KS2V2-61-R [MSYSTEM]
Plug-in Signal Conditioners K-UNIT;型号: | KS2V2-61-R |
厂家: | M-SYSTEM |
描述: | Plug-in Signal Conditioners K-UNIT |
文件: | 总4页 (文件大小:142K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: KS2V2
Plug-in Signal Conditioners K-UNIT
[2] OPTIONS
blank: none
/Q: Options other than the above (specify the specification)
DC INPUT LIMIT ALARM
(digital adjustments; dual alarm trip; burnout)
Functions & Features
SPECIFICATIONS OF OPTION: Q
EX-FACTORY SETTING
• Providing relay contact closures at preset DC input levels
• Dual (Hi/Lo) trip
/SET: Preset according to the Ordering Information Sheet
(No. ESU-3608)
• Front digital displays
• Programmable with front keys
RELATED PRODUCTS
• Resistor module (model: REM)
500 Ω for 2 – 10 mA DC
Typical Applications
• Various alarm applications
250 Ω for 4 – 20 mA DC
50 (1.97)
100 Ω for 10 – 50 mA DC
70 (2.76)
110 (4.33)
mm (inch.)
MODEL: KS2V2–61–[1][2]
ORDERING INFORMATION
• Code number: KS2V2-61-[1][2]
Specify a code from below for each of [1] and [2].
(e.g. KS2V2-61-R/Q)
• Specify the specification for option code /Q
(e.g. /SET)
INPUT
Voltage
6: 1 – 5 V DC
(Use a resistor module for current input)
OUTPUT
1: Relay; SPDT or transfer contact
[1] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
KS2V2 SPECIFICATIONS
ES-3608 Rev.10 Page 1/4
https://www.m-system.co.jp/
MODEL: KS2V2
Measured Value (PV) indicator: Green LED turns on when PV
display is set.
GENERAL SPECIFICATIONS
Construction: Panel flush mounting, plug-in
Connection: M3.5 screw terminals
Alarm SET1 indicator: Red LED turns on when the Alarm
SET1 is in tripped conditions.
Screw terminal: Chromated steel
Alarm SET2 Indicator: Red LED turns on when the Alarm
SET2 is in tripped conditions.
Housing material: Flame-resistant resin (gray)
Isolation: Input to SET1 to SET2 to power
Time constant for the input filter (P-dF): 0.0 to 900.0 sec. (0
– 63 %)
Engineering unit indication: Sticker label attached;
DC, AC, W, °C, °F, V, mV, A, mA, %, kW, mW,
kV, kA, kvar, Mvar, var, m, mm, kg, kg/h,
Alarm relay switching delay time (P-d1, P-d2): 1 to 10 sec.;
programmable independently for each setpoint
Programming: Front key
kPa, MPa, N·m, Nm
3
/h, m
3
/h, m /sec, m/sec,
3
ℓ/min, %RH, ℓ, ℓ/h, t/h, rpm, ppm, pH, Pa.
Setpoint adjustment (ST1, ST2): -5 to +105 %;
programmable independently for each setpoint
Deadband (hysteresis) (HYS1, HYS2): 0 – 102 %;
programmable independently for each setpoint
Burnout: Upscale (standard), downscale (available to
change)
INPUT SPECIFICATIONS
■ DC Voltage: -5 – +105 %
Input resistance: ≥ 1 MΩ
OUTPUT SPECIFICATIONS
■ Relay Contact: SPDT relays
Power ON delay (P-d0): 0 to 20 sec.
Read rate: 0.5 sec.
220 V AC @3 A (cos ø = 1)
Alarm mode (P-A1, P-A2): Programmable independently for
each setpoint; See Table below.
30 V DC @3 A (resistive load)
Caution: N.O. and N.C. contacts could be conductive at the
same time. DO NOT connect both contacts at the same
time.
Param.
Code
Alarm Modes
Latching
Hold*
Trip
Operation
Set Value
Relay & LED
Behavior in
Tripped Conditions
(P-A1)
(P-A2)
Maximum switching voltage: 220 V AC or 30 V DC
Maximum switching power: 660 VA or 90 W
Minimum load: 10 V DC @1 mA
0
1
No alarm
High
----
----
----
Absolute value
Without
LED ON
Coil energized
2
3
4
5
6
7
8
Low
High
Low
High
Low
High
Low
Absolute value
Absolute value
Absolute value
Absolute value
Absolute value
Absolute value
Absolute value
Without
With
LED ON
Coil energized
Mechanical life: 2 × 10 cycles with no loads
7
For maximum relay life with inductive loads, external
protection is recommended.
LED ON
Coil energized
With
LED ON
Coil energized
Without
Without
With
LED ON
Coil de-energized
INSTALLATION
Power consumption
LED ON
Coil de-energized
•AC:
LED ON
Coil de-energized
Approx. 3.1 VA at 100 V
Approx. 4.1 VA at 200 V
With
LED ON
Coil de-energized
Approx. 4.8 VA at 264 V
*Without latching hold function, the unit is tripped upon starting operation when
the unit is set to Low alarm.
•DC: Approx. 1.7 W
With the function, the unit is NOT tripped until the temperature goes once above
and then below the setpoint.
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting with attached
mounting bracket, surface or DIN rail
Weight: 200 g (0.44 lb)
DISPLAY
Display: 4 digits of 10 mm (.39”) height, 7-segment LED
Scaling range: -1999 to 9999 counts
Measured Value (PV)/Alarm (SET1) display: Red LEDs
Alarm (SET2) parameter display: Green LEDs
PV display at abnormal input: Over range or under range
displayed
PERFORMANCE
Display accuracy: ±0.5% FS ±1 digit
Setpoint accuracy: Display accuracy ± 0.1 % FS
Trip point repeatability: Included in the setpoint accuracy
Line voltage effect: Included in the display accuracy
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute
Front LEDs
Power indicator: Green LED turns on while the power is
turned on.
KS2V2 SPECIFICATIONS
ES-3608 Rev.10 Page 2/4
https://www.m-system.co.jp/
MODEL: KS2V2
(input to SET1 or SET2 to power)
500 V AC @1 minute (SET1 to SET2)
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
Installation Category II (power)
Measurement Category II (output)
Pollution Degree 2
Input to output to power: Basic insulation (300 V)
RoHS Directive
EXTERNAL VIEW
H. Alarm SET1 Indicator LED
J. Alarm SET2 Indicator LED
G. Power Indicator LED
A. Measured Value (PV) /
Alarm SET1 Display
B. Measured Value (PV)
Indicator LED
C. Alarm SET2 / Parameter Display
D. SELECT Key
F. DOWN Key
E. UP Key
Component Name
Ref.
Function
A
B
Measured Value (PV) / Alarm SET1 Display Displaying either of Measured Value (PV) or Alarm Setpoint Value (SET1)
LED turns on when the Measured Value (PV) is displayed.
Measured Value (PV) Indicator LED
Alarm SET2 / Parameter Display
SELECT Key
Displaying either of Alarm Setpoint Value (SET2) or parameter type code.
Used for confirming current setpoints and switching between parameter blocks.
C
D
E
F
Pressing the key increases display values.
UP Key
They change continuously when it is kept pressed.
Pressing the key decreases display values.
DOWN Key
They change continuously when it is kept pressed.
LED turns on while the power is turned on.
Power Indicator LED
Alarm SET1 Indicator LED
Alarm SET2 Indicator LED
G
H
J
LED turns on when the Alarm SET1 is in tripped conditions.
LED turns on when the Alarm SET2 is in tripped conditions.
KS2V2 SPECIFICATIONS
ES-3608 Rev.10 Page 3/4
https://www.m-system.co.jp/
MODEL: KS2V2
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
CLAMP
110 (4.33)
(top & bottom)
7.5
(.3)
71.5 (2.81)
1.5 (.06) PACKING
7.8 (.31)
48 (1.89)
DIN RAIL
35mm wide
8
7
6
5
4
3
2–4.5 (.18) dia.
MTG HOLE
25 (.98) deep
9
10 11
1
2
MOUNTING
BRACKET
1 1–M3.5
SCREW
PANEL
t
[3.5] (.14)
40 (1.57)
50 (1.97)
1 ≤ t ≤ 8
(.04 ≤ t ≤.31)
PANEL CUTOUT unit: mm
■PANEL CUTOUT
+0.5
45 0
63 MIN.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
5
6
4
11 N.C.
10 N.O. SET1
+
–
RY
INPUT
A/D
Converter
9
3
2
1
7
8
COM
Digital
Computation
N.C.
RY
N.O. SET2
COM
Display/
Setting
U(+)
POWER
V(–)
Base Socket
Specifications are subject to change without notice.
KS2V2 SPECIFICATIONS
ES-3608 Rev.10 Page 4/4