R7F4HEIP-DC16A [MSYSTEM]

Remote I/O R7F4HEIP Series EtherNet/IP I/O MODULE;
R7F4HEIP-DC16A
型号: R7F4HEIP-DC16A
厂家: M-SYSTEM    M-SYSTEM
描述:

Remote I/O R7F4HEIP Series EtherNet/IP I/O MODULE

文件: 总5页 (文件大小:522K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: R7F4HEIP-DC16A  
Remote I/O R7F4HEIP Series  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
EtherNet/IP I/O MODULE  
(NPN transistor output, 16 points, tension clamp terminal  
block)  
/C02: Polyurethane coating  
/C03: Rubber coating  
Functions & Features  
• 16 points NPN transistor output module for EtherNet/IP  
• Supports DLR (Device Level Ring) to form a ring topology  
RELATED PRODUCTS  
• PC configurator software (model: R7CFG)  
• EDS file  
The EDS file and configurator software are downloadable at  
M-System’s web site.  
115 [4.53]  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
55 [2.17]  
GENERAL SPECIFICATIONS  
Connection  
72 [2.83]  
mm [inch]  
EtherNet/IP: RJ-45 Modular Jack  
Power supply, exc. supply, output: Tension clamp terminal  
Housing material: Flame-resistant resin (gray)  
Isolation: Output or exc. supply to EtherNet/IP or FE to  
power  
MODEL: R7F4HEIP-DC16A-4-R[1]  
ORDERING INFORMATION  
• Code number: R7F4HEIP-DC16A-4-R[1]  
Specify a code from below for [1].  
(e.g. R7F4HEIP-DC16A-4-R/Q)  
Output at the loss of communication: Configurable via  
R7CFG  
Status indicator LED: PWR, LNK1, LNK2  
(Refer to the instruction manual)  
Discrete output status indicator LED: Green LED turns on  
with output ON  
• Specify the specification for option code /Q  
(e.g. /C01)  
I/O TYPE  
DC16A: NPN transistor output, 16 points  
EtherNet/IP COMMUNICATION  
Communication Standard: IEEE 802.3u  
Transmission: 10BASE-T, 100BASE-TX  
Baud rate: 10/100 Mbps (Auto Negotiation function)  
Protocol: EtherNet/IP  
TERMINAL BLOCK: 4  
Tension clamp terminal block for power supply  
RJ-45 Modular jack for communication  
Tension clamp terminal block for I/O  
Max. number of socket connections: 3  
Connection type: Exclusive owner / Listen only / Input only  
Transmission media: 10BASE-T (STP, Category 5), 100BASE-  
TX (STP, Category 5e)  
POWER INPUT  
DC power  
Network topology: Line, star and ring  
Max. length of fieldbus segment: 100 meters  
IP address: 192.168.0.250 (factory setting);  
Only host address in IP address is configurable via rotary  
switches, the other items via PC configurator software  
(model: R7CFG).  
R: 24 V DC  
(Operational voltage range: ±10 %; ripple 10 %p-p max.)  
[1] OPTIONS  
blank: none  
DLR supported  
/Q: With options (specify the specification)  
Port No.: 2222, 44818  
I/O data size: One (1) word  
Status indicator LEDs: MS, NS (Refer to the instruction  
manual for details)  
R7F4HEIP-DC16A SPECIFICATIONS  
ES-8005-B Rev.0 Page 1/5  
https://www.m-system.co.jp/  
MODEL: R7F4HEIP-DC16A  
OUTPUT SPECIFICATIONS  
Common: Negative common (NPN) per 8 points  
Number of output: 16 points  
PC CONFIGURATOR  
The following parameters can be set with using PC  
Configurator Software (model: R7CFG)  
Refer to the users manual for the R7CFG for detailed  
operation of the software program.  
Maximum outputs applicable at once: No limit (at 24 V DC)  
Rated load voltage: 24 V DC ±10 %, ripple 5 %p-p max.  
Rated output current: 0.1 A per point, 0.8 A per common  
Residual voltage: ≤ 1.2 V  
CHANNEL BATCH SETTING  
PARAMETER  
SETTING RANGE  
DEFAULT  
Hold  
Output Hold / Clear  
Hold / Clear  
Leakage current: ≤ 0.1 mA  
ON delay: ≤ 0.2 msec.  
EtherNet SETTING  
OFF delay: ≤ 0.5 msec.  
PARAMETER  
SETTING RANGE  
DEFAULT  
192.168.0.250  
255.255.255.0  
192.168.0.1  
30 (0.1 sec.)  
Overload current protection function: Limits the current  
value when overcurrent is detected  
IP Address  
0.0.0.0 - 255.255.255.255  
0.0.0.0 - 255.255.255.255  
Subnet Mask  
Default Gateway 0.0.0.0 - 255.255.255.255  
TimeOut 0 - 32767 (0.1 sec.)  
Overheat protection function: Turns OFF the outputs when  
overheat is detected  
(When driving an inductive load, connect a diode in parallel  
with the load.)  
INSTALLATION  
Current consumption  
DC: Approx. 70 mA  
(contact I/O load charge is not included)  
Operating temperature: -10 to +55°C (14 to 131°F)  
Storage temperature: -20 to +65°C (-4 to +149°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Atmosphere: No corrosive gas or heavy dust  
Mounting: Surface or DIN rail (35 mm rail)  
Weight: 170 g (0.37 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 1500 V AC @ 1 minute  
(output or exc. supply to EtherNet/IP or FE to power)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
RoHS Directive  
R7F4HEIP-DC16A SPECIFICATIONS  
ES-8005-B Rev.0 Page 2/5  
https://www.m-system.co.jp/  
MODEL: R7F4HEIP-DC16A  
EXTERNAL VIEW  
IP Address Setting Rotary SW  
Status Indicator LED  
PC Con!gurator Jack  
RJ-45 Modular Jack  
Discrete Output Status Indicator LED  
Power Supply Connector  
Sensor Exc. / Output Connectors  
TERMINAL ASSIGNMENTS  
■SENSOR EXC. / OUTPUT CONNECTION  
Applicable connector: DFMC0,5/13-ST-2,54 (Phoenix Contact) (included in the package)  
Applicable wire size: 0.14  
0.5mm2, stripped length 7mm  
-
Recommended solderless terminal:  
· AI0,14-6GY 0.14mm2 (Phoenix Contact)  
· AI0,25-6YE 0.25mm2 (Phoenix Contact)  
· A0,34-7 0.34mm2 (Phoenix Contact)  
1
2
3
4
5
6
7
8
9 10 11 12 13 27 28 29 30 31 32 33 34 35 36 37 38 39  
14 15 16 17 18 19 20 21 22 23 24 25 26 40 41 42 43 44 45 46 47 48 49 50 51 52  
PIN No.  
ID  
FUNCTION  
24V DC  
Output 0  
24V DC  
0V  
PIN No.  
27  
ID  
FUNCTION  
24V DC  
Output 8  
24V DC  
0V  
1
2
+24V1  
Y0  
+24V2  
Y8  
28  
3
+24V1  
GND1  
Y2  
29  
+24V2  
GND2  
Y10  
4
30  
5
Output 2  
24V DC  
0V  
31  
Output 10  
24V DC  
0V  
6
+24V1  
GND1  
Y4  
32  
+24V2  
GND2  
Y12  
7
33  
8
Output 4  
24V DC  
0V  
34  
Output 12  
24V DC  
0V  
9
+24V1  
GND1  
Y6  
35  
+24V2  
GND2  
Y14  
10  
11  
12  
13  
36  
Output 6  
24V DC  
0V  
37  
Output 14  
24V DC  
0V  
+24V1  
GND1  
38  
+24V2  
GND2  
39  
PIN No.  
14  
ID  
FUNCTION  
0V  
PIN No.  
40  
ID  
FUNCTION  
0V  
GND1  
Y1  
GND2  
Y9  
15  
Output 1  
24V DC  
0V  
41  
Output 9  
24V DC  
0V  
16  
+24V1  
GND1  
Y3  
42  
+24V2  
GND2  
Y11  
17  
43  
18  
Output 3  
24V DC  
0V  
44  
Output 11  
24V DC  
0V  
19  
+24V1  
GND1  
Y5  
45  
+24V2  
GND2  
Y13  
20  
46  
21  
Output 5  
24V DC  
0V  
47  
Output 13  
24V DC  
0V  
22  
+24V1  
GND1  
Y7  
48  
+24V2  
GND2  
Y15  
23  
49  
24  
Output 7  
24V DC  
0V  
50  
Output 15  
24V DC  
0V  
25  
+24V1  
GND1  
51  
+24V2  
GND2  
26  
52  
R7F4HEIP-DC16A SPECIFICATIONS  
ES-8005-B Rev.0 Page 3/5  
https://www.m-system.co.jp/  
MODEL: R7F4HEIP-DC16A  
■POWER SUPPLY TERMINAL ASSIGNMENT  
Applicable connector: TFMC1,5 / 5–STF–3,5(Phoenix Contact)  
(included in the package)  
Applicable wire size: 0.2 − 1.5 mm2; stripped length 10 mm  
Recommended solderless terminal  
• AI0,25-10YE 0.25 mm2 (Phoenix Contact)  
• AI0,34-10TQ 0.34 mm2 (Phoenix Contact)  
• AI0,5-10WH 0.5 mm2 (Phoenix Contact)  
• AI0,75-10GY 0.75 mm2 (Phoenix Contact)  
• A1-10 1.0 mm2 (Phoenix Contact)  
• A1,5-10 1.5 mm2 (Phoenix Contact)  
1 2 3 4 5  
1. FE  
2. NC  
3. NC  
Functional Earth  
4. +24V Power Input (  
24V DC  
)
5. 0V  
Power Input ( )  
0V  
I/O DATA DESCRIPTIONS  
DISCRETE OUTPUT  
15  
0
Output 0  
Output 1  
Output 2  
Output 3  
Output 7  
Output 8  
Output 15  
0: OFF 1: ON  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm  
138 [5.43]  
123 [4.84]  
115 [4.53]  
72 [2.83]  
55 [2.17]  
DIN rail  
(35mm wide)  
(4 [.16])  
2-4.3 dia. 4 deep.  
R7F4HEIP-DC16A SPECIFICATIONS  
ES-8005-B Rev.0 Page 4/5  
https://www.m-system.co.jp/  
MODEL: R7F4HEIP-DC16A  
MOUNTING REQUIREMENTS unit: mm [inch]  
125 [4.92]  
2-M4  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Note: In order to improve EMC performance, bond the FE terminal to ground.  
Caution: FE terminal is NOT a protective conductor terminal.  
Isolation  
3
4
2
+24V1  
GND1  
Y0  
*1  
OUTPUT Y0  
RJ-45 MODULAR JACK  
RJ-45 MODULAR JACK  
EtherNet/IP  
*1  
EtherNet/IP  
Isolation  
25  
26  
24  
+24V1  
GND1  
Y7  
4
5
2
3
1
24V DC  
0V  
OUTPUT Y7  
NC  
1
+24V1  
GND1  
EXC. SUPPLY (IN)  
OUTPUT Y8  
NC  
14  
Control  
Circuit  
FE  
29  
30  
28  
+24V2  
GND2  
Y8  
51  
52  
50  
+24V2  
GND2  
Y15  
OUTPUT Y15  
27  
+24V2  
GND2  
EXC. SUPPLY (IN)  
40  
*1. The network cable can be connected to either one  
Specifications are subject to change without notice.  
R7F4HEIP-DC16A SPECIFICATIONS  
ES-8005-B Rev.0 Page 5/5  
https://www.m-system.co.jp/  

相关型号:

R7F4HEIP-DC16A-4-R

Remote I/O R7F4HEIP Series EtherNet/IP I/O MODULE
MSYSTEM

R7F4HEIP-DC16A-4-R/Q

Remote I/O R7F4HEIP Series EtherNet/IP I/O MODULE
MSYSTEM

R7FA2A1AB2CBT

32-Bit MCU Renesas Advanced (RA) Family Renesas RA2 Series
RENESAS

R7FA2A1AB3CFJ

32-Bit MCU Renesas Advanced (RA) Family Renesas RA2 Series
RENESAS

R7FA2A1AB3CFM

32-Bit MCU Renesas Advanced (RA) Family Renesas RA2 Series
RENESAS

R7FA2A1AB3CNE

32-Bit MCU Renesas Advanced (RA) Family Renesas RA2 Series
RENESAS

R7FA2A1AB3CNF

32-Bit MCU Renesas Advanced (RA) Family Renesas RA2 Series
RENESAS

R7FA2L1A92DFL

Ultra low power 48 MHz Arm® Cortex-M23 core, up to 256-KB code flash memory
RENESAS

R7FA2L1A92DFM

Ultra low power 48 MHz Arm® Cortex-M23 core, up to 256-KB code flash memory
RENESAS

R7FA2L1A92DFN

Ultra low power 48 MHz Arm® Cortex-M23 core, up to 256-KB code flash memory
RENESAS

R7FA2L1A92DFP

Ultra low power 48 MHz Arm® Cortex-M23 core, up to 256-KB code flash memory
RENESAS

R7FA2L1A92DNE

Ultra low power 48 MHz Arm® Cortex-M23 core, up to 256-KB code flash memory
RENESAS