R3-NC2-L3/Q [MSYSTEM]
Remote I/O R3 Series CC-Link INTERFACE MODULE;型号: | R3-NC2-L3/Q |
厂家: | M-SYSTEM |
描述: | Remote I/O R3 Series CC-Link INTERFACE MODULE |
文件: | 总8页 (文件大小:189K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: R3-NC2
Remote I/O R3 Series
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
CC-Link INTERFACE MODULE
(CC-Link Ver.1.10; for 32-point analog signals)
/C02: Polyurethane coating
/C03: Rubber coating
27.5 [1.08]
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-8355)
130
[5.12]
PACKAGE INCLUDES...
• Terminating resistor (110 Ω, 0.5 W)
109
[4.29]
GENERAL SPECIFICATIONS
Connection
mm [inch]
CC-Link: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm , stripped length 7 mm)
2
MODEL: R3-NC2-[1][2]
Internal bus: Via the Installation Base
(model: R3-BSx)
ORDERING INFORMATION
• Code number: R3-NC2-[1][2]
Specify a code from below for each of [1] and [2].
(e.g. R3-NC2-R/CE/Q)
Internal power: Via the Installation Base (model: R3-BSx)
Power input, RUN contact output: M3 separable screw
terminal (torque 0.5 N·m)
Screw terminal: Nickel-plated steel
• Specify the specification for option code /Q
(e.g. /C01/SET)
Isolation: CC-Link to internal bus or internal power to power
supply to RUN contact output to FG
Input error data setting: Input value setting at input module
error with side DIP SW
[1] POWER INPUT
Dual communication setting: Set with the side DIP switch
Data allocation setting: Set with the side DIP switch
RUN indicator: Bi-color (green/red) LED; Green ON in normal
communication; Red ON when receiving data (Function
selected with DIP SW)
N: No power supply
AC Power
K3: 100 – 120 V AC
(Operational voltage range 85 - 132 V, 47 - 66 Hz) *
(CE not available)
ERR indicator: Bi-color (green/red) LED;
L3: 200 – 240 V AC
Green ON or blinking at communication error (OFF with
cable disconnection, blinking in setting error); Red ON at
transmitting data (Function selected with DIP SW)
■ RUN CONTACT OUTPUT
(Operational voltage range 170 - 264 V, 47 - 66 Hz) *
(CE not available)
DC Power
R: 24 V DC
RUN contact: Turns ON while the green RUN LED is ON (CC-
Link in normal communication).
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) *
* Not selectable for use with independent power modules or
network modules with the internal power input options.
Rated load: 250 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 0.5 A (resistive load)
(Less than 50 V AC to conform with EU Directive)
Maximum switching voltage: 250 V AC or 30 V DC
Maximum switching power: 250 VA or 150 W
Minimum load: 1 V DC @ 1 mA
[2] OPTIONS (multiple selections)
Standards & Approvals
blank: Without CE
/CE: CE marking
Mechanical life: 2 × 10 cycles (300 cycles/min.)
7
Other Options
When driving an inductive load, external contact protection
and noise quenching recommended.
blank: none
/Q: Option other than the above (specify the specification)
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 1/8
https://www.m-system.co.jp/
MODEL: R3-NC2
CC-Link COMMUNICATION
CC-Link: Conforms to Version 1.10
Station No. setting: Rotary switch; 1 – 64
Baud rate setting: Rotary switch
156kbps, 625kbps, 2.5Mbps, 5Mbps, 10Mbps
Station type: Remote device station
Required nodes: 8 (4 stations × 2)
(128 I/O points, 16 words) × 2
(This unit incorporates two ASICs, each requires 4 stations
(128 I/O points, 16 words), which are equivalent to two 4-
station remote devices.)
Transmission cable: Approved for CC-Link
INSTALLATION
Power consumption
•AC: Approx. 20 VA
•DC: Approx. 12 W
Current consumption (no power supply): 130 mA
Output current (power supply): 250 mA continuous at 20 V
DC; 400 mA for 10 minutes
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (CC-Link to
internal bus or internal power to power input to RUN contact
output to FG
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 2/8
https://www.m-system.co.jp/
MODEL: R3-NC2
EXTERNAL VIEW
■ FRONT VIEW
■ SIDE VIEW
Station No.
Rotary SW
SA1
x10
SA2
x1
RUN LED
ERR LED
B RATE
Baud Rate
Rotary SW
DIP SW
SW3
ON
SW2
SW1
FG
SLD
DG
DB
DA
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Configuration Jack
Euro Type
Connector Terminal
1
2
3
4
ON
ON
5
6
COMMUNICATION CABLE CONNECTIONS
MASTER UNIT
R3-NC2
I/O UNIT
TERMINATOR
blue
DA
DB
DA
DB
DA
DB
white
yellow
DG
SLD
FG
DG
SLD
FG
DG
SLD
FG
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 3/8
https://www.m-system.co.jp/
MODEL: R3-NC2
TRANSMISSION DATA DESCRIPTIONS
The DIP SW located at the side of the module specifies each I/O module's data allocation (occupied data area).
For example, when the data areas are assigned as shown below:
Module 1
Module 2
Module 3
Module 4
Module 5
Module 6
Module 7
Module 8
4
4
4
4
4
1
1
1
Then the I/O data are assigned as in the figures below:
■ INPUT DATA
■ OUTPUT DATA
The figure below shows the allocation of the data sent from
the master to the network module.
The figure below shows the allocation of the data sent from
the network module to the master.
15
0
15
0
RWr n+0
+2
RWw n+0
+2
Module 1
Module 2
Module 3
Module 4
Module 5
Module 1
Module 2
Module 3
Module 4
Module 5
+4
+4
+6
+6
+8
+8
+10
+12
+14
+16
+18
+20
+22
+10
+12
+14
+16
+18
+20
+22
Module 6
Module 7
Module 8
Module 6
Module 7
Module 8
Unused
Unused
+30
+30
Thirty-two (32) data areas are available to this unit. Total data areas occupied by I/O modules must be within this limitation.
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 4/8
https://www.m-system.co.jp/
MODEL: R3-NC2
15
F
0
0
15
F
0
0
E
D
C
B
A
9
8
7
6
5
4
3
2
1
E
D
C
B
A
9
8
7
6
5
4
3
2
1
RX(n+0)
RX(n+1)
RX(n+2)
Module Status
RX(n+8)
Error Status (Burnout Bit)
Data Error Status
Unused
Unused
RX(n+7)
Reserved Bit
RX(n+15)
Reserved Bit
• Module Status
RX(n+0)0 through RX(n+0)F indicate whether individual I/O modules are mounted or not. The bit corresponding to the mounted
slot turns to “1,” and the unmounted slot to “0.”
• Error Status
RX(n+1)0 through RX(n+1)F indicate error status for each module as described below. The bit corresponding to such module
turns to “1.”
R3-TSx, R3-RSx, R3-US4: Input burnout
R3-DA16A:
R3-YSx:
R3-PC16A:
Power input in error or disconnected
Output current error (e.g. load unconnected)
External power supply in error or disconnected
• Data Error Status
RX(n+2)0 through RX(n+2)F indicate overrange (R3-US4: out of -10% to +110%; the other types: out of -15% to +115%) status
for each module. The bit corresponding to such module turns to “1.”
• RX(n+3) through RX(n+6) are unused.
RX(n+8) through RX(n+14) are unused.
• RX(n+7)0 through RX(n+7)7 are reserved for future use. RX(n+7)B is assigned to Ready signal forASIC 0, which is turned to
“1” when the network module is in normal conditions. RX(n+7)8 through RX(n+7)A, RX(n+7)C through RX(n+7)F are not
used.
RX(n+15)0 through RX(n+15)7 are reserved for future use. RX(n+15)B is assigned to Ready signal for ASIC 1, which is
turned to “1” when the network module is in normal conditions. RX(n+15)8 through RX(n+15)A, RX(n+15)C through RX(n+15)F
are not used.
RX(n+0) 0, RX(n+1) 0, RX(n+2) 0 Module 1
RX(n+0) 1, RX(n+1) 1, RX(n+2) 1 Module 2
RX(n+0) 2, RX(n+1) 2, RX(n+2) 2 Module 3
:
:
RX(n+0) F, RX(n+1) F, RX(n+2) F Module 16
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 5/8
https://www.m-system.co.jp/
MODEL: R3-NC2
MODULE STATUS, ERROR STATUS, DATA ERROR STATUS
Shows each module's availability and error status.
15
0
Module 1
Module 2
Module 3
:
Module 16
I/O DATA DESCRIPTIONS
The data allocations for typical I/O modules are shown below.
Refer to the manual for each module for detailed data allocations.
■ ANALOG DATA (16-bit data, models: R3-SV4, YV4, DS4, YS4, US4, etc.)
16-bit binary data.
Basically, 0 to 100% of the selected I/O range is converted into 0 to 10000 (binary).
-15 to 0 % is a negative range represented in 2’s complement.
In case of R3-US4, -10 to 0% is a negative range represented in 2's complement.
15
0
■ TEMPERATURE DATA (16-bit data, models: R3-RS4, TS4, US4, etc.)
16-bit binary data.
With °C temperature unit, raw data is multiplied by 10. For example, 25.5°C is converted into 255.
With °F temperature unit, the integer section of raw data is directly converted into the data.
For example, 135.4°F is converted into 135.
Minus temperature is converted into negative values, represented in 2’s complements.
15
0
■ ANALOG DATA (16-bit data, models: R3-CT4A, CT4B, etc.)
16-bit binary data.
Integer obtained by multiplying unit value (A) by 100.
In case of CLSE-R5, integer obtained by multiplying unit value (A) by 1000.
15
0
■ ACCUMULATED COUNT DATA (32-bit data, models: R3-PA2, PA4A, WT1, WT4, etc.)
32-bit binary data is used for accumulated counts and encoder positions.
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.
15
0
0
+0
+1
Lower 16 bits
Higher 16 bits
15
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 6/8
https://www.m-system.co.jp/
MODEL: R3-NC2
■ BCD DATA (32-bit data, models: R3-BA32A, BC32A, etc.)
32-bit binary data is used for BCD.
Lower 16 bits are allocated from the lowest address to higher ones, higher 16 bits in turn.
15
15
0
+0
+1
Lower 16 bits
Higher 16 bits
0
■ 16-POINT DISCRETE DATA (models: R3-DA16, DC16, etc.)
15
0
Input 1 (Output 1)
Input 2 (Output 2)
Input 3 (Output 3)
:
:
Input 16 (Output 16)
0 : OFF
1 : ON
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
27.5 [1.08]
109 [4.29]
POSITIONING
GUIDE
6–M3
SCREW
1
4
2
5
3
6
TERMINAL
COVER
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 7/8
https://www.m-system.co.jp/
MODEL: R3-NC2
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.
LED Rotary SW
FG
Isolation
SLD
To Other
CC-Link
Devices
Control
Circuit
Communication
Circuit
DG
DB
DA
INTERNAL BUS
DIP SW
RUN +
1
4
INTERNAL POWER
RUN CONTACT OUTPUT
RUN –
*
U (+) 2
5
*
POWER INPUT
V (–) 3
*
FG
JACK
*Not provided with ‘No Power Supply’ type module.
6
CONFIGURATION JACK
Specifications are subject to change without notice.
R3-NC2 SPECIFICATIONS
ES-8421 Rev.18 Page 8/8
https://www.m-system.co.jp/