NCS1S2412SC [MURATA]

民用设备,工业设备;
NCS1S2412SC
型号: NCS1S2412SC
厂家: muRata    muRata
描述:

民用设备,工业设备

文件: 总8页 (文件大小:187K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NCS1 Series  
s
Isolated 1W 4:1 Input Single Output DC/DC Converters  
SELECTION GUIDE  
Efficiency  
5V or 24V Input.  
Efficiency  
12V Input.  
Input  
Voltage  
Ripple and Noise  
MTTF1  
Output  
Voltage  
Output  
Current  
Order Code  
Nom.  
V
Min.  
%
Typ.  
%
77  
Min.  
%
Typ.  
%
Typ.  
mVp/p mVp/p  
Max.  
V
3.3  
5
mA  
303  
200  
83  
pF  
24  
30  
35  
28  
42  
42  
kHrs  
1020  
915  
NCS1S1203SC  
NCS1S1205SC  
NCS1S1212SC  
NCS1S2403SC  
NCS1S2405SC  
NCS1S2412SC  
12  
12  
12  
24  
24  
24  
73  
76  
75  
76  
79  
80  
71  
74  
75  
73  
77  
77  
75  
77  
79  
76  
80  
80  
24  
25  
40  
35  
27  
28  
70  
50  
79  
12  
3.3  
5
78  
120  
70  
1130  
1217  
1022  
943  
303  
200  
83  
78.5  
82  
50  
12  
83  
120  
FEATURES  
INPUT CHARACTERISTICS  
„ UL 60950 recognised  
Parameter  
Conditions  
Min.  
4.5  
9
Typ.  
Max.  
18  
Units  
V
„4:1 Wide range voltage input  
12V input types  
24V input types  
12  
24  
Voltage range  
36  
„Operating temperature range -40°C to  
5V input voltage  
12V input voltage  
12V input voltage  
24V input voltage  
0.26  
0.1  
0.1  
0.05  
5
105°C with derating  
NCS1S12XX  
NCS1S24XX  
Input current  
A
„1kVDC Isolation “Hi Pot Test”  
„3.3V, 5V & 12V outputs  
NCS1S12XX  
NCS1S24XX  
30  
15  
Input reflected ripple  
current  
„No electrolytic capacitors  
„Continuous short circuit protection  
mA p-p  
5
OUTPUT CHARACTERISTICS  
Parameter  
Rated power  
Conditions  
All output types  
Min.  
10  
Typ.  
Max. Units  
PRODUCT OVERVIEW  
1
W
%
The NCS1 series of DC/DC converters offers a  
single output voltage from input voltage ranges  
of 4.5-18V and 9-36V. The NCS1 is housed in an  
industry standard package with a standard pinout.  
Minimal load to meet datasheet specification  
Voltage set point accuracy All output types  
1
2
%
Line regulation  
Load regulation  
Low line to high line  
All output types  
0.5  
0.5  
%
%
Peak deviation (12.5-37.5% & 37.5-12.5% swing)  
Settling time  
(within 5% Vout Nom.)  
5
%Vout  
Applications include telecommunications, battery  
powered systems, process control and distributed  
power systems.  
Transient response  
2
ms  
ISOLATION CHARACTERISTICS  
Parameter  
Isolation test voltage  
Resistance  
Conditions  
Flash tested for 1 second  
Viso = 1kVDC  
Min.  
1000  
1
Typ.  
Typ.  
Max.  
Units  
VDC  
GΩ  
GENERAL CHARACTERISTICS  
Parameter  
Switching frequency  
Conditions  
Min.  
100  
Max. Units  
400  
kHz  
Module on, pin unconnected or open collector floating  
Module off  
Control pin input  
0.8  
V
1 Calculated using MIL-HDBK-217 FN2, parts stress method with nominal input voltage at full load.  
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.  
For full details go to  
www.murata-ps.com/rohs  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 1 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
TEMPERATURE CHARACTERISTICS  
Parameter  
Operation  
Conditions  
Min.  
-40  
Typ.  
15  
Max.  
105  
125  
22  
Units  
°C  
Storage  
-50  
Case temperature rise above ambient  
100% Load, Nom VIN, Still Air  
ABSOLUTE MAXIMUM RATINGS  
Short-circuit protection (for SELV input voltages)  
Control pin input voltage  
Continuous  
18V Max  
260°C  
25V  
Lead temperature 1.0mm from case for 10 seconds (to JEDEC JESD22-B106 ISS C)  
Input voltage, NCS1 12V input types  
Input voltage, NCS1 24V input types  
40V  
APPLICATION NOTES  
Maximum Output Capacitance  
Maximum output capacitance should not exceed:  
Output Voltage  
Maximum Load Capacitance  
V
3.3  
5
μF  
470  
470  
220  
12  
Start-up times  
Typical start up times for this series, with a typical input voltage rise time of 2.2ꢁs and output capacitance of 10ꢁF, are shown in the table below. The product series will  
start into the maximum output capacitance with increased start times.  
Start-up times  
Part No.  
ms  
NCS1S1203SC  
NCS1S1205SC  
NCS1S1212SC  
NCS1S2403SC  
NCS1S2405SC  
NCS1S2412SC  
6
9
20  
12  
7
12  
Control Pin  
The NCS1 converters have a shutdown feature which enables the user to put the converter into a low power state. The control pin connects directly to the base of an internal  
transistor, and the switch off mechanism for the NCS1 works by forward biasing this NPN transistor. If the pin is left open (high impedance), the converter will be ON (there is  
no allowed low state for this pin), but once a control voltage is applied with sufficient drive current, the converter will be switched OFF. A suitable application circuit is shown  
below.  
D1 (e.g. 1N4003) is required to provide high impedence when the signal is  
low. From the NCS1 specification, the drive current to operate this function is  
recommended to be 3mA, and hence the value of R1 can be derived as follows:  
NCS1  
VIN  
R2  
Q1  
VC - VD - VQ  
R1 =  
IC  
R1  
VC  
OV  
-VIN  
D1  
CTRL  
Assuming VC=5V, VD=0.7V and VQ=1V:  
5 - 0.7 - 1.0  
R1=  
= 1100ꢀ  
3 x 10-3  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 2 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
TECHNICAL NOTES  
ISOLATION VOLTAGE  
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,  
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.  
Murata Power Solutions NCS1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.  
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”  
The NCS1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V  
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.  
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier  
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according  
to safety standard requirements.  
REPEATED HIGH-VOLTAGE ISOLATION TESTING  
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,  
construction and environment. The NCS1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While  
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically  
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We  
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.  
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further  
insulation system of physical spacing or barriers.  
SAFETY APPROVAL  
The NCS1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum case temperature of 105°C. File number E151252  
applies.  
The NCS1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.  
NCS1S12xxSC: 1A  
NCS1S24xxSC: 0.5A  
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.  
RoHS COMPLIANCE INFORMATION  
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish  
on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering  
systems.  
CHARACTERISATION TEST METHODS  
Ripple & Noise Characterisation Method  
Ripple and noise measurements are performed with the following test configuration.  
C1  
C2  
1ꢁF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter  
10ꢁF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less  
than 100mꢀ at 100 kHz  
C3  
R1  
100nF multilayer ceramic capacitor, general purpose  
450ꢀ resistor, carbon film, 1% tolerance  
R2  
50ꢀ BNC termination  
T1  
3T of the coax cable through a ferrite toroid  
RLOAD  
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires  
Measured values are multiplied by 10 to obtain the specified values.  
Differential Mode Noise Test Schematic  
DC/DC Converter  
OSCILLOSCOPE  
Y INPUT  
R2  
C1 C2 C3  
R1  
T1  
+
+
Input  
Output  
SUPPLY  
-
-
R LOAD  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 3 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
EFFICIENCY VS LOAD  
NCS1S1203SC  
NCS1S1205SC  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
80  
70  
60  
50  
40  
30  
20  
10  
0
4.5 Vin  
Vin  
4.5 Vin  
5 Vin  
5
12 Vin  
18 Vin  
12 Vin  
18 Vin  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
Load (%)  
NCS1S1212SC  
NCS1S2403SC  
90  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
80  
70  
60  
50  
40  
30  
20  
10  
0
9 Vin  
4.5 Vin  
12 Vin  
24 Vin  
36 Vin  
5
Vin  
12 Vin  
18 Vin  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
Load (%)  
NCS1S2405SC  
NCS1S2412SC  
90  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
80  
70  
60  
50  
40  
30  
20  
10  
0
9 Vin  
9 Vin  
12 Vin  
24 Vin  
36 Vin  
12 Vin  
24 Vin  
36 Vin  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Load (%)  
Load (%)  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 4 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
TEMPERATURE DERATING  
NCS1S1203SC  
NCS1S1205SC  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
0%  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
0%  
still air  
still air  
100 lfm  
200 lfm  
400 lfm  
100 lfm  
200 lfm  
400 lfm  
70  
80  
90  
100  
110  
80  
90  
100  
110  
Ambient Temperature OC  
Ambient Temperature OC  
NCS1S1212SC  
NCS1S2403SC  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
still air  
100 lfm  
200 lfm  
400 lfm  
still air  
100 LFM  
200 LFM  
400 LFM  
0%  
80  
0%  
70  
90  
100  
110  
75  
80  
85  
90  
95  
100  
105  
Ambient Temperature OC  
Ambient Temperature OC  
NCS1S2405SC  
NCS1S2412SC  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
100%  
90%  
80%  
70%  
60%  
50%  
40%  
30%  
20%  
10%  
still air  
still air  
100 LFM  
200 LFM  
400 LFM  
100 lfm  
200 lfm  
400 lfm  
0%  
70  
0%  
80  
80  
90  
100  
110  
90  
100  
110  
Ambient Temperature OC  
Ambient Temperature OC  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 5 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
EMC FILTERING AND SPECTRA  
FILTERING  
The module includes a basic level of filtering, the following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve A  
Quasi-Peak EMC limit, as shown in the following plots.  
Part Number  
Capacitor  
Inductor  
Common Mode Choke  
NCS1S1203SC  
NCS1S1205SC  
NCS1S1212SC  
NCS1S2403SC  
NCS1S2405SC  
NCS1S2412SC  
330nF  
330nF  
2.2ꢁF  
330nF  
330nF  
330nF  
500ꢁH  
500ꢁH  
2.2mH  
500ꢁH  
500ꢁH  
500ꢁH  
700ꢁH  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 6 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
EMC FILTERING AND SPECTRA  
NCS1S1203SC  
NCS1S1205SC  
80  
70  
60  
50  
40  
30  
20  
10  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
1.00E+05  
1.00E+06  
1.00E+07  
1.00E+08  
1.00E+08  
1.00E+08  
1.00E+05  
1.00E+06  
1.00E+07  
1.00E+08  
1.00E+08  
1.00E+08  
Frequency (Hz)  
Frequency (Hz)  
NCS1S1212SC  
NCS1S2403SC  
80  
70  
60  
50  
40  
30  
20  
10  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
1.00E+05  
1.00E+06  
1.00E+07  
1.00E+05  
1.00E+06  
1.00E+07  
Frequency (Hz)  
Frequency (Hz)  
NCS1S2405SC  
NCS1S2412SC  
80  
70  
60  
50  
40  
30  
20  
10  
80  
70  
60  
50  
40  
30  
20  
10  
0
0
1.00E+05  
1.00E+06  
1.00E+07  
1.00E+05  
1.00E+06  
1.00E+07  
Frequency (Hz)  
Frequency (Hz)  
www.murata-ps.com  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 7 of 8  
NCS1 Series  
Isolated 1W 4:1 Input Single Output DC/DC Converters  
PACKAGE SPECIFICATIONS  
MECHANICAL DIMENSIONS  
PIN CONNECTIONS  
Function  
Single  
Pin  
21.87 [0.861] MAX  
1
2
3
6
7
-VIN  
+VIN  
Control  
+VOUT  
-VOUT  
8.2 [0.323] MAX  
TUBE OUTLINE DIMENSIONS  
0.50 (0.0197)  
NCS1S1205SC  
XYYWW  
11.30 [0.445] MAX  
12.30 (0.484)  
0.40 [0.016] MIN  
0.75 (0.0295)  
0.20 (0.0079)  
4.10 0.50  
[0.161 0.020]  
5.00 (0.1969)  
1 2 3  
6 7  
0.50 0.05  
[0.020 0.002]  
2.00 (0.0787)  
2.00 (0.0787)  
2.54 [0.100]  
8.20  
(0.3228)  
15.24 [0.600]  
All dimensions in millimetres 0.5 (inches 0.01).  
Tube length: 520 2 (20.47 inches 0.079).  
Quantity: 23  
RECOMMENDED FOOTPRINT DETAILS  
3.52 0.139  
2.87 0.113  
[ ]  
2.54 [0.100]  
0.25 0.05 [0 .010 0.002]  
2.62 0.103  
1.92  
0.076  
[
]
x6 HOLES  
1.15  
1.00  
0.045  
Ø
Ø
[
0.039  
0.1  
]
2.54 [0.100]  
Weight: 3.3g  
All dimensions in millimetres (inches) 0.5 (0.020) except pin to pin tolerance 0.25 (0.010).  
All pins on a 2.54 (0.100) pitch and within 0.25 (0.010) of true position.  
All dimensions in mm (inches) 0.25 ( 0.010).  
This product is subject to the following operating requirements  
and the Life and Safety Critical Application Sales Policy:  
Refer to: http://www.murata-ps.com/requirements/  
Murata Power Solutions, Inc.  
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.  
ISO 9001 and 14001 REGISTERED  
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other  
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply  
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without  
notice.  
© 2015 Murata Power Solutions, Inc.  
www.murata-ps.com/support  
All enquiries: www.murata-ps.com/support  
KDC_NCS1.D01 Page 8 of 8  

相关型号:

NCS2-222+

RF Transformer, 1275MHz Min, 2200MHz Max, ROHS COMPLIANT
MINI

NCS2-222-2+

RF Transformer,
MINI

NCS2-232

RF Transformer
MINI

NCS2-232+

RF Transformer
MINI

NCS2-33+

RF Transformer, 1500MHz Min, 3100MHz Max, ROHS COMPLIANT
MINI

NCS2-33D+

RF Transformer,
MINI

NCS2-392+

RF Transformer, 3000MHz Min, 3900MHz Max, ROHS COMPLIANT
MINI

NCS2-592

RF Transformer
MINI

NCS2-592+

RF Transformer
MINI

NCS2-62

RF Transformer
MINI

NCS2-62+

RF Transformer
MINI

NCS2-622+

RF Transformer, 5600MHz Min, 6200MHz Max, ROHS COMPLIANT
MINI