SC100-M20-R/400
更新时间:2024-09-18 23:18:59
品牌:MSYSTEM
描述:Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER
SC100-M20-R/400 概述
Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER
SC100-M20-R/400 数据手册
通过下载SC100-M20-R/400数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: SC100
/4: 400 mm
/6: 600 mm
Language
blank: Japanese
/E: English
Single Loop Controller Series
MULTI-FUNCTION PID CONTROLLER
(color LCD with touch-panel)
(Language (Japanese or English) can be chosen by front
panel setting.)
Configurator Interface
blank: Infrared
/1: Stereo jack
(If external noise interference is a concern, stereo jack
type is recommended.)
144
(5.67)
Terminal block
blank: One block terminal
/T: Separable terminal
*
mm (inch)
Other Options
*Selectable with option code
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
MODEL: SC100–[1]0–[2][3]
ORDERING INFORMATION
• Code number: SC100-[1]0-[2][3]
Specify a code from below for each [1] through [3].
(e.g. SC100-10-M2/3/E/1/T/Q)
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
• Specify the specification for option code /Q
(e.g. /C01/S01)
FUNCTIONS & FEATURES
Functions & Features
[1] DISCRETE OUTPUT
1: Relay contact
• Color LCD with touch panel
• Five Operation views (digital display, bargraph, dual-loop
bargraph, short trend and user's parameter table views)
• Enhanced screen functions for engineering (configuration,
programming and tuning views)
2: Photo MOSFET relay
MODBUS
0:None
• Universal input x 2 points, analog input x 4 points,
discrete input x 6 points, pulse input x 5 points, high speed
pulse input x 1 point
[2] POWER INPUT
AC Power
• Current output (4-20 mA) x 2 points, voltage output (1-5
V) x 2 points, relay or photo-MOSFET relay output x 5 points
• RUN contact output (relay) x 1 point
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
DC Power
• Computation cycle selectable between 50 msec. and 3
sec. (control cycle selectable between 1 and 64 times of the
computation cycle)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• Two PID function blocks
• Advanced computation and sequence control functions
• Auto-tuning function
[3] OPTIONS (multiple selections)
Housing Depth
• Parameter input and changing with touch panel
• Function parameter setting, list printing and data
downloading/uploading available with Loop Configuration
Builder Software (model: SFEW3E)
blank: 250 mm
/300: 300 mm (Discontinued, select /3)
/400: 400 mm (Discontinued, select /4)
/600: 600 mm (Discontinued, select /6)
/3: 300 mm
• Display parameter setting, saving and transfer with PC
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 1/10
http://www.m-system.co.jp/
MODEL: SC100
Configurator Software (model: SCCFG)
operations, time functions, signal selection, limit, alarm and
other functions
• Selectable housing depth for ease of using existing wires
in replacement: 250 mm, 300 mm, 400 mm and 600 mm
• Separable terminal block
Sequence operation: Logic sequence and step sequence
(max. 1068 commands)
Computation cycle: 50 msec. to 3 sec. (control cycle
selectable among 1, 2, 4, 8, 16, 32 and 64 times of the
computation cycle)
Typical Applications
• Replacement of conventional controllers
• Panel operation for small-scale instrumentation
MV output range: -15 - +115 %
Parameter setting: With touch panel or PC (Loop
Configuration Builder Software model: SFEW3E)
Self diagnostics: CPU monitoring with a watchdog timer
RUN contact: OFF in error detected by diagnostic
Infrared communication: Transmission distance max. 0.2
meter (for use with the COP-IRDA)
RELATED PRODUCTS
• PC Configurator cable (model: COP-US)
• Loop configuration builder software (model: SFEW3E Ver.
1.40 or later)
• Infrared communication adaptor (model: COP-IRDA)
• PC configurator software (model: SCCFG Ver.1.50 or later)
Builder software and configurator software are
downloadable at M-System’s web site.
■ Display
Display device: 4.3-inch TFT LCD
Display colors: 256
Resolution: 480 × 272 pixels
ACCESSORIES
• Precision resistor module (model: REM4): 2
Pixel pitch: 0.198 × 0.198 mm (128 × 128 DPI)
Backlight: LED
• Cold junction sensor: 2
Backlight life: Approx. 50 000 hours (at 50 % brightness)
Note: The backlight can be replaced in M-System factory.
The LCD must be replaced at the same time.
Screen saver standby time: 1 to 99 minutes
Scaling range: -32000 to +32000
• Mounting brackets: 2
• Connector adapter: 1
(included in Stereo jack type. The jack on the unit and the
plug of PC Configurator cable (not included in the product)
are different in size.)
Decimal point position: 10-1, 10-2, 10-3, 10-4, 10-5 or none
Scale divisions: 2 to 10
Engineering unit indication: Max. 8 characters
Auto/Man indicator: Green/Amber LED
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Degree of protection: IP55; ensured for the front panel of
the unit independently mounted to a panel
Connection
FACTORY DEFAULT
■ LOOP 1
P : 100%
Terminal screws: M3.5 screw terminals (torque 1.0 N·m)
Terminal fixing screws: M4 screw terminals (torque 1.2
N·m)
I : No integral action
D : No derivative action
CAS
PID
G02
H
L
Screw terminal
SEQ
G81
Reverse Action
Ai 1
Pv 1
Mv 1
Terminal screws: Nickel-plated steel (standard) or stainless
steel
(PV /MV
)
1
1
*
*
1 – 5 V DC
1 – 5 V DC
4 – 20 mA DC
Terminal fixing screws: Chrome-plated steel
Housing material: Flame-resistant resin (gray), steel
Isolation: Pv1 to Pv2 to supply output to Ai1 or Ai2 or Ai3 or
Ai4 to Di1 or Di2 or Di3 or Di4 or Di5 or Pi1 or Pi2 or Pi3 or
Pi4 or Pi5 to Di6 or Pi6 to Mv1 to Mv2 to Ao1 or Ao2 to Do1
to Do2 to Do3 to Do4 to Do5 to Do6 to power to FG
PID control: Single loop, cascade, advanced
Proportional band (P): 1 to 1000 %
AL1
AL2
■ LOOP 2
P : 100%
: No integral action
D : No derivative action
I
CAS
PID
G03
H
L
SEQ
G81
Reverse Action
Ai 2
Pv 2
Mv 2
(PV /MV
)
1
1
Integral time (I): 0.01 to 100 minutes
*
*
1 – 5 V DC
1 – 5 V DC
4 – 20 mA DC
Derivative time (D): 0.01 to 10 minutes
Auto-tuning: Limit cycle method
AL3
AL4
*1. Factory default setting
Use Loop Configuration Builder Software (model: SFEW3E)
to modify setting.
Alarm: PV high & low, deviation, rate of change
Computation: 48 functions blocks available for arithmetic
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 2/10
http://www.m-system.co.jp/
MODEL: SC100
Current limiting circuit: Approx. 30 mA
SUPPLY OUTPUT
Output voltage:
■ Di1, Di2, Di3, Di4, Di5: Dry contact
(Pi1 through Pi5 are assigned to the same terminals
respectively.)
24 V DC ±10 % with no load
18 V DC min. at 20 mA
Current rating: ≤ 22 mA DC
∙Shortcircuit protection
Current limited: Approx. 30 mA
Common: Negative common per 5 points
Sensing: Approx. 12 V DC, 6 mA
ON voltage/resistance: ≤ 2.25 V, ≤ 1.5 kΩ
OFF voltage/resistance: ≥ 11.25 V ≥ 15 kΩ
■ Di6: Dry contact
INPUT SPECIFICATIONS
■ Pv1, Pv2 (universal input)
(Pi6 is assigned to the same terminal.)
Common: Negative common
∙Current input: 4 – 20 mA DC with input resistance 250 Ω
(REM4)
Sensing: Approx. 12 V DC, 12 mA
ON voltage/resistance: ≤ 2 V, ≤ 1.5 kΩ
OFF voltage/resistance: ≥ 11 V, ≥ 15 kΩ
[Table 1 (Thermocouple input)]
∙Voltage input: -10 – +10 V DC
-1 – +1 V DC
0 – 10 V DC
USABLE
RANGE (°C)
CONFORMANCE
RANGE (°C)
1 – 5 V DC
T/C
K (CA)
0 – 1 V DC
-272 to +1472
-272 to +1100
-260 to +1300
-272 to +500
24 to 1920
-150 to +1370
-170 to +1000
-180 to +1200
-170 to +400
1000 to 1760
380 to 1760
400 to 1760
100 to 2315
-130 to +1300
-200 to +600
-200 to +900
0 to 1395
Input resistance: ≥ 1 MΩ
E (CRC)
∙Thermocouple input: K, E, J, T, B, R, S, C, N, U, L, P, PR (See
Table 1)
J (IC)
T (CC)
Input resistance: ≥ 30 kΩ
B (RH)
Burnout sensing: ≤ 0.3 µA
R
-100 to +1860
-100 to +1860
-52 to +2416
-272 to +1400
-252 to +700
-252 to +1000
-52 to +1496
-52 to +1860
Burnout indication: 115 % of the measuring range (upscale)
∙RTD input: Pt100 (JIS ’97, IEC), Pt100 (JIS ’89), JPt100 (JIS
’89), Pt50Ω (JIS ’81), Ni100 (See Table 2)
Maximum lead wire resistance: 100 Ω per wire
Burnout indication: 115 % of the measuring range (upscale)
Sensing current: ≤ 1 mA
S
C (WRe 5-26)
N
U
L
P (Platinel II)
(PR)
300 to 1760
∙Potentiometer input: Total resistance 100 Ω to 10 kΩ
Minimum span: 50 % of total resistance
Excitation: ≤ 0.6 V DC
Overrange input (out of the usable range) is handled as burnout.
[Table 2 (RTD input)]
■ Ai1, Ai2, Ai3, Ai4
USABLE
RANGE (°C)
CONFORMANCE
RANGE (°C)
RTD
∙Voltage input: 1 – 5 V DC
Pt 100 (JIS ’97, IEC
Pt 100 (JIS ’89)
JPt 100 (JIS ’89)
Pt 50Ω (JIS ’81)
Ni 100
)
-240 to +900
-240 to +900
-236 to +560
-236 to +700
-100 to +252
-200 to +850
-200 to +660
-200 to +510
-200 to +649
-80 to +250
Input resistance: ≥ 1 MΩ
■ Pi1, Pi2, Pi3, Pi4, Pi5: Dry contact
(Di1 through Di5 are assigned to the same terminals
respectively.)
Maximum frequency: 20 Hz
Overrange input (out of the usable range) is handled as burnout.
Minimum pulse width: 25 msec.
Common: Negative common per 5 points
Sensing: Approx. 12 V DC, 6 mA
ON voltage/resistance: ≤ 2.25 V, ≤ 1.5 kΩ
OFF voltage/resistance: ≥ 11.25 V ≥ 15 kΩ
■ Pi6: Dry contact
OUTPUT SPECIFICATIONS
■ Mv1, Mv2
∙Current output: 4 – 20 mA DC
Load resistance: ≤ 600 Ω
■ Ao1, Ao2
(Di6 is assigned to the same terminal.)
Maximum frequency: 10 kHz
∙Voltage output: 1 – 5 V DC
Load resistance: ≥ 10 kΩ
■ Discrete Output
Minimum pulse width: 0.05 msec.
Common: Negative common
Sensing: Approx. 12 V DC, 12 mA
ON voltage/resistance: ≤ 2 V, ≤ 1.5 kΩ
OFF voltage/resistance: ≥ 11 V, ≥ 15 kΩ
Excitation: 12 V DC ±10%, 15 mA
∙Do1, Do2, Do3, Do4, Do5, RUN contact (Do6): Relay
contact
Rated load: 250 V AC @1 A (cos ø = 1)
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 3/10
http://www.m-system.co.jp/
MODEL: SC100
30 V DC @1 A (resistive load)
RAM memory duration in power failure for hot start:
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 60 W
Minimum load: 5 V DC @10 mA
10 minutes assured
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength:
Mechanical life: 2 × 10
7
cycles
1500 V AC @ 1 minute
∙Do1, Do2, Do3, Do4, Do5: Photo MOSFET relay
Rating: 200 V AC/DC @0.5 A (resistive load)
ON resistance: 2.1 Ω
(Pv1 or supply output to Pv2 or Ai1 or Ai2 or Ai3 or Ai4 to
Di1 or Di2 or Di3 or Di4 or Di5 or Pi1 or Pi2 or Pi3 or Pi4 or
Pi5 to Di6 or Pi6 to Mv1 to Mv2 or Ao1 or Ao2 to Do1 to Do2
or Do3 or Do4 or Do5 or Do6 to power to FG)
500 V AC @ 1 minute (Pv2 to Ai1 or Ai2 or Ai3 or Ai4)
500 V AC @ 1 minute (Mv2 to Ao1 or Ao2)
500 V AC @ 1 minute (Do2 to Do3 to Do4 to Do5 to Do6)
500 V AC @ 1 minute (Pv1 to supply output)
Maximum frequency: 4 Hz @24 V, 10 mA
ON delay time: ≤ 5.0 msec.
OFF delay time: ≤ 3.0 msec.
INSTALLATION
Power input
∙AC:
STANDARDS & APPROVALS
EU conformity:
≤ 25 VA at 100 V AC
≤ 40 VA at 240 V AC
EMC Directive
•DC: ≤ 650 mA
EMI EN 61000-6-4
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 5 to 90 %RH (non-condensing)
Mounting: Panel flush mounting (high-density mounting in
horizontal direction)
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Measurement Category II (contact output)
Installation Category II (power)
Pollution degree 2
Weight:
Approx. 1.8 kg (3.97 lb) for 250 mm depth type
Approx. 2.0 kg (4.41 lb) for 300 mm depth type
Approx. 2.5 kg (5.51 lb) for 400 mm depth type
Approx. 3.0 kg (6.61 lb) for 600 mm depth type
Input or output to contact output – Basic insulation (300
V)
Input or output to power - Reinforced insulation (300 V)
RoHS Directive
EN 50581
PERFORMANCE in percentage of max. span
Accuracy
Protection against access to the terminal blocks:
Finger protection (VDE 0660-514)
DC input: ±0.1 % ±1 digit
Thermocouple input: ±1℃ ±1 digit
±2℃ ±1 digit for B, R, S, C and PR
RTD input: ±1℃ ±1 digit
Potentiometer input: ±0.2 % ±1 digit
DC output: ±0.1 %
Precision resistor module (REM4): ±0.1 %
Cold junction compensation:
±2°C at 25°C ±10°C
±4°C for S, R and PR
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
DC input: ±0.015 %/°C (±0.008 %/°F)
Thermocouple input: ±0.015 %/°C (±0.008 %/°F)
RTD input: ±0.015 %/°C (±0.008 %/°F)
Potentiometer input: ±0.015 %/°C (±0.008 %/°F)
DC output: ±0.015 %/°C (±0.008 %/°F)
Precision resistor module (REM4): ±0.015 %/°C (±0.008
%/°F)
Line voltage effect: ±0.1 % over voltage range
Calendar clock accuracy: Monthly deviation 3 minutes at
25°C
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 4/10
http://www.m-system.co.jp/
MODEL: SC100
EXTERNAL VIEW
■ CONTROL MODULE FRONT VIEW
• Infrared communication type
• Stereo jack type
1
1
Auto/Man
Auto/Man
2
7
3
5
6
4
6
3
4
5
1. TFT Color LCD with touch panel
Provides operation and engineering views to facilitate monitoring and setting
2. Infrared communication port
Used to communicate with PC via IRDA Communication Adaptor (model: COP-IRDA) to program and change parameters
using Loop Configuration Builder Software (model: SFEW3E) or PC Configurator Software (model: SCCFG)
3. MV value (DOWN) button
4. Acceleration button
(Accelerates MV signal’s changing speed by pressing simultaneously with MV value button)
5. MV value (UP) button
6. Auto / Man selector (changes the control mode for MV output)
7. Configurator jack and cap
Connects with a PC where Loop Configuration Builder Software (model: SFEW3E) or PC configurator software (model: SCCFG)
is installed via a PC configurator cable (model: COP-US) and enables programming and parameter setting
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 5/10
http://www.m-system.co.jp/
MODEL: SC100
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■ INFRARED COMMUNICATION TYPE
175 (6.89)
210 (8.27) max.
• ONE BLOCK TERMINAL
(without option /T)
MOUNTING BRACKETS
TERMINAL COVER
52–M3.5 SCREW
14
40
41
42
43
44
45
46
47
48
49
50
51
52
1
27
28
29
30
31
32
33
34
35
36
37
38
39
15
2
16
3
17
4
18
5
19
6
20
7
21
8
22
9
23
10
24
11
25
12
26
13
72 (2.83)
24
*1
67.5 (2.66)
(.94)
• SEPARABLE TERMINAL
(with option /T)
*1. Standard model: 250 mm (9.84”)
Option /3:
Option /4:
Option /6:
300 mm (11.81”)
400 mm (15.75”)
600 mm (23.62”)
52–M3.5 SCREW
4–M4 SCREW FOR
FIXING TERMINAL
14
1
40
41
42
43
44
45
46
47
48
49
50
51
52
27
28
29
30
31
32
33
34
35
36
37
38
39
15
2
16
3
17
4
18
5
19
6
20
7
21
8
22
9
23
10
24
11
25
12
26
13
67.5 (2.66)
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 6/10
http://www.m-system.co.jp/
MODEL: SC100
■ STEREO JACK TYPE
175 (6.89)
210 (8.27) max.
• ONE BLOCK TERMINAL
(without option /T)
MOUNTING BRACKETS
TERMINAL COVER
52–M3.5 SCREW
14
15
16
17
18
19
20
21
22
23
24
25
26
40
41
42
43
44
45
46
47
48
49
50
51
52
1
27
28
29
30
31
32
33
34
35
36
37
38
39
2
3
4
5
6
7
8
9
10
11
12
13
Jack cap
1 (.04)
72 (2.83)
24
*1
67.5 (2.66)
(.94)
• SEPARABLE TERMINAL
(with option /T)
*1. Standard model: 250 mm (9.84”)
Option /3:
Option /4:
Option /6:
300 mm (11.81”)
400 mm (15.75”)
600 mm (23.62”)
52–M3.5 SCREW
4–M4 SCREW FOR
FIXING TERMINAL
14
1
40
41
42
43
44
45
46
47
48
49
50
51
52
27
28
29
30
31
32
33
34
35
36
37
38
39
15
2
16
3
17
4
18
5
19
6
20
7
21
8
22
9
23
10
24
11
25
12
26
13
67.5 (2.66)
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 7/10
http://www.m-system.co.jp/
MODEL: SC100
MOUNTING REQUIREMENTS unit: mm
■ PANEL CUTOUT unit: mm
• Single mounting
• Clustered mounting
[68+72×(n - 1)] +1
68 +0.7
0
0
n = number of units
Panel thickness 2.3 – 20
■ Caution
• IP55 is ensured for the front panel of the unit mounted independently according to a panel. Test the sealing at the mounting
surface once the device is installed.
• Set the unit on a vertical surface with its operation buttons at the lower side. Mounting in other directions may cause heat
built up inside the unit and shorten its life span or degrade its performance.
• Ensure that there is sufficient space for ventilation inside a panel. Do not install above the devices that generate high heat
such as heaters, transformers or resistors. Leave at least 30 mm (1.2 inch) space above, below and behind the unit for
maintenance purpose (e.g. wiring, removing or installing).
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 8/10
http://www.m-system.co.jp/
MODEL: SC100
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.
Isolation
+
+
+
+
34
35
36
37
16
17
18
19
20
21
22
23
24
25
10
11
3
Discrete
Input
Circuit
Di 1 / Pi 1
Di 2 / Pi 2
Di 3 / Pi 3
Di 4 / Pi 4
Di 5 / Pi 5
Do 1
Do 2
Do 3
Do 4
Do 5
+
–
38
39
Isolation
Sensor
Excitation
SENSOR EXC
31
Di 6 /Pi 6
Digital
Input
Circuit
Computation
INPUT
COM
32
33
Do 6
RUN CONTACT
Isolation
Isolation
Isolation
Isolation
Isolation
Isolation
Output
Driver
A1 42
B1 43
C1 44
A2 45
B2 46
C2 47
+
–
+
–
+
A/D
Converter
Mv 1
Mv 2
Pv 1
UNIVERSAL INPUT
4
Output
Driver
5
6
A/D
Converter
Pv 2
UNIVERSAL INPUT
Output
Driver
7
Ao 1
Ao 2
Output
Driver
+
+
+
+
–
48
49
50
8
9
A/D
Converter
Ai 1
Ai 2
Ai 3
Ai 4
12 U(+)
POWER
13 V(–)
+
–
51
52
26 FG
40
Isolation
27
Excitation
Supply
+
–
29
30
28
2-WIRE TRANSMITTER
41
PC CONFIGURATOR/
BUILDER SOFTWARE
Infrared Port / Jack
1
Display /
Setting
14
15
2
■ DISCRETE INPUT PULSE
INPUT CONNECTION E.G.:
+12V
■ UNIVERSAL INPUT CONNECTION E.G.
POTENTIOMETER
max.
RTD
A
B
B
3
2
1
+
+
–
+
–
A
A
B
A
B
C
A
29
30
A
Dry contact
2-Wire
XMTR
T/C
1 or 2kΩ
*3
+
–
+
B
C
B
C
+
–
VOLT / CURRENT
INPUT
R
–
–
C
min.
CJC SENSOR
B
*4
*5
R
*3. Connect input resistor module (model: REM4) for current input.
*4. Connect CJC sensor for thermocouple input.
C
*5. Connect input resistor module (model: REM4).
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 9/10
http://www.m-system.co.jp/
MODEL: SC100
SYSTEM CONFIGURATION EXAMPLES
■ SINGLE LOOP CONTROL
■ CASCADE CONTROL
Multi-Function PID Controller
Model: SC100
Multi-Function PID Controller
Model: SC100
Ai
PV
PV
MV
MV
Flow
Level
Specifications are subject to change without notice.
SC100 SPECIFICATIONS
ES-6337 Rev.16 Page 10/10
http://www.m-system.co.jp/
SC100-M20-R/400 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
SC100-M20-R/6 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-M20-R/600 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/3 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/300 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/4 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/400 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/6 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-M2/600 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-R/3 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 | |
SC100-R0-R/300 | MSYSTEM | Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER | 获取价格 |
SC100-M20-R/400 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6