10JPA-20-R/C03 [MSYSTEM]
High-density Signal Conditioners 10-RACK;型号: | 10JPA-20-R/C03 |
厂家: | M-SYSTEM |
描述: | High-density Signal Conditioners 10-RACK |
文件: | 总3页 (文件大小:94K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MODEL: 10JPA
High-density Signal Conditioners 10-RACK
[1] INPUT
1: Open collector (Excitation: 12 V @ 30 mA)
2: Voltage pulse (Excitation: 12 V @ 30 mA)
3: Mechanical contact (Excitation: 12 V @ 30 mA)
FREQUENCY TRANSMITTER
(field-programmable)
Functions & Features
• Converting the output from a pulse-type transducer into
two standard process signals
[2] OUTPUT 1
Current
• Microprocessor based
A: 4 – 20 mA DC (Load resistance 600 Ω max.)
Voltage
• Field-programmable frequency range
• Linearization available for flow compensation
• Averaging non-uniform pulses
6: 1 – 5 V DC (Load resistance 500 Ω min.)
• Excitation
[3] OUTPUT 2
0: None
• Loop testing via hand-held programmer PU-2x
• Optional second channel output available at the front
terminals and at the Standard Rack connector
Voltage
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
Typical Applications
POWER INPUT
DC Power
• Positive displacement flowmeters, turbine flowmeters and
vortex flowmeters
R: 24 V DC
• Proximity switches
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
• Oval flowmeters
[4] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
RELATED PRODUCTS
• Programming Unit (model: PU-2x)
MODEL: 10JPA–[1][2][3]–R[4]
• PC configurator software (model: JXCON)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the
PC. Please refer to the internet software download site or
the users manual for the PC configurator for applicable
cable types.
ORDERING INFORMATION
• Code number: 10JPA-[1][2][3]-R[4]
Specify a code from below for each [1] through [4].
(e.g. 10JPA-2A6-R/Q)
• Frequency range (e.g. 0 – 152.3 Hz)
• Linearization data (max. 16 points)
Use Ordering Information Sheet (No. ESU-1673) to specify
linearization data when the I/O signals are non-linear.
• Specify the specification for option code /Q
(e.g. /C01)
GENERAL SPECIFICATIONS
Construction: Rack-mounted; terminal access via screw
terminals at the front and via card-edge connector at the
rear; terminal cover provided
Connection
Note: Consult factory on applications with a sensor handling
periodically (& quickly) changing frequency (e.g. oval
flowmeter).
Input: M3.5 screw terminals (torque 0.8 N·m)
Output: Card-edge connector and M3.5 screw terminals
(torque 0.8 N·m)
Power input: Supplied from card-edge connector
http://www.m-system.co.jp/
10JPA SPECIFICATIONS
ES-0873 Rev.11 Page 1/3
MODEL: 10JPA
Screw terminal: Nickel-plated steel
Line voltage effect: ±0.1 % over voltage range
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Overrange output: -10 – +120 % at 1 – 5 V
(0 – 120 % when 0 % input equals to 0 Hz.)
Linearization: 16 points max. represented as percentage of
full-scale
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 500 V AC @ 1 minute
(input to output 1 to output 2 to power)
1500 V AC @ 1 minute (input or output or power to ground)
Adjustments: Programming Unit (model: PU-2x); input
range, low-end cutout, zero and span, simulating output,
averaging nonuniform pulses, linearization data, etc.
(Refer to the users manual of JXCON for the adjustments
configurable with JXCON.)
Low-end cutout: 0 – 100 % adjustable (factory set to 0 %);
hysteresis fixed to 1 %
INPUT SPECIFICATIONS
Excitation: 12 V DC @30 mA; shortcircuit protection
Pulse width (time) requirement: 10 msec. min. at
< 20 Hz; duty ratio 20 – 80 % at ≥ 20 Hz
Offset: Max. 3 times span
■ Open Collector
Frequency range: 0 – 0.01 Hz through 25 kHz
(0 – 1 kHz will be used if not otherwise specified)
Sensing: Approx. 12 V DC @ 3 mA
ON/OFF level: ≤ 800 Ω / 2 V for ON,
≥ 1.2 kΩ / 3.6 V for OFF
■ Mechanical Contact
Frequency range: 0 – 0.01 Hz through 5 Hz
(0 – 5 Hz will be used if not otherwise specified)
Sensing: Approx. 12 V DC @ 3 mA
ON/OFF level: ≤ 800 Ω / 2 V for ON,
≥ 1.2 kΩ / 3.6 V for OFF
■ Voltage Pulse: Square or sine waveforms
Frequency range: 0 – 0.01 Hz through 25 kHz
(0 - 1 kHz will be used if not otherwise specified.)
Input amplitude: 2 – 50 Vp-p
Input impedance: 10 kΩ min.
INSTALLATION
Current consumption: Approx. 60 mA with voltage output 1
Approx. 90 mA with current output 1
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Standard Rack 10BXx
Weight: 220 g (0.49 lb)
PERFORMANCE in percentage of span
Accuracy: ±0.1 % with segment gain ≤ 1 [±0.1 % × gain]
with segment gain > 1
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
Response time: 0.5 sec. + 1 pulse cycle (0 – 90 %)
http://www.m-system.co.jp/
10JPA SPECIFICATIONS
ES-0873 Rev.11 Page 2/3
MODEL: 10JPA
DIMENSIONS unit: mm (inch)
7–M3.5 SCREW
8 (.31)
2–4.3 (.17) dia.
MTG HOLE
TERMINAL COVER
1
5
2
6
3
7
8
3 (.12)
25 (.98)
51 (2.01)
130 (5.12)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
Isolation
Waveform
Shaper
Digital
Computation
Output
Driver
+
–
1
2
3
7
8
+
INPUT
OUTPUT 1
OUTPUT 2
–
*
SENSOR EXCITATION
+
Z
S
12V Supply
Output
Driver
5
6
+
–
MODULAR JACK
PU-2x
SERIAL TRANSMISSION LINE
OUTPUT 2**
POWER
* 4kΩ attached for open collector and mechanical contact input only.
**1 output type has the output 1 connected to the card-edge connector in parallel.
Remark 1) The section enclosed by broken line is only for 2nd output channel.
Specifications are subject to change without notice.
http://www.m-system.co.jp/
10JPA SPECIFICATIONS
ES-0873 Rev.11 Page 3/3
相关型号: