18KBXW-Y1 [MSYSTEM]

Rack-mounted DCS Signal Conditioners 18K-RACK;
18KBXW-Y1
型号: 18KBXW-Y1
厂家: M-SYSTEM    M-SYSTEM
描述:

Rack-mounted DCS Signal Conditioners 18K-RACK

DCS 分布式控制系统
文件: 总3页 (文件大小:140K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 18KBXW  
Screw terminal: Nickel-plated brass  
Rack-mounted DCS Signal Conditioners 18K-RACK  
Isolation: I/O connector to field connector to power to FG  
STANDARD RACK  
Functions & Features  
INSTALLATION  
Power input  
• Housing for storage of Rack-mounted DCS Signal  
Conditioners 18K-RACK  
DC: Operating voltage range 24 V DC ±10 %, 2.5 A  
minimum (ripple 10 % p-p max.)  
• Integrated rack and field connectors allow for signal  
conditioners to be removed without touching the terminal  
screws, making field wiring insulation tests possible  
• Can also be used for 18-RACK storage  
• Signal conditioner power supply is for all 16 units  
• Connectors are available for direct connection to  
Yokogawa Electric DCS units  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Mount to module inserts of Yokogawa Electric  
racks (models: CNC, CNM) (perforation required)  
Weight: Approx. 2.5 kg (5.51 lb)  
PERFORMANCE  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @1 minute  
(I/O connector to field connector to power)  
1000 V AC @1 minute  
(I/O connector or field connector or power to FG)  
MODEL: 18KBXW–[1]  
ORDERING INFORMATION  
Code number: 18KBXW-[1]  
Specify a code from below for [1].  
(e.g. 18KBXW-Y1)  
[1] CONNECTOR  
Y1: Yokogawa DCS MAC2 / PAC card use  
Y2: Yokogawa DCS VMx / PM1 card use  
RELATED PRODUCTS  
• Blank filler plate (model: P-181)  
GENERAL SPECIFICATIONS  
Construction: Metal plates assembly  
Coating: Colored Zn-Cr  
Capacity: 16 positions  
Connection  
Power: M4 screw terminals (torque: 0.8 N·m)  
Field connector: Japan Solderless Terminal MFG.Co.Ltd  
B04B-XASK-1-A  
http://www.m-system.co.jp/  
18KBXW SPECIFICATIONS  
ES-0490 Rev.0 Page 1/3  
MODEL: 18KBXW  
CONNECTION DIAGRAM  
CN1  
CN2  
1
2
3
+
POWER  
FG  
Note 1. For 18KTS and 18KJT models, directly connect input signals to  
input terminals of the converter and do not connect to Field  
Connectors.  
Note 2. Field Connector numbers correspond to Terminal numbers of the  
converters.  
Note 3. CN2 is provided only for Yokogawa DCS MAC2 /PAC  
card use.  
DIMENSIONS unit: mm (inch)  
CN1  
CN2  
2-M5 SCREW  
3-M4 POWER  
TERMINAL  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16  
1ch ... 4ch  
5ch ... 8ch  
9ch ... 12ch  
13ch ... 16ch  
15 (.59)  
162 (6.38)  
442 (17.40)  
1 2 3 4  
FIELD CONNECTOR  
BLOCK  
http://www.m-system.co.jp/  
18KBXW SPECIFICATIONS  
ES-0490 Rev.0 Page 2/3  
MODEL: 18KBXW  
I/O CONNECTOR PIN ASSIGNMENT  
Yokogawa DCS MAC2 / PAC card use  
(PS-40PE-D4LT1-PN1)  
Location  
CN1:  
CN2:  
MAC2 / PAC card use*  
MAC2 / PAC card use* (for redundancy)  
The input or output 1 is connected to the connector.  
18K-RACK LOCATION NO.  
7
1
2
3
4
5
6
8
9
10 11 12 13 14 15 16  
1
i
1
o
2
i
2
o
3
i
3
o
4
i
4
o
5
i
5
o
6
i
6
o
7
i
7
o
8
i
8
o
MAC2/PAC CARD I/O (i = input, o = output)  
*MAC2 card (uses KS1 cable)  
I/O card used for control I/O. Composed of 8 inputs  
and 8 outputs. Input and output are paired. (Replace  
with pulse inputs for PAC card.)  
Yokogawa DCS VMx / PM1 card use  
(PS-40PE-D4LT1-PN1)  
Location  
CN1:  
VMx / PM1 card use*  
The input or output 1 is connected to the connector.  
18K-RACK LOCATION NO.  
7
1
1
2
2
3
3
4
4
5
6
8
9
10 11 12 13 14 15 16  
5
6
7
8
9
10 11 12 13 14 15 16  
VM1/PM1/VM4 CARD INPUT or OUTPUT  
1
2
3
VM2 CARD INPUT NO.  
4
5
6
7
8
1
2
3
VM2 CARD OUTPUT NO.  
4
5
6
7
8
*VMx / PM1 card (uses KS2 cable)  
VM1: analog input 16 points  
VM2: analog input 8 points / analog output 8 points  
VM4: analog output 16 points  
PM1: pulse input 16 points  
Specifications are subject to change without notice.  
http://www.m-system.co.jp/  
18KBXW SPECIFICATIONS  
ES-0490 Rev.0 Page 3/3  

相关型号:

18KBXW-Y2

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDU

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDU-66-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDU-66-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A66-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A66-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A66-R/SL

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A6A-R

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A6A-R/S

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDY-A6A-R/SL

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM

18KDYH2

Rack-mounted DCS Signal Conditioners 18K-RACK
MSYSTEM