6BPA-021S1 [MSYSTEM]
Field-mounted Two-wire Signal Conditioners 6B-UNIT;型号: | 6BPA-021S1 |
厂家: | M-SYSTEM |
描述: | Field-mounted Two-wire Signal Conditioners 6B-UNIT |
文件: | 总4页 (文件大小:115K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 6BPA
3: PG 13.5
Field-mounted Two-wire
Signal Conditioners 6B-UNIT
[2] ENCLOSURE MATERIAL
A: Diecast aluminum
FREQUENCY TRANSMITTER
(field-selectable freq. range)
S: Stainless steel casting
Functions & Features
• IP66 / IP67 housing enables field mounting
• Stainless steel field housing selectable
• Transmitter with pulse signal input
• Input frequency range freely configurable
[3] MOUNTING BRACKET
0: Without
1: With
PACKAGE INCLUDES...
• Mounting screws
Bolt (M8 x 15): 4
Spring washer for M8: 4
Material: Stainless steel 304
• Mounting bracket assembly (option):
Mounting bracket: 1
M10 U-bolt: 2
Nut for M10: 4
Spring washer for M10: 4
Material: Stainless steel 304
Applicable pipe: 1 1/2” min.; 2” max.
MODEL: 6BPA-02[1][2][3]
GENERAL SPECIFICATIONS
Degree of protection: NEMA 4X, IP66/IP67
Wiring conduit: See ‘Ordering information.’
Electrical connection: M3 screw terminals
(torque 0.6 N·m)
ORDERING INFORMATION
• Code number: 6BPA-02[1][2][3]
Specify a code from below for each of [1] through [3].
(e.g. 6BPA-020A1)
• Input range (e.g. 0 - 500 Hz)
Select from the frequency variable ranges below.
Frequency variable range: adjustment range
36 - 100 Hz: 36 - 120 Hz
Materials
• Transmitter housing: Diecast aluminum
Screw terminals: Nickel-plated steel
• Enclosure: Diecast aluminum or stainless steel casting
(equivalent to type 316); silver color, epoxy resin coated
Isolation: Input or output to outdoor enclosure
Zero adjustment: -5 to +5 % (behind the access cover)
Span adjustment: 95 to 105 % (behind the access cover)
100 - 240 Hz: 90 - 300 Hz
240 - 480 Hz: 180 - 600 Hz
480 Hz - 1.0 kHz: 360 Hz - 1.2 kHz
1.0 - 2.4 kHz: 0.9 - 3.0 kHz
2.4 - 4.8 kHz: 1.8 - 6.0 kHz
4.8 - 12 kHz: 3.6 - 12 kHz
INPUT SPECIFICATIONS
■ Voltage Pulse:
SAFETY APPROVAL
0: None
Frequency range: 0 – 36 Hz through 12 kHz
Input amplitude:
100 mVp-p – 50 Vp-p (≤ 1.2 kHz range)
200 mVp-p – 50 Vp-p (≥ 0.9 kHz range)
Pulse width requirement: Duty ratio 20 – 80 %
Input impedance: 100 kΩ
INPUT
2: Voltage pulse
[1] WIRING CONDUIT
0: G 1/2
1: 1/2 NPT
2: M20 × 1.5
6BPA SPECIFICATIONS
ES-8888 Rev.1 Page 1/4
http://www.m-system.co.jp/
MODEL: 6BPA
OUTPUT SPECIFICATIONS
Output: 4 – 20 mA DC
Load resistance vs. supply voltage: Load Resistance (Ω) =
(Supply Voltage (V) – 13 (V)) ÷ 0.02 (A)
(including leadwire resistance)
750
600
450
300
150
0
10 13 15
20
25 28
SUPPLY VOLTAGE [V]
(550Ω maximum at 24V DC)
INSTALLATION
Supply voltage: 13 – 28 V DC
Operating temperature: -5 to +70°C (23 to 158°F)
Weight:
• Unit
Approx. 1.5 kg (2.9 lb), aluminium
Approx. 4.2 kg (8.8 lb), stainless steel
• Mounting bracket assembly (option)
Approx. 0.78 kg (1.72 lb)
PERFORMANCE in percentage of span
Accuracy: ±0.2 % (±0.5 % at spans ≤ 600 Hz)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: Approx. 4 sec. (0 – 90 %)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input or output to outdoor enclosure )
6BPA SPECIFICATIONS
ES-8888 Rev.1 Page 2/4
http://www.m-system.co.jp/
MODEL: 6BPA
EXTERNAL DIMENSIONS unit: mm (inch)
MOUNTING BRACKET
(optional)
92 (3.62)
110 (4.33)
4–M8, 12 deep
SPACE REQUIRED TO REMOVE COVER
114 (4.49)
110 (4.33)
2–G 1/2, 1/2NPT, M20x1.5 or PG13.5
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
S
Z
24V DC
+
−
+
−
Low Drift
Amplifier
Output
Driver
One-Shot
1
2
3
4
5
6
INPUT
LOAD
OUTPUT
4 − 20mA DC
6BPA SPECIFICATIONS
ES-8888 Rev.1 Page 3/4
http://www.m-system.co.jp/
MODEL: 6BPA
Specifications are subject to change without notice.
6BPA SPECIFICATIONS
ES-8888 Rev.1 Page 4/4
http://www.m-system.co.jp/
相关型号:
©2020 ICPDF网 联系我们和版权申明