MODEL: FLM  
FW: -10 – +10 mA DC (Input resistance 100 Ω)  
Space-saving Plug-in Signal Conditioners F-UNIT  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
LIMITER  
(non-isolated)  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
Functions & Features  
• Preventing DC output signals from going above or below  
preset values  
• High and low limits independently adjustable over entire  
range  
• Monitor jacks provided for setpoint adjustments  
• High-density mounting  
Typical Applications  
• Securing the minimum fuel flow in a combustion control  
loop  
[2] OUTPUT  
Current  
26 (1.02)  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
100  
(3.94)  
137  
(5.39)  
mm (inch)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)  
5W: -5 – +5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
MODEL: FLM–[1][2]–[3][4]  
ORDERING INFORMATION  
• Code number: FLM-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. FLM-6A-P/Q)  
• Special input and output ranges (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[3] POWER INPUT  
AC Power  
[1] INPUT  
Current  
K: 85 – 132 V AC  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
L: 170 – 264 V AC  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
J: 0 – 10 μA DC (Input resistance 1000 Ω)  
K: 0 – 100 μA DC (Input resistance 1000 Ω)  
GW: -1 – +1 mA DC (Input resistance 1000 Ω)  
(Operational voltage range 170 – 264 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
P: 110 V DC  
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
FLM SPECIFICATIONS  
ES-1484 Rev.6 Page 1/4  
http://www.m-system.co.jp/  
MODEL: FLM  
110 V approx. 20 mA  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail; Standard Rack Mounting  
Frame BX-16H available  
/C02: Polyurethane coating  
/C03: Rubber coating  
Weight: 200 g (0.44 lb)  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
PERFORMANCE in percentage of span  
Accuracy: ±0.1 %  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Limit monitor accuracy: ± 0.25 %  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: ≤ 0.5 sec. (0 – 90 %)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength  
Connection: M3.5 screw terminals (torque 0.8 N·m)  
Screw terminal: Nickel-plated steel (standard) or stainless  
steel  
Housing material: Flame-resistant resin (black)  
Isolation: Input or output to power  
Power input code R:  
Overrange output: Approx. -5 to +105 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
2000 V AC @ 1 minute (input or output or power to ground)  
500 V AC @ 1 minute (I/O to power)  
Power input code K, L, P:  
Span adjustment: 95 to 105 % (front)  
Limit adjustments: Multi-turn screwdriver adjustments  
(front); 0 – 100 %; factory set to 0 % for low, 100 % for high  
Monitor output: 0 – 10 V for 0 – 100 % limit  
Monitor jacks: 2 mm (.08") dia.  
2000 V AC @ 1 minute (input or output or power to ground)  
1500 V AC @ 1 minute (I/O to power)  
INPUT SPECIFICATIONS  
DC Current:  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 3 mV  
Offset: Max. 1.5 times span  
Input resistance  
Span 3 – 10 mV : ≥ 10 kΩ  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 0.5 V  
INSTALLATION  
Power input  
AC: Approx. 4.5 VA  
DC: 24 V approx. 70 mA  
FLM SPECIFICATIONS  
ES-1484 Rev.6 Page 2/4  
http://www.m-system.co.jp/  
MODEL: FLM  
EXTERNAL VIEW  
Hi Limit Monitor (+)  
Lo Limit Monitor (+)  
COM. (–)  
Zero Adj.  
Span Adj.  
Hi Limit Adj.  
Lo Limit Adj.  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
1
2
15  
(.59)  
DIN RAIL  
35mm wide  
3
4
2–4.5 (.18)  
HOLE  
15 (.59) deep  
5
6
8–M3.5  
SCREW  
7
8
26 (1.02)  
107 (4.21)  
137 (5.39)  
26 (1.02)  
[3.3 (.13)]  
•When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM)  
1
2
3
4
5
6
7
8
Input shunt resistor attached  
for current input.  
FLM SPECIFICATIONS  
ES-1484 Rev.6 Page 3/4  
http://www.m-system.co.jp/  
MODEL: FLM  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
COM. HI  
LO  
Z
S
Low Drift  
Amplifier  
Hi / Lo  
Limiter  
Output  
Driver  
+
1
2
3
4
5
6
7
8
+
*
INPUT  
R
OUTPUT  
POWER  
U(+)  
V(–)  
Base Socket  
*Input shunt resistor attached for current input.  
Specifications are subject to change without notice.  
FLM SPECIFICATIONS  
ES-1484 Rev.6 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

FLM-ZZ-K

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-K/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-L

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-L/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-P

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-P/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-R

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM-ZZ-R/Q

Space-saving Plug-in Signal Conditioners F-UNIT
MSYSTEM

FLM.0S.306.CLAD42Z

CONN CIRC PLUG 6POS SOLDER CUP
ETC

FLM.250

Electric Fuse, Time Lag Blow, 0.25A, 10000A (IR), MIDGET,
LITTELFUSE

FLM.400

Electric Fuse, Time Lag Blow, 0.4A, 10000A (IR), MIDGET,
LITTELFUSE

FLM.500

Electric Fuse, Time Lag Blow, 0.5A, 10000A (IR), MIDGET,