47DR-1111-P 概述
Digital Panel Meters 47 Series
47DR-1111-P 数据手册
通过下载47DR-1111-P数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载MODEL: 47DR
Digital Panel Meters 47 Series
[2] EXCITATION SUPPLY
1: +12 V sensor excitation
2: +24 V two-wire transmitter excitation
RTD INPUT DIGITAL PANEL METER
(5 digit, LCD display type)
Functions & Features
[3] I/O OPTIONS
• 5 digit RTD input digital panel meter
• 1/8 DIN size
0: None
1: Alarm output: N.O. relay, 4 points
2: Alarm output: SPDT relay, 2 points
3: Alarm output: N.O. photo MOSFET relay, 4 points
4: Network interface: RS-485 / Modbus RTU
5: BCD output
• Display color can be changed at alarm
• Bargraph indicator shows approximate measuring status
• 12 V or 24 V excitation supply
• External event trigger input
• RS-485 / Modbus RTU output
• Infrared interface
6: Event trigger input
7: Alarm output: N.O. relay, 4 points
+ Network interface: RS-485 / Modbus RTU
8: Alarm output: SPDT relay, 2 points +
Network interface: RS-485 / Modbus RTU
9: Alarm output: N.O. photo MOSFET relay, 4 points + BCD output
A: Event trigger input + BCD output
• BCD output
• Loop test output (DC output option)
• IP66 front panel
• Separable terminal block
• Safety terminal cover tethered to the device with a strap
96 (3.78)
[4] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
M
a
x
M
in
48
(1.89)
Hld
TG
DC Power
N
G
Ini
A
lm
°F
°C
R: 24 V DC
Ma
x/M
in
A
la
rm
/
In
it/
S
hif
t
U
p
98.5 (3.88)
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
mm (inch)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
MODEL: 47DR-1[1][2][3]-[4][5]
[5] OPTIONS
blank: none
ORDERING INFORMATION
• Code number: 47DR-1[1][2][3]-[4][5]
Specify a code from below for each [1] through [5].
(e.g. 47DR-1111-M2/Q)
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
/C02: Polyurethane coating
INPUT – Field-selectable
RTD
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
1: JPt 100 (JIS ’89)
Pt 100 (JIS ’89)
EX-FACTORY SETTING
Pt 100 (JIS ’97, IEC)
Pt 50Ω (JIS ’81)
Pt 1000
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9509)
RELATED PRODUCTS
• Connector terminal block (model: CNT)
[1] DC OUTPUT
0: Without
• Special cable (model: HDR40)
1: With
• Infrared Communication Adaptor (model: COP-IRU)
• PC configurator software (model: 47DCFG)
Downloadable at M-System’s web site.
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 1/12
http://www.m-system.co.jp/
MODEL: 47DR
or ‘OVER’ (sub display) blinking when the input signal is out
of the usable range.
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
Burnout indication: ‘B.ERR’ blinking
Bargraph
No. of LED segments: 20, displayed with divided by 10
Color: Amber
Connection
Alarm status indication
Input, excitation supply, DC output, relay output,
network interface, power: M3 separable screw terminal
(torque 0.6 N·m)
All setpoints can be set and indicated regardless of alarm
output options. Each is independently set either for Hi or Lo
alarm trip.
Photo MOSFET relay, event trigger input: Euro Type
Connector Terminal
LL indicator: Turns on in red when the LL alarm is tripped.
L indicator: Turns on in red when the L alarm is tripped.
H indicator: Turns on in green when the H alarm is tripped.
HH indicator: Turns on in green when the HH alarm is
tripped.
(applicable wire size: max. 1.3 dia., 0.5 – 1.25 mm
2,
stripped length 7 - 8 mm)
BCD output: 50-pin connector
(Honda Tsushin Kogyo HDR-EC50LFDT1-SLE+)
P indicator: Turns on in amber when none of the other
alarms is tripped.
Screw terminal: Nickel-plated steel (standard) or stainless
steel
Status indicators: Max, Min
Housing material: Flame-resistant resin (gray)
Isolation: Input or excitation supply to DC output to
HH output or H output to L output or LL output to network or
BCD output or event trigger input to power
Burnout: Upscale standard; downscale optional by
programming
Display max./min. value, Amber LED turns on
Function indicators
Hld: Turns on in green when HOLD signal is ON
TG: Turns on in green when TIMING signal is ON
NG: Turns on in green when a parameter is invalid
Ini: Unused
Linearization: Standard
Alm: Unused
Infrared communication: Transmission distance max. 1
meter (for use with the COP-IRU)
Setting: (Front button)
°F: Turns on in green when temperature unit is set to °F
℃ : Turns on in green when temperature unit is set to ℃
Engineering unit indication: Sticker label attached
DC, AC, mV, V, kV, μA, mA, A, kA, mW, W,
kW, var, kvar, Mvar, VA, Hz, Ω, kΩ, MΩ,
cm, mm, m, m/sec, mm/min, cm/min, m/min,
• Input type
• Alarm setpoint
• Hysteresis (deadband)
• Averaging
m/h, m/s2, inch, ℓ, ℓ/s, ℓ/min, ℓ/h, m3, m3/sec,
• Burnout
m3
/min, m
3
/h, Nm /h, N·m, N/m , g, kg, kg/h,
3
2
• Others
N, kN, Pa, kPa, MPa, t, t/h, ℃, °F, %RH, J,
kJ, MJ, rpm, sec, min, min-1, pH, %, ppm, etc.
(Refer to the instruction manual for details)
Sampling rate: 20 times/sec. (50 msec.)
Averaging: Simple average, moving average or no
averaging
EXCITATION SUPPLY
■ +12V SENSOR EXCITATION
Output voltage (across the terminals 5 – 6): 12 – 16 V DC
with no load
Lockout setting: Prohibiting certain operations; protecting
settings
10.8 V DC minimum at 80 mA
Current rating: 84 mA DC maximum
• Shortcircuit Protection
DISPLAY
Main display: 5 digits (6 digits when parameter is setting),
LCD with LED backlight, 7-segment, 14.2 mm (.56) high
Color: Red or green changeable at alarm
Display range: -20000 to 99999
Current limited: 97 mA maximum
Protected time duration: No limit
■ +24V TWO-WIRE TRANSMITTER EXCITATION
Output voltage (across the terminals 5 – 6): 24 – 28 V DC
with no load
Decimal point position: 2 decimal places, 1 decimal place
or none
Zero indication: Higher-digit zeros are suppressed.
Sub display: 7 digits, LCD with LED backlight, 7-segment,
5.5 mm (.22) high
22 V DC minimum at 20 mA
Current rating: ≤ 22 mA DC
• Shortcircuit Protection
Color: Green
Current limited: 30 mA max.
Over-range indication: ‘S.ERR’ (main display) and ‘UNDER’
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 2/12
http://www.m-system.co.jp/
MODEL: 47DR
Protected time duration: No limit
RESET: Reset data
The device is reset when RESET signal is
turned on.
INPUT SPECIFICATIONS
■ RTD: 3-wire RTDs
■ Alarm Output: Relay contact
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum leadwire resistance: 20 Ω per wire
Sensing current: 1mA (JPt 100, Pt 100), 2mA (Pt 50Ω),
0.1mA (Pt 1000)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
Temperature Range
CONFORMANCE
RANGE
RTD
USABLE RANGE
Mechanical life: ≥ 5 × 10 cycles (rate 180 cycles/min.)
6
-230.00 1 to +530.00
*
JPt 100
(JIS ’89)
°C -200.00 to +500.00
■ Alarm Output: Photo MOSFET relay
Rated load: 120 V AC/DC @ 80 mA (resistive load)
ON resistance: 25 Ω
-328.0 to +932.0
°F
-382.0 to +986.0
-230.00 1 to +680.00
*
Pt 100
(JIS ’89)
-200.00 to +650.00
-328.0 to +1202.0
-200.00 to +850.00
-328.0 to +1562.0
°C
°F
°C
°F
-382.0 to +1256.0
-230.00 1 to +880.00
Permissible loss: 250 mW
*
Pt 100
■ Network Interface
(JIS ’97,IEC)
-382.0 to +1616.0
*
Transmission: Half-duplex, asynchronous, no procedure
Interface: Conforms to TIA/EIA-485-A
Max. transmission distance: 500 meters
Baud rate: 1.2 – 38.4 kbps
°C -200.00 to +649.00 -230.00 1 to +679.00
Pt 50Ω
(JIS ’81)
-328.0 to +1200.2
°C -200.00 to +850.00
-328.0 to +1562.0
-382.0 to +1254.2
-230.00 1 to +880.00
°F
*
Pt 1000
°F
-382.0 to +1616.0
Max. number of nodes: 31 (except the master)
Protocol: Modbus RTU
*1. -200.00 when number of decimals display is set to two places
of decimals.
Parity: None, odd or even
Stop bit: 1 bit, 2 bits
DC OUTPUT SIGNAL SPECIFICATIONS
VOLTAGE OUTPUT
Node address: 1 to 247
Media: Shielded twisted-pair cable (CPEV-S 0.9 dia.)
Terminating resistor: Built-in (Connect across T2 - T3, when
the unit is the end of the line)
OUTPUT OPERATIONAL
LOAD
RESISTANCE
TYPE ID
RANGE
0 – 5V
5V
RANGE
-0.5
–
+5.5V
2000Ω minimum
4000Ω minimum
8000Ω minimum
■ BCD Output + Control Signals
• Input Signals: Dry contact or NPN open collector
Input current: ≤ 3 mA
-6 – +6V
-12 – +12V
10V
CURRENT OUTPUT
OUTPUT OPERATIONAL
Sensing: 6 V
LOAD
RESISTANCE
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
TYPE ID
RANGE
0 – 20mA
4 – 20mA
RANGE
-2 – +22mA
400Ω maximum
REQ: Request BCD data
2.4 – 21.6mA 400Ω maximum
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
MIN_REQ: Request Minimum reading data
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
I/O OPTIONS
■ Event Trigger Input: Dry contact or NPN open collector
Input current: ≤ 3 mA
MAX_REQ: Request Maximum reading data
Valid data in approx. 30 msec. after detecting
the signal’s rising edge
Sensing: 6 V
Contact detecting: ≤ 1.5 V at ON; ≥ 3 V at OFF
Signal ID and Details
HOLD: Hold data
S_TMR: Startup Timer
Reading measured signal stops and the last value is
held when HOLD signal is turned on.
RESET: Reset data
Measuring starts in the predetermined time after
detecting the signal turning on.
TIMING: Timing
All BCD data turn off when RESET signal is
turned on.
Used for various timing hold functions
ZERO: Forced Zero
• Output Signals: NPN open collector
Max. load voltage: 24 V DC
Not used
HOLD: Hold data
Max. load current: 10 mA
Reading measured signal stops and the last value is held
when HOLD signal is turned on.
Saturation voltage: ≤ 0.3 V DC
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 3/12
http://www.m-system.co.jp/
MODEL: 47DR
Leakage current: ≤ 500 μA
Signal ID and Details
(input or excitation supply to DC output to HH output or H
output to L output or LL output to network or BCD output or
event trigger input to power to ground)
DATA (Do 11...Do 68): BCD output data in 6 digits
Do 1x = LSD ... Do 6x = 6th LSD
POL: BCD Polarity
ON = (–), OFF = (+)
OVF: BCD Overflow/underflow
Output given at overflow or underflow
DAV: Data Valid
ON = valid, OFF = invalid
RUN: Run
Means the meter is functioning.
ON = Measuring or testing mode
OFF = Error except overflow/underflow
No DAV or DATA output is given when
RUN signal is not provided.
• Alarm Output Signals: NPN open collector
Max. load voltage: 24 V DC
Max. load current: 50 mA
Saturation voltage: ≤ 1.1 V
Leakage current: ≤ 500 μA
Signal ID and Details
HH: HH alarm trip output
H: H alarm trip output
PASS: PASS zone output
L: L alarm trip output
LL: LL alarm trip output
INSTALLATION
Power consumption
•AC: Max. 12 VA
•DC: 3.5 W max.
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Panel flush mounting
Weight: 300 g (0.66 lb)
PERFORMANCE in percentage of max. span
Accuracy
Display: ±0.5°C ±1 digit (±0.9°F ±1 digit)
Output: ±0.1% (DC output = display + output)
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Input resolution: Max. 19 bits
Output resolution: Max. 14 bits
Response time: ≤ 0.5 sec.
(alarm output: 0 – 100 % at 90 % setpoint)
≤ 0.5 sec. (DC output: 0 – 90 %)
Burnout response: ≤ 5 sec.
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 4/12
http://www.m-system.co.jp/
MODEL: 47DR
EXTERNAL VIEW
(3) Status Indicators
(4) Alarm Indicators
(1) Main Display
Max
Min
HH
H
P
(5) Bargraph
L
Hld TG NG Ini Alm °F °C
LL
(2) Sub Display
(6) Function Indicators
Max/Min
Alarm/
Init/
Shift
Up
(12) Up Button
(11) Shift Button
(10) Init/ Button
(7) Infrared Interface
(8) Max/Min Button
(9) Alarm/ Button
• COMPONENT IDENTIFICATION
No. COMPONENT FUNCTION
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Main display
Sub display
Indicates present values, setting values and status of the unit.
Indicates the present setting mode.
Status indicators
Alarm indicators
Bargraph
Indicate Max/Min display mode.
Indicate alarm status of the input signal.
Indicates present signal level against the temperature range.
Function indicators Indicate the device status.
Infrared interface
Max/Min button
Alarm/ button
Used for the infrared communication.
Used to switch the main display to show present values, maximum values or minimum values etc.
Used to confirm alarm setpoints and to move on to the alarm and other setting modes; or to shift
through setting items in each setting mode.
(10) Init/ button
Used to move on to the initial and other setting modes; or to shift through setting items in each
setting mode.
(11) Shift button
(12) Up button
Used to move on to the setting standby status and shift through display digits in each setting item.
Used to change setting values.
Note: Refer to the operating manual for details on each function.
COMMUNICATION CABLE CONNECTIONS
R2K-1
RS-485
RS-485
47Dx
T1
47Dx
T1
T1
T2
T3
T4
RS-232-C
T2
T2
1
1
*
*
T3
T3
T4
T4
2
*
FG
*1. Internal terminating resistor is used when the device is at the end of a transmission line.
*2. Install shield cables to all sections and ground them at single point.
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 5/12
http://www.m-system.co.jp/
MODEL: 47DR
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
■ TOP VIEW
95 (3.74)
■ FRONT VIEW
■ SIDE VIEW
103 (4.06)
96 (3.78)
98.5 (3.88)
86 (3.39)
12.5 (.49)
2 (.08)
■ REAR VIEW
10–M3 SCREW
TERMINAL
20–M3 SCREW
TERMINAL
• Alarm Output, RS-485/Modbus
• No Options
6.6 (.26)
2–M3 SCREW
4–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
20
11
12
13
14
15
16
17
18
19
91.5 (3.60)
•
BCD Output, Event Trigger Input, Alarm Output (Photo MOSFET Relay)
10–M3 SCREW
TERMINAL
2–M3 SCREW
1
2
3
4
5
6
7
8
9
10
1B
1A
25B
25A
11 12 13 14 15 16
EURO TYPE
50-pin CONNECTOR
CONNECTOR TERMINAL
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 6/12
http://www.m-system.co.jp/
MODEL: 47DR
MOUNTING REQUIREMENTS unit: mm
92 +– 00.8
min. 120
Panel thickness: 1.6 to 8.0 mm
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
■ REAR TERMINAL ASSIGNMENTS
TERMINAL A
1
2
3
4
5
6
7
8
9
10
20
1
2
3
4
5
6
7
8
9
10
TERMINAL D
11
12
13
14
15
16
17
18
19
TERMINAL C
TERMINAL B
1B
1A
25B
25A
11 12 13 14 15 16
■TERMINAL A : BASIC
Isolation
RTD
A
B
B
1
2
3
5
6
4
Output
Driver
+
7
8
9
A/D
Converter
DC OUTPUT
–
Digital
Computation
U(+)
Display /
Setting
POWER
+
Excitation
Supply
10 V(–)
EXCITATION
–
Infrared
Interface
Note: The section enclosed by broken line is only with DC output option.
• Excitation Supply Connection Examples
+12V Sensor Excitation
+24V Two-wire Transmitter Excitation
Max. 80mA is allowed on the sensor excitation loop.
The excitation is Not isolated from the RTD input.
DO NOT SHORT across the terminals 1 / 2 / 3 and 5 / 6.
The exictation supply can be used to power a two-wire transmitter.
The excitation is Not isolated from the RTD input.
DO NOT SHORT across the terminals 1 / 2 / 3 and 5 / 6.
RTD
RTD
A
B
B
A
B
B
1
2
3
5
6
1
2
3
5
6
Two-wire
Transmitter
+
–
+
–
+
–
SENSOR
4 – 20mA DC
+12V
+24V
RECEIV.
INSTR.
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 7/12
http://www.m-system.co.jp/
MODEL: 47DR
■ TERMINAL B
• Alarm Output : N.O. contact, 4 points
• Alarm Output : SPDT contact, 2 points
Ry
11
11
12
13
14
Ry
15 HHa
16 Ha
15 Ha(NO)
16 Hb(NC)
Ry
HH OUTPUT
L OUTPUT
12
13
14
H OUTPUT
L OUTPUT
H OUTPUT
Digital
Computation
Digital
Computation
17 Hc, HHc
17 Hc(COM
18 La(NO)
19 Lb(NC)
)
Ry
Ry
Ry
18 La
19 LLa
LL OUTPUT
20 Lc, LLc
20 Lc(COM
)
■ Relay Protection
• AC Powered
• RS-485 / Modbus RTU
Inductive
Load (Coil)
Isolation
15
16
17
18
19
20
Shielded Twisted-pair Cable
Digital
Computation
Output
Driver
Varistor or
CR Circuit
+
–
T1
T2
T3
T4
11
12
13
14
To other
Modbus devices
LOAD
Term.
Resist.
U
Jumper *1
• DC Powered
Inductive
Load (Coil)
Diode, Varistor or
CR Circuit
LOAD
*1. When the device is located at the end of a transmission line via twisted-pair cable
(when there is no cross-wiring), close across the terminal 12 – 13 with a leadwire.
When the device is not at the end, no shortcircuit wire is required.
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 8/12
http://www.m-system.co.jp/
MODEL: 47DR
■ TERMINAL C : BCD OUTPUT
• Connector Pin Assignment
Isolation
PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT
Digital
Computation
BCD
Output
1B
1A
25B
25A
1A
2A
COM
COM
LL
1B
2B
Do 38
COM
Do 34
COM
Do 32
COM
Do 31
COM
Do 28
COM
Do 24
COM
Do 22
COM
Do 21
Do 68
Do 18
Do 64
Do 14
Do 62
Do 12
Do 61
Do 11
COM
COM
3A
3B
4A
L
4B
5A
PASS
H
5B
6A
6B
7A
HH
7B
8A
POL
8B
9A
RESET
HOLD
MIN_REQ
MAX_REQ
REQ
9B
10A
11A
12A
13A
14A
15A
16A
17A
18A
19A
20A
21A
22A
23A
24A
25A
10B
11B
12B
13B
14B
15B
16B
17B
18B
19B
20B
21B
22B
23B
24B
25B
• Open collector
COM
RUN
Output
DAV
OVF
Do 58
Do 54
Do 52
Do 51
Do 48
Do 44
Do 42
Do 41
• Output Logic
Voltage Level at ON
Output Logic
Positive
Hi
Lo
Negative
• Connected to a PLC (example)
• Connected to a digital display (example)
Digital Panel Meter
+24 V
DC Power Supply
COM
+6 V
0 V
Digital Panel Meter
+6 V
shortcircuit
2 kΩ
REQ
PLC Transistor Output Unit
1.5 kΩ
2 kΩ
REQ
OUT
OUT
2 kΩ
1.5 kΩ
9A
RESET
1.5 kΩ
2 kΩ
9A
RESET
COM
Do11
Do12
Do14
Do18
1.5 kΩ
COM
(0 V)
23B
21B
19B
17B
24 V DC
1st LSD
BCD Input Module
COM
Do11
Do12
Do14
Do18
COM
IN
23B
21B
19B
17B
6th LSD
2nd LSD
16A
15A
8A
DAV
RUN
POL
IN
1st LSD
IN
IN
(polarity +, –)
16A
15A
8A
DAV
RUN
POL
IN
IN
IN
Digital Display
Use Special cable (model: HDR40) and Connector Terminal Block
(model: CNT).
Refer to the cable’s data sheet for pin assignments.
(polarity +, –)
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 9/12
http://www.m-system.co.jp/
MODEL: 47DR
■ TERMINAL D
• Alarm Output : Photo MOSFET Relay N.O. contact, 4 points
• Event Trigger Input
Isolation
Ry
Digital
Computation
11 HHa
11 TIMING
12 S-TMR
Ry
HH OUTPUT
12 Ha
H OUTPUT
Digital
Computation
13 Hc, HHc
13 HOLD
14 RESET
15 ZERO
16 COM
Digital
Computation
Ry
Ry
14 La
L OUTPUT
15 LLa
LL OUTPUT
16 Lc, LLc
Connection Example
TIMING : 11
S-TMR : 12
HOLD : 13
RESET : 14
ZERO : 15
+6 V
2 kΩ
1.5 kΩ
NPN
dry
contact
open
collector
16
COM
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 10/12
http://www.m-system.co.jp/
MODEL: 47DR
BCD OUTPUT TIMING CHART
VIEWING ANGLE
Request signals (REQ, MAX_REQ, MIN_REQ) from an external
device (e.g. PLC) are required in order to read out BCD data.
All signals in the following charts are in the negative logic
(ON at LOW signal, as factory set).
The display is designed to provide the optimal legibility
when viewed from the angles as shown below.
• Timing Chart for Continuous Data Output
REQ
MAX_REQ Hi
MIN_REQ
Lo
*1
Hi
DATA
DAV
all data H
data
data
Lo
Hi
Lo
30 ms
approx.
40 ms
24 ms
40 ms
24 ms
64 ms
64 ms
Measured data is output every 64 ms while one of REQ signals (REQ,
MAX_REQ or MIN_REQ) remains ON. For Event trigger modes, the data
value is the same as the display.
• Timing Chart for Single Sampling Cycle Data Output
20 ms or wider (max. 50 ms)
REQ
MAX_REQ Hi
MIN_REQ
Lo
*1
DATA
Hi
all data H
data
all data H
Lo
Hi
DAV
Lo
30 ms
approx.
40 ms
16 ms
When one of REQ signals (REQ, MAX_REQ or MIN_REQ) is given and
its width is between 20 and 50 ms, DATA is established and DAV output
is given in approx. 30 ms from the falling edge of the REQ signal.
Read in the data to a PLC at the timing of the DAV output signal.
DAV is turned off in 40 ms. DATA is turned off in 16 ms after that.
•
Output is provided via open collector, enabling wired-OR gate configuration
REQ 1 Hi
Lo
Hi
REQ 2
Lo
Hi
Lo
Hi
REQ 3
*1
DATA
1
2
3
Lo
Hi
DAV
Lo
*2
*2
*2
When DATA output logic is negative, wired-OR connection is available
for BCD data, POL, OVF, HH, H, P, L and LL signals.
*1. DATA includes BCD Output, POL, OVF, HH, H, P, L, LL and RUN.
*2. Wait for at least 20 ms between DAV turning off and the next REQ signal.
REQ 1
47Dx
1
REQ 2
47Dx
2
PLC
REQ 3
47Dx
3
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 11/12
http://www.m-system.co.jp/
MODEL: 47DR
SYSTEM CONFIGURATION EXAMPLES
■ RS-485 / RS-232-C
■ RS-485 / ETHERNET
RS-232-C
Ethernet
RS-232-C/RS-485
Converter
(model: R2K-1 or LK1)
Communication Adaptor
(model: 72EM2-M4)
ETHERNET
RS-485
RUN
SEND
FIELD
CNFG
Lightning Surge Protector
for RS-485/422
(model: MD74R or MDP-4R) *1
Lightning Surge Protector
for RS-485/422
(model: MD74R or MDP-4R) *1
RS-485 (Modbus RTU)
RS-485 (Modbus RTU)
Lightning Surge
Protector for
RS-485/422
(model: MD74R
or MDP-4R) *1
Lightning Surge
Protector for
RS-485/422
(model: MD74R
or MDP-4R) *1
M
M
FZ
TZ
M
Mi
FZ
TZ
Max
ax
in
ax
n
M
M
FZ
TZ
M
Mi
FZ
TZ
M
M
FZ
TZ
ax
in
ax
n
ax
in
M
in
FZ
TZ
Hld
Hld
Hld
TG
NG
TG
TG
Hld
Hld
Hld
NG
NG
TG
TG
TG
Zr
o
Zr
o
Zr
o
NG
NG
NG
Spn
Sp
Spn
Tc
n
Zr
Zr
Zr
Tc
Tc
o
o
o
Sp
n
h
h
h
Spn
Sp
n
Tc
Tc
Tc
h
h
h
Digital Panel Meter
(model: 47Dx)
Digital Panel Meter
(model: 47Dx)
*1. Insert lightning surge protectors recommended in this example if necessary.
Specifications are subject to change without notice.
47DR SPECIFICATIONS
ES-9509 Rev.12 Page 12/12
http://www.m-system.co.jp/
47DR-1111-P 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
47DR-1111-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1111-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1111-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-M2/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-P | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-P/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-R | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1112-R/Q | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 | |
47DR-1113-M2 | MSYSTEM | Digital Panel Meters 47 Series | 获取价格 |
47DR-1111-P 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6