DAST-20-1SS7 [MSYSTEM]
Telemetering System;型号: | DAST-20-1SS7 |
厂家: | M-SYSTEM |
描述: | Telemetering System |
文件: | 总22页 (文件大小:383K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: DAST-20
4 voltage outputs
Telemetering System
MU4: Analog & pulse outputs
4 voltage outputs
TELEMETERING SYSTEM
Functions & Features
4 pulse outputs (open collector)
MS4: Contact, analog & pulse outputs
2 open collector outputs
4 voltage outputs
• Small-scale telemetering system
• Lightning arrester protecting telephone circuit standard
• Approved of Technical Requirements Compliance Approval
by Japan Approvals Institute for Telecommunications
Equipment
2 pulse outputs (open collector)
Local Station
SA41: Contact inputs, 4 dry contact inputs
SE5: Contact I/O, 4 dry contact inputs
4 open collector outputs
SG4: Analog inputs, 4 voltage inputs
SR3: Analog I/O, 4 voltage inputs
4 voltage outputs
• Isolation between telephone circuit, I/O and power
• Easy-to-handle plugin construction for each component:
Communication Module, Modem Module, Lightning Arrester
• Self-diagnosis
• Monitor LED provided for contact I/O modules
SS5: Contact & analog inputs
4 dry contact inputs
180 (7.09)
4 voltage inputs
SS7: Contact outputs & analog inputs
4 open collector outputs
4 voltage inputs
160
SP4: Analog & pulse inputs
4 voltage inputs
(6.30)
4 dry contact pulse inputs
SS3: Contact, analog & pulse inputs
2 dry contact inputs
mm (inch)
4 voltage outputs
2 dry contact pulse inputs
MODEL: DAST-20-[1][2]-K
POWER INPUT
AC Power
ORDERING INFORMATION
• Code number: DAST-20–[1][2]–K
Specify a code from below for each of [1] and [2].
(e.g. DAST-20-1MC81-K)
K: 85 – 132 V AC
(Operational voltage range 85 – 132 V, 47 – 66 Hz)
APPLICATION TO NTT
[1] TRANSMISSION RATE
Application form is available at local NTT sales offices.
“Guide for Application for Dedicated Circuit Lease” is
provided for free for detailed explanation.
1: 50 bps
2: 300 bps
[2] I/O SECTION
Master Station
COMMON SPECIFICATIONS
Construction: lightning arrester, modem and I/O modules
mounted on a chassis for surface mounting
Connection
MC81: Contact outputs, 4 open collector outputs
ME5: Contact I/O, 4 dry contact inputs
4 open collector outputs
• Telephone circuit: M4 screw terminals (torque 0.8 N·m)
• Power & I/O: M3.5 screw terminals (torque 0.8 N·m)
• RUN contact output: Euro type connector terminal
MM4; Analog outputs, 4 voltage outputs
MR3: Analog I/O, 4 voltage inputs
4 voltage outputs
(Applicable wire size: ≤ 1.25 mm , stripped length 8 mm)
2
MS6; Contact & analog outputs
4 open collector outputs
• Grounding: M4 screw terminal (torque 0.8 N·m)
Screw terminal
4 voltage outputs
• Telephone circuit & grounding: Nickel-plated steel
• Power & I/O: Chromated steel
MS8; Contact inputs & analog outputs
4 dry contact inputs
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 1/22
http://www.m-system.co.jp/
MODEL: DAST-20
Material
Between lines: ±1.2 V min.
Chassis: black chromate-plated steel
Housing: flame-resistant resin (black)
Isolation: telephone circuit to I/O to power
Self-diagnosis
Line to ground: ±500 V max.
Maximum surge voltage
Between lines: ±15 V max.
Line to ground: ±650 V max.
CPU: watch-dog timer
Response time: ≤0.1 μsec.
Memory: sum check
Discharge current capacity: 5000 A (8 / 20 msec.)
Maximum load current: 100mA
Internal series resistance: approx. 8 Ω including return
Leakage current
Power voltage: detects when the voltage supply to the CPU
drops by 10 %.
■ RUN CONTACT OUTPUT
RUN contact output: contact opens when the self-diagnosis
detects an abnormality or with a transmission error.
Rating: 120V AC or 30V DC @1A (resistive load)
Between lines: ≤20 mA at ±1.2 V
Line to ground: ≤10 mA at ±140 V
Maximum line voltage: 1.2 V
MODEM & LIGHTNING ARRESTER
■ 50 BPS TYPE
INSTALLATION
Power consumption
•Modem (model: MOD1-K)
•AC: Approx. 5 VA max.
Telephone circuit: NTT leased circuit, 50 bps
Sending voltage: ±50 V max.
Sending current: ±20 mA ±3 mA
Transmission method: earth-return
Transmission rate: 50 bps
Grounding: ≤100 Ω required for 50 bps type
Operating temperature: -5 to + 50°C (23 to 122°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Surface
No. of circuits: 1
Weight: 1.5 kg (3.3 lb)
Approval No.: L02-0066
•Lightning Arrester (model: MDP-MFA)
Discharge voltage
PERFORMANCE
Permissible power failure duration: ≤ 20 ms
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute
(telephone circuit to I/O to power)
Between B – C: ±110 V min.
Between B or C – A: ±55 V min.
Between each line – G: ±500 V max.
Maximum surge voltage
1500 V AC @1 minute (circuit to ground)
Between 2 – 3: ±320 V max.
Between 2 or 3 – 1: ±160 V max.
Between each line – G: ±650 V max.
Response time: ≤0.1 μsec.
TRANSMISSION TIME
■ Simple Transmission Time
The simple transmission time means the time between the
start of data sending from the master station and the end of
data sending from the local station. It means 1 cycle of data
transmission between the master station
and the local station. It does not mean the time required for
an input signal to be output.
Discharge current capacity: 5000 A (8 / 20 msec.)
Maximum load current: 100 mA
Internal series resistance: approx. 20 Ω including return
Leakage current
Between B – C: ≤50 mA at ±110 V DC
Between B or C – A: ≤50 mA at ±55 V DC
Between each line – G: ≤10 mA at ±140 V DC
■ 300 BPS TYPE
■ How to Calculate the Simple Transmission Time
•Transmission Rate 50 bps
Simple Transmission Time (sec.)
•Modem (model: MOD2-K)
= (No. of data bytes from master station + No. of data
bytes from local station) × 0.22 + 0.5 × 2
•Transmission Rate 300 bps
Telephone circuit: NTT leased circuit, 3.4 kHz
Sending level: -7 to -15 dBm
Receiving level: -40 dBm
Simple Transmission Time (sec.)
Transmission rate: 300 bps (half-duplex)
Modulation: conform to ITU-T V.21
No. of circuits: 1
= (No. of data bytes from master station + No. of
data bytes from local station) × 0.037 + 0.2 × 2
■ Effective Transmission Time
Approval No.: D01-0730JP
The effective transmission time means the time required for
a change of an input signal to affect its output signal. It
•Lightning Arrester (model: MDP-FT)
Discharge voltage
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 2/22
http://www.m-system.co.jp/
MODEL: DAST-20
varies between the minimum and maximum values,
depending upon the timing of input change.
Minimum Time = Simple Transmission Time
Maximum Time = Simple Transmission Time × 2
MOUNTING REQUIREMENTS unit: mm (inch)
4–M4 SCREW
100 (3.94)
FRONT PANEL CONFIGURATION & TERMINAL ASSIGNMENT
■ 50 bps TYPE (Transmission Rate Code: 1)
No. DESCRIPTION
EXPLANATION
Red LED ON at normal status;
Lightning Arrester
Modem
I/O Module
1
RUN LED
4
5
6
OFF at anomaly detected by selfdiagnosis;
blinks when there is anomaly in telephone
circuit.
1
2
3
4
5
6
Contact I/O
Red LED ON with contact ON;
Monitor LEDs
provided only for contact I/O types
OFF
ON
T1
T2
T3
T4
SG
RD
SD
RUN Contact
Relay opens when an anomaly is detected.
2
3
Output Terminals
1
2
10
11
Power Indicator
LED
Red LED ON at normal status;
OFF when the voltage level drops.
SD RD FG
LINE
U V
POWER
Circuit Test SW
Normally OFF;
turned ON when testing only.
7
8
9
Circuit Status
Red LED; SD blinks during sending;
RD blinks during receiving.
Indicator LEDs
7
8
Power Terminals
Refer to the Terminal Connection.
6
5
4
3
7
14
6
5
12
4
3
SG, RD, SD
Terminals
Connected with the lightning arrester.
(factory connected)
3
2
1
9
Circuit Test
Normally shorted with a jumper.
Circuit connection is broken when it is
removed (opened).
Terminals
8
9
C
B
A
(T1 – T2, T3 – T4)
7
8
1
2
15 10
1
11
2
10 Circuit Connection Refer to the Terminal Connection.
Terminals
11 Grounding Terminal Refer to the Terminal Connection.
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 3/22
http://www.m-system.co.jp/
MODEL: DAST-20
■ 300 bps TYPE (Transmission Rate Code: 2)
No. DESCRIPTION
EXPLANATION
Lightning Arrester
Modem
I/O Module
1
RUN LED
Red LED ON at normal status;
OFF at anomaly detected by selfdiagnosis;
blinks when there is anomaly in telephone
circuit.
4
6
5
1
2
3
4
5
6
Contact I/O
Red LED ON with contact ON;
Monitor LEDs
provided only for contact I/O types
RUN Contact
Relay opens when an anomaly is detected.
2
3
Output Terminals
1
2
9
Power Indicator
LED
Red LED ON at normal status;
OFF when the voltage level drops.
SD RD FG
LINE
U V
POWER
10
Master/Local SW
Designating the Master and Local Stations
(factory set)
7
8
11
Circuit Status
Red LED; turn ON according to the status
of telephone circuit
Indicator LEDs
7
8
Power Terminals
Refer to the Terminal Connection.
6
5
4
3
7
14
6
5
12
4
3
Modem Circuit
Terminals
Connected with the lightning arrester.
(factory connected)
P
S
P
S
9
Circuit Connection Refer to the Terminal Connection.
Terminals
8
9
7
8
1
2
15 10
1
11
2
10 Grounding Terminal Refer to the Terminal Connection.
11 Modem Circuit
Connector
Not used.
CONNECTION DIAGRAM
■ 50 bps TYPE (Transmission Rate Code: 1)
■ 300 bps TYPE (Transmission Rate Code: 2)
FG
RD
SD
L1
L2
A
B
C
1
2
3
S
S
P
P
LIGHTNING
ARRESTER
TELEPHONE
CIRCUIT
LIGHTNING
ARRESTER
TELEPHONE
CIRCUIT
U
7
8
LINE 1
LINE 2
POWER
MODEM
U
V
7
8
SG
RD
SD
POWER
V
MODEM
7
I/O MODULE
Refer to later pages
14 for connection of
each I/O type.
7
I/O MODULE
Refer to later pages
1
2
RUN CONTACT
14 for connection of
each I/O type.
1
2
RUN CONTACT
8
G
8
G
100 ohms max.
Remark 1 : Broken line connections are already done at factory. Do not remove those cables already wired
when wiring to power supply (Terminals 7 – 8 of the Modem) and ground terminals (G).
Remark 2 : Be sure to ground (100 ohms or less) for 50 bps type which emploies the earth-return method.
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 4/22
http://www.m-system.co.jp/
MODEL: DAST-20
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
10 (.39)
100 (3.94)
180 (7.09)
70 (2.76) min.
156 (6.14)
Shape of the lightning arrester changes according to model No.
• Wiring Procedure of DIN Terminals
PIN TERMINAL
PHOENIX AI1.5-8BK RECOMMENDED
MULTI-STRAND CABLE: 1.25 mm2
SCREWDRIVER (–)
SOLID CABLE
1.4 dia.
Remove cover.
8 mm
SYSTEM DESCRIPTIONS
DAST-20 Master Station
DAST-20 Local Station
Leased
Telephone
Circuit
Lightning Arrester
for Power Supply
(model: MA-100)
Lightning Arrester
for Power Supply
(model: MA-100)
Power Source
Power Source
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 5/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER,CONTACT OUTPUT
MODEL: DAST–20–[1]MC81-K
ORDERING INFORMATION
• Code number: DAST-20–[1]MC81–K
Specify a code from below for [1].
(e.g. DAST-20-1MC81-K)
[1] TRANSMISSION RATE
1: 50 bps
2: 300 bps
POWER INPUT
AC Power
K: 85 – 132 V AC
OUTPUT SPECIFICATIONS
■ OPEN COLLECTOR OUTPUT
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
PERFORMANCE
Number of data bytes: 10
OUTPUT TERMINAL CONNECTION
5
Do 1
3
4
6
7
8
Do 2
Do 3
5
Do 4
6
COM. (–)
12
9
10
1
2
15
11
Base Socket
Italic numbers indicate LED No. on the front panel.
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 6/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, CONTACT INPUT
MODEL: DAST–20–[1]SA41-K
ORDERING INFORMATION
• Code number: DAST-20–[1]SA41–K
Specify a code from below for [1].
(e.g. DAST-20-1SA41-K)
[1] TRANSMISSION RATE
1: 50 bps
2: 300 bps
POWER INPUT
AC Power
K: 85 – 132 V AC
INPUT SPECIFICATIONS
■ DRY CONTACT INPUT
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
PERFORMANCE
Number of data bytes: 14
INPUT TERMINAL CONNECTION
5V
1
Di 1
3
4
2
3
4
Di 2
Di 3
5
Di 4
6
COM. (–)
12
9
10
15
1
2
11
Base Socket
Italic numbers indicate LED No. on the front panel.
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 7/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER,CONTACT I/O
I/O TERMINAL CONNECTION
MODEL: DAST–20–[1]ME5-K
5V
1
2
3
4
Di 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]ME5–K
Specify a code from below for [1].
(e.g. DAST-20-1ME5-K)
Di 2
Di 3
5
Di 4
6
COM. (–)
Do 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Do 2
10
1
2: 300 bps
Do 3
POWER INPUT
AC Power
Do 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
INPUT SPECIFICATIONS
■ DRY CONTACT INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
OUTPUT SPECIFICATIONS
■ OPEN COLLECTOR OUTPUT
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
PERFORMANCE
Number of data bytes: 14
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 8/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, CONTACT I/O
I/O TERMINAL CONNECTION
MODEL: DAST–20–[1]SE5-K
5V
1
2
3
4
Di 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]SE5–K
Specify a code from below for [1].
(e.g. DAST-20-1SE5-K)
Di 2
Di 3
5
Di 4
6
COM. (–)
Do 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Do 2
10
1
2: 300 bps
Do 3
POWER INPUT
AC Power
Do 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
INPUT SPECIFICATIONS
■ DRY CONTACT INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
OUTPUT SPECIFICATIONS
■ OPEN COLLECTOR OUTPUT
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
PERFORMANCE
Number of data bytes: 14
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 9/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, ANALOG OUTPUTS
MODEL: DAST–20–[1]MM4-K
ORDERING INFORMATION
• Code number: DAST-20–[1]MM4–K
Specify a code from below for [1].
(e.g. DAST-20-1MM4-K)
[1] TRANSMISSION RATE
1: 50 bps
2: 300 bps
POWER INPUT
AC Power
K: 85 – 132 V AC
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 10
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
OUTPUT TERMINAL CONNECTION
Ao 1
3
4
Ao 2
Ao 3
5
Ao 4
6
COM. (–)
12
9
10
1
2
15
11
Base Socket
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 10/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, ANALOG INPUTS
MODEL: DAST–20–[1]SG4-K
ORDERING INFORMATION
• Code number: DAST-20–[1]SG4–K
Specify a code from below for [1].
(e.g. DAST-20-1SG4-K)
[1] TRANSMISSION RATE
1: 50 bps
2: 300 bps
POWER INPUT
AC Power
K: 85 – 132 V AC
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 28
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
INPUT TERMINAL CONNECTION
Ai 1
3
4
Ai 2
Ai 3
5
Ai 4
6
COM. (–)
12
9
10
1
2
15
11
Base Socket
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 11/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, ANALOG I/O
I/O TERMINAL CONNECTION
MODEL: DAST–20–[1]MR3-K
Ai 1
3
4
Ai 2
ORDERING INFORMATION
• Code number: DAST-20–[1]MR3–K
Specify a code from below for [1].
(e.g. DAST-20-1MR3-K)
Ai 3
5
Ai 4
6
COM. (–)
Ao 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
Ao 2
10
1
Ao 3
2: 300 bps
Ao 4
2
POWER INPUT
AC Power
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 28
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 12/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, ANALOG I/O
I/O TERMINAL CONNECTION
MODEL: DAST–20–[1]SR3-K
Ai 1
3
4
Ai 2
ORDERING INFORMATION
• Code number: DAST-20–[1]SR3–K
Specify a code from below for [1].
(e.g. DAST-20-1SR3-K)
Ai 3
5
Ai 4
6
COM. (–)
Ao 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
Ao 2
10
1
Ao 3
2: 300 bps
Ao 4
2
POWER INPUT
AC Power
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 28
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 13/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, CONTACT & ANALOG OUTPUTS
MODEL: DAST–20–[1]MS6-K
OUTPUT TERMINAL CONNECTION
Ao 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]MS6–K
Specify a code from below for [1].
(e.g. DAST-20-1MS6-K)
Ao 2
Ao 3
5
Ao 4
6
COM. (–)
Do 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Do 2
10
1
2: 300 bps
Do 3
POWER INPUT
AC Power
Do 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
■ OPEN COLLECTOR OUTPUT
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 10
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 14/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, CONTACT & ANALOG INPUTS
MODEL: DAST–20–[1]SS5-K
INPUT TERMINAL CONNECTION
Ai 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]SS5–K
Specify a code from below for [1].
(e.g. DAST-20-1SS5-K)
Ai 2
Ai 3
5
Ai 4
6
COM. (–)
12
11
9
[1] TRANSMISSION RATE
5V
1: 50 bps
1
2
3
4
Di 1
2: 300 bps
Di 2
10
1
POWER INPUT
AC Power
Di 3
Di 4
2
K: 85 – 132 V AC
COM. (–)
15
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
■ DRY CONTACT INPUT
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 30
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 15/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, CONTACT INPUTS & ANALOG OUTPUTS
OUTPUT TERMINAL CONNECTION
MODEL: DAST–20–[1]MS8-K
Ao 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]MS8–K
Specify a code from below for [1].
(e.g. DAST-20-1MS8-K)
Ao 2
Ao 3
5
Ao 4
6
COM. (–)
12
11
9
[1] TRANSMISSION RATE
5V
1: 50 bps
1
2
3
4
Di 1
2: 300 bps
Di 2
10
1
POWER INPUT
AC Power
Di 3
Di 4
2
K: 85 – 132 V AC
COM. (–)
15
Base Socket
INPUT SPECIFICATIONS
■ DRY CONTACT INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 14
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 16/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, CONTACT OUTPUTS & ANALOG INPUTS
INPUT TERMINAL CONNECTION
MODEL: DAST–20–[1]SS7-K
Ai 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]SS7–K
Specify a code from below for [1].
(e.g. DAST-20-1SS7-K)
Ai 2
Ai 3
5
Ai 4
6
COM. (–)
Do 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Do 2
10
1
2: 300 bps
Do 3
POWER INPUT
AC Power
Do 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
OUTPUT SPECIFICATIONS
■ OPEN COLLECTOR OUTPUT
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 28
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 17/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, ANALOG & PULSE OUTPUTS
MODEL: DAST–20–[1]MU4-K
OUTPUT TERMINAL CONNECTION
Ao 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]MU4–K
Specify a code from below for [1].
(e.g. DAST-20-1MU4-K)
Ao 2
Ao 3
5
Ao 4
6
COM. (–)
Po 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Po 2
10
1
2: 300 bps
Po 3
POWER INPUT
AC Power
Po 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
■ PULSE OUTPUT (open collector)
Capacity: 4 points
Commons: per 4 points
Rating: 30 V DC @100 mA
Frequency: 10 Hz max.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 10
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 18/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, ANALOG & PULSE INPUTS
MODEL: DAST–20–[1]SP4-K
INPUT TERMINAL CONNECTION
Ai 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]SP4–K
Specify a code from below for [1].
(e.g. DAST-20-1SP4-K)
Ai 2
Ai 3
5
Ai 4
6
COM. (–)
12
11
9
[1] TRANSMISSION RATE
5V
1: 50 bps
1
2
3
4
Pi 1
2: 300 bps
Pi 2
10
1
POWER INPUT
AC Power
Pi 3
Pi 4
2
K: 85 – 132 V AC
COM. (–)
15
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
■ PULSE INPUT
Capacity: 4 points
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
Frequency: 10 Hz max.
Pulse width time requirement: ≥ 45 msec. for ON and OFF
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 44
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 19/22
http://www.m-system.co.jp/
MODEL: DAST-20
MASTER, CONTACT, ANALOG & PULSE OUTPUTS
OUTPUT TERMINAL CONNECTION
MODEL: DAST–20–[1]MS4-K
Ao 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]MS4–K
Specify a code from below for [1].
(e.g. DAST-20-1MS4-K)
Ao 2
Ao 3
5
Ao 4
6
COM. (–)
Po 1
12
9
[1] TRANSMISSION RATE
1: 50 bps
5
6
7
8
Po 2
10
1
2: 300 bps
Do 3
POWER INPUT
AC Power
Do 4
2
COM. (–)
15
11
K: 85 – 132 V AC
Base Socket
OUTPUT SPECIFICATIONS
■ VOLTAGE OUTPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Load resistance: 10 kΩ min.
■ OPEN COLLECTOR & PULSE OUTPUT
Capacity: 2 points each
Commons: per 4 points
Rating: 30 V DC @100 mA
Pulse output frequency: 10 Hz max.
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 28
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 20/22
http://www.m-system.co.jp/
MODEL: DAST-20
LOCAL, CONTACT, ANALOG & PULSE INPUTS
MODEL: DAST–20–[1]SS3-K
INPUT TERMINAL CONNECTION
Ai 1
3
4
ORDERING INFORMATION
• Code number: DAST-20–[1]SS3–K
Specify a code from below for [1].
(e.g. DAST-20-1SS3-K)
Ai 2
Ai 3
5
Ai 4
6
COM. (–)
12
11
9
[1] TRANSMISSION RATE
5V
1: 50 bps
1
2
3
4
Pi 1
2: 300 bps
Pi 2
10
1
POWER INPUT
AC Power
Di 3
Di 4
2
K: 85 – 132 V AC
COM. (–)
15
Base Socket
INPUT SPECIFICATIONS
■ VOLTAGE INPUT
Italic numbers indicate LED No. on the front panel.
Capacity: 4 points
Commons: per 4 points
Range: 1 – 5 V DC (operational range 0.5 – 5.5 V)
Input resistance: 1 MΩ min. (500 kΩ min.)
■ DRY CONTACT & PULSE INPUT
Capacity: 2 points each
Commons: per 4 points
Contact detecting voltage: 5 V DC
ON current/resistance: ≥ 1 mA / ≤ 200 Ω
OFF current/resistance: ≤ 50 μA / ≥ 100 kΩ
Pulse output frequency: 10 Hz max., pulse width time
requirement 45 msec. min. for ON and OFF
PERFORMANCE
Accuracy: ±0.2 %
Number of data bytes: 38
Temp. coefficient: ±0.02 %/°C (±0.01 %/°F)
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 21/22
http://www.m-system.co.jp/
MODEL: DAST-20
Specifications are subject to change without notice.
DAST-20 SPECIFICATIONS
ES-5921 Rev.8 Page 22/22
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明