ACTA-544-V [MSYSTEM]

Limit Alarms (potentiometer adj.) A-UNIT;
ACTA-544-V
型号: ACTA-544-V
厂家: M-SYSTEM    M-SYSTEM
描述:

Limit Alarms (potentiometer adj.) A-UNIT

文件: 总4页 (文件大小:132K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: ACTA  
Limit Alarms (potentiometer adj.) A-UNIT  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
CT ALARM  
(Average sensing, RMS calibrated)  
Functions & Features  
• Providing SPDT relay outputs at preset AC current levels  
from a CT  
[4] POWER INPUT  
AC Power  
• Dual (Hi/Lo) trip  
• CT Protector provided for opencircuit protection  
• Energized or de-energized coil at a tripped condition  
selectable  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
• Hysteresis (deadband) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
DC Power  
Typical Applications  
• Annunciator  
S: 12 V DC  
R: 24 V DC  
• Various alarm applications  
V: 48 V DC  
P: 110 V DC  
50  
(1.97)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
80  
(3.15)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output 1 to output 2 to power  
Input waveform: Sine wave  
132  
(5.20)  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Setpoint adjustments: 270°-turn screwdriver adjustments  
(front); 0 – 100 % independently  
mm (inch)  
Hysteresis (deadband) adjustments: 1 – 100 % (front)  
Front LEDs: LED turns on at a tripped condition; red for  
output 1, green for output 2  
MODEL: ACTA-[1]1[2][3]-[4]  
ORDERING INFORMATION  
• Code number: ACTA-[1]1[2][3]-[4]  
Specify a code from below for each of [1] through [4].  
(e.g. ACTA-1111-B)  
Power ON timer: Relays de-energized for approx. 2 seconds  
after power is turned on.  
INPUT SPECIFICATIONS  
Frequency: 50 or 60 Hz  
[1] INPUT  
Current  
Input burden: 0.5 VA maximum  
Overload capacity: 500 % of rating for 5 sec., 120 %  
continuous  
1: 0 – 1 A AC  
5: 0 – 5 A AC  
Operational range: 0 – 100 % of rating  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
OUTPUT SPECIFICATIONS  
Relay Contact: 100 V AC @ 1 A (cos ø = 1)  
120 V AC @ 1 A (cos ø = 1)  
240 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 1 A (resistive load)  
Maximum switching voltage: 380 V AC or 125 V DC  
ACTA SPECIFICATIONS  
ES-2137 Rev.7 Page 1/4  
http://www.m-system.co.jp/  
MODEL: ACTA  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @ 10 mA  
Mechanical life: 5 x 10 cycles  
7
For maximum relay life with inductive loads, external  
protection is recommended.  
Alarm Trip Operation Terminal No. in parentheses  
(9-11)ON  
Output 1  
(9-10)ON  
(1-3)ON  
Output 2  
(1-2)ON  
Input  
(%)  
0
50  
100  
Output 2  
Setpoint  
Output 1  
Setpoint  
Trip Operation in Power Failure  
Output Code: 1 & 4: Terminals 1 – 2, 9 – 10 turn ON  
Output Code: 2 & 3: Terminals 1 – 3, 9 – 11 turn ON  
INSTALLATION  
Power input  
AC: Operational voltage range: rating ±10 %,  
50/60 ±2 Hz, approx. 2 VA  
DC: Operational voltage range: rating ±10 %, or 85 – 150  
V for 110 V rating (ripple 10 % p-p max.)  
approx. 2 W (80 mA at 24 V)  
Operating temperature: -5 to +60°C (23 to 140°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 450 g (0.99 lb)  
PERFORMANCE in percentage of span  
Trip point repeatability: ±0.5 %  
Temp. coefficient: ±0.05 %/°C (±0.03 %/°F)  
Response time: ≤ 0.7 sec. (0 – 100 % at 90 % setpoint)  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output 1  
to output 2 to power to ground)  
EXTERNAL VIEW  
No.1 Setpoint Adj.  
Span Adj.  
No.1 LED  
Zero Adj.  
No.1 Deadband (Hysteresis) Adj.  
No.2 Deadband (Hysteresis) Adj.  
No.2 LED  
No.2 Setpoint Adj.  
ACTA SPECIFICATIONS  
ES-2137 Rev.7 Page 2/4  
http://www.m-system.co.jp/  
MODEL: ACTA  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
8
9
7
6
5
4
2
4.5 (.18) dia.  
MTG HOLE  
25 (.98) deep  
3
2
10 11  
1
11  
M3.5  
SCREW  
50 (1.97)  
103 (4.06)  
132 (5.20)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
CT PROTECTOR  
(model: CTM)  
8
9
7
6
5
4
3
2
10 11  
1
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
HYSTERESIS  
SETPOINT (DEADBAND)  
SOURCE  
*
INPUT  
TRANS-  
FORMER  
Z
S
11  
10  
9
H
K
k
Average  
Operation  
5
6
4
Comparator  
Ry  
SETPOINT 1  
OUTPUT  
Low Drift  
Amplifier  
L
CT  
C
l
L
*
3
H
LOAD  
Comparator  
Ry  
SETPOINT 2  
OUTPUT  
2
L
CT PROTECTOR  
model: CTM  
1
C
SETPOINT  
HYSTERESIS  
(DEADBAND)  
7
U(+)  
V(–)  
POWER  
8
Base Socket  
*Relay status for output codes “1” & “4”, at power OFF.  
Relay Protection  
• AC Powered  
• DC Powered  
Inductive  
Load (Coil)  
Inductive  
Load (Coil)  
Diode, Varistor or  
CR Circuit  
Varistor or Spark  
Quenching Circuit  
LOAD  
LOAD  
U
ACTA SPECIFICATIONS  
ES-2137 Rev.7 Page 3/4  
http://www.m-system.co.jp/  
MODEL: ACTA  
Specifications are subject to change without notice.  
ACTA SPECIFICATIONS  
ES-2137 Rev.7 Page 4/4  
http://www.m-system.co.jp/  

相关型号:

ACTA22M02A

Board Connector, 10 Contact(s), Male, Right Angle, Solder Terminal, ROHS COMPLIANT
WINCHESTER

ACTA22M02B

Board Connector, 10 Contact(s), Male, Right Angle, Solder Terminal, ROHS COMPLIANT
WINCHESTER

ACTB3R2

Electromechanical Relay, SPDT, 20A (Contact), 14VDC (Contact), Random, DC Output
PANASONIC

ACTB5R2

Electromechanical Relay, SPDT, 20A (Contact), 14VDC (Contact), Random, DC Output
PANASONIC

ACTB5R3

Electromechanical Relay, SPDT, 20A (Contact), 14VDC (Contact), Random, DC Output
PANASONIC

ACTDF8137

SAW Filter
ACT

ACTE-111-B

Limit Alarms (potentiometer adj.) A-UNIT
MSYSTEM

ACTE-111-C

Limit Alarms (potentiometer adj.) A-UNIT
MSYSTEM

ACTE-111-D

Limit Alarms (potentiometer adj.) A-UNIT
MSYSTEM

ACTE-111-F

Limit Alarms (potentiometer adj.) A-UNIT
MSYSTEM

ACTE-111-G

Limit Alarms (potentiometer adj.) A-UNIT
MSYSTEM