R1M-A1_R [MSYSTEM]
PC Recorders R1M Series PC RECORDER;型号: | R1M-A1_R |
厂家: | M-SYSTEM |
描述: | PC Recorders R1M Series PC RECORDER PC |
文件: | 总6页 (文件大小:237K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: R1M-A1
PC Recorders R1M Series
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
PC RECORDER
(contact input, 32 points)
/C02: Polyurethane coating
/C03: Rubber coating
Functions & Features
• Industrial recorder on PC
• 32-point dry contact inputs
• Easy system expansion via Modbus RTU
• Recorded data exportable to spreadsheet applications
RELATED PRODUCTS
• Connector terminal block (model: CNT)
• Special cable (model: FCN32)
PACKAGE INCLUDES...
• PC Recorder Software CD
175 [6.89]
• 9-pin D-sub connector, straight type (1 m or 3.3 ft)
40
[1.57]
115
[4.53]
GENERAL SPECIFICATIONS
Connection
mm [inch]
Power input, transmission: Euro type connector terminal
(Applicable wire size: 0.2 – 2.5 mm
2
(AWG24 – 12), stripped
length 7 mm)
MODEL: R1M-A1[1]-[2][3]
RS-232-C: 9-pin D-sub connector (male)
(Lock screw No. 4-40 UNC)
Input: M3 screw terminals (torque: 0.6N·m)
or FCN type connector (Fujitsu FCN-365P040-AU)
Screw terminal: Nickel-plated steel
ORDERING INFORMATION
• Code number: R1M-A1[1]-[2][3]
Specify a code from below for each of [1] through [3].
(e.g. R1M-A1T-M2/MSR/Q)
Housing material: Flame-resistant resin (gray)
Isolation: Input to RS-232-C or RS-485 to power
Count memory at power loss: Count value is not saved
when the power supply is lost.
• Specify the specification for option code /Q
(e.g. /C01)
Node address setting: Rotary switch; 1 – F (15 nodes)
RUN indicator LED: Green light blinks in normal conditions.
[1] FIELD TERMINAL TYPE
T: M3 screw terminals
C1: FCN type connector (No CE conformance)
COMMUNICATION
Baud rate: 38.4 kbps
[2] POWER INPUT
AC Power
Communication: Half-duplex, asynchronous, no procedure
Protocol: Modbus RTU
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
■ RS-232-C
47 – 66 Hz)
Standard: Conforms to RS-232-C, EIA
Transmission distance: 10 meters max.
■ RS-485
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
Standard: Conforms to TIA/EIA-485-A
Transmission distance: 500 meters max.
Transmission media: Shielded twisted-pair cable (CPEV-S
0.9 dia.)
[3] OPTIONS (multiple selections)
PC Recorder Software Package (must be specified)
/MSR: With
Other Options
blank: none
/Q: Option other than the above (specify the specification)
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 1/6
https://www.m-system.co.jp/
MODEL: R1M-A1
INPUT SPECIFICATIONS
Input: Dry contact, 32 points
Commons: All negatives
Sensing: Approx. 5 V DC (pull-up resistance 22 kΩ)
≤ 1.5 V at ON
≥ 4 V at OFF
Sampling rate: 50 msec.
• Totalizing Counter Function
Number of input channels: 16
(ch.1 thr. 16 available both with instantaneous status and
totalized value)
Max. input frequency: 100 Hz
Minimum pulse width: 5 ms
Counter reset input: Pulse rising (ch.32 assigned)
Max. counter value: 999 999 999 (reset to zero at overflow)
INSTALLATION
Power consumption
•AC: Approx. 10 VA
•DC: Approx. 7 W
Operating temperature: -5 to +60°C (23 to 140°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 400 g (0.88 lb)
PERFORMANCE
Multi-transmission time: 5 msec.
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (input to RS-232-
C or RS-485 to power to FG)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
Input or RS-232-C/RS-485 to power: Reinforced insulation
(300 V)
Input to RS-232-C/RS-485: Basic insulation (300 V)
RoHS Directive
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 2/6
https://www.m-system.co.jp/
MODEL: R1M-A1
PC RECORDER SOFTWARE
PC Recorder Software Package (model: MSRPAC-2010) is included with purchases of this model.
Refer to the MSRPAC-2010 data sheet for the contents of the package and the requirements for the PC to be prepared by the
user.
EXTERNAL VIEW
RS-232-C
9-pin Connector
RUN Indicator
LED
Power Terminals
RS-485
Connector
Node Address
Setting Rotary SW
Configurator
Jack
■ RS-232-C INTERFACE
1
5
6
9
ABBR.
PIN NO. EXPLANATION OF FUNCTION
BA (SD)
BB (RD)
AB (SG)
2
3
5
Transmitted Data
Received Data
Signal Common
CB (CS)
CA (RS)
7
8
Clear to Send
Request to Send
1
4
6
9
Not Used.
DO NOT connect. Connecting may
cause malfunctions.
MODBUS WIRING CONNECTION
R1M
RS-485
RS-485
R1M
T1
R1M
T1
T1
RS-232-C
T2
T2
T2
1
1
*
*
T3
T4
T3
T3
T4
T4
2
*
FG
*1. Internal terminating resistor is used when the device is at the end of a transmission line.
*2. Install shielded cables to all sections and ground them at single point.
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 3/6
https://www.m-system.co.jp/
MODEL: R1M-A1
CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FG terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.
■ FCN TYPE CONNECTOR
■ M3 SCREW TERMINALS
Input Circuit
Input Circuit
Output
Circuit
1
ch.1
ch.2
A1
ch.1
ch.2
RS-232-C
2
A2
A3
3
ch.3
ch.3
4
ch.4
A4
ch.4
5
ch.5
A5
ch.5
6
ch.6
A6
ch.6
Shielded Twisted-pair Cable
7
ch.7
A7
ch.7
+
T1
T2
T3
T4
To Other
PC Recorders
–
8
ch.8
A8
ch.8
9
COM (–)
ch.9
A9
ch.9
CN1
Jumper*
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
A10
A11
A12
A13
A14
A15
A16
ch.10
ch.11
ch.12
ch.13
ch.14
ch.15
ch.16
Term.
Resist.
ch.10
ch.11
Power
Circuit
T5
T6
T7
U (+)
POWER
V (–)
ch.12
ch.13
FG
ch.14
ch.15
ch.16
B1
:
B16
COM (–)
COM (–)
ch.17
ch.18
A1
A2
ch.17
ch.19
ch.18
ch.20
A3
ch.19
ch.21
A4
ch.20
ch.22
A5
ch.21
ch.23
A6
ch.22
ch.24
A7
ch.23
COM (–)
ch.25
A8
ch.24
A9
ch.25
ch.26
CN2
A10
A11
A12
A13
A14
A15
A16
ch.26
ch.27
ch.27
ch.28
ch.28
ch.29
ch.29
ch.30
ch.30
ch.31
ch.31
Count Reset Input ch.32
COM (–)
Count Reset Input ch.32
B1
:
COM (–)
B16
* When the device is located at the end of a transmission line via twisted-pair cable,
(when there is no cross-wiring), close across the terminal T2 – T3 with the attached
jumper pin (or with a leadwire).
When the device is not at the end, remove the jumper pin.
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 4/6
https://www.m-system.co.jp/
MODEL: R1M-A1
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
■ M3 SCREW TERMINALS
175 [6.89]
165 [6.50]
15.5 [.61]
3–5 [.20] dia.
MTG HOLES
T5 T6 T7
T1 T2 T3 T4
DIN RAIL
35 mm wide
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35
3 [.12]
40 [1.57]
163 [6.42]
(6 [.24])
FOR WALL MOUNT.
6.2 [.24]
36–M3 INPUT TERMINALS
■ FCN TYPE CONNECTOR
175 [6.89]
165 [6.50]
40 [1.57]
15.5 [.61]
3–5 [.20] dia.
MTG HOLES
T5 T6 T7
T1 T2 T3 T4
Connector Pin
Assignment
A1
B1
DIN RAIL
35 mm wide
CN1
CN2
See Caution below
3 [.12]
163 [6.42]
40 [1.57]
(6 [.24])
FCN TYPE INPUT CONNECTOR
FOR WALL MOUNT.
Caution: DO NOT APPLY EXCESSIVE FORCE onto
the connector. The connector may be destroyed.
A16 B16
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 5/6
https://www.m-system.co.jp/
MODEL: R1M-A1
SYSTEM CONFIGURATION EXAMPLES
RS-232-C
RS-232-C/RS-485
Converter
(model: R2K-1)
RS-485
TC/DC Inputs
(model: R1M-GH)
Contact Inputs Contact Outputs
(model: R1M-A1) (model: R1M-D1)
When the cable distance between the PC and the R1Ms is long,
insert an RS-232-C/RS-485 Converter for isolation.
Specifications are subject to change without notice.
R1M-A1 SPECIFICATIONS
ES-5660 Rev.19 Page 6/6
https://www.m-system.co.jp/
相关型号: