M2XPA3-A14V1-P [MSYSTEM]
Super-mini Signal Conditioners Mini-M Series;型号: | M2XPA3-A14V1-P |
厂家: | M-SYSTEM |
描述: | Super-mini Signal Conditioners Mini-M Series |
文件: | 总6页 (文件大小:156K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: M2XPA3
Pulse sensing: DC coupled
Super-mini Signal Conditioners Mini-M Series
Noise filter: None
Detecting level: 2 V
FREQUENCY TRANSMITTER
(PC programmable)
Frequency range: 0 – 200 kHz
Input zero frequency: 0 Hz
Input span frequency: 100 kHz
Linearization: No linearization
Low-end cutout: 0 % (No cutout)
Moving averaging samples: 1
Sensor excitation: 12 V DC / 20 mA
Output type: DC current
Output 0%: 4mA
Functions & Features
• Converts the output from a pulse-type transducer into a
standard process signal
• PC programmable
• Sensor excitation
• Direct RS-422 input
Typical Applications
Output 100%: 20mA
• Positive displacement flowmeters, turbine flowmeters and
vortex flowmeters
[1] INPUT
A1: Open collector
• Measuring rotation speed of a machine generating dry
contact signals
A2: Mechanical contact
B: Voltage pulse
23 (.91)
G: Two-wire current pulse
J: RS-422 line driver pulse
Configurator software is used to change the frequency
range. The input type can be switched to other than the one
of the selected suffix code by selecting the input type
selectors inside the unit before software adjustment.
M
od
el
76
(2.99)
124
(4.88)
[2] EXCITATION
2: 4 V DC / 20 mA
mm (inch)
3: 8 V DC / 20 mA
4: 12 V DC / 20 mA
MODEL: M2XPA3-[1][2][3]-[4][5]
Configurator software is used to change the excitation
value.
ORDERING INFORMATION
• Code number: M2XPA3-[1][2][3]-[4][5]
Specify a code from below for each [1] through [5].
(e.g. M2XPA3-A14Z1-R/CE/Q)
[3] OUTPUT
Current
Z1: Range 0 – 20 mA DC
• Input frequency (e.g. 0 – 10 kHz)
Voltage
• Output (e.g. 0 - 10 mA)
V1: Range -2.5 – +2.5 V DC
V2: Range -10 – +10 V DC
(Configurator software is used to adjust the output range
and to change the output over the described range of the
selected suffix code.)
• Specify the specification for option code /Q
(e.g. /C01/S01)
• Non-specified orders will be shipped at the default factory
settings as shown in below. However, a power suffix code
must be specified.
If you specify a full code number without specific calibration
ranges, the input and output ranges are factory set to the
default range.
Use Ordering Information Sheet (No. ESU-5104).
[Factory default setting]
PARAMETER: DEFAULT
Input type: Open collector
Input amplitude: ----
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 1/6
http://www.m-system.co.jp/
MODEL: M2XPA3
· I/O type and range
· Detecting level
[4] POWER INPUT
AC Power
· Sensor excitation
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
· Zero and span adjustments
47 – 66 Hz)
· Low-end cutout
(90 – 264 V for UL)
· Linearization
DC Power
· Sample number for the moving average
DIP switch settings:
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
• Input Type
• Pulse Sensing (Capacitor coupled, DC coupled)
• Noise Filter (High, Low, None)
Status indicator LED: Blinking patterns indicate different
operating status of the transmitter.
Excitation adjustment: 4 V, 8 V or 12 V DC
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
(110 V ±10 % for UL)
[5] OPTIONS (multiple selections)
Standards & Approvals (must be specified)
/N: Without CE or UL
/CE: CE marking
Low-end cutout: 0 – 115 % programmable;
No cutout with 0 % setting; hysteresis fixed at 1 % (factory
set to: No cutout)
/UL: UL approval, CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
TERMINAL SCREW MATERIAL
/S01: Stainless steel (UL not available)
RELATED PRODUCTS
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Chromated steel (standard) or stainless
steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -15 to +115 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
Configuration: Via PC Configurator Software (model: JXCON)
on the Windows PC connected to the front jack.
Programmable features include:
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 2/6
http://www.m-system.co.jp/
MODEL: M2XPA3
[Table 1]
INPUT SPECIFICATIONS
Excitation: Shortcircuit protection; 30 mA max. at
shortcircuit
SENSITIVITY
SCALE
PULSE
AMPLITUDE
MAX. VOLTAGE AT
INPUT TERMINALS
50 – 100 Vp-p
25 – 50 Vp-p
10 – 25 Vp-p
5 – 10 Vp-p
100 V*
50 V
25 V
10 V
5 V
1/20
1/10
1/5
1/2
1
Frequency ranges:
0 – 10 mHz, 0 – 100 mHz, 0 – 1 Hz, 0 – 10 Hz, 0 – 100 Hz,
0 – 1 kHz, 0 – 10 kHz, 0 – 200 kHz
1 – 5 Vp-p
(up to 10 Hz for mechanical contact)
If not specified, Input frequency factory default will be 0 –
100 kHz.
0.5 – 1 Vp-p
0.1 – 0.5 Vp-p**
1 V
5
0.5 V
10
Open collector
Mechanical contact
2-wire current pulse
(0 – 10 Hz for mechanical contact)
----
1
Minimum pulse width time requirement: 2.5 μsec. for both
ON and OFF. (50 msec. for mechanical contact)
Minimum span: 10 % of the selected frequency range
(5 % of the selected frequency range when the range is
0 – 200 kHz.)
*Limited to ≤70V for CE conformance or UL approval.
**Input frequency ≤50 kHz
A specific sensitivity scale is applied according to the pulse
amplitude by setting up the DIP switch and PC Configurator
Software (model: JXCON). The scaled input voltage is then
compared to the detecting level at -2.00 through +4.00V.
With DC coupling, the scaled maximum input voltage level
voltage must be higher than and the scaled minimum input
voltage level must be lower than the detecting level so that
the pulse state is accurately detected.
Noise filter: See Table 2
Choose the noise filter type appropriate for the selected
frequency range to ensure the described accuracy.
■ Open Collector & Mechanical Contact
Input requirements
[Table 2]
FREQUENCY RANGE
0 – 10 mHz
0 – 100 mHz
0 – 1 Hz
NOISE FILTER
High
EXC
SENSING
OFF
ON
4V Approx. 3V/0.7mA ≥2kΩ/1V ≤200Ω/0.2V
8V Approx. 6V/1.5mA ≥4kΩ/3V ≤600Ω/1V
12V Approx. 9V/2.3mA ≥2kΩ/3V ≤400Ω/1V
Detecting level (detecting voltage in the internal circuit)
factory default: 0.6 V (4 V excitation)
2 V (8 V / 12 V excitation)
High
Low
0 – 10 Hz
Low
0 – 100 Hz
Low
0 – 1 kHz
Low
0 – 10 kHz
None
None
0 – 200 kHz
■ Voltage Pulse
Choose the noise filter type appropriate for the selected
frequency range to ensure the described accuracy.
Waveform: Square or sine
Input impedance: ≥ 10 kΩ
Input amplitude: Min. 0.1 Vp-p, max. 100 Vp-p
Max. voltage between input terminals: See table 1.
Detecting level (detecting voltage in the internal circuit):
-2 – +4 V
■ Two-wire Current Pulse
Input resistance: Receiving resistor 100 Ω
Input range: 0 – 25 mA
Input amplitude: Min. 10 mAp-p, max. 25 mAp-p
Detecting level (detecting voltage in the internal circuit):
-2 – +4 V
■ RS-422 Line Driver Pulse
Receiver: Conforms to RS-422
■ VOLTAGE PULSE
Volts
100V max.
Amplitude
Vinp-p
DC Offset
t
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 3/6
http://www.m-system.co.jp/
MODEL: M2XPA3
at -5 to +55°C [23 to 131°F]
OUTPUT SPECIFICATIONS
■ DC Current
Response time: 0.5 sec. + 1 pulse cycle (0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
Output range: 0 – 20 mA DC
Conformance range: 0 – 24 mA DC
Minimum span: 1 mA
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
CALCULATION EXAMPLES OF OVERALL ACCURACY
[Example] Open collector input, 0 – 50 kHz; 1 – 5 V output.
Selected freq. range (100 kHz) ÷ Input span (50 kHz)×
Accuracy (0.03 %)= 0.06 % (Input accuracy)
Load resistance: Output drive 12 V max.
(e.g. 4 – 20 mA: 600 Ω [12 V ÷ 20 mA])
If not specified, the output range is 4 – 20 mA DC.
■ DC Voltage
Selected output range (20 V) ÷ Output span (4 V) ×
Accuracy (0.03 %)= 0.15 % (Output accuracy)
Code V1 (narrow spans)
Conformance range: -3 – +3 V DC
Output range: -2.5 – +2.5 V DC
Minimum span: 250 mV
Overall accuracy = 0.06 + 0.15 = ±0.21 %
STANDARDS & APPROVALS
EU conformity:
Code V2 (wide spans)
Conformance range: -11.5 – +11.5 V DC
Output range: -10 – +10 V DC
Minimum span: 1 V
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
Low Voltage Directive
EN 61010-1
Installation Category II
Load resistance: Output drive 1 mA max.
(e.g. 1 – 5 V: 5000 Ω [5 V ÷ 1 mA])
If not specified, the output range is shown below.
V1: 0 – 1 V DC
Pollution Degree 2
Input or output to power: Reinforced insulation (300 V)
Input to output: Basic insulation (300 V)
RoHS Directive
V2: 1 – 5 V DC
EN 50581
Approval:
INSTALLATION
Power Consumption
UL/C-UL nonincendive Class I, Division 2,
Groups A, B, C, and D
•AC:
(ANSI/ISA-12.12.01, CAN/CSA-C22.2 No.213)
UL/C-UL general safety requirements
(UL 61010-1, CAN/CSA-C22.2 No.61010-1)
Approx. 4 VA at 100 V
Approx. 5 VA at 200 V
Approx. 6 VA at 264 V
•DC: Approx. 2 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lb)
PERFORMANCE
Accuracy: Input accuracy + output accuracy
Inversely proportional to the span.
Input accuracy: ±0.03 % of the selected freq. range
(The input span 100 kHz is used for calculation with 0 – 200
kHz range. The input accuracy is fixed at ±0.03 % when
[Frequency range ÷ Input span] equals 1 or less.)
Output accuracy: ±0.03 % of the selected output range
See CALCULATION EXAMPLES OF OVERALL ACCURACY.
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of I/O range
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 4/6
http://www.m-system.co.jp/
MODEL: M2XPA3
EXTERNAL VIEW
FRONT VIEW (with cover open)
LEFT SIDE VIEW (with cover removed)
Configurator Jack
Status Indictor LED
Selector SW
OFF
ON
1
2
3
4
Zero/Span Selector
SW4
Top: SPAN
Middle: OFF
Bottom: ZERO
UP/DOWN Switches
L
L
L
H
H
H
The front cover cannot be opened to 180 deg.
when flush with neighboring units.
SW1 SW2 SW3
Refer to the instruction manual for detailed procedures.
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
6 (.23)
DIN RAIL
35mm wide
4
1
5
8
2–4.2x5
(.17x.20)
MTG HOLE
6 (.24) deep
12
9
8–M3
SCREW
14 13
21.5 (.85) 7.3 (.29)
86.7 (3.41)
116.7 (4.59)
15 (.59)
[4 (.16)]
23 (.91)
• When mounting, no extra space is needed between units.
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 5/6
http://www.m-system.co.jp/
MODEL: M2XPA3
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
STATUS
MON.
INPUT TYPE
SELECTOR
ZERO/SPAN
SELECTOR
Isolation
Digital
Computation
Output
Driver
1
9
+
Waveform
Shaper
OUTPUT
4
12
13
14
–
INPUT *1
UP/DOWN
SWITCHES
5
U(+)
V(–)
Excitation
Supply
POWER
8
JACK
CONFIGURATOR
Base Socket
*1. Input Connection Examples
■ Open Collector
or Mechanical Contact
■ Voltage Pulse
■ RS-422 Line Driver Pulse
+
+
–
–
+
1
4
5
+
–
–
+
1
4
5
1
4
5
INPUT
–
+
Vsns
Vsns
PWR
PWR
5kΩ
PWR
Vsns
8
–
■ 2-Wire Current Pulse
• Built-in Excitation
• External DC Supply
DC SUPPLY
100Ω
100Ω
4
–
+
4
5
8
Vsns
Vsns
+
–
5
8
2-WIRE
PICK-UP
+
–
2-WIRE
PICK-UP
EXPLANATIONS OF TERMS
Low-end cutout:
The function where the output signal is forced to 0% below the setpoint input. Hysteresis is fixed at 1%.
[Example] Input zero frequency 0 Hz
Input span frequency 1 kHz
Low-end cutout 10 %
OUTPUT
INPUT
0%
10% 11%
100%
1 kHz
0 Hz 100 Hz 110 Hz
Specifications are subject to change without notice.
M2XPA3 SPECIFICATIONS
ES-5104 Rev.14 Page 6/6
http://www.m-system.co.jp/
相关型号: