M6NXAT-6-R [MSYSTEM]
Screw Terminal Ultra-Slim Signal Conditioners M6N Series;型号: | M6NXAT-6-R |
厂家: | M-SYSTEM |
描述: | Screw Terminal Ultra-Slim Signal Conditioners M6N Series |
文件: | 总5页 (文件大小:160K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: M6NXAT
Screw Terminal Ultra-Slim Signal Conditioners M6N Series
OUTPUT
Relay; SPDT or transfer contact
THERMOCOUPLE ALARM
(PC programmable)
POWER INPUT
Functions & Features
DC Power
• 7.5-mm wide ultra-slim design
• Low profile allows the M6N module mounted in a 120-mm
deep panel
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• PC programmable
[2] OPTIONS
blank: none
• Linearization and upscale and downscale burnout
protection
/Q: With options (specify the specification)
• High-density mounting
• Power and status indicator LEDs
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
7.5 (.30)
/C02: Polyurethane coating
102
(4.02)
RELATED PRODUCTS
• PC configurator software (model: M6CFG)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
102
(4.02)
mm (inch)
MODEL: M6NXAT–[1]–R[2]
GENERAL SPECIFICATIONS
Connection
Input and output: M3 screw terminal (torque 0.5 N·m)
Power input: Via the Installation Base (model: M6NBS)
or M3 screw terminal (torque 0.5 N·m)
Recommended solderless terminal: Max. 5.8 mm (0.23”)
wide; Ones with insulation sleeve do not fit.
ORDERING INFORMATION
• Code number: M6NXAT-[1]-R[2]
Specify a code from below for each [1] and [2].
(e.g. M6NXAT-2-R/Q)
• Temperature range (e.g. 0 – 1000°C)
• Specify the specification for option code /Q
(e.g. /C01)
Applicable wire size: 0.2 – 2.5 mm
2
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Burnout: Upscale standard; downscale or no burnout
optional by programming
[1] INPUT THERMOCOUPLE
1: (PR)
In case of upscale standard, the alarm operates as if the
input signal has exceeded over the range.
Linearization: Standard
2: K (CA)
3: E (CRC)
4: J (IC)
Cold Junction Compensation: CJC sensor incorporated
Power LED: Green light turns on when the power is supplied.
Status indicator LED: Orange LED; Blinking patterns indicate
different operating status of the transmitter.
Alarm monitor LED: Red LED turns on when the alarm is
tripped.
5: T (CC)
6: B (RH)
7: R
8: S
N: N
0: Specify (Please provide a emf table.)
(Configurator software is used to change the input type and
precise range.)
Programming: Downloaded from PC
Input type and range
Input fine adjustments
User’s Thermocouple table
M6NXAT SPECIFICATIONS
ES-7922 Rev.4 Page 1/5
http://www.m-system.co.jp/
MODEL: M6NXAT
Burnout (Upscale, downscale or no burnout)
Alarm setpoint (input %)
Alarm Trip Operation Terminal No. in parentheses
• Setting Example
Hi alarm (coil energized at alarm) or
Lo alarm (coil de-energized at alarm)
Trip action (High or Low)
Relay coil (energized or de-energized)
Power ON delay time (0 to 999 sec.)
Alarm ON delay time (0 to 999 sec.)
Hysteresis (deadband) (input %)
Alarm test, and others
(3–2)ON
Output
(3–4)ON
Input
(%)
0
50
100
Setpoint
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level
Trip operation in power failure: Terminals 3 – 4 turn ON.
Factory default setting
Alarm setpoint: 80 %
INSTALLATION
Power consumption: Approx. 0.5 W
Trip action: High
Relay coil at alarm: Energized
Power ON delay time: 5 sec.
Alarm ON delay time: 0 sec.
Hysteresis (deadband) : 1.0 %
Burnout: Upscale
Operating temperature: -20 to +55°C (-4 to +131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Installation Base (model: M6NBS) or DIN rail
Weight: 65 g (2.3 oz)
■Recommended solderless terminal (unit: mm (inch))
PERFORMANCE in percentage of span
Setpoint accuracy (trip point accuracy):
Accuracy in Table 1 + Cold junction compensation error
Cold junction compensation error:
5.5 max.
(.22)
4 min.
(.16)
3.2 (.13) dia.
±3°C at 25 ±10°C
±5.4°F at 77 ±18°F
Temp. coefficient: ±0.01 %/°C (±0.006 %/°F) of max. span
Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint)
Burnout response time: ≤ 1 sec.
INPUT SPECIFICATIONS
Input resistance: 1 MΩ min.
Burnout sensing: ≤ 0.1 μA
Temperature range: See Table 1.
If not specified, the input range is shown below.
1 PR: 0 – 1600°C
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
2 K: 0 – 1000°C
3 E: 0 – 500°C
4 J: 0 – 500°C
5 T: 0 – 300°C
6 B: 500 – 1600°C
7 R: 500 – 1600°C
8 S: 0 – 1600°C
N N: 0 – 1000°C
OUTPUT SPECIFICATIONS
■ Relay Output
Relay rating:
250 V AC @2 A (cos ø = 1)
30 V DC @2 A (resistive load)
Maximum switching voltage: 250 V AC or 125 V DC
Maximum switching power: 500 VA or 60 W
Minimum load: 5 V DC @100 mA
Mechanical life: 5 × 10 cycles (rate 180/min.)
6
M6NXAT SPECIFICATIONS
ES-7922 Rev.4 Page 2/5
http://www.m-system.co.jp/
MODEL: M6NXAT
CALCULATION EXAMPLES OF SETPOINT ACCURACY
[Example] K thermocouple, 0 – 1000°C
Absolute value accuracy (Table 1): 0.25°C
CJC error (3°C) added: 3.25°C
Setpoint accuracy = 3.25°C ÷ 1000°C × 100 = 0.33 %
Table 1.
C
THERMOCOUPLE
MIN.
MAXIMUM
RANGE
CONFORMANCE
RANGE
ACCURACY
SPAN
(PR)
K (CA)
E (CRC)
J (IC)
T (CC)
B (RH)
R
20
20
20
20
20
20
20
20
20
0 to 1760
0 to 1760
1.00
0.25
0.20
0.25
0.25
0.75
0.50
0.50
0.30
-270 to +1370 -150 to +1370
-270 to +1000 -170 to +1000
-210 to +1200 -180 to +1200
-270 to +400 -170 to +400
100 to 1820 400 to 1760
-50 to +1760 200 to 1760
S
-50 to +1760
0 to 1760
N
-270 to +1300 -130 to +1300
F
THERMOCOUPLE
MIN.
MAXIMUM
RANGE
CONFORMANCE
RANGE
ACCURACY
SPAN
(PR)
K (CA)
E (CRC)
J (IC)
T (CC)
B (RH)
R
36
36
36
36
36
36
36
36
36
32 to 3200
32 to 3200
1.80
0.45
0.36
0.45
0.45
1.35
0.90
0.90
0.54
-454 to +2498 -238 to +2498
-454 to +1832 -274 to +1832
-346 to +2192 -292 to +2192
-454 to +752 -274 to +752
212 to 3308 752 to 3200
-58 to +3200 392 to 3200
S
-58 to +3200
32 to 3200
N
-454 to +2372 -202 to +2372
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Measurement Category II (output)
Pollution Degree 2
Input or power to output: Reinforced insulation (300 V)
Input to power: Basic insulation (300 V)
RoHS Directive
EN 50581
M6NXAT SPECIFICATIONS
ES-7922 Rev.4 Page 3/5
http://www.m-system.co.jp/
MODEL: M6NXAT
EXTERNAL VIEW
(With the cover open)
Power LED
Alarm Monitor LED
Status Indicator LED
Configurator Jack
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCREWDRIVER
INSERTION ANGLE
: approx. 55°
*
WIRE INSERTION ANGLE
: approx. 35°
8–M3
SCREW TERMINAL
DIN RAIL HOOK
5
6
7
8
DIN RAIL
35mm wide
1
2
3
4
[1 (.04)]
SCREWDRIVER
INSERTION ANGLE
: approx. 40°
7.5 (.30)
102 (4.02)
*Screwdriver stem diameter: 6 mm (.24”) or less
• When mounting, no extra space is needed between units.
M6NXAT SPECIFICATIONS
ES-7922 Rev.4 Page 4/5
http://www.m-system.co.jp/
MODEL: M6NXAT
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
STATUS ALARM
CJC
LED
MONITOR LED
SENSOR
comp. leadwire
+
–
4
2
3
NC
T/C
Digital
Computation
+
5
6
Ry
Low Drift
Amplifier
OUTPUT
NO
-
COM
POWER LED
1
+
–
7
8
POWER
POWER
JACK
CONFIGURATOR
■ Relay Protection
• AC Powered
• DC Powered
Inductive
Load (Coil)
Inductive
Load (Coil)
LOAD
LOAD
U
Diode, Varistor or
CR Circuit
Varistor or CR Circuit
Specifications are subject to change without notice.
M6NXAT SPECIFICATIONS
ES-7922 Rev.4 Page 5/5
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明