DL8-B-R/C02 [MSYSTEM]
WEB-ENABLED REMOTE TERMINAL UNIT;型号: | DL8-B-R/C02 |
厂家: | M-SYSTEM |
描述: | WEB-ENABLED REMOTE TERMINAL UNIT |
文件: | 总9页 (文件大小:887K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: DL8
SLMP Client, Web server (HTTP, HTTPS), reporting by e-mail,
FTP server/client, FTPS server/client, data logger, I/O mapping,
user-defined Web browser view
Web Data Logger DL8
WEB-ENABLED REMOTE TERMINAL UNIT
Functions and features
POWER INPUT
DC power
• Remote monitoring of equipment and plants by using
modern communication infrastructure
R: 24 V DC
• Monitoring and logging of a wide variety of signals
including temperature, pressure, voltage, discrete signal
status
(Operational voltage range: ±10 %; ripple 10 %p-p max.)
• Flexible I/O types and scalable points by combining built-
in R8 Series I/O modules
[2] OPTIONS
blank: none
• Type A has basic 'Browsing' function with web browser.
• Type B is added with 'Reporting' function by e-mails.
• Type C is added with 'Recording' function with SD card.
• Type D is added with 'Advanced' functions of peer-to-peer
connection of I/O signals and customized web browser view.
• Type E is added with 'Expanded Communication' functions
of SLMP client, HTTPS, and FTPS protocols.
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
50
(1.97)
RELATED PRODUCTS
R8 series remote I/O modules
(model: R8-SS2, R8-SS4NJ, R8-SS4N, R8-SST8, R8-SV2,
R8-SV4N, R8-FS16N, R8-TS2, R8-RS4N, R8-CT4E, R8-YS2,
R8-YS2NJ, R8-YST4N, R8-YV4N, R8-PA4, R8-PA4F, R8-PC4A,
R8-DA4A, R8-DAM16A, R8-DAT16A2, R8-DC4A, R8-DC4A2,
R8-DC4C, R8-DCT4D, R8-DCM16A, R8-DCM16ALZ,
R8-DCM16ALK, R8-DCM16ALH, R8-DCM32B2, R8-DCT16A2,
R8-PS1)
115
(4.53)
73
(2.87)
mm (inch)
• PC Configurator cable (model: MCN-CON or COP-US)
• PC configurator software (model: DLCFG)
• PC configurator software (model: R8CFG)
• Local certification authority creator (model: LCA-DL8)
Software downloadable at M-System’s web site.
• SD card
MODEL: DL8–[1]–R[2]
ORDERING INFORMATION
• Code number: DL8–[1]-R[2]
Specify a code from below for each of [1] and [2].
(e.g. DL8-D-R/Q)
An SD card is necessary to store data.
Use the specified model number of memory card.
Available for purchase from M-System. Consult M-System.
- Hagiwara Solutions NSD6-004GH(B21SEI
(NSD6-004GH(A00SDI, NSDA-004GL ... discontinued)
• Specify the specification for option code /Q
(e.g. /C01)
PACKAGE INCLUDES...
• Protective cover
[1] MODULE TYPE
A: Modbus/TCP (Ethernet) (Server/client)
• Ferrite core
Web server
B: Modbus/TCP (Ethernet) (Server/client)
Web server, reporting by e-mail, FTP client
C: Modbus/TCP (Ethernet) (Server/client)
Web server, reporting by e-mail, FTP server/client, data logger
D: Modbus/TCP (Ethernet) (Server/client)
Web server, reporting by e-mail, FTP server/client, data logger,
I/O mapping, user-defined Web browser view
E: Modbus/TCP (Ethernet) (Server/client)
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 1/9
https://www.m-system.co.jp/
MODEL: DL8
Ethernet indicator LED: DPLX, LNK
GENERAL SPECIFICATIONS
Connection
IP address: 192.168.0.1 (factory setting)
•Power supply (exc. supply), RUN contact output:
Tension clamp terminal (Front Twin connection)
Unit side connector: MSTB2,5/5-GF-5,08AU
Cable side connector: TFKC2,5/5-STF-5,08AU
INSTALLATION
Power consumption
•DC: Approx. 12 W 24 V DC (@ internal power max. current
1.6 A)
(Applicable wire size: 0.2 - 2.5 mm2, stripped length 10
mm)
Internal power supply (power supply for I/O module):
• DC power supply: 5 V DC
Recommended solderless terminal
AI0,25-10YE 0.25 mm (Phoenix Contact)
AI0,34-10TQ 0.34 mm (Phoenix Contact)
AI0,5-10WH 0.5 mm (Phoenix Contact)
AI0,75-10GY 0.75 mm (Phoenix Contact)
AI1-10RD 1.0 mm (Phoenix Contact)
AI1,5-10BK 1.5 mm
AI2,5-10BU 2.5 mm
2
• Current capacity: 1.6 A
2
Excitation supply output (excitation for I/O module)
•DC: 24 V DC ±10 %
2
2
•Operational current: 7 A
2
(From power supply (exitation supply) connector, via
connector for internal bus, supplied to each I/O module.
Power output current consumption must be under
operational current.)
2
(Phoenix Contact)
(Phoenix Contact)
2
•Ethernet: RJ-45 connector
•Internal bus, internal power, exc. supply: Connector
Housing material: Flame-resistant resin (gray)
Max. number of I/O modules: 16
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: DIN rail
(Max. consumption current of I/O modules: 1.6 A)
Isolation: Ethernet to internal bus or internal power or
power supply (exc. supply) to RUN contact output to FE
(No isolation between discrete input/output and power
supply of the I/O modules when used with the DL8.)
Calendar clock: Year (4 digits), month, date, day, hour,
minute, second
Weight: 190 g (0.42 lb)
PERFORMANCE
Battery: Vanadium-lithium secondary battery
(undetachable)
Calendar clock accuracy: Monthly deviation 2 minutes at
25°C
Status indicator LED: POWER, LOGGING, SD CARD, SEND,
COM, ERROR
Battery backup: Approx. 2 months
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute (Ethernet to
internal bus or internal power or power supply (exc. supply)
to RUN contact output to FE)
RUN contact output: Photo MOSFET relay (no polarity);
(OFF in error detected)
•Peak load voltage: 50 V max.
•Continuous load current: 50 mA max.
•Peak load current: 300 mA max. (≤0.1 sec.)
•Operation
Power down: OFF
STANDARDS & APPROVALS
EU conformity:
Firmware operating: ON
Error in Ethernet LNK: OFF
EMC Directive
Internal bus error: OFF
EMI EN 61000-6-4
SD card writing error: OFF
EMS EN 61000-6-2
RoHS Directive
(Run contact output is applicable for Type C with the DL8
firmware version 1.4.x or later.)
ETHERNET COMMUNICATION
Communication Standard: IEEE 802.3u
Transmission: 10BASE-T, 100BASE-TX
Baud rate: 10/100 Mbps (Auto Negotiation function)
Protocol: TCP/IP, Modbus/TCP, SLMP, HTTP, HTTPS, FTP,
FTPS, SMTP, SNTP
Transmission media: 10BASE-T (STP, Category 5), 100BASE-
TX (STP, Category 5e)
Max. length of fieldbus segment: 100 meters
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 2/9
https://www.m-system.co.jp/
MODEL: DL8
COMPATIBLE BROWSING DEVICE
■ Software requirement
Functional checked environment
PC
•OS:
Windows 7 (32-bit/64-bit), Windows 8.1 (32-bit/64-bit)), Windows 10 (32-bit/64-bit)
•Browser:
Internet Explorer 11
Microsoft Edge 89.0
Chrome 89.0
Firefox 81.0
Tablet
•OS:
iPad (iPadOS 14.4); Android terminal (Android 10.0)
•Browser:
iOS: Safari; Android: Chrome
Smart phone
•OS
iPhone (iOS 14.4); Android terminal (Android 10.0)
•Browser:
iOS:Safari; Android: Chrome
BASIC CONFIGURATIONS
The modules' addresses can be set freely from 0 to 31 regardless the mounting location. However, be sure not to use
duplicated addresses. A 4-point analog I/O module occupies 2 addresses. E.g. when R8-SV4N is set to address 5, Input 1 and
Input 2 are assigned to address 5, Input 3 and Input 4 are assigned to address 6. In this case, do not set other I/O modules to
address 6.
■ HOW TO MOUNT THE MODULE ON DIN RAIL
Web-Enabled RTU Modules
• Web-Enabled RTU Modules
I/O Modules
Hook
DIN Rail Adaptor
Protective Cover
Position the upper hook at the rear on the DIN rail and push in the lower.
When removing the module, push down the DIN rail adaptor utilizing a
minus screwdriver and pull.
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 3/9
https://www.m-system.co.jp/
MODEL: DL8
• I/O Module
A
B
Confirm that the locking clamps of the I/O module are set.
Insert the module in parallel to the next one while aligning the grooves of
both modules (A & B in the above figure).
Maintain it perpendicularly to the rail.
More I/O modules can be added in the same manner.
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 4/9
https://www.m-system.co.jp/
MODEL: DL8
EXTERNAL VIEW
Ethernet Indicator LED
Status Indicator LED
Miniature Jack Connector for R8CFG
Internal Bus Connector
POWER
LOGGING
SD CARD
SEND
DPLX
LNK
COM
RJ-45 Connector for Ethernet
ERROR
I/O
LOGGING
SD CARD
Logging Button (Type C, D & E)
SD Button (Type C, D & E)
SD Card Slot (Type C, D & E)
Function Setting DIP SW
8
7
6
5
4
3
2
1
8
7
5
3
1
6
4
2
Connector for Power Supply (Exc. supply),
RUN Contact Output
On
CFG
On
Miniature Jack Connector for DLCFG
■ STATUS INDICATOR LED
LED Color Function
ON at device operating normally
POWER Green Blinking at Ethernet LINK error
Blinking before obtaining DHCP address
LOGGING Green ON at logging (Type C D & E)
,
ON during SD card mounted
SD CARD Green Blinking at reading/writing SD card
(Type C D & E)
,
SEND
COM
Green Blinking at e-mailing
Blinking at communication
Green
(except Modbus/TCP master & SLMP Client)
ON at error
• R8 I/O module reading error
• SD card access error
• SD card insufficient capacity
ERROR
Red
■ ETHERNET INDICATOR LED
LED
DPLX
LNK
Color Function
Amber ON at full duplex
Green ON at link
CONNECTION DIAGRAMS
■ POWER SUPPLY (EXC. SUPPLY), RUN CONTACT OUTPUT CONNECTOR TERMINAL ASSIGNMENT
Printed-circuit board connector (Phoenix Contact)
Unit side connector: MSTBV2,5/5-GF-5,08AU
Cable side connector: TFKC2,5/5-STF-5,08AU
No.
1
ID
24V
0V
FUNCTION
1
2
3
4
5
Power supply (exc. supply) 24 V DC
Power supply (exc. supply) 0 V DC
2
3
RUN RUN contact output
RUN RUN contact output
4
5
FE
Power supply (exc. supply) earth
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 5/9
https://www.m-system.co.jp/
MODEL: DL8
EXTERNAL DIMENSIONS unit: mm [inch]
■UNIT
73 (2.87)
55 (2.17)
50 (1.97)
[3 (.12)]
[4 (.18)]
DIN RAIL
(35 mm wide)
■PROTECTIVE COVER
5 (.20)
50 (1.97)
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 6/9
https://www.m-system.co.jp/
MODEL: DL8
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Note: In order to improve EMC performance, bond the FE terminal to ground.
Caution: FE terminal is NOT a protective conductor terminal.
FUNCTION
SETTING SW
LED
SD CARD SLOT
Isolation
Control
Ciruict
Comm
Circuit
Ethenet
RJ-45 CONNECTOR
INTERNAL BUS
MINIATURE JACK
MINIATURE JACK
DLCFG
R8CFG
+24V
Power Circuit
(non isolated)
INTERNAL POWER (5 V)
EXC. SUPPLY (24 V)
0V
RUN CONTACT RUN
OUTPUT
Isolation
FE
available for the products using 16 bit data (model: R3-PA16
etc.).
COMMUNICATION
IP:
DHCP client is supported. Manual setting of IP address,
subnet mask, default gateway and DNS server available too.
Modbus/TCP slave:
ALARM OUTPUT (Type B, C, D & E)
Event can trigger an alarm contact at a discrete output
module.
Remote observation system via SCADA etc.
Number of connections 4
•Transition of analog input zone
•Transition of pulse input zone
•Status change of discrete input
•Count up of discrete input
Modbus/TCP master:
I/O expansion with remote I/O, e.g. R3 or R7 series, is
available. Measuring points in multiple locations can be
handled collectively.
SLMP Client:
EVENT REPORTING E-MAIL (Type B, C, D & E)
Reporting e-mail function available at event or designated
time.
DL8 allows I/O expansion by connecting with the SLMP-
compatible CPU unit of Mitsubishi programmable-controller
MELSEC; and collectively handles data from measuring
points in multiple locations.
Encrypted communication is supported. (SMTP over SSL).
The DL8 turns a designated Do ON after transmitting the
report.
Web server function (Direct):
This unit can be a Web server, and 'Data,' 'Trend' and 'Event
Log' views are available from remote location.
Web server function (Cloud):
· Number of e-mail attention: 32
· Number of event report text: 32
· Number of regular report text: 1
This unit can be an FTP client, and upload the Web files to a
cloud server.
· Channel status: AI, DI, PI, DO, AO status attachable to e-
mail
Users can browse the cloud server.
(DO and AO are available with firmware version of the unit
1.4.x or later)
Multiple users can access it at once without extra load at
the unit. (only browsing, operation not available.)
Analog input: 32 points
· Output at transmitting failure: 1 point
Discrete input: 64 points
Pulse input: 32 points
LOGGING (Type C, D & E)
Diescrete output: 64 points
Log files in text format are stored into an SD card. The
number of logs depends on the free space of the SD card.
Log file: System log, event log, e-mail report log, channel
Analog output: 32 points (firmware version of the unit: 1.4.x
or later)
* For pulse input, only 32 bit data is available. It is not
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 7/9
https://www.m-system.co.jp/
MODEL: DL8
log
Compatible FTP client
•Explorer
•FFFTP 4.4
FTP CLIENT (Type B, C, D & E)
The recorded data is uploaded to an FTP server and FTPS
server (Type E) in CSV format in specified interval time.
User can define the CSV file.
•Web browser
Internet Explorer version 11
Firefox version 75.0
Compatible FTPS client
•FFFTP 4.4
•Number of channel: Max. 32 (Selectable within AI, DI, DI
(counter), PI, DO, AO)
(AO is selectable with firmware version of the unit 1.4.x or
later)
I/O MAPPING (Type D & E)
Multiplex Data Transmission for remote I/O and IP telemeter
is available by registering DI-to-DO or AI-to-AO mapping
information.
•Sampling rate (Firmware version 1.6.x or later)
1 or 2 sec (Interval time: 1 or 10 min. or 1 hr.)
5, 10 or 30 sec. (Interval time: 10 min. or 1 hr.)
1, 2, 5, 10, 15, 20 or 30 min. (Interval time: 1 day)
•Sampling rate (Firmware version 1.2.x or later)
1 or 2 sec (Interval time: 1 or 10 min. or 1 hr.)
5, 10 or 30 sec. (Interval time: 10 min. or 1 hr.)
1, 2, 5, 10 or 30 min. (Interval time: 1 day)
•Sampling rate (Firmware version 1.1.x or earlier)
1, 2, 5, 10 or 30 sec. (Interval time: 1 hr.)
1, 2, 5, 10 or 30 min. (Interval time: 1 day)
Note: To confirm the firmware version, use the configurator
software, model: DLCFG.
USER DEFINED BROWSER VIEW (Type D & E)
The browser view is user-definable.
Development tools for HTML file are not available by M-
System. Provide by customer.
OTHER FUNCTIONS
Configuration: Configurable with the dedicated software
model: DLCFG
Time zone: Selectable between –12:00 and +13:00
(Time zone setting by minutes is not available for the DL8
Ver.1.3 or earlier versions.)
TREND DATA STORING (Type C, D & E)
The logged data is written into the SD card in CSV format.
User can define the CSV file.
•Number of channels: Max. 32 (Selectable within AI, DI, DI
(counter), PI, DO, AO)
(DO and AO are selectable with firmware version of the unit
1.4.x or later)
•AI sampling: Momentary, average, peak (max.), peak
(min.)
•Logging rate:
Second: 1, 2, 5, 10, 20, 30 sec.
Minute: 1, 2, 5, 10, 15, 20, 30 min.
(15 min. is selectable with firmware version 1.5.x or later)
On the hour: 0 to 23 o’clock (1 or more times available;
specify time delay for each set time)
Day start time and days to log are available.
•Recordable up to the SD card size.
Automatically deleted.
(Auto delete is available with firmware version of the unit
1.4.x or later)
•Recording period (as a guide)
Approx. 180 days
(logging rate: 1 sec, 32 channels, only trend storing)
FTP SERVER (Type C, D & E)
Reading and deleting files in the SD card by an FTP client
and an FTPS client (Type E) are ailable.
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 8/9
https://www.m-system.co.jp/
MODEL: DL8
SYSTEM CONFIGURATION EXAMPLES
Devices other than the DL8 in below provided by the user.
■ Monitoring
(SCADA or web browser)
■ Monitoring
(web browser)
■ Receiving mails
■ Monitoring
(web browser)
PC/SCADA
Smart Phone
Smart Phone
Wi-Fi
Router
3G/LTE Mobile Line
ADSL/Optical
ISP : Internet Service Provider
ISP
ISP
ISP
Web (Internet, VPN, Cloud Server)
ISP
DL8
3G/LTE Mobile Line
ADSL/Optical
I/O
■ Web server
Mobile
Router
ADSL/Optical Modem
Router
Mitsubishi
programmable-controller
MELSEC iQ-R series
Ethernet
Ethernet
RS-485
DL8
I/O
Ethernet/RS-485 Adaptor
(model: GR8-EM)
R3-NE1
Network Module
DL8
53U
Multi Power Monitor
I/O
I/O
■ Web server
■ Web server
■ Sending mails
I/O
ISP: Internet Service Provider
3G (3rd Generation): Third generation of mobile telecommunications technology
LTE (Long-Term Evolution): Enhancement of the third generation
Note: An E-mail account for a mail server is required to use e-mailing function.
Specifications are subject to change without notice.
DL8 SPECIFICATIONS
ES-7691 Rev.18 Page 9/9
https://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明