R7FN-DA16-R [MSYSTEM]

Remote I/O R7 Series FLEX NETWORK I/O MODULE;
R7FN-DA16-R
型号: R7FN-DA16-R
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R7 Series FLEX NETWORK I/O MODULE

文件: 总6页 (文件大小:158K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R7FN-DA16  
Remote I/O R7 Series  
GENERAL SPECIFICATIONS  
Connection: M3 separable screw terminal (torque 0.5 N·m)  
Solderless terminal: Refer to the drawing at the end of the  
section.  
FLEX NETWORK I/O MODULE  
(Discrete input, 16 points)  
Communication cable  
Functions & Features  
Recommended manufacture: Japan Solderless Terminal  
MFG.Co.Ltd  
• 16 points discrete input module for FLEX NETWORK  
Applicable wire size: 0.2 to 0.5 mm  
2
(AWG 26 to 22)  
FLEX NETWORK is registered trademark of Digital  
Electronics Corporation in Japan.  
Others  
Recommended manufacture: Japan solderless terminal  
MFG.Co.Ltd, Nichifu Co.,ltd  
Applicable wire size: 0.25 to 1.65 mm  
2
(AWG 22 to 16)  
115 (4.53)  
Screw terminal: Nickel-plated steel  
Housing material: Flame-resistant resin (gray)  
Isolation: Input to FLEX NETWORK to power to FG  
Status indicator LED: PWR, RUN  
53 (2.09)  
(Refer to the instruction manual)  
54 (2.13)  
Discrete input status indicator LED: LED turns on with input  
ON  
mm (inch)  
■Recommended solderless terminal  
MODEL:R7FN–DA16-R[1]  
3.3 (.13) max  
ORDERING INFORMATION  
• Code number: R7FN-DA16-R[1]  
Specify a code from below for [1].  
(e.g. R7FN-DA16-R/Q)  
mm (inch)  
• Specify the specification for option code /Q  
(e.g. /C01/SET)  
FLEX NETWORK COMMUNICATION  
Communication configuration: 1: N  
Connection method: Multi-drop Connection  
Communication method: Cyclic Time Division, half-duplex  
Communication I/F: Differential, pulse transfer isolation  
Error Check: Format, bit, CRC-12 verification  
Max. Number of Nodes: 63 (1008 I/O points)  
Required node: 1  
I/O TYPE  
DA16: Discrete input, 16 points  
POWER INPUT  
DC Power  
Network cable: Pro-face’s following cable  
FN-CABLE2010-31-MS (10 m)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
FN-CABLE2050-31-MS (50 m)  
FN-CABLE2200-31-MS (200 m)  
[1] OPTIONS  
blank: none  
Transmission distance: 12 Mbps: 100 meters (328 ft) (*)  
6 Mbps: 200 meters (656 ft)  
/Q: Options other than the above (specify the specification)  
(*) Factory default setting  
Station address: Rotary switch  
(Refer to the instruction manual)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Terminating resistor: Built-in  
/C02: Polyurethane coating  
INPUT SPECIFICATIONS  
Common: Positive or negative common (NPN/PNP) per 16  
/C03: Rubber coating  
EX-FACTORY SETTING  
points  
/SET: Preset according to the Ordering Information Sheet  
(No. ESU-7808-DA16)  
Maximum inputs applicable at once: No limit (at 24 V DC)  
Rated input voltage: 24 V DC ±10 %; ripple 5 %p-p max.  
ON voltage / current: ≥ 15 V DC (input – COM) / ≥ 3.5 mA  
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 1/6  
http://www.m-system.co.jp/  
MODEL: R7FN-DA16  
OFF voltage / current: ≤ 5 V DC (input – COM) / ≤ 1 mA  
Input current: ≤ 5.5 mA per point at 24 V DC  
Input resistance: Approx. 4.4 kΩ  
ON delay: ≤ 2.0 msec.  
OFF delay: ≤ 2.0 msec.  
INSTALLATION  
Current consumption  
DC: Approx. 50 mA  
Operating temperature: -10 to +55°C (14 to 131°F)  
Storage temperature: -20 to +65°C (-4 to +149°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: DIN rail (35 mm rail)  
Weight: 200 g (0.44 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute (input to FLEX  
NETWORK to power to FG)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
EN 50581  
EXTERNAL VIEW  
Operating Mode Setting DIP SW (SW1)  
Station Address Setting Rotary SW  
Status Indicator LED  
Discrete Input Status Indicator LED  
ON  
2 3 4 5 6 7 8  
1
X10  
8
X1  
8
PWR RUN  
0
1 2 3 4 5 6 7 8 9 A B C D E F  
STATION ADD.  
4
5
6
7
10 11 12 13 14 15 16 17 18  
1
2
3
1
2
3
4
5
6
7
8
9
FLEX NETWORK,  
Power Supply Terminals  
Input Terminals  
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 2/6  
http://www.m-system.co.jp/  
MODEL: R7FN-DA16  
CONNECTION DIAGRAMS  
MASTER CONNECTION  
Master Station  
Slave Station  
Slave Station  
+
+
+
TR  
TR  
TR  
Terminating  
Resistor  
TR  
TR  
TR  
+
+
SHIELD  
JP  
JP  
JP  
JP  
Terminating  
Short Bar  
FG  
FG  
Note: Be sure to use the terminator(s) located at both ends of the modules.  
TERMINAL ASSIGNMENTS  
■ INPUT TERMINAL ASSIGNMENT  
10  
11  
X1  
12  
X3  
13  
X5  
14  
X7  
15  
X9  
16  
XB  
17  
XD  
18  
XF  
COM  
1
2
3
4
5
6
7
8
9
COM  
X0  
X2  
X4  
X6  
X8  
XA  
XC  
XE  
NO. ID  
FUNCTION  
NO. ID  
FUNCTION  
1
2
3
4
5
6
7
8
9
COM Common  
10 COM Common  
X0  
X2  
X4  
X6  
X8  
Input 0  
Input 2  
Input 4  
Input 6  
Input 8  
11  
12  
13  
14  
15  
16  
17  
18  
X1 Input 1  
X3 Input 3  
X5 Input 5  
X7 Input 7  
X9 Input 9  
XB Input 11  
XD Input 13  
XF Input 15  
XA Input 10  
XC Input 12  
XE Input 14  
NETWORK, POWER SUPPLY TERMINAL ASSIGNMENT  
4
5
6
7
-
TR+ TR +24V 0V  
1
2
3
-
JP+ JP  
FG  
NO.  
1
ID  
JP+  
JP–  
FG  
FUNCTION, NOTES  
Terminating resistor  
Terminating resistor  
FG  
2
3
4
TR+  
TR–  
+24V  
0V  
Network  
5
Network  
6
Power input (24V DC)  
Power input (0V)  
7
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 3/6  
http://www.m-system.co.jp/  
MODEL: R7FN-DA16  
I/O DATA DESCRIPTIONS  
DISCRETE INPUT  
• Di  
• Do  
15  
0
15  
0
Unused  
Input 0  
Input 1  
Input 2  
Input 3  
:
:
Input 7  
Input 8  
:
Input 15  
0: OFF  
1: ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
115 (4.53)  
17 (.66)  
54 (2.13)  
DIN RAIL  
35mm wide  
4
5
6
7
10 11 12 13 14 15 16 17 18  
1
2
3
1
2
3
4
5
6
7
8
9
30 (1.18)  
[5 (.20)]  
6 (.24)  
6 (.24)  
7–M3 SCREW  
TERMINALS  
for FLEX NETWORK, POWER  
18–M3 SCREW  
TERMINALS  
for INPUT  
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 4/6  
http://www.m-system.co.jp/  
MODEL: R7FN-DA16  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Note: In order to improve EMC performance, bond the FG terminal to ground.  
Caution: FG terminal is NOT a protective conductor terminal.  
Input Circuit  
Isolation  
4
5
TR+  
TR–  
1
10  
2
COM  
COM  
X0  
Comm.  
Circuit  
1
2
3
6
7
JP+  
JP–  
3
X2  
4
X4  
FG  
5
X6  
24V DC  
0V  
6
X8  
7
XA  
XC  
XE  
X1  
8
Control  
Circuit  
9
11  
12  
13  
14  
15  
16  
17  
18  
X3  
X5  
X7  
X9  
XB  
XD  
XF  
Input Circuit  
1
10  
2
COM  
COM  
X0  
Control  
Circuit  
18  
XF  
Input Connection Example  
PNP Connection  
NPN Connection  
+
+
1
10  
2
1
10  
2
COM  
COM  
X0  
COM  
COM  
X0  
18  
18  
XF  
XF  
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 5/6  
http://www.m-system.co.jp/  
MODEL: R7FN-DA16  
Specifications are subject to change without notice.  
R7FN-DA16 SPECIFICATIONS  
ES-7808-F Rev.0 Page 6/6  
http://www.m-system.co.jp/  

相关型号:

R7FN-DA16-R/Q

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16A

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16A-R

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16A-R/Q

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16B

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16B-R

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DAC16B-R/Q

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DC16A

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DC16A-R

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DC16A-R/Q

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DC16B

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM

R7FN-DC16B-R

Remote I/O R7 Series FLEX NETWORK I/O MODULE
MSYSTEM