꢁ ꢂꢄ6  
V
IN = 75V  
6
). ꢁ ꢂꢅ6  
0.10  
0.26  
0.43  
0.59  
0.75  
0.91  
1.06  
1.24  
1.40  
ꢁꢆꢇꢁ  
ꢁꢆꢈꢉ  
ꢁꢆꢊꢂ  
ꢁꢆꢃꢇ  
ꢁꢆꢅꢃ  
ꢁꢆꢄꢀ  
ꢁꢆꢀꢊ  
ꢇꢆꢁꢅ  
ꢇꢆꢈ  
Load Current (Amps)  
Temperature Derating Curves for 15V Output Models  
,OAD #URRENT ꢇ!MPSꢈ  
UEP-15/1200-D48 Efficiency vs. Line Voltage and Load Current  
20  
90  
85  
80  
75  
70  
65  
60  
55  
50  
18  
16  
14  
12  
10  
8
VIN = 18V-27V (D24)  
VIN = 36V-48V (D48)  
VIN = 18V-30V (D24)  
VIN = 36V-60V (D48)  
VIN = 36V  
VIN = 12V (D12)  
VIN = 48V  
6
VIN = 18V-36V (D24)  
VIN = 36V-75V (D48)  
4
VIN = 75V  
2
0
–40  
0
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
0.10  
0.24  
0.38  
0.51  
0.65  
0.79  
0.93  
1.06  
1.2  
Ambient Temperature ( C)  
˚
Load Current (Amps)  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 10 of 11  
1 5 - 3 0 W , S I N G L E O U T P U T D C / D C C O N V E R T E R S  
Single Output UEP Models  
Ultra-High Density, 2" x 1", 1.2-6 Amp,15-30 Watt DC/DC’s  
Typical Performance Curves  
Output Ripple and Noise (PARD)  
(VIN = nominal, 3.3V @ 4.5A, no external capacitors.)  
Output Ripple and Noise (PARD)  
(VIN = nominal, 12V @ 1.4A, no external capacitors.)  
20mV/div, 20MHz BW  
Output Ripple and Noise (PARD)  
(VIN = nominal, 5V @ 3.5A, no external capacitors.)  
Output Ripple and Noise (PARD)  
(VIN = nominal, 15V @ 1.2A, no external capacitors.)  
20mV/div, 20MHz BW  
20mV/div, 20MHz BW  
USA:  
Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com  
UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com  
Tucson (AZ), Tel: (800) 547 2537, email: sales@murata-ps.com  
France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com  
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com  
Murato Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356  
Japan:  
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com  
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com  
Website: www.murata-ps.jp  
China:  
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com  
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com  
www.murata-ps.com  
ISO 9001 REGISTERED  
email: sales@murata-ps.com  
DS-0502B  
2/14/08  
© 2008 Murata Power Solutions, Inc.  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not  
imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change  
without notice.  
www.murata-ps.com  
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000  
MDC_UEP Models.A02 Page 11 of 11  

相关型号:

UEP-3.3/4500-D12

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA

UEP-3.3/4500-D24

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA

UEP-3.3/4500-D48

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA

UEP-3.3/6000-D48

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA

UEP-5-3500-D12

Single Output UEP Models
MURATA

UEP-5-3500-D24

Single Output UEP Models
MURATA

UEP-5-3500-D48

Single Output UEP Models
MURATA

UEP-5-6000-D48

Single Output UEP Models
MURATA
ETC

UEP-5/3500-D24

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA

UEP-5/3500-D24-C

DC-DC Regulated Power Supply Module, 1 Output, 17.5W, Hybrid, ROHS COMPLIANT, PLASTIC, 6 PIN
MURATA

UEP-5/3500-D48

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, PLASTIC, 10 PIN
MURATA