MODEL: R8-DCT4D  
Remote I/O R8 Series  
GENERAL SPECIFICATIONS  
Connection  
Output: Tension clamp  
Applicable wire size: 0.2 - 2.5 mm  
Stripped length: 10 mm  
Excitation supply, internal bus:  
RELAY OUTPUT MODULE  
(4 points, Tension clamp terminal block)  
Functions & Features  
2
• 4 channels for relay output, compact size remote I/O  
module  
Connected to internal bus connector  
Internal power: Via bus connector  
• 8 pins tension clamp connector  
Isolation: Output 1 to output 2 to output 3 to output 4 to  
exc. supply to internal bus or internal power  
Module address: With DIP switch  
24 (.94)  
Output at the loss of communication: Selectable with the  
side DIP SW  
Terminating resistor: Built-in (DIP Switch, default: disable)  
Status indicator: Bi-color (red/green) LED; Refer to the  
instruction manual.  
115 (4.53)  
Discrete output status indicators: Green LED; Refer to the  
instruction manual.  
73 (2.87)  
mm (inch)  
OUTPUT SPECIFICATIONS  
Output: Relay contact 4 points  
Output common: Common per one point (4 terminals)  
Maximum load current: 2 A per point  
Rated load: 250 V AC @2 A (cos ø = 1)  
30 V DC @2 A (resistive load)  
MODEL: R8–DCT4D[1]  
ORDERING INFORMATION  
• Code number: R8-DCT4D[1]  
Specify a code from below for [1].  
(e.g. R8-DCT4D/Q)  
Maximum switching voltage: 250 V AC or 30 V DC  
Maximum switching power: 500 VA or 60 W  
Minimum load: 5 V DC @1 mA  
Mechanical life: 2 × 10 cycles (rate 300/min.)  
7
• Specify the specification for option code /Q  
(e.g. /C01)  
When driving an inductive load, external contact protection  
and noise quenching are recommended.  
ON delay: ≤ 10 msec.  
[1] OPTIONS  
OFF delay: ≤ 10 msec.  
blank: none  
/Q: With options (specify the specification)  
INSTALLATION  
Max. current consumption: 100 mA  
Exc. supply current consumption: 40 mA  
Operating temperature: -10 to +55°C (14 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
Weight: 120 g (0.26 lb)  
RELATED PRODUCTS  
• PC configurator software (model: R8CFG)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
PERFORMANCE  
Data allocation: 1  
Module addresses in use: 1  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength:  
1500 V AC @ 1 minute (output 1 to output 2 to output 3 to  
output 4 to exc. supply to internal bus or internal power to  
ground)  
R8-DCT4D SPECIFICATIONS  
ES-9798 Rev.1 Page 1/4  
https://www.m-system.co.jp/  
MODEL: R8-DCT4D  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1, EN 61010-2-201  
Measurement Category II (output)  
Pollution Degree 2  
Output to exc. supply or internal bus or internal power:  
Basic insulation (250 V)  
RoHS Directive  
EXTERNAL VIEW  
FRONT VIEW  
SIDE VIEW  
Status Indicator LED  
DIP SW  
Discrete Output  
RUN  
Status Indicator LED  
1
2
3
4
SW1  
SW2  
8
7
6
5
4
3
2
1
Internal Bus Connector  
Output Connectors  
On  
Do  
1
8
R8-DCT4D SPECIFICATIONS  
ES-9798 Rev.1 Page 2/4  
https://www.m-system.co.jp/  
MODEL: R8-DCT4D  
OPERATING MODE SETTING  
(*) Factory setting  
Caution ! - SW2-1 through 2-7 are unused. Be sure to turn  
off unused ones.  
Module Address  
SW1-1 through 1-4 determine the tenth place digit, while  
SW1-5 through 1-8 do the ones place digit of the module  
address.  
Address is selected between 0 to 31.  
(Factory setting: 0)  
SW1  
MODULE ADDRESS  
×10  
×1  
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
9
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
Output at the Loss of Communication  
SW2  
OUTPUT AT THE LOSS OF COMMUNICATION  
5
Output Hold (*)  
OFF  
(last data correctly received is hold)  
Stop output (Output !xed at OFF)  
ON  
Terminator DIP SW  
SW2  
TERMINATOR SW  
6
Without (*)  
OFF  
ON  
With  
Con!guration Mode  
SW2  
8
CONFIGURATION MODE  
DIP switch setting (*)  
OFF  
ON  
PC Configurator and communication  
R8-DCT4D SPECIFICATIONS  
ES-9798 Rev.1 Page 3/4  
https://www.m-system.co.jp/  
MODEL: R8-DCT4D  
DIMENSIONS unit: mm (inch)  
73 (2.87)  
55 (2.17)  
[4 (.16)]  
24 (.94)  
[3 (.12)]  
DIN RAIL  
(35 mm wide)  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
STATUS  
OUTPUT  
LED STATUS LED  
+24V  
Isolation  
Ry  
OUTPUT  
CONNECTOR  
Comm.  
Circuit  
INTERNAL BUS  
Control  
Circuit  
1
2
Do 1  
Do 2  
Do 3  
Do 4  
Ry  
Ry  
Ry  
INTERNAL POWER  
DIP SW  
3
4
+24V  
0V  
Output  
Circuit  
EXC. SUPPLY  
5
6
7
8
0V  
Specifications are subject to change without notice.  
R8-DCT4D SPECIFICATIONS  
ES-9798 Rev.1 Page 4/4  
https://www.m-system.co.jp/  

相关型号:

R8-FST4N

Remote I/O R8 Series DC VOLTAGE/CURRENT INPUT MODULE
MSYSTEM

R8-FST4N/Q

Remote I/O R8 Series DC VOLTAGE/CURRENT INPUT MODULE
MSYSTEM

R8-NC3

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NC3-R

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NC3-R/Q

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NEIP-R

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NEIP-R/Q

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NEIP1

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1-R

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-NM1-R/Q

Remote I/O R8 Series POWER/NETWORK MODULE
MSYSTEM

R8-PA4

Remote I/O R8 Series TOTALIZED PULSE INPUT MODULE, 4 points
MSYSTEM