CRE1S0505S3C [MURATA]
民用设备,工业设备;CRE1 Series
s
Isolated 1W Single Output Isolated DC/DC Converters
SELECTION GUIDE
%
mV p-p
%
MIL. Tel.
kHrs
V
V
mA
mA
pF
Typ. Max. Typ. Max.
Min. Typ.
CRE1S0505DC
CRE1S0505SC
CRE1S0515SC
CRE1S1205SC
CRE1S1212SC
CRE1S2405SC
CRE1S2412SC
5
5
5
5
5
200 12
200 12
14
14
7.5
10
5
16
16
10
12
8
40
40
25
30
20
30
25
286
286
250
117
104
58
65
65
77
68
75
67
75
70
70
80
71
80
71
80
30
30
40
33
55
40
78
15
5
67
200
83
6
8
4
FEATURES
12
12
24
24
ꢀUL 60950 recognised3
12
5
200 8.5
83
10
4
13
10
ꢀSingle Isolated output
12
3
52
ꢀ1kVDC or 3kVDC option ‘Hi Pot Test’
3KVDC isolation options
200 10
CRE1S0305S3C 3.3
CRE1S0505S3C
5
5
12
15
25
400
250
72
73
75
77
35
24
ꢀWide temperature performance at full
5
200
6
8
15
25
1W load -40°C to 85°C4
ꢀ
Surface mount options
200 12.8 15
200 6.5
ꢀIndustry Standard Pinout
CRE1S0505MC
CRE1S0505MEC
5
5
5
5
62
25
85
70
294
239
68
82
35 6857
22 3041
8
79
ꢀ3.3V, 5V, 12V & 24V Inputs
ꢀ5V, 12V & 15V outputs
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
2.97
4.5
Typ.
Max.
3.63
5.5
Units
ꢀPin Compatible with CME, CRL2, LME,
MEE1, MEE3, MTE1, NKE, NME, NML &
NTE series
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 24V input types
3.3V & 12V input types
3.3
5.0
12
24
1
V
Voltage range
10.8
21.6
13.2
26.4
15
Through hole and surface mount options
available
5V & 24V input types
2
15
Reflected ripple current
mA p-p
CRE1S0505MC
30
5
47
PRODUCT OVERVIEW
CRE1S0505MEC
15
The CRE1 series are a cost effective 1W DC/DC
converter series, in industry standard packages
with industry standard pinout. Popular input
and output voltages are available. The galvanic
isolation allows the device to be configured to
provide an isolated negative rail in systems where
only positive rails exist. The wide temperature
range guarantees startup from –40°C and full 1
watt output at 85°C3.
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Conditions
TA=-40°C to 85°C3
Min.
Typ.
1.1
Max.
1
Units
W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High VIN to low VIN
1.2
%/%
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
1000
3000
Typ.
Max.
Units
VDC
GΩ
C Versions Flash tested for 1 second
3C Versions Flash tested for 1 second
Viso= 1000VDC
Isolation test voltage
Resistance
10
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
115
110
145
100
80
Max.
Units
kHz
3.3V input types
5V input types
12V input types
24V input types
CRE1S0505MEC
Switching frequency
1. If components are required in tape and reel format suffix order code with -R, e.g. CRE1S0505MC-R.
2. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load.
3. UL 60950 recognition does not apply to CRE1S0505MC.
4. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70°C.
For full details go to
www.murata-ps.com/rohs
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com/support
KDC_CRE1.D01 Page 1 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, 3.3V input
260°C
5.5V
7V
Input voltage VIN, 5V input
Input voltage VIN, 12V input
15V
28V
Input voltage VIN, 24V input
TEMPERATURE CHARACTERISTICS
Parameter
Specification
Storage
Conditions
Min.
-40
Typ.
Max.
85
Units
°C
All output types1
-50
130
41
5V output types
All other output types
CRE1S0505MC
32
Case temperature rise above
ambient
43
CRE1S0505MEC
Free air convection
12.5
Cooling
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions CRE1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1
second for 3C versions.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The CRE1 series, through hole variants (excluding surface mount variants) have been recognised by Underwriters Laboratory for functional insulation, both input and output should
normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part
should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the
isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier
between these circuits and any user-accessible circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The CRE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The CRE1 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum still air ambient temperature of 100°C for the C versions
and 130°C for the 3C versions as measured on the case of the unit (hotspot). The CRE1S0505MC is not currently UL recognised.
The CRE1 series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
CRE1S03xxS3C: 1A
CRE1S05xxxxC: 0.7A
CRE1S12xxSC: 0.2A
CRE1S24xxSC: 0.16A
All fuses should be UL recognised, 125V rated.
File number E151252 applies.
1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70°C.
www.murata-ps.com/support
KDC_CRE1.D01 Page 2 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
TEMPERATURE DERATING GRAPH- Surface Mount & 3C types
TEMPERATURE DERATING GRAPH - All other types1
85°C
85°C
1.0
1.0
Safe Operating Area
0
Safe Operating Area
120°C
150
0
-40
100
150
-40
100
0
50
0
50
Ambient Temperature (°C)
Ambient Temperature (°C)
EFFICIENCY VS LOAD
3.3V Inputs
5V Inputs
90
80
70
60
50
40
30
20
10
0
90
80
70
60
50
40
30
20
10
0
CRE1S0505XC
CRE1S0515SC
CRE1S0505S3C
CRE1S0505MC
CRE1S0505MEC
CRE1S0305S3C
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
12V Inputs
24V Inputs
90
80
70
60
50
40
30
20
10
0
90
80
70
60
50
40
30
20
10
0
CRE1S2405SC
CRE1S2412SC
CRE1S1205SC
CRE1S1212SC
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
1. 24V input parts prior to date code D1635 have operating temperature range of 0 to 70°C.
www.murata-ps.com/support
KDC_CRE1.D01 Page 3 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
TOLERANCE ENVELOPES
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
CRE1S0505XC
CRE1S0515SC
10%
7%
6%
3%
0%
0%
-3%
-6%
100
100
10
25
50
75
10
25
50
75
Output Load Current (%)
Output Load Current (%)
CRE1S1205SC
CRE1S1212SC
7%
5%
3%
2%
2%
1%
-1%
-6%
100
100
10
25
50
75
10
25
50
75
Output Load Current (%)
Output Load Current (%)
CRE1S2405SC
CRE1S2412SC
8%
5%
2%
0%
1%
-1%
-4%
-3%
100
100
10
25
50
75
10
25
50
75
Output Load Current (%)
Output Load Current (%)
www.murata-ps.com/support
KDC_CRE1.D01 Page 4 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
TOLERANCE ENVELOPES (continued)
CRE1S0305S3C
CRE1S0505S3C
9%
6%
7%
3%
1%
0%
-3%
-5%
100
100
10
25
50
75
10
25
50
75
Output Load Current (%)
Output Load Current (%)
CRE1S0505MC
CRE1S0505MEC
10%
7%
3%
3%
2%
0%
-4%
-8%
100
100
10
25
50
75
10
25
50
75
Output Load Current (%)
Output Load Current (%)
RoHS COMPLIANCE and MSL INFORMATION
The Through Hole parts (SIP/DIP) in this series are compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for
10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are
Matte Tin over Nickel Preplate. This series is backward compatible with Sn/Pb soldering systems.
The Surface Mount parts (MC/MEC) in this series are compatible with RoHS soldering systems as per J-STD-020D.1 The pin termination finish
on the Surface Mount package types is Matte Tin over Bickel Preplate. This series is backward compatible with Sn/Pb soldering systems. The
Surface Mount parts have a Moisture Sensitivity Level (MSL) 1.
Samples of the Surface Mount parts were tested in accordance with the conditioning described for MSL level 1 in IDC/J-STD-020D.1. The
products passed electrical tests and visual inspection criteria.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_CRE1.D01 Page 5 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Typical Start-Up Wave Form
Start-up time
μs
CRE1S0505DC
CRE1S0505SC
CRE1S0515SC
CRE1S1205SC
CRE1S1212SC
CRE1S2405SC
CRE1S2412SC
CRE1S0305S3C
CRE1S0505S3C
CRE1S0505MC
CRE1S0505MEC
190
190
1790
125
500
135
430
295
165
1368
170
www.murata-ps.com/support
KDC_CRE1.D01 Page 6 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
APPLICATION NOTES (continued)
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
C2
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100mꢀ at 100 kHz
C3
R1
100nF multilayer ceramic capacitor, general purpose
450ꢀ resistor, carbon film, 1% tolerance
R2
50ꢀ BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
DC/DC Converter
Differential Mode Noise Test Schematic
OSCILLOSCOPE
Y INPUT
R2
C1 C2 C3
R1
T1
+
+
Input
Output
SUPPLY
-
-
R LOAD
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
Load
C
DC
Inductor
SMD
Capacitor
C, μF
L, μH
Through Hole
CRE1S0505DC
CRE1S0505SC
CRE1S0515SC
CRE1S1205SC
CRE1S1212SC
CRE1S2405SC
CRE1S2412SC
CRE1S0305S3C
CRE1S0505S3C
CRE1S0505MC
CRE1S0505MEC
47
10
82473C
82103C
11R473C
11R103C
4.7
4.7
www.murata-ps.com/support
KDC_CRE1.D01 Page 7 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve B Quasi-Peak EMC limit, as shown in the following
plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits. The recom-
mended input capacitor to use for this circuit is 50V 16V X7R ceramic capacitor. For the CRE1S0505MEC an input inductor is not required.
L
DC
C
DC
Inductor
SMD
Capacitor
C, μF
Part Number
L, μH
Through Hole
CRE1S0505DC
CRE1S0505SC
CRE1S0515SC
CRE1S1205SC
CRE1S1212SC
CRE1S2405SC
CRE1S2412SC
CRE1S0305S3C
CRE1S0505S3C
CRE1S0505MC
CRE1S0505MEC
4.7
4.7
4.7
10
10
22
22
10
10
10
82472C
13R472C
13R472C
13R472C
13R103C
13R103C
13R223C
13R223C
13R103C
13R103C
13R103C
N/A
4.7
4.7
4.7
1
82472C
82472C
82103C
82103C
82223C
82223C
82103C
82103C
82103C
N/A
1
10
10
1
1
4.7
22
N/A
CRE1S0505XC
CRE1S0515SC
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
0
1.00E+05
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
CRE1S1205SC
CRE1S1212SC
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
0
1.00E+05
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
www.murata-ps.com/support
KDC_CRE1.D01 Page 8 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
EMC FILTERING AND SPECTRA
CRE1S2405SC
CRE1S2412SC
80
70
60
50
40
30
20
10
0
80
70
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
CRE1S0305S3C
CRE1S0505S3C
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
0
1.00E+05
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
CRE1S0505MC
CRE1S0505MEC
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
0
1.00E+05
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
www.murata-ps.com/support
KDC_CRE1.D01 Page 9 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
PACKAGE SPECIFICATIONS
SC Package
DC Package
3C Package
CRE1S
0505DC
XYYWW
11.53±±.2 [±.454±±.±±08
11.53±±.2 [±.454±±.±±08
CRE1S
CRE1S
0505SC
1±.±±±±.25 [±.394±±.±1±8
7.46±±.25 [±.294±±.±1±8
0505S3C
XYYWW
XYYWW
S
S
1
2
3
4
4.1±±±.5 [±.161±±.±2±8
1
2
3
4
4.1±±±.5 [±.161±±.±2±8
2.54 [±.1±±8
±.5±±±.±5 [±.±2±±±.±±28
±.25±±.±5 [±.±1±±±.±±28
2.54 [±.1±±8
±.5±±±.±5 [±.±2±±±.±±28
(1.95 [±.±778)
(2.21 [±.±078)
±.25±±.±5 [± .±1±±±.±±28
+±.15
-±.25
+±.±±6
±.24±
-±.±1±
+±.15
-±.2±
+±.±±6
±.24±
-±.±±0
(1.13 [±.±448)
6.1±
(1.13 [±.±448)
6.1±
[
8
[
8
All dimensions in mm (inches) Controlling dimension is mm.
All pins on a 2.54 (0.100) pitch and within 0.1 (0.004) of true position from pin 1 at seating plane ‘S’ (SC&3C)
All pins on a 2.54 (0.100) pitch and within 0.25 (0.010) of true position (DC)
Weight: 1.09g (3C) 1.30g (SC) 1.38g (DC)
PIN CONNECTIONS DC - 8 PIN DIP
PIN CONNECTIONS SC & 3C - 4 PIN SIP
Pin
1
Function
-VIN
Pin
1
Function
-VIN
4
+VIN
2
+VIN
5
+VOUT
-VOUT
3
-VOUT
7
4
+VOUT
www.murata-ps.com/support
KDC_CRE1.D01 Page 10 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
PACKAGE SPECIFICATIONS (Continued)
CRE1S0505MC
CRE1S0505MEC
12.70 0.20
(0.500 0.008)
12.70 (0.500)
7.62 (0.300)
7.62 (0.300)
14
8
DETAIL A
14
8
0.50 (0.020)
REFERENCE
PLANE
11.00 0.15
(0.433 0.006) (0.421 0.006)
10.70 0.15
CRE1S0505MEC
CRE1S0505MC
P
XYYWW
XYYWW
1.50 (0.059)
1.20 (0.047)
1
3
7
°
5.00
10 PINS
0.2 (0.008)
0.65 (0.026)
0.55 (0.022)
2.54 (0.100)
S
1
3
7
2.54 (0.100)
0.6 0.05 (0.024 0.002)
2.10 (0.083)
DETAIL A
SEATING
6.60 (0.260) 6.35 (0.250)
5.95 (0.234) 5.85 (0.230)
S
PLANE
+0.35
-0.10
+0.014
)
-0.004
7.05
(
0.278
0.30 (0.012)
0.20 (0.008)
0.25 (0.010)
0.10 (0.004)
(1.875 MAX)
2.79 (0.110) MAX
0.1(0.004) S
x5 Pins
0.10
0.25 0.05 (0.010 0.002)
1.56 0.10 (0.061 0.004)
0.2 (0.008) Min.
2.54 0.15 (0.100 0.006)
S
All dimensions in mm (inches) Controlling dimension is mm.
All pins on a 2.54 (0.100) pitch and within 0.25 (0.010) of true position
PIN CONNECTIONS - CRE1SXXXXMC/MEC
Pin
1
Function
-VIN
3
+VIN
7
-VOUT
+VOUT
NA
8
14
Weight: 1.2g
www.murata-ps.com/support
KDC_CRE1.D01 Page 11 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
PACKAGE SPECIFICATIONS (continued)
RECOMMENDED FOOTPRINT DETAILS
DC
SC/3C
2.54 [±.1±±8
x4 HOLES
1.15
1.±±
±.±45
Ø
±.±39
Ø
[
8
2.54 [±.1±±8
TUBE OUTLINE DIMENSIONS
DC Tube
12.± [±.4728
SC Tube
9.3 [±.3668
3C Tube
7.7 [±.3±38
9.3 [±.3668
12.43 [±.4098
14.0 [±.5038
14.5 [±.5718
10.± [±.7±98
5.±7±1.1± [±.2±±±±.±48
5.±5 [±.1998
4.45 [±.1758
5.± [±.1978
Unless otherwise specified all dimensions in mm [inches] 0.55mm [0.022].
Tube Length (DC&SC) : 520mm [20.472] 2.0 [0.079]
Tube Length (3C) : 525mm [20.669] 2.0 [0.079].
Tube Quantity (DC & SC): 35
(3C):40
www.murata-ps.com/support
KDC_CRE1.D01 Page 12 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
PACKAGE SPECIFICATIONS (continued)
RECOMMENDED FOOTPRINT DETAILS
7.62
(0.3)
2.00 (0.079)
9.70
(0.382)
2.54 (0.1)
1.00 (0.040) MIN
TUBE OUTLINE DIMENSIONS
CRE1S0505MC
CRE1S0505MEC
0.60 0.15 (0.024 0.006)
2.10 (0.083)
14.35 (0.565)
9.40 (0.370)
6.70 (0.264)
9.05 (0.36)
Unless otherwise specified all dimensions in mm [inches] 0.55mm [0.022].
Tube Length (MC&MEC) : 475 2.0 (18.70 0.07).
Tube Quantity (MC): 35
(MEC): 30
www.murata-ps.com/support
KDC_CRE1.D01 Page 13 of 14
CRE1 Series
Isolated 1W Single Output Isolated DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
330 2.0
(12.99 0.08)
13.25
(0.52)
0.60 (0.02) Max.
Ø100 (3.94)
+0.004 (+0.10)
-0.00 (-0.00)
1.50 (Ø0.06)
16.00 (0.63)
2.00
(0.08)
13.00 0.5
Ø
(0.51 0.02)
11.50
(0.45)
4.00
(0.16)
1.75(0.07)
11.50
(0.45)
24.00 0.30
(0.94 0.01)
8.10
(0.32)
REEL PACKAGING DETAILS
CARRIER TAPE START
100 (3.94) MIN
TRAILER SECTION
160 (6.30) MIN
GOODS ENCLOSURE
SECTION
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
LEADER SECTION
Reel Quantity: 500
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2017 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_CRE1.D01 Page 14 of 14
相关型号: