MP1823-0-0FY [MSYSTEM]
POTENTIOMETER INPUT LIMIT ALARM;型号: | MP1823-0-0FY |
厂家: | M-SYSTEM |
描述: | POTENTIOMETER INPUT LIMIT ALARM 输入元件 |
文件: | 总4页 (文件大小:87K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Limit Alarms M-PAC
MODEL
POTENTIOMETER INPUT LIMIT ALARM
MP1800-1823
MODEL & SUFFIX CODE SELECTION
50
(1.97)
MP18❑❑–0–❑/❑
MODEL
INPUT TYPE
80
(3.15)
SET
1
SPAN
ZERO
8 : Potentiometer
M•PAC
LIMIT ALARM
SET
1
DEADBAND
RELAY CONTACT OUTPUT
0 : Single (Hi) trip, non-latching
1 : Single (Hi) trip, latching
2 : Dual (Hi/Lo) trip, non-latching
SET
2
DEADBAND
132
(5.20)
SET
2
mm (inch)
SETPOINT CONTROL
Functions & Features
0 : Front-accessed three-turn screwdriver adjust.
2 : Remote dial connections (total resistance 1k – 100kΩ)
3 : DC programmable (0 – 1V)
INPUT RESISTANCE
0 : Total resistance 100Ω – 100kΩ
POWER INPUT
• Accepting potentiometer resistance and provid-
ing relay contact closure(s) at a preset input level •
Single, latching or dual setpoint • Failsafe opera-
tion available • Deadband adjustable from 1 to 100%
• Indicator LED provided
Typical Applications
F : 120V AC
J : 240V AC
• Annunciator • Various alarm applications
R : 24V DC
S : 12V DC
OPTIONS
GENERAL SPECIFICATIONS
Construction: plug-in
Connection: M3.5 screw terminals on base socket
Housing material: flame-resistant resin (black)
Isolation: input to output to power
(non-isolated between I/O with Option V)
Zero/span adjustments: multi-turn screwdriver
(front); 0 – 50% of total resistance for
zero; 50 – 100% for span
Setpoint adjustments: front accessed three-turn
screwdriver, remote dial potentiometer
or DC input
H : Latching operation for dual trip (182X only);
Reset at power off (5 seconds min.)
R : Reversed relay sense
T : Transmitter output (0 – 1V DC)
V : Relay drive voltage output
X : Lo-trip sense for single trip; Lo/Lo for dual trip
Y : Hi/Hi-trip sense for dual trip (182X only)
ORDERING INFORMATION
Specify code number. (e.g. MP1800-0-F/T/V)
Deadband adjustments: front accessed single-turn
screwdriver; 1 – 100%
Front LEDs: red lights turn on at a tripped condition
Power ON timer: relays de-energized for approx. 2
seconds after power is turned on.
P. 1 / 4
ES-9807 Rev.6
MP1800-1823
INPUT & OUTPUT
INSTALLATION
■INPUT: potentiometer; 100Ω – 100kΩ
Power input
AC:
DC:
rating ±10%, 50/60 ±2 Hz, approx. 2VA
rating ±10% (ripple 10% p-p max.)
80mA at 24V, 160mA at 12V
■REMOTE SETPOINT INPUT
MP18X2: potentiometer; any value of 1k – 100kΩ;
excitation 4V
Operating temperature: -5 to +60°C (23 to 140°F)
Storage temperature: -20 to +85°C (-5 to +185°F)
Operating humidity: 30 to 90% RH (non-condensing)
Mounting: surface (DIN rail available for 11-pin base)
Dimensions
MP18X3: 0 – 1V DC
■RELAY CONTACT OUTPUT
•Single/Latching: isolated DPDT relay; de-energized
at trip
11-pin base: W50×H80×D132 mm
(1.97"×3.15"×5.20")
•Dual:
isolated SPDT relay; energized at trip
See General Spec. Sheet Figure A.
20-pin base: W80×H101×D136 mm
(3.15"×3.98"×5.35")
Rating:
120V AC @3A (cosø=1)
30V DC @3A (resistive load)
Relay life
See General Spec. Sheet Figure B.
400 g (0.88 lbs)
Electrical: 105 cycles
Mechanical: 107 cycles
For maximum relay life with inductive
Weight:
PERFORMANCE in percentage of span
Repeatability: ±0.2%
loads, external protection is recommended.
Temp. coefficient: ±0.05%/°C (±0.027%/°F)
Response time: 100 milliseconds, typical
Common mode rejection
■VOLTAGE OUTPUT (Option V): 24V DC average;
Drives 1.2kΩ or greater coil impedance
60 Hz: greater than 120 dB
■TRANSMITTER OUTPUT (Option T): 0 – 1V DC;
DC:
greater than 140 dB
1mA max. (setpoint and process input)
Line voltage effect: ±0.1% over voltage range
Insulation resistance: ≥100MΩ with 500V DC
Dielectric strength: 1000V AC @1 minute
(input to output to power)
2000V AC @1 minute (output to ground)
Specifications subject to change without notice.
P. 2 / 4
ES-9807 Rev.6
BLOCK DIAGRAM
■SINGLE / LATCHING OUTPUT
•11-pin Base
•20-pin Base
Option V
Option V
Z
S
SP.SET DB
Z
S
SP.SET DB
6
7
6
7
13
14
15
17
18
19
13
14
15
17
18
19
N.O.
COM.
N.C.
N.O.
COM.
N.C.
MAX.
MIN.
MAX.
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
+
–
4
5
1
2
3
AMP
9
AMP
INPUT
INPUT
8
8
11
1
INPUT
+
INPUT
+
MIN.
9
9
HOT /
N.O.
COM.
N.C.
HOT /
N.O.
COM.
N.C.
POWER
10
11
10
11
2
POWER
INPUT
–
–
3
NEU /
NEU /
20
16
4
INPUT
LATCH RESET
LATCH RESET
MP181X
+
8
MP18X2
MP18X3
SP
MP18X0
SP XMTR
–
5
6
7
5
6
7
5
6
7
10
12
SP POT CCW
SP POT W
XMTR COMMON
+
+
SP
PROC XMTR
SP POT CW
Option T
■DUAL OUTPUT
•11-pin Base
•20-pin Base
Option V
Option V
Z
S
SP.SET DB
Z
S
SP.SET DB
HI
LO
6
7
6
7
13
14
15
17
18
19
13
14
15
17
18
19
N.O.
COM.
N.C.
N.O.
MAX.
MIN.
MAX.
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
–
+
4
5
1
2
3
AMP
9
AMP
INPUT
INPUT
COM.
N.C.
8
8
11
1
INPUT
+
INPUT
+
MIN.
SP.SET DB
SP.SET DB
9
9
HOT /
N.O.
COM.
N.C.
HOT /
N.O.
COM.
N.C.
COM-
PAR
COM-
PAR
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
RELAY
DRIVE
+
–
–
+
POWER
10
11
10
11
2
POWER
INPUT
–
–
3
NEU /
NEU /
LO
HI
20
4
INPUT
4
4
5
6
7
8
LO SP POT CW
LO SP POT W
SP POTS CCW
HI SP POT W
MP1823
LO SP
MP1820
Option T
+
+
5
5
6
7
8
10
12
16
6
PROC XMTR
LO SP XMTR
HI SP XMTR
SP
COMMON
+
6
+
+
7
HI SP
8
HI SP POT CW
MP1822
XMTR COMMON
P. 3 / 4
ES-9807 Rev.6
MP1800-1823
TERMINAL ASSIGNMENT
■SINGLE OUTPUT
KEYS
PIN
MP1800
MP1800
MP1802
MP1802
MP1803
MP1803
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
w/Option T
w/Option T
w/Option T
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
POWER (Hot/+)
INPUT Max. CW
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
No Connection
INPUT Min. CCW No Connection
POWER (Hot/+)
No Connection
INPUT W
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
No Connection
INPUT W
No Connection
SP Pot CCW
SP Pot W
SP Pot CW
SP Xmtr +
No Connection
SP –
SP +
No Connection
No Connection
INPUT W
No Connection
SP –
SP +
No Connection
SP Xmtr +
INPUT W
Xmtr Common
N.O.
No Connection
No Connection
SP Xmtr +
INPUT W
Xmtr Common
COM *
N.C. *
N.O.
COM
N.C.
*Pins used for Option V
20-pin = 14(+) - 15(–)
11-pin = 7(+) - 8(–)
INPUT W
Xmtr Common
No Connection
No Connection
INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW
No Connection
N.O.
COM *
N.C. *
No Connection
N.O.
COM
N.C.
INPUT Max. CW
Proc Xmtr +
N.O.
COM *
N.C. *
No Connection
N.O.
COM
N.C.
INPUT Max. CW
No Connection
N.O.
COM *
N.C. *
No Connection
N.O.
COM
N.C.
INPUT Max. CW
Proc Xmtr +
N.O.
COM *
N.C. *
No Connection
N.O.
COM
N.C.
INPUT Max. CW
N.O.
COM *
N.C. *
No Connection
N.O.
COM
N.C.
INPUT Max. CW
■LATCHING OUTPUT
KEYS
PIN
MP1810
MP1810
MP1812
MP1812
MP1813
MP1813
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
w/Option T
w/Option T
w/Option T
1
2
3
4
5
6
7
8
9
POWER (Hot/+)
No Connection
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
POWER (Hot/+)
No Connection
Latch Reset
Latch Reset
No Connection
No Connection
No Connection
SP Xmtr +
Latch Reset
SP Pot CCW
SP Pot W
SP Pot CW
No Connection
INPUT W
Latch Reset
SP Pot CCW
SP Pot W
SP Pot CW
SP Xmtr +
INPUT W
Latch Reset
SP –
SP +
No Connection
No Connection
INPUT W
No Connection
Latch Reset
SP –
SP +
No Connection
SP Xmtr +
INPUT W
Xmtr Common
No Connection
No Connection
No Connection
No Connection
INPUT W
*Pins used for Option V
20-pin = 14(+) - 15(–)
INPUT W
Xmtr Common
10
11
12
13
14
15
16
17
18
19
20
No Connection
No Connection
Xmtr Common
INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW
No Connection
N.O.
Proc Xmtr +
N.O.
No Connection
N.O.
Proc Xmtr +
N.O.
No Connection
N.O.
Proc Xmtr +
N.O.
COM *
COM *
COM *
COM *
COM *
COM *
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
N.C. *
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
Latch Reset
N.O.
COM
COM
COM
COM
COM
COM
N.C.
N.C.
N.C.
N.C.
N.C.
N.C.
INPUT Max. CW
INPUT Max. CW
INPUT Max. CW
INPUT Max. CW
INPUT Max. CW
INPUT Max. CW
■DUAL OUTPUT
KEYS
PIN
MP1820
MP1820
MP1822
MP1822
MP1823
MP1823
N.O. = Normally Open
COM = Common
N.C. = Normally Closed
Proc = Process
Xmtr = Transmitter
SP = Setpoint
W = Wiper
CW = Clockwise
CCW = Counterclockwise
w/Option T
w/Option T
w/Option T
1
2
3
4
5
6
POWER (Hot/+)
INPUT max. CW
POWER (Hot/+) POWER (Hot/+) POWER (Hot/+) POWER (Hot/+)
No Connection No Connection No Connection No Connection
POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–) POWER (Neu/–)
POWER (Hot/+)
No Connection
INPUT W
INPUT Min. CCW No Connection
N.O. Xmtr Common
No Connection
Lo SP Pot CW
Lo SP Pot W
SP Pots CCW
Lo SP Pot CW
Lo SP Pot W
SP Pots CCW/
Xmtr Common
Hi SP Pot W
Hi SP Pot CW
INPUT W
No Connection
Lo SP +
SP Common/
No Connection
Lo SP +
SP Common/
Xmtr Common
Hi SP +
No Connection
INPUT W
Proc Xmtr +
7
8
9
COM * Hi Set No Connection
Hi SP Pot W
Hi SP Pot CW
INPUT W
Hi SP +
No Connection
INPUT W
*Pins used for Option V
20-pin:
Hi Set = 19(+) - 18(–)
Lo Set = 15(+) - 14(–)
11-pin:
Hi Set = 7(+) - 8(–)
Lo Set = 10(+) - 11(–)
N.C. *
N.O.
No Connection
INPUT W
10
11
12
13
14
15
16
17
18
19
20
COM * Lo Set Proc Xmtr +
N.C. *
No Connection
Proc Xmtr +
No Connection
INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW INPUT Min. CCW
Lo SP Xmtr +
N.O.
No Connection
N.O.
Lo SP Xmtr +
N.O.
No Connection
N.O.
Lo SP Xmtr +
N.O.
COM * Lo Set COM * Lo Set COM * Lo Set COM * Lo Set COM * Lo Set
N.C. *
Hi SP Xmtr +
N.O.
COM * Hi Set COM * Hi Set COM * Hi Set COM * Hi Set COM * Hi Set
N.C. *
INPUT Max. CW
N.C. *
No Connection
N.O.
N.C. *
Hi SP Xmtr +
N.O.
N.C. *
No Connection
N.O.
N.C. *
Hi SP Xmtr +
N.O.
N.C. *
INPUT Max. CW
N.C. *
INPUT Max. CW
N.C. *
INPUT Max. CW
N.C. *
INPUT Max. CW
Specifications subject to change without notice.