ALV-D44-S/Q [MSYSTEM]

Limit Alarms (rotary switch adj.) AL-UNIT;
ALV-D44-S/Q
型号: ALV-D44-S/Q
厂家: M-SYSTEM    M-SYSTEM
描述:

Limit Alarms (rotary switch adj.) AL-UNIT

文件: 总4页 (文件大小:135K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: ALV  
K: 0 – 100 μA DC (Input resistance 1000 Ω)  
Limit Alarms (rotary switch adj.) AL-UNIT  
GW: -1 – +1 mA DC (Input resistance 1000 Ω)  
FW: -10 – +10 mA DC (Input resistance 100 Ω)  
Z: Specify current (See INPUT SPECIFICATIONS)  
Voltage  
DC ALARM  
Functions & Features  
• Providing SPDT relay outputs at preset DC input levels  
• Dual (Hi/Lo) trip  
1: 0 – 10 mV DC (Input resistance 10 kΩ min.)  
15: 0 – 50 mV DC (Input resistance 10 kΩ min.)  
16: 0 – 60 mV DC (Input resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Input resistance 100 kΩ min.)  
3: 0 – 1 V DC (Input resistance 1 MΩ min.)  
4: 0 – 10 V DC (Input resistance 1 MΩ min.)  
5: 0 – 5 V DC (Input resistance 1 MΩ min.)  
6: 1 – 5 V DC (Input resistance 1 MΩ min.)  
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)  
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)  
0: Specify voltage (See INPUT SPECIFICATIONS)  
• Energized or de-energized coil at a tripped condition  
selectable  
• Rotary switch setpoint adjustments  
• Enclosed relays  
• Relays can be powered 110 V DC  
• Isolation up to 2000 V AC  
• High-density mounting  
Typical Applications  
• Annunciator  
• Various alarm applications  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
50  
(1.97)  
80  
(3.15)  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
132  
(5.20)  
mm (inch)  
MODEL: ALV-[1][2][3]-[4][5]  
[4] POWER INPUT  
AC Power  
ORDERING INFORMATION  
• Code number: ALV-[1][2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. ALV-A13-B/Q)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Special input range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
DC Power  
[1] INPUT  
S: 12 V DC  
Current  
R: 24 V DC  
A: 4 – 20 mA DC (Input resistance 250 Ω)  
A1: 4 – 20 mA DC (Input resistance 50 Ω)  
B: 2 – 10 mA DC (Input resistance 500 Ω)  
C: 1 – 5 mA DC (Input resistance 1000 Ω)  
D: 0 – 20 mA DC (Input resistance 50 Ω)  
E: 0 – 16 mA DC (Input resistance 62.5 Ω)  
F: 0 – 10 mA DC (Input resistance 100 Ω)  
G: 0 – 1 mA DC (Input resistance 1000 Ω)  
H: 10 – 50 mA DC (Input resistance 100 Ω)  
J: 0 – 10 μA DC (Input resistance 1000 Ω)  
V: 48 V DC  
P: 110 V DC  
ALV SPECIFICATIONS  
ES-2717 Rev.8 Page 1/4  
http://www.m-system.co.jp/  
MODEL: ALV  
[5] OPTIONS  
Alarm Trip Operation Terminal No. in parentheses  
blank: none  
(9-11)ON  
/Q: With options (specify the specification)  
Output 1  
Output 2  
(9-10)ON  
(1-3)ON  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
(1-2)ON  
Input  
(%)  
0
50  
100  
/C02: Polyurethane coating  
Output 2  
Setpoint  
Output 1  
Setpoint  
/C03: Rubber coating  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
Trip Operation in Power Failure  
Output Code: 1 & 4: Terminals 1 – 2, 9 – 10 turn ON  
Output Code: 2 & 3: Terminals 1 – 3, 9 – 11 turn ON  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
INSTALLATION  
Power input  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
AC: Operational voltage range: rating ±10 %,  
50/60 ±2 Hz, approx. 2 VA  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Setpoint adjustments: 10-position rotary switches (front); 0  
– 99 % independently; 1 % increments  
Hysteresis (deadband): 0.7 – 2.5 %  
DC: Operational voltage range: rating ±10 %, or 85 – 150  
V for 110 V rating (ripple 10 % p-p max.)  
approx. 2 W (80 mA at 24 V)  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Front LEDs: Red LED turns on when the coil is energized.  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
Weight: 370 g (0.82 lb)  
PERFORMANCE in percentage of span  
Setpoint accuracy: ±0.5 %  
INPUT SPECIFICATIONS  
DC Current:  
Trip point repeatability: ±0.05 %  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 10 mV  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
Response time: Approx. 0.5 sec. (0 – 100 % at 90 %  
setpoint)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output 1  
to output 2 to power to ground)  
Offset: Max. 1.5 times span  
Input resistance  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
OUTPUT SPECIFICATIONS  
Relay Contact: 100 V AC @ 1 A (cos ø = 1)  
120 V AC @ 1 A (cos ø = 1)  
240 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 1 A (resistive load)  
Maximum switching voltage: 380 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @ 10 mA  
Mechanical life: 5 x 10 cycles  
7
For maximum relay life with inductive loads, external  
protection is recommended.  
ALV SPECIFICATIONS  
ES-2717 Rev.8 Page 2/4  
http://www.m-system.co.jp/  
MODEL: ALV  
EXTERNAL VIEW  
No.1 LED  
No.1 Setpoint Rotary SW (x10%)  
No.1 Setpoint Rotary SW (x1%)  
No.2 Setpoint Rotary SW (x10%)  
No.2 Setpoint Rotary SW (x1%)  
No.2 LED  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
8
7
6
5
4
2
4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
9
3
2
10 11  
1
11  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
132 (5.20)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
INPUT RESISTOR  
(model: REM)  
8
7
6
5
4
9
3
2
10 11  
1
Input shunt resistor attached  
for current input.  
ALV SPECIFICATIONS  
ES-2717 Rev.8 Page 3/4  
http://www.m-system.co.jp/  
MODEL: ALV  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
Relay Protection  
• AC Powered  
Inductive  
Load (Coil)  
D / A  
Converter  
ROTARY  
SWITCH  
Varistor or Spark  
Quenching Circuit  
**  
11  
10  
9
LOAD  
H
Low Drift  
Amplifier  
+
5
6
4
Comparator  
Comparator  
Ry  
Ry  
SETPOINT 1  
OUTPUT  
*
U
L
INPUT  
R
• DC Powered  
Inductive  
Load (Coil)  
C
**  
Diode, Varistor or  
CR Circuit  
3
H
LOAD  
SETPOINT 2  
OUTPUT  
2
L
D / A  
Converter  
ROTARY  
SWITCH  
1
C
7
U(+)  
V(–)  
POWER  
8
Base Socket  
* Input shunt resistor attached for current input.  
**Relay status for output codes “1” & “4”, at power OFF.  
Specifications are subject to change without notice.  
ALV SPECIFICATIONS  
ES-2717 Rev.8 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

ALV-D44-V

Limit Alarms (rotary switch adj.) AL-UNIT
MSYSTEM

ALV-D44-V/Q

Limit Alarms (rotary switch adj.) AL-UNIT
MSYSTEM

ALV0020G

Optoelectronic
ETC

ALV0020GC

Optoelectronic
ETC

ALV0020O

Optoelectronic
ETC

ALV0020OC

Optoelectronic
ETC

ALV0020R

Optoelectronic
ETC

ALV0020RC

Optoelectronic
ETC

ALV0020Y

Optoelectronic
ETC

ALV0020YC

Optoelectronic
ETC

ALV0021G

Optoelectronic
ETC

ALV0021GC

Optoelectronic