LCF-4D-H [MSYSTEM]

Plug-in Signal Conditioners M-UNIT;
LCF-4D-H
型号: LCF-4D-H
厂家: M-SYSTEM    M-SYSTEM
描述:

Plug-in Signal Conditioners M-UNIT

文件: 总4页 (文件大小:115K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: LCF  
6: 10 mV/V  
7: 20 mV/V  
Plug-in Signal Conditioners M-UNIT  
0: Specify (strain gauge and excitation)  
STRAIN GAUGE TRANSMITTER  
(remote sensing, super-high speed, 10 V / 120 mA  
excitation)  
[2] OUTPUT  
Current  
Functions & Features  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
•Provides a DC output signal compatible with a bridge type  
strain gauge utilized in load cells, pressure transducers  
•Response time 300 μsec.  
•Six-wire remote sensing compensates for lead resistance  
variations  
•Excitation adjustable from 2 V to 10 V, max. 120 mA  
•Wide-range adjustment: 0 – 80 % for zero, 100 – 20 % for  
span  
•Isolation up to 2000 V AC  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
•High-density mounting  
Typical Applications  
• Weighing system for tanks, hoppers, silos  
• Weighing system using cranes  
• Float level meter utilizing strain gauges  
50  
(1.97)  
80  
(3.15)  
[3] POWER INPUT  
AC Power  
B: 100 V AC  
C: 110 V AC  
136  
(5.35)  
F: 120 V AC  
mm (inch)  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
MODEL: LCF–[1][2]–[3][4]  
[4] OPTIONS (multiple selections)  
Input Signal Indicator  
ORDERING INFORMATION  
• Code number: LCF-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. LCF-2A-B/E/Q)  
blank: Without  
/E: With (0.0 - 100.0 % display)  
Other Options  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
[1] INPUT STRAIN GAUGE  
1: 1 mV/V  
12: 1.25 mV/V  
15: 1.5 mV/V  
2: 2 mV/V  
/C02: Polyurethane coating  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
3: 3 mV/V  
4: 4 mV/V  
5: 5 mV/V  
LCF SPECIFICATIONS  
ES-1358 Rev.9 Page 1/4  
https://www.m-system.co.jp/  
MODEL: LCF  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Linearity: ±0.05 %  
Display accuracy: ±(0.1 % of FS + 1 digit)  
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)  
Response time: ≤ 300 μsec. (0 – 90 %), 2 kHz (-3 dB)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @ 1 minute (input or output  
to power to ground)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Excitation: Adjustable from 2 to 10 V (front); limited to ≤ 15  
V when the remote sensing terminals are open.  
Zero adjustments (tare): 0 – 80 % (front)  
(Excitation voltage: factory default)  
Span adjustment: 100 – 20 % (front)  
(Excitation voltage: factory default)  
■ DISPLAY (Input indicator)  
1000 V AC @ 1 minute (input to output)  
STANDARDS & APPROVALS  
EU conformity:  
EMC Directive  
LCD digital display: 0.0 - 100.0 % (min. digit 0.1 %)  
(No scaling)  
EMI EN 61000-6-4  
EMS EN 61000-6-2  
Low Voltage Directive  
EN 61010-1  
INPUT SPECIFICATIONS  
Input: Bridge voltage from load cells  
Allowable leadwire resistance:  
Installation Category II  
Pollution Degree 2  
Total Resistance [Ω] (of all wires) < (Bridge Resistance [Ω] /  
Excitation [V]) × 1.2 [V]  
Input or output to power – Basic insulation (300 V)  
RoHS Directive  
Strain Gauge  
Rated output from strain gauge: 1 – 20 mV/V;  
Input to the LCF must be over 3 mV.  
Excitation: 2 – 10 V adjustable (5 V standard)  
Maximum current: 120 mA  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max. at ≥ 0.5 V  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
50/60 ± 2 Hz, approx. 5 VA  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 400 g (0.88 lb)  
LCF SPECIFICATIONS  
ES-1358 Rev.9 Page 2/4  
https://www.m-system.co.jp/  
MODEL: LCF  
EXTERNAL VIEW  
LCD Meter  
Excitation Adj.  
Coarse Zero Adj.  
Fine Zero Adj.  
Coarse Span Adj.  
Fine Zero Adj.  
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
8
7
6
5
4
2–  
4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
9
3
2
10 11  
1
11  
M3.5  
SCREW  
50 (1.97)  
107 (4.21)  
136 (5.35)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
*
Isolation  
STRAIN  
GAUGE  
Z
S
Output  
Driver  
+
+
10  
11  
3
1
2
Low Drift  
Amplifier  
OUTPUT  
EXC.  
+
Low Drift  
DC Volt.  
Stabilizer  
9
S +  
S –  
U
V
4
7
8
Remote  
Sensing  
POWER  
5
6
Base Socket  
Close across the terminal 3 – 4 and 5 – 9 when the remote sensing is not used.  
*Option /E  
LCF SPECIFICATIONS  
ES-1358 Rev.9 Page 3/4  
https://www.m-system.co.jp/  
MODEL: LCF  
Specifications are subject to change without notice.  
LCF SPECIFICATIONS  
ES-1358 Rev.9 Page 4/4  
https://www.m-system.co.jp/  

相关型号:

LCF-4D-H/E

Plug-in Signal Conditioners M-UNIT
MSYSTEM

LCF-4D-H/Q

Plug-in Signal Conditioners M-UNIT
MSYSTEM

LCF-4D-J

Plug-in Signal Conditioners M-UNIT
MSYSTEM

LCF-4D-J/E

Plug-in Signal Conditioners M-UNIT
MSYSTEM

LCF-4D-J/Q

Plug-in Signal Conditioners M-UNIT
MSYSTEM

LCF060502A650TG

Data Line Filter,
LITTELFUSE

LCF060502B650TG

Data Line Filter,
LITTELFUSE

LCF080602A250TG

Data Line Filter,
LITTELFUSE

LCF080602A750TG

LCF Series covers the specification of the engineering requirements for both Common Mode Noise Filter (CMF) for high speed differential serial interfaces
LITTELFUSE

LCF080602A900TG

LCF Series covers the specification of the engineering requirements for both Common Mode Noise Filter (CMF) for high speed differential serial interfaces
LITTELFUSE

LCF080602B750TG

LCF Series covers the specification of the engineering requirements for both Common Mode Noise Filter (CMF) for high speed differential serial interfaces
LITTELFUSE

LCF080602G900TG

LCF Series covers the specification of the engineering requirements for both Common Mode Noise Filter (CMF) for high speed differential serial interfaces
LITTELFUSE