10PR-130-R/C03 [MSYSTEM]

High-density Signal Conditioners 10-RACK;
10PR-130-R/C03
型号: 10PR-130-R/C03
厂家: M-SYSTEM    M-SYSTEM
描述:

High-density Signal Conditioners 10-RACK

文件: 总3页 (文件大小:103K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MODEL: 10PR  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
High-density Signal Conditioners 10-RACK  
[3] OPTIONS  
blank: none  
PULSE SCALER  
Functions & Features  
/Q: With options (specify the specification)  
• Converting pulse rate into convenient engineering unit for  
display on a totalizing counter or meter  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
Typical Applications  
• Positive displacement flowmeters and turbine flowmeters  
• Magnetic tachometers  
/C02: Polyurethane coating  
/C03: Rubber coating  
CAUTION  
1) This unit's output waveform is not uniform due to its  
scaling method.  
2) Use input relays which do not cause chattering (e.g.  
mercury relays). Other relays could be used only with a CR  
filter, for 10 Hz at maximum.  
3) Use M-System’s Model M2PRU instead of this unit in  
conjunction with the pulse output from M-System’s power  
transducers.  
R
MODEL: 10PR–[1][2]0–R[3]  
C = 1 µF  
R = 10k ohms  
PULSE  
SCALER  
Relay  
C
ORDERING INFORMATION  
• Code number: 10PR-[1][2]0-R[3]  
Specify a code from below for each [1] through [3].  
(e.g. 10PR-110-R/Q)  
GENERAL SPECIFICATIONS  
Construction: Rack-mounted; terminal access via screw  
terminals at the front and via card-edge connector at the  
rear; terminal cover provided  
• Input frequency range (e.g. 0 – 356.7 Hz)  
• Output frequency range (e.g. 0 – 1.00 Hz)  
• Specify the specification for option code /Q  
(e.g. /C01)  
Connection  
Input: M3.5 screw terminals (torque 0.8 N·m)  
Output: Card-edge connector and M3.5 screw terminals  
(torque 0.8 N·m)  
[1] INPUT  
1: Dry contact (max. 100 kHz)  
Power input: Supplied from card-edge connector  
Screw terminal: Nickel-plated steel  
2: Voltage pulse (max. 100 kHz)  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
[2] OUTPUT 1  
Input pulse sensing: Capacitor coupled; detecting pulse rise  
Sensitivity adjustment: Single-turn screwdriver adjustment  
(front); 25 mVp-p – 5 Vp-p  
1: Open collector (max. frequency 20 kHz)  
2: 5 V pulse (max. frequency 20 kHz)  
3: Relay contact (max. frequency 2 Hz)  
4: 24 V pulse (max. frequency 20 Hz)  
Scaling factor: 0.9999 × 10 – 0.0001 × 10–6  
0
OUTPUT 2  
0: None  
INPUT SPECIFICATIONS  
Dry Contact: Mechanical contact or open collector  
Max. frequency: 100 kHz  
Pulse width time requirement: 5 μsec. min. (20 msec. min.  
for frequencies ≤ 10 Hz)  
POWER INPUT  
DC Power  
Sensing: Approx. 7.5 V DC @ 1 mA  
R: 24 V DC  
http://www.m-system.co.jp/  
10PR SPECIFICATIONS  
ES-0860 Rev.9 Page 1/3  
MODEL: 10PR  
ON/OFF level: ≤ 20 kΩ for ON, ≥ 100 kΩ for OFF  
Voltage Pulse: Square or sine waveforms*  
Max. frequency: 100 kHz  
Load resistance: 600 Ω minimum  
24 V Pulse  
Frequency range: 0 – 20 Hz  
High pulse width: Approx. 30 msec.  
High level: 24 V ±10 %  
Low level: ≤ 0.5 V  
Pulse width time requirement: 5 μsec. min. (20 msec. min.  
for frequencies ≤ 10 Hz)  
Input amplitude: 25 mVp-p – 50 Vp-p  
Minimum amplitude requirement  
With duty ratio 50 % ±10 %  
(frequency: amplitude)  
Load current: 30 mA max.  
Load resistance: 800 Ω minimum  
0 – 2 kHz: 25 mVp-p  
INSTALLATION  
0 – 20 kHz: 50 mVp-p  
Current consumption: Approx. 80 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Standard Rack 10BXx  
0 – 40 kHz: 1 Vp-p  
0 – 100 kHz: 5 Vp-p  
With duty ratio other than 50 % ±10 %  
(pulse width: amplitude)  
Weight: 200 g (0.44 lb)  
5 μsec.: 5 Vp-p  
10 μsec.: 3.5 Vp-p  
PERFORMANCE  
50 μsec.: 2 Vp-p  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 500 V AC @ 1 minute  
(input to output to power)  
100 μsec.: 1 Vp-p  
500 μsec.: 0.5 Vp-p  
Input impedance: 100 kΩ minimum  
1500 V AC @ 1 minute (input or output or power to ground)  
*Voltage pulse examples  
25mV – 50V  
0V  
25mV – 50V  
0V  
25mV p-p  
– 50V p-p  
0V  
OUTPUT SPECIFICATIONS  
■ Open Collector: 50 V DC @ 50 mA (resistive load)  
Frequency range: 0 – 20 kHz  
ON pulse width: Approx. 30 μsec.  
Saturation voltage: 0.6 V DC  
Relay Contact: 120 V AC @ 200 mA (cos ø = 1)  
240 V AC @ 100 mA (cos ø = 1)  
24 V DC @ 200 mA (resistive load)  
Maximum switching voltage: 240 V AC or 30 V DC  
Maximum switching power: 24 VA or 4.8 W  
Minimum load: 5 V DC @ 10 mA  
Frequency range: 0 – 2 Hz  
ON pulse width: Approx. 30 msec.  
Relay life: ≥ 5 × 10  
≥ 10 cycles (electrical)  
5 V Pulse  
7
cycles (mechanical)  
5
Frequency range: 0 – 20 kHz  
Low pulse width: Approx. 30 μsec.  
High level: 5 V ±10 %  
Low level: ≤ 0.5 V  
http://www.m-system.co.jp/  
10PR SPECIFICATIONS  
ES-0860 Rev.9 Page 2/3  
MODEL: 10PR  
EXTERNAL VIEW  
1
5
2
6
3
Sensitivity Adj.  
7
8
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)  
7–M3.5 SCREW  
8 (.31)  
2–4.3 (.17) dia.  
MTG HOLE  
TERMINAL COVER  
1
5
2
6
3
7
8
3 (.12)  
25 (.98)  
51 (2.01)  
130 (5.12)  
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
SENSITIVITY ADJ.  
Isolation  
*
Pulse Volt.  
Amplifier  
Output  
Driver  
+
1
2
3
7
8
5
6
+
Scaler  
One-Shot  
+7.5V  
INPUT  
OUTPUT  
OUTPUT  
POWER  
*Dry contact input only.  
Specifications are subject to change without notice.  
http://www.m-system.co.jp/  
10PR SPECIFICATIONS  
ES-0860 Rev.9 Page 3/3  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY