R10M-CT4E-R [MSYSTEM]
Plug-in Remote I/O R10 Series MODBUS I/O MODULE;型号: | R10M-CT4E-R |
厂家: | M-SYSTEM |
描述: | Plug-in Remote I/O R10 Series MODBUS I/O MODULE |
文件: | 总7页 (文件大小:365K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: R10M-CT4E
Plug-in Remote I/O R10 Series
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
MODBUS I/O MODULE
(4 points, RMS sensing, clamp-on current sensor input)
/C02: Polyurethane coating
/C03: Rubber coating
Functions & Features
• Plug-in construction
• Modbus-RTU protocol communication
• Easy-to-install clamp-on type current sensor without
needing a current transformer
RELATED PRODUCTS
• Installation base (model: R10-BS)
• PC configurator software (model: R10CFG)
The configurator software is downloadable at M-System’s
web site.
• Wide input range from 5 A up to 600 A
• High-density mounting
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
36
[1.42]
• Clamp-on current sensor (model: CLSE)
The clamp-on current sensors, not included in this product
package, must be ordered separately. Required number
depends upon the system configuration.
99
[3.90]
125
[4.92]
PACKAGE INCLUDES...
• Terminating resistor 110Ω (0.25W)
mm [inch]
Note: The !gure shows the combination
of the unit and the base.
GENERAL SPECIFICATIONS
Construction: Plug-in
MODEL: R10M-CT4E-R[1]
Connection
• Connected to base with connector
• Base
ORDERING INFORMATION
• Code number: R10M-CT4E-R[1]
Specify a code from below for [1].
(e.g. R10M-CT4E-R/Q)
M2.6 screw terminals (torque: 0.5 N·m)
Applicable solderless terminal size (M3)
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
Isolation: Input to Modbus to power input to FE1
Input waveform
• Specify the specification for option code /Q
(e.g. /C01)
RMS sensing: Up to 15 % of 3rd harmonic content
Status indicators: Power, Run, Error
Configuration: Select sensors for 4 points (CT1, CT2, CT3,
CT4) each with PC Configurator Software (model: R10CFG)
■Recommended solderless terminal size - M3 (unit: mm)
I/O TYPE
CT4E: Clamp-on current sensor CLSE use 4 points
POWER INPUT
DC Power
3max
4min
3.2 dia.
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[1] OPTIONS
(mm)
blank: none
/Q: With options (specify the specification)
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 1/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
configurator software)
MODBUS COMMUNICATION
RS-485
Temp. coefficient: ±0.03 %/°C (±0.02 %/°F)
Response time: ≤ 2 sec. (0 – 90 %)
Standard: Conforms to TIA/EIA-485-A
Protocol: Modbus-RTU
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (input to Modbus
to power input to FE1)
Transmission distance: 500 meters max.
Transmission media: Shielded twisted-pair cable
(CPEV-S 0.9 dia.)
Status indicator LED: RD, SD
STANDARDS & APPROVALS
EU conformity:
Transmission setting: PC configurator software
EMC Directive
EMI EN 61000-6-4
INPUT SPECIFICATIONS
Input setting: PC configurator software
Clamp-on current sensor (CT1, CT2)
Input (sensor & range)
EMS EN 61000-6-2
RoHS Directive
CLSE-R5: 0 – 5 A
CLSE-05: 0 – 50 A
CLSE-10: 0 – 100 A
CLSE-20: 0 – 200 A
CLSE-40: 0 – 400 A
CLSE-60: 0 – 600 A
Frequency: 50 / 60 Hz (45 - 65 Hz)
Operational range: 0 – 105 % of rating
Overload capacity
CLSE-R5: 10 A continuous
CLSE-05: 60 A continuous
CLSE-10: 120 A continuous
CLSE-20: 240 A continuous
CLSE-40: 480 A continuous
CLSE-60: 720 A continuous
Be sure that the input voltage is of 480 V or less.
INSTALLATION
Current consumption: ≤90 mA
Operating temperature: -10 to +55°C (14 to 131°F)
Storage temperature: -10 to +55°C (14 to +131°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R10BS)
Weight: 120 g (0.26 lb) except base
PERFORMANCE
Conversion accuracy: ±1 % except the sensor accuracy
Conversion rate: 14 ms
Data range
CLSE-R5: Integer that engineering unit value (A) multiplied
by 1000
CLSE-05, CLSE-10, CLSE-20: Integer that engineering unit
value (A) multiplied by 100
CLSE-40, CLSE-60: Integer that engineering unit value (A)
multiplied by 10
(Scaling of converted data is configurable with the
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 2/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
CONFIGURATOR SOFTWARE SETTING
The following parameters can be set with using PC Configurator Software (model: R10CFG)
Refer to the users manual for the R30CFG for detailed operation of the software program.
INPUT SETTING
■
Each channel can be set independently.
ITEM
Clamp-on Current Sensor
Zero Input
SETTING RANGE
CLSE-R5 / CLSE-05 / CLSE-10 / CLSE-20 / CLSE-40 / CLSE-60
CLSE-R5: 0.000 - 5.000 (≤ full input)
CLSE-05: 0.00 - 50.00 (≤ full input)
CLSE-10: 0.00 - 100.00 (≤ full input)
CLSE-20: 0.00 - 200.00 (≤ full input)
CLSE-40: 0.00 - 400.00 (≤ full input)
CLSE-60: 0.00 - 600.00 (≤ full input)
CLSE-R5: 0.000 - 5.000 (≥ zero input)
CLSE-05: 0.00 - 50.00 (≥ zero input)
CLSE-10: 0.00 - 100.00 (≥ zero input)
CLSE-20: 0.00 - 200.00 (≥ zero input)
CLSE-40: 0.00 - 400.00 (≥ zero input)
CLSE-60: 0.00 - 600.00 (≥ zero input)
-320.00 - 320.00
DEFAULT SETTING
CLSE-R5
0.000
Full Input
0.000
Zero Fine Adjust
Gain Zero Adjust
Zero Scaling
Full Scaling
0.00 (%)
1.0000
0
-3.2000 - 3.2000
-32000 - 32000
-32000 - 32000
10000
1.0 (%)
Cutout
0.0 - 5.0 (%)
■ MODBUS SETTING
ITEM
Data Mode
SETTING RANGE
Modbus-RTU / Modbus-ASCII
1 - 247
DEFAULT SETTING
Modbus-RTU
1
Address
Baud Rate
38400 / 19200 / 9600 / 4800 bps
None / Odd / Even
38400 bps
None
Parity
Communication timeout duration
0.1 - 3200.0 (sec.)
3.0 sec.
Depending on data mode and parity bit setting, data bit and stop bit are as following.
DATA MODE
Modbus-RTU
PARITY BIT
None
DATA BIT
STOP BIT
8
8
7
7
2
1
2
1
Odd or Even
None
Modbus-ASCII
Odd or Even
EXTERNAL VIEW
Specications (side)
Status Indicator LED
Congurator Jack
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 3/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
MODBUS WIRING CONNECTION
■ WIRING COMMUNICATION WITH HOST PC
MODBUS
I/O
MODBUS
I/O
HOST PC
MODULE
MODULE
TERMINATOR
TERMINATOR
DA
DA
DB
DA
DB
DG
DB
DG
SLD
FE
DG
SLD
FE
Note: The terminator must be connected across “DA” and “DB” at both ends of communication line.
TERMINAL ASSIGNMENTS
■ BASE
PIN NO.
ID
K1
K2
K3
K4
NC
L1
L2
L3
L4
NC
FUNCTION
Input 1-K
PIN NO.
11
ID
FE
DB
DA
NC
FE1
FUNCTION
Modbus grounding
DB
1
K1
2
K2
3
K3
4
K4
5
1
2
NC
10
NC
Input 2-K
Input 3-K
Input 4-K
Unused
12
6
L1
7
L2
8
L3
9
L4
3
13
DA
4
14
Unused
5
15
Power grounding
6
Input 1-L
Input 2-L
Input 3-L
Input 4-L
Unused
16
SLD Shield
7
17
DG
NC
DG
8
18
Unused
9
19
24V Power supply 24V DC
0V Power supply 0V DC
10
20
11
FE
16
SLD DG NC 24V 0V
12
DB DA NC FE1
17 18 19 20
13
14
15
* Base does not come with the unit. Please order separately.
MODBUS FUNCTION CODES & SUPPORTED CODES
Modbus function codes are shown below
■ DATA AND CONTROL FUNCTIONS
CODE
02
NAME
Read Input Status
Read Input Registers
Status of digital inputs to the slave (read only)
04
Collected data from the fi eld by the slave (read only)
■ EXCEPTION CODES
CODE
NAME
01
02
03
Illegal Function
Illegal Data Address
Illegal Data Value
Function code is not allowable for the slave
Address is not available within the slave
Data is not valid for the function
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 4/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
MODBUS I/O ASSIGNMENT
ADDRESS
DATA TYPE
DATA
Input (0X)
1
2
3
4
1
2
3
4
Analog input 1 error (input range error)
Analog input 2 error (input range error)
Analog input 3 error (input range error)
Analog input 4 error (input range error)
Analog Input (analog input 1)
Input Register (3X)
I
I
I
I
Analog Input (analog input 2)
Analog Input (analog input 3)
Analog Input (analog input 4)
Note: DO NOT access addresses other than the ones mentioned above. Such access may cause problems such as malfunction.
■ DATA TYPE
I: Integer, 0
- 65535
■ STATUS
1 bit: indicates input status.
input range error ( (Input range is out of the range)
0: Normal
1: Error
DATA CONVERSION
■ ENGINEERING UNIT CONVERSION
CLSE-R5 is multipled by 1000, CLSE-10 and CLSE-20 is multipled 100, CLSE-40 and CLSE-60 is multipled by 10, expressed in 16 bits
(0 - 65535).
■ SCALED ANALOG DATA (16-bit) CONVERSION
15
0
The data is 0 to 10000 for scaling 0 to 100% setting.
If the input range is 0 to +105% (0 to +10500) and that is out of range, the data is fixed to 0 or 10500.
■ DATA ERROR STATUS
Data error status is indicated by 1 bit.
0: OFF
1: ON
EXTERNAL DIMENSIONS unit: mm [inch]
36 [1.42]
80 [3.15]
45 [1.77]
[4 [.16]]
DIN rail
(35mm wide)
• When mounting, no extra space is needed between units.
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 5/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
MOUNTING REQUIREMENTS unit: mm [inch]
2-M4
* Mounting requirements for base.
TERMINAL ASSIGNMENTS
■ BASE
1
6
2
7
3
8
4
9
5
10
11 12 13 14 15
16 17 18 19 20
* Base does not come with the unit. Please order separately.
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 6/7
https://www.m-system.co.jp/
MODEL: R10M-CT4E
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Status Indicator LED
Communication
Circuit
Jack
1
12 DB
Configurator Jack
Isolation
K1
13
DA
CT INPUT 1
Control
Circuit
K2
6
17 DG
11 FE
16 SLD
To other Modbus devices
K3
CT INPUT 2
K4
2
7
Input
Circuit
3
L1
CT INPUT 3
L2
19 24V DC
20 0V
POWER
8
4
L3
CT INPUT 4
L4
15 FE1
14 NC
9
5
NC
18 NC
NC 10
Base
■ INPUT CONNECTION
SOURCE
k
Kn
Ln
CLAMP-ON SENSOR
l
LOAD
Specifications are subject to change without notice.
R10M-CT4E SPECIFICATIONS
ES-6247 Rev.0 Page 7/7
https://www.m-system.co.jp/