M6DXU-S1R9-M2/Q
更新时间:2024-09-18 22:58:11
品牌:MSYSTEM
描述:Euro Terminal Ultra-Slim Signal Conditioners M6D Series
M6DXU-S1R9-M2/Q 概述
Euro Terminal Ultra-Slim Signal Conditioners M6D Series
M6DXU-S1R9-M2/Q 数据手册
通过下载M6DXU-S1R9-M2/Q数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: M6DXU
T1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F)
Euro Terminal Ultra-Slim Signal Conditioners M6D Series
T2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F)
T3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F)
T4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F)
T5: T (CC) (Usable range -270 to +400°C, -454 to +752°F)
T6: B (RH) (Usable range 100 to 1820°C, 212 to 3308°F)
T7: R (Usable range -50 to +1760°C, -58 to +3200°F)
T8: S (Usable range -50 to +1760°C, -58 to +3200°F)
TN: N (Usable range -270 to +1300°C, -454 to +2372°F)
T0: Specify (Please provide an emf table.)
RTD
UNIVERSAL TRANSMITTER
(PC programmable)
Functions & Features
• Universal input (mV, V, mA, T/C, RTD and potentiometer)
5.9-mm ultra-slim transmitter
• Low profile allows the M6D module mounted in a 120-mm
deep panel.
• PC programmable
• High-density mounting
(2- , 3- or 4-wire)
• Power indicator LED
R1: JPt 100 (JIS'89)
(Usable range: -200 to +500°C, -328 to +932°F)
R3: Pt 100 (JIS'89)
5.9 (.23)
(Usable range: -200 to +650°C, -328 to +1202°F)
R4: Pt 100 (JIS'97, IEC)
(Usable range: -200 to +850°C, -328 to +1562°F)
R5: Pt 50 Ω (JIS'81)
94
(3.70)
(Usable range: -200 to +649 °C, -328 to +1200°F)
R7: Pt 1000
(Usable range: -200 to +850°C, -328 to +1562°F)
R9: Cu 10 @25°C
102
(4.02)
mm (inch)
(Usable range: -50 to +250°C, -58 to +482°F)
R0: Specify (Please provide a resistance table.)
Potentiometer
M1: Total resistance 100 – 5000 Ω
(Configurator software is used to change input over the
described range of the selected suffix code.
For changing between suffix codes, set the Input Range
Selector on the side of unit before software adjustment.)
MODEL: M6DXU–[1][2]–[3][4]
ORDERING INFORMATION
• Code number: M6DXU-[1][2]-[3][4]
Specify a code from below for each [1] through [4].
(e.g. M6DXU-Z1Z1-M2/Q)
[2] OUTPUT
0: User-calibrated (Factory default: 4 – 20 mA DC)
Non-specified orders will be shipped as default factory
settings (M6DXU-00: 4 – 20 mA input/4 – 20 mA output).
• Input range (e.g. 4 – 20 mA DC)
If the unit is to be factory-calibrated to a specific
output type, please select from the following:
Current
• Output range (e.g. 4 – 20 mA DC)
• Specify the specification for option code /Q
(e.g. /C01)
Z1: Range 0 – 20 mA DC
Voltage
V2: Range -10 – +10 V DC
[1] INPUT
0: User-calibrated (Factory default: 4 – 20 mA DC)
V3: Range -5 – +5 V DC
(Configurator software is used to change output over the
described range of the selected suffix code.
For changing between suffix codes, set the Output Range
Selector on the side of unit before software adjustment.)
If the unit is to be factory-calibrated to a specific
input type, please select from the following:
Current
Z1: Range 0 – 50 mA DC (Input resistance 17 Ω)
Voltage
[3] POWER INPUT
AC Power
S1: Range -1000 – +1000 mV DC (Input resistance 1 MΩ min.)
S2: Range -10 – +10 V DC (Input resistance 1 MΩ min.)
Thermocouple
M2: 100 – 240 V AC (Operational voltage range 90 – 264 V,
47 – 66 Hz)
M6DXU SPECIFICATIONS
ES-7853 Rev.5 Page 1/6
http://www.m-system.co.jp/
MODEL: M6DXU
DC Power
PC configurator.
R: 24 V DC
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS
blank: none
INPUT SPECIFICATIONS
■ DC Current: Input resistor incoporated
(If not specified, the input range is 4 – 20 mA DC.)
Input range: 0 – 50 mA DC
Minimum span: 2 mA
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
Offset: Lower range can be any specific value within the
input range provided that the minimum span is maintained.
■ DC Voltage
/C02: Polyurethane coating
•Code S1 (narrow spans)
Input range: -1000 – +1000 mV DC
Minimum span: 100 mV
RELATED PRODUCTS
• PC configurator software (model: M6CFG)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
•Code S2 (wide spans)
Input range: -10 – +10 V DC
Minimum span: 1 V
Offset: Lower range can be any specific value within the
input range provided that the minimum span is maintained.
If not specified, the input range is shown below.
S1: 0 – 100 mV DC
S2: 1 – 5 V DC
GENERAL SPECIFICATIONS
Connection
■ Thermocouple
Input resistance: ≥ 1 MΩ
Burnout sensing: ≤ 3 μA
Input and output: Euro terminal (torque 0.3 N·m)
Power input: Via the Installation Base (model: M6DBS)
(not available for AC power input)
or Euro terminal (torque 0.3 N·m)
Minimum span: 20°C or 36°F
If not specified, the input range is shown below.
T1 PR: 0–1600°C
Applicable wire size: 0.2 to 2.5 mm , stripped length 8 mm
2
T2 K: 0–1000°C
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
T3 E: 0–500°C
T4 J: 0–500°C
Overrange output: -2 – +102 %
T5 T: 0–300°C
(Negative current output is not available.)
T6 B: 500–1600°C
Zero adjustment: -2 to +2 % (PC programming)
Span adjustment: 98 to 102 % (PC programming)
Burnout (thermocouple, RTD & potentiometer input):
Upscale standard; downscale or no burnout
optional by programming
T7 R: 500–1600°C
T8 S: 0–1600°C
TN N: 0–1000°C
■ RTD: 2- , 3- or 4-wire RTD
Maximum leadwire resistance: 10 Ω per wire
Sensing current: ≤ 1.0 mA
Minimum span: 20°C or 36°F
Resistance range:
Linearization (thermocouple & RTD input): Standard
Cold Junction Compensation (thermocouple input): CJC
sensor incorporated
Power LED: Green light turns on when the power is supplied.
Status indicator LED: Orange LED; Blinking patterns indicate
different operating status of the transmitter.
Programming: Downloaded from PC; input type and range,
output type and range, zero and span, burnout type,
linearization table, (max. 101 points, specified within -2 –
+102% for both input and output), user’s TC/RTD table
(max. 300 points, specified within -1000 to +1000 mV for
TC or 0 to 20 kΩ for RTD), etc.
0 - 500 Ω (Input code: 1, 3, 4, 5, 9)
0 - 5 kΩ (Input code: 7)
If not specified, the input range is 100°C.
■ Potentiometer
Sensing current: ≤ 1.0 mA
Minimum span
0 – 100 Ω : 10 Ω
0 – 300 Ω : 30 Ω
0 – 600 Ω : 60 Ω
For detailed information, refer to the users manual for the
0 – 1200 Ω : 120 Ω
M6DXU SPECIFICATIONS
ES-7853 Rev.5 Page 2/6
http://www.m-system.co.jp/
MODEL: M6DXU
0 – 2500 Ω : 250 Ω
input): ≤ 10 s
0 – 5000 Ω : 500 Ω
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
If not specified, the input range is 0 – 1200 Ω.
OUTPUT SPECIFICATIONS
■ DC Current
Output range: 0 – 20 mA DC
Accuracy
Conformance range: 0 – 20.4 mA DC
Minimum span: 1 mA
• DC voltage or current
Accuracy: Input accuracy + output accuracy
Inversely proportional to the span.
Input accuracy: (% of range)
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
-1000 – +1000 mV : ±0.01 %
Load resistance: Output drive 11 V max.
(e.g. 4 – 20 mA: 550 Ω [11 V ÷ 20 mA])
If not specified, the output range is 4 – 20 mA DC.
■ DC Voltage
-10 – +10 V : ±0.01 %
0 – 50 mA : ±0.02 % (Except the accuracy of input resistor.)
Output accuracy: ±0.04% of max. output range
[Example] Input Type -10 – +10 V, Input Range 1 – 5 V,
Output Type -5 – +5 V, Output Range 1 – 5 V
Input accuracy = Max. Input Range (20 V) ÷ Span (4 V) ×
0.01 % = 0.05 %
Code V2 (wide spans)
Output range: -10 – +10 V DC
Conformance range: -10.4 – +10.4 V DC
Minimum span: 1 V
Output accuracy = Max. Output Range (10 V) ÷ Span (4 V)
× 0.04 % = 0.1 %
Code V3 (narrow spans)
Output range: -5 – +5 V DC
Accuracy= ±0.15 %
Conformance range: -5.2 – +5.2 V DC
Minimum span: 0.5 V
• Thermocouple
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
Overall accuracy: Input accuracy + output accuracy
Input accuracy: Accuracy + Cold Junction Compensation
Error 3°C (5.4°F)
Load resistance: Output drive 1 mA max.
(e.g. 1 – 5 V: 5000 Ω [5 V ÷ 1 mA])
If not specified, the output range is shown below.
V2: 0 – 10 V DC
Output accuracy: Max. Output Range ÷ Span × ±0.04%
T/C
(PR)
ACCURACY (°C)
±1.00
CONFORMANCE RANGE (°C)
0 – 1760
V3: 1 – 5 V DC
K (CA)
E (CRC)
J (IC)
T (CC)
B (RH)
R
±0.25
-150 – +1370
-170 – +1000
-180 – +1200
-170 – +400
400 – 1760
±0.20
±0.25
INSTALLATION
Power Consumption
±0.25
±0.75
•AC: Max. 2 VA
±0.50
200 – 1760
•DC: Approx. 0.5 W
S
±0.50
0 – 1760
Operating temperature: -20 to +55°C (-4 to +131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Installation Base (model: M6DBS) or DIN rail
Weight: 65 g (2.3 oz)
N
±0.30
-130 – +1300
T/C
ACCURACY (°F)
±1.80
CONFORMANCE RANGE (°F)
32 – 3200
(PR)
K (CA)
E (CRC)
J (IC)
T (CC)
B (RH)
R
±0.45
-238 – +2498
-274 – +1832
-292 – +2192
-274 – +752
PERFORMANCE in percentage of span
Cold junction compensation error (thermocouple input):
±3°C at 25 ±10°C
±0.36
±0.45
±0.45
±5.4°F at 77 ±18°F
±1.35
752 – 3200
Temp. coefficient: ±0.01 %/°C (±0.006 %/°F) of max. span
Response time: (0 – 90 %)
±0.90
392 – 3200
S
±0.90
32 – 3200
DC voltage or current: ≤ 0.5 s
N
±0.54
-202 – +2372
Thermocouple, RTD, potentiometer: ≤ 1 s
Burnout response time (thermocouple, RTD, potentiometer
[Example] K thermocouple, 0 – 1000°C, 4 – 20 mA DC
ES-7853 Rev.5 Page 3/6
M6DXU SPECIFICATIONS
http://www.m-system.co.jp/
MODEL: M6DXU
output
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
Absolute accuracy in °C: 0.25°C (see the above table)
CJC error (3°C) added: 3.25°C
➠ Input accuracy = 3.25°C ÷ 1000°C × 100 = 0.325 %
Output span: 16 mA (20 – 4)
EN 50581
➠ Output accuracy = 20 mA ÷ 16 mA × 0.04 = 0.05 %
➠ Overall accuracy including CJC error = 0.325 + 0.05 =
±0.38 % of span
• RTD
Accuracy: Input accuracy + output accuracy
Inversely proportional to the span.
Input accuracy: (whichever is greater)
±0.1 % of input range or ±0.15°C (Pt and JPt)
±1°C (Cu 10)
Output accuracy: ±0.04% of max. output range
[Example] Pt 100, 0 – 100°C, Output Type -5 – +5V, Output
Range 1 – 5V
Input Accuracy* (0.15°C**) ÷ Span (100°C) × 100 %
+ Max. Output Range (10V) ÷ Span (4V) × 0.04 %
= ±0.25 %
* Calculate the accuracy in °C.
** 100°C × 0.1 % = 0.1°C ≤ 0.15°C. 0.15°C is used as input
accuracy value.
• Potentiometer
Accuracy: Input accuracy + output accuracy
Inversely proportional to the span.
Input accuracy: (% of range)
0 – 100 Ω : ±0.05 %
0 – 300 Ω : ±0.05 %
0 – 600 Ω : ±0.03 %
0 – 1200 Ω : ±0.03 %
0 – 2500 Ω : ±0.01 %
0 – 5000 Ω : ±0.01 %
Output accuracy: ±0.04% of max. output range
[Example] Total Resistance 0 – 1200 Ω, Input Range 250–
750 Ω, Output Type -5 – +5 V, Output Range 1 – 5 V
Max. Input Range (1200 Ω) ÷ Span (500 Ω) × 0.03 %
+ Max. Output Range (10 V) ÷ Span (4 V) × 0.04 %
= ±0.18 %
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II
Pollution Degree 2
M6DXU SPECIFICATIONS
ES-7853 Rev.5 Page 4/6
http://www.m-system.co.jp/
MODEL: M6DXU
EXTERNAL VIEW
■ FRONT VIEW (with the cover open)
■ SIDE VIEW
DIP switches for configuration
Power LED
5
6
7
8
Status Indicator LED
Configurator Jack
1
2
3
4
The DIP switch setting is required to select input and output
types before setting a precise range using PC Configurator
Software (model: M6CFG).
Refer to the instruction manual for detailed procedures.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
WIRE INSERTION ANGLE: approx. 7°
8–M3
EURO TERMINAL
DIN RAIL HOOK
5
6
7
8
DIN RAIL
35mm wide
1
2
3
4
SCREWDRIVER
INSERTION ANGLE
: approx. 40°
[0.5 (.02)]
5.9 (.23)
102 (4.02)
• When mounting, no extra space is needed between units.
M6DXU SPECIFICATIONS
ES-7853 Rev.5 Page 5/6
http://www.m-system.co.jp/
MODEL: M6DXU
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
*2
T/C
DC
RTD
POT.
DIP SW
DIP SW
CJC
SENSOR
STATUS LED
comp. leadwire
Isolation
Output
Driver
3-wire
A
4-wire
A
2-wire
A
+
+
+
+
max.
*1
Digital
Computation
1
2
3
4
5
6
+
–
3
Current Input (Z1)
–
OUTPUT
POWER
–
–
–
A
B
B
2
B
Low Drift
Amplifier
17Ω
Voltage Input (S1, S2)
+
POWER LED
7
8
U (+)
V (–)
B
B
1
–
min.
JACK
CONFIGURATOR
*3
POWER
*1. Input shunt resistor incorporated for current input.
*2. CJC sensor incorporated for thermocouple input.
*3. Available only for DC power input type
Specifications are subject to change without notice.
M6DXU SPECIFICATIONS
ES-7853 Rev.5 Page 6/6
http://www.m-system.co.jp/
M6DXU-S1R9-M2/Q 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
M6DXU-S1R9-R | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S1R9-R/Q | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2M1-M2 | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2M1-M2/Q | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2M1-R | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2M1-R/Q | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2R0-M2 | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2R0-M2/Q | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2R0-R | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 | |
M6DXU-S2R0-R/Q | MSYSTEM | Euro Terminal Ultra-Slim Signal Conditioners M6D Series | 获取价格 |
M6DXU-S1R9-M2/Q 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6