FASD-61-K [MSYSTEM]
Space-saving Plug-in Signal Conditioners F-UNIT;型号: | FASD-61-K |
厂家: | M-SYSTEM |
描述: | Space-saving Plug-in Signal Conditioners F-UNIT |
文件: | 总3页 (文件大小:125K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: FASD
Space-saving Plug-in Signal Conditioners F-UNIT
SETPOINT ADJUSTMENTS
1: Thumbwheel switch
DC ALARM
(thumbwheel switch adjustment)
[2] POWER INPUT
Functions & Features
AC Power
• Providing SPDT relay contact closures at preset DC input
levels
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
L: 170 – 264 V AC
• Dual (Hi/Lo) trip
• Thumbwheel switch setpoint adjustments
• Enclosed relays
(Operational voltage range 170 – 264 V, 47 – 66 Hz)
DC Power
• Relays can be powered 110 V DC
• High-density mounting
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
Typical Applications
• Annunciator
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
• Various alarm applications
[3] OPTIONS
blank: none
26 (1.02)
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
113
(4.45)
HI
4
3
4
/C02: Polyurethane coating
1
LO
/C03: Rubber coating
148
(5.83)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
mm (inch)
MODEL: FASD–[1]1–[2][3]
GENERAL SPECIFICATIONS
Construction: Plug-in
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
ORDERING INFORMATION
• Code number: FASD-[1]1-[2][3]
Specify a code from below for each of [1] through [3].
(e.g. FASD-61-R/Q)
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
• Specify the specification for option code /Q
(e.g. /C01/S01)
Setpoint adjustments: Thumbwheel switches (front); 0 – 99
% independently; 1 % increments
Hysteresis (deadband): Approx. 1 %
Front LEDs: Red LED turns on when the coil for Hi output is
energized.
[1] INPUT
Current
A1: 4 – 20 mA DC (Input resistance 50 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
Voltage
Green LED turns on when the coil for Lo output is energized.
INPUT SPECIFICATIONS
■ DC Current: Input resistor incorporated
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
OUTPUT SPECIFICATIONS
■ Relay Contact: 100 V AC @ 1 A (cos ø = 1)
120 V AC @ 1 A (cos ø = 1)
OUTPUT
Relay; SPDT or transfer contact
240 V AC @ 0.5 A (cos ø = 1)
30 V DC @ 1 A (resistive load)
FASD SPECIFICATIONS
ES-1416 Rev.7 Page 1/3
http://www.m-system.co.jp/
MODEL: FASD
Maximum switching voltage: 380 V AC or 125 V DC
Maximum switching power: 120 VA or 30 W
Minimum load: 5 V DC @ 10 mA
Mechanical life: 5 x 10 cycles
7
For maximum relay life with inductive loads, external
protection is recommended.
Alarm Trip Operation Terminal No. in parentheses
(1–2)ON
Hi Output
(1–3)ON
(9–10)ON
Lo Output
(9–11)ON
Input
(%)
0
▲
50
▲
100
Lo Setpoint
Hi Setpoint
Trip Operation in Power Failure
: Terminals 1 – 3, 9 – 11 turn ON.
INSTALLATION
•AC: Approx. 3 VA
•DC: Approx. 3 W (130 mA at 24 V)
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail; Standard Rack Mounting
Frame BX-16H available
Weight: 210 g (0.46 lb)
PERFORMANCE in percentage of span
Setpoint accuracy: ±0.5 %
Trip point repeatability: ±0.05 %
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @1 minute (input to output
to power to ground)
EXTERNAL VIEW
Hi Monitor LED
Hi Setpoint Adj.
9 9
Lo Setpoint Adj.
9 9
Lo Monitor LED
FASD SPECIFICATIONS
ES-1416 Rev.7 Page 2/3
http://www.m-system.co.jp/
MODEL: FASD
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
CLAMP
7.8 (.31)
(top & bottom)
11 12
1
2
15
(.59)
DIN RAIL
35mm wide
3
4
2–4.5 (.18)
HOLE
15 (.59) deep
5
6
12–M3.5
SCREW
7
8
9
10
26 (1.02)
107 (4.21)
148 (5.83)
26 (1.02)
[3.3 (.13)]
•When mounting, no extra space is needed between units.
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ Relay Protection
•AC Powered
THUMBWHEEL
SWITCHES
D / A
Converter
Inductive
Load (Coil)
9 9
Varistor or Spark
Quenching Circuit
3
2
LOAD
Low Drift
Amplifier
+
–
Ry
Ry
5
6
Comparator
Comparator
HI OUTPUT
LO OUTPUT
*
INPUT
U
1
•DC Powered
Inductive
Load (Coil)
4
11
10
9
Diode, Varistor or
CR Circuit
12
LOAD
THUMBWHEEL
SWITCHES
D / A
Converter
9 9
U(+)
7
POWER
V(–)
8
Base Socket
* Input shunt resistor incorporated for current input.
Specifications are subject to change without notice.
FASD SPECIFICATIONS
ES-1416 Rev.7 Page 3/3
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明