47LPT-161YR-M2 概述
Digital Panel Meters 47 Series
47LPT-161YR-M2 数据手册
通过下载47LPT-161YR-M2数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 47LPT
Digital Panel Meters 47 Series
[3] DISPLAY COLOR
R: Red
YR: Orange
G: Green
VT INPUT DIGITAL PANEL METER
(4½ digit, LED display type, true RMS sensing)
Functions & Features
BG: Bluegreen
B: Blue
• 4½ digit VT input digital panel meter
• 1/8 DIN size
W: White
• Moving average function to suppress the display flickering
• Max. and Min. value display
[4] POWER INPUT
• IP66 front panel
AC Power
• Separable terminal block
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
• Rear terminal cover for safety strapped to the meter
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
96 (3.78)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
H
H
H
48
(1.89)
P
L
L
L
Zr
o
Sp
n
D/P
[5] OPTIONS
blank: none
Tc
h
Fnc
Mi
n
Max
Ma
x/M
in
A
la
rm
/
S
ca
le
/
S
hif
t
U
p
98.5 (3.88)
/Q: With options (specify the specification)
mm (inch)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
MODEL: 47LPT-1[1][2][3]-[4][5]
ORDERING INFORMATION
• Code number: 47LPT-1[1][2][3]-[4][5]
Specify a code from below for each of [1] through [5].
(e.g. 47LPT-101G-M2/Q)
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9506)
INPUT
1: AC voltage
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
[1] DC OUTPUT
0: Without
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Voltage
Connection: M3 separable screw terminal (torque 0.6 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
Housing material: Flame-resistant resin (gray)
Isolation: Input to DC output to HH output or H output to
L output or LL output to power
Input waveform
RMS sensing: Up to 15 % of 3rd harmonic content
Setting: (Front button)
[2] ALARM OUTPUT
0: None
• Scaled range
• Input type
1: N.O. relay contact, 4 points
2: SPDT relay contact, 2 points
• Alarm setpoint
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 1/7
https://www.m-system.co.jp/
MODEL: 47LPT
• Hysteresis (deadband)
OUTPUT SPECIFICATIONS
■ DC Output
• Moving average
• Others
• DC Current
(Refer to the instruction manual for details)
Read rate: 40 times/sec. (25 msec.)
Averaging: None or moving average
Lockout setting: Prohibiting certain operations; protecting
settings
Operational range: -5 – +105 %
• DC Voltage
Operational range: -5 – +105 %
■ Alarm Output: Relay contact
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
DISPLAY
Display: 16 mm (.63) high, 4 ½ digits, 7-segment LED
Display range: -19999 to 19999
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)
6
Decimal point position: 10–1, 10–2, 10–3, 10–4 or none
Zero indication: Higher-digit zeros are suppressed.
Over-range indication: ‘-19999’ or ‘19999’ blinking for
display values out of the scaled range.
‘S.ERR’ and ‘Max’ blinking when the input signal is out of
the usable range.
INSTALLATION
Power consumption
•AC: Approx. 6.5VA
•DC: Approx. 3 W
Alarm status indication
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
LL indicator: Green turns on when the LL alarm is tripped.
L indicator: Green turns on when the L alarm is tripped.
H indicator: Red turns on when the H alarm is tripped.
HH indicator: Red turns on when the HH alarm is tripped.
P indicator: Amber turns on when none of the other alarms
is tripped.
Weight: 300 g (0.66 lb)
PERFORMANCE
Accuracy
Note: Only ‘P’ turns on with no-alarm-output type. ‘LL’ or
‘HH’ does not turn on with dual-alarm-output type.
All setpoints can be independently set either for Hi or Lo
alarm trip.
Display: ±0.5 % ±10 digits with input 5 – 100 %
Output: ±0.1 %
(DC output = display + output)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Input resolution: Max. 16 bits
Function indicators:
Zro, Spn, D/P, Tch, Fnc, Min, Max
Output resolution: Max. 14 bits
Display mode status and operation status, amber ON or
blink
Response time: ≤ 0.5 sec.
(alarm output: 0 – 100 % at 90 % setpoint)
≤ 0.5 sec. (DC output: 0 – 90 %)
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute (input to DC
output to HH output or H output to L output or LL output to
power to ground)
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
m3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
STANDARDS & APPROVALS
EU conformity:
INPUT SPECIFICATIONS
Frequency: 50 or 60 Hz
EMC Directive
EMI EN 61000-6-4
Overload capacity: 450 V for 10 sec., 360 V continuous
Default measuring range: 0 – 300 V
EMS EN 61000-6-2
Low Voltage Directive
EN 61010-1
TYPE MEASURING OPERATIONAL
INPUT
IND
RANGE
0 – 150V
0 – 300V
RANGE
0 – 165V
0 – 330V
BURDEN
Measurement Category III (input)
Measurement Category II (alarm output)
Installation Category II (power)
Pollution Degree 2
V150
V300
≤0.5VA
≤0.5VA
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 2/7
https://www.m-system.co.jp/
MODEL: 47LPT
Input to alarm output to power: Reinforced insulation
(300 V)
RoHS Directive
Protection against access to the terminal blocks:
Finger protection (VDE 0660-514)
EXTERNAL VIEW
(1) Main Display
HH
H
P
(2) Alarm Indicators
L
LL
Zro Spn D/P
Tch Fnc Min Max
(3) Function Indicators
Max/Min
Alarm/
Scale/
Shift
Up
(8) Up Button
(7) Shift Button
(6) Scale/ Button
(4) Max/Min Button
(5) Alarm/ Button
• COMPONENT IDENTIFICATION
No. COMPONENT
(1) Main display
FUNCTION
Indicates present values, setting values and status of the unit.
Indicate alarm status of the input signal.
(2) Alarm indicators
(3) Function indicators
(4) Max/Min button
Indicate the status in each setting mode.
Used to switch the main display to show the present values, maximum values or minimum values etc.
(5)
Used to con!rm alarm setting value and to move on to the alarm and other setting modes; or to shift through
setting items in each setting mode.
Alarm/ button
(6)
Used to move on to the scaling and other setting modes; or to shift through setting items in each setting
mode.
Scale/ button
(7) Shift button
(8) Up button
Used to move on to the setting standby status of each setting mode and shift through display digits in each
setting mode.
Used to execute/cancel Forced Zero or to select setting values in each setting mode.
Note: Refer to the operating manual for details on each function.
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 3/7
https://www.m-system.co.jp/
MODEL: 47LPT
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■
TOP VIEW
95 (3.74)
■
FRONT VIEW
■ SIDE VIEW
103 (4.06)
96 (3.78)
98.5 (3.88)
86 (3.39)
12.5 (.49)
2 (.08)
■
REAR VIEW
• Alarm Output
• No Alarm Output
10–M3 SCREW
TERMINAL
20–M3 SCREW
TERMINAL
6.6 (.26)
2–M3 SCREW
4–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
91.5 (3.60)
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 4/7
https://www.m-system.co.jp/
MODEL: 47LPT
MOUNTING REQUIREMENTS unit: mm
92 +– 00.8
min. 120
Panel thickness: 1.6 to 8.0 mm
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 5/7
https://www.m-system.co.jp/
MODEL: 47LPT
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ALARM OUTPUT CODE 0: No alarm output
SOURCE
Isolation
VT
FUSE
U
V
u
v
Output
Driver
+
1
3
7
8
9
A/D
Converter
DC OUTPUT
Digital
Computation
–
LOAD
2
4
5
6
U(+)
Display /
Setting
POWER
10 V(–)
■ALARM OUTPUT CODE 1: N.O. contact, 4 points
SOURCE
Isolation
VT
FUSE
U
V
u
v
Output
Driver
+
–
1
3
7
8
A/D
Converter
DC OUTPUT
Ry
Ry
LOAD
2
4
Digital
Computation
Display /
Setting
15 HHa
16 Ha
HH OUTPUT
H OUTPUT
5
6
17 Hc, HHc
Ry
Ry
11
12
13
14
18 La
L OUTPUT
19 LLa
LL OUTPUT
20 Lc, LLc
U(+)
10 V(–)
9
POWER
■ALARM OUTPUT CODE 2: SPDT contact, 2 points
SOURCE
Isolation
VT
FUSE
U
V
u
v
Output
Driver
+
–
1
3
7
8
A/D
Converter
DC OUTPUT
Ry
LOAD
2
4
Digital
Computation
Display /
Setting
15 Ha(NO)
16 Hb(NC)
H OUTPUT
L OUTPUT
5
17 Hc(COM
18 La(NO)
19 Lb(NC)
)
6
Ry
11
12
13
14
20 Lc(COM
U(+)
10 V(–)
)
9
POWER
■Relay Protection
• AC Powered
Note: The section enclosed by broken line is only with
DC output option.
• DC Powered
Inductive
Load (Coil)
Inductive
Load (Coil)
Varistor or
CR Circuit
Diode, Varistor or
CR Circuit
LOAD
LOAD
U
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 6/7
https://www.m-system.co.jp/
MODEL: 47LPT
Specifications are subject to change without notice.
47LPT SPECIFICATIONS
ES-9506 Rev.14 Page 7/7
https://www.m-system.co.jp/
47LPT-161YR-M2 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
47LPT-161YR-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-161YR-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-161YR-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-161YR-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-161YR-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-162B-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-162B-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-162B-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-162B-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47LPT-162B-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 |
47LPT-161YR-M2 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6