Features  
Digital video signals over fiber optic links  
Wide protocol support with 143 Mbps to 1.485 Gbps data rates  
HD-SDI  
- SMPTE 292M (1.4835 Gbps NTSC, 1.485 Gbps PAL/SECAM)  
SDI  
- SMPTE 259M (143/270/360 Mbps)  
- SMPTE 344M (540 Mbps)  
DVB ASI (270 Mbps)  
75 Ohm coaxial input/output with standard BNC connector  
Front panel LED support for signal lock and CRC/EDH error  
Plug-n-Play operation  
SFP MSA (as applicable)  
Advantages  
Enables uncompressed digital video component signal  
transport over any standard optical transport system  
Supports standard, MSA compliant optical transceivers  
Supports digital video links over fiber optic cabling to  
distances of 120 km or more  
Overview  
MRV’s digital video SFPs are the industry’s first solution designed to affordably transmit digital video component  
signals over fiber using standard optical transceivers. Compatible with any optical transport system – WDM platforms,  
digital cross-connects, etc. – these unidirectional digital video SFPs open a new world of cost-effective digital video  
deployment options.  
- Link extension over new or existing fiber plant  
- Wave Division Multiplexing (CWDM and DWDM)  
- Link redundancy for mission critical applications  
- Video distribution/multicasting  
... and more!  
SDI, HD-SDI, and DVB are the basic standards employed in the transport of serial component digital video data on  
single coaxial cable. Using coaxial cable between the signal source and destination limits the link range to 350 meters,  
or to 140 meters for high definition. This distance is generally adequate for intra-building or small campus networks.  
However, the advent of geographically dispersed studio campuses requires more and more digital video data to travel  
across the sophisticated optical infrastructure of the metro and inter-metro network. Links of 100 kilometers or more  
and the use of WDM technology are increasingly common. Merging digital video traffic onto these optical transport  
networks is further complicated by the encoding methods for these protocols.  
1
Datasheet  
Digital video signaling includes a data scrambling algorithm for SDI and HD-SDI that is not easily transported over  
a standard optical transport system. This algorithm can produce a signal pattern that causes an error in standard  
optical systems. With a certain pattern in the video data, the scrambling algorithm can generate a pathological  
signal containing a series of up to 19 bits of the same polarity.  
These pathological patterns are not transportable over optical transport systems that employ “off the shelf”  
optical components. These components are generally designed to use an AC-balanced signal with a duty cycle of  
approximately 50%. That allows the optical transceiver to properly modulate the laser control loop (transmit side)  
and lock (PLL circuitry) its receiver.  
Until now, the industry has addressed this problem by providing optical components specifically designed for use  
with the pathological signaling of digital video: typically DC-coupled optical transceivers. This approach requires  
customized transceivers for each combination of distance, wavelength, and fiber type (multi-mode or single-mode)  
used. Specialized solutions must also be built for WDM applications. Such designs are purely proprietary, and  
therefore tend to be expensive. Unfortunately, DC-coupled transceivers generally have up to 8 dB lower receive  
sensitivity than AC-coupled components, and they cannot be amplified in a DWDM application. This sensitivity  
loss reduces link range by as much as 35 kilometers.  
In contrast to the situation with digital video specialty components, the optical Multi-Source Agreement (MSA) has  
led to a ready supply of inexpensive optical interfaces for most applications. However, the specific digital video  
solutions cannot use this huge selection of standard and affordable optical components. The general-purpose  
type of optical transport platform (multi-rate/multi-protocol transponder or repeater) simply cannot handle digital  
video.  
Video Extension Over Fiber  
Post Production  
Film Studio  
Facility  
Data Direction  
Digital Video over Coax  
Digital Video over Coax  
(0-350 m)  
SDI SFP  
(0-350 m)  
FO SFP  
FO SFP  
Data Direction  
Fiber Optic SDI Link  
0-120+ km  
Data Direction  
The SFP-CXASI-RX, here mounted in a Fiber  
Driver EM316DMR3G-3R, receives  
unidirectional SDI signal from a connected  
video device. The SDI signal is then  
transmitted over fiber via a standard SFP  
optical transceiver.  
The optical SFP transceiver on the other  
side of the fiber link receives the SDI data  
signal. The EM316DMR3G-3R (Dual Multi-  
rate Transponder) passes the SDI signal to  
the SFP-CXASI-TX, and delivers it to the  
end point video device.  
a
2
Datasheet  
HD-SDI:  
The new MRV digital video SFPs offer a direct and affordable solution to the problems of digital video optical  
transport. They allow the transport of SDI, HD-SDI, or DVB ASI component video signals over any optical transport  
system that employs MSA standard optical transceivers.  
The SFPxMRHDSDI-RXR SFP is a unidirectional multi-rate coaxial receiver designed to support digital video signals  
as defined by the SDI and HD-SDI standards. It takes the digital video stream and generates a data signal that  
is compatible with any standard optical transport system. The signal is passed through the system to an MSA  
standard optical transceiver, and transports it over a fiber optic network.  
At the end of the transmission link, the signal is received by another MSA standard transceiver and passed to the  
SFPxMRHDSDI-TXR.  
The SFPxMRHDSDI-TXR, in turn, processes the data signal and sends the resulting digital video stream to the  
receiving digital video device.  
The HDSDI products support main video systems (NTSC and PAL) currently in use. The multi-rate digital video SFP  
supports either NTSC or PAL standards for standard definition and high definition.  
CXDV:  
The CXDV SFPs support SD digital video at 270 Mbps, but they do not support 1.5 Gbps.  
CXASI:  
The SFP-CXASI-xxR SFP is designed to support digital video signals that do not contain pathological patterns.  
Contact your nearest authorized MRV representative and visit our website at www.mrv.com for more information  
on the complete line of MRV solutions, including pricing and availability.  
General Specifications  
Coaxial Interface:  
Input/Output Connector  
Impedance  
Transmitter  
Receiver  
BNC (x1)  
BNC (x1)  
75 Ohms (output)  
800 mV  
75 Ohms (input)  
N/A  
Output Level  
SFP Interface  
Complies to SFP MSA standard  
Complies to SFP MSA standard  
Performance:  
CRC/EDH Error Rate  
CRC/EDH Alarm¹  
Status and Control Signals:  
RX LOS  
Better than 10-9  
Better than 10-9  
Digital Diagnostics LED/SNMP trap status  
Digital Diagnostics LED/SNMP trap status  
N/A  
Yes  
Yes  
Yes  
TX Disable  
Temperature Range:  
Operating  
-5 to 50º C  
-5 to 50º C  
Storage  
-40 to 85º C  
850 mA @ 3.3 V  
-40 to 85º C  
850 mA @ 3.3 V  
Power Consumption:  
Agency Compliance:  
FCC Part 15, EMC Directive,WEEE Directive, RoHS, China RoHS, SFP MSA (as applicable)  
¹ Not available in CXASI models  
3
Datasheet  
SFPxMRHDSDI-RX serial cable input properties:  
Automatic cable equalization  
- up to 140 m of Belden 1694A at 1.485 Gbps and 1.485/1.001 Gbps  
- up to 350 m of Belden 694 A at 270 Mbps  
Tolerates > 20 dB cable loss at half clock frequency  
SFP-CXASI-RX and SFP-CXDV-RX27 serial cable input properties:  
Automatic cable equalization  
- up to 350 m of Belden 1694 A at 270 Mbps  
Tolerates > 20 dB cable loss at half clock frequency  
Other  
Specifications  
SFP5MRHDSDI  
(TX and RX)  
SFP3MRHDSDI  
(TX and RX)  
SFP-CXDV  
(TX and RX)  
SFP-CXASI  
(TX and RX)  
Standards  
SMPTE 259 M (270 Mbps) and  
SMPTE 292 M (1.485 Gbps)  
SMPTE 259 M (270 Mbps) and  
DVB ASI (270 Mbps)  
DVB ASI (270 Mbps)  
SMPTE 292 M (1.485/1.001 Gbps)  
Supported Frame &  
Refresh Rates  
720 x 486i  
720 x 486i  
720 x 486i  
720 x 576i  
720 x 486i  
720 x 576i  
720 x 576i  
720 x 576i  
1280 x 720p (60hz)  
1920 x 1035i (60hz)  
1920 x 1080sF (24hz)  
1920 x 1080p (24hz)  
1920 x 1080i (50hz)  
1920 x 1080p (25hz)  
1920 x 1080i (60hz)  
1920 x 1080p (30hz)  
1280 x 720p (59.94hz)  
1920 x 1035i (59.94hz)  
1920 x 1080sF (23.98hz)  
1920 x 1080p (23.98hz)  
1920 x 1080i (59.94hz)  
1920 x 1080p (29.97hz)  
The HDSDI SFPs are designed to pass SMPTE-compliant digital streams, both standard and high-definition, with no  
errors. Non-compliant streams with serious TRS errors may cause momentary dropouts in the video picture.  
4
Datasheet  
Ordering Information (use in pairs as shown)  
Unidirectional SDI/  
SFP5MRHDSDI-TX  
270 Mbps/1.485  
Gbps  
HD-SDI SFP Transmitter  
BNC  
BNC  
BNC  
BNC  
75  
75  
75  
75  
800  
-
(PAL/SECAM)  
Unidirectional SDI/  
HD-SDI SFP Receiver  
(PAL/SECAM)  
270 Mbps/1.485  
Gbps  
300 @270 Mbps  
140 @1.485 Gbps  
SFP5MRHDSDI-RX  
SFP3MRHDSDI-TX  
SFP3MRHDSDI-RX  
-
800  
-
Unidirectional SDI/  
HD-SDI SFP Transmitter  
(NTSC)  
270 Mbps/  
1.485/1.001 Gbps  
-
Unidirectional SDI/  
HD-SDI SFP Receiver  
(NTSC)  
270 Mbps/  
1.485/1.001 Gbps  
300 @270 Mbps  
140 @1.4835 Gbps  
Unidirectional Digital  
Video SDI SFP Transmitter  
SFP-CXDV-TX27  
SFP-CXDV-RX27  
SFP-CXASI-TX  
SFP-CXASI-RX  
270 Mbps  
270 Mbps  
270 Mbps  
270 Mbps  
BNC  
BNC  
BNC  
BNC  
75  
75  
75  
75  
800  
-
Unidirectional Digital  
Video SDI SFP Receiver  
-
800  
-
350  
-
Unidirectional DVB-ASI  
SFP Transmitter  
Unidirectional DVB-ASI  
SFP Receiver  
350  
AVAILABLE BY SPECIAL ORDER  
Ordering Information (use in pairs as shown)  
Unidirectional Digital Video  
SDI SFP Transmitter  
SFP-3654-SDI-TX  
SFP-3654-SDI-RX  
360/540 Mbps  
360/540 Mbps  
BNC  
BNC  
75  
75  
800  
-
-
Unidirectional Digital Video  
SDI SFP Receiver  
275 @360 Mbps  
200 @540 Mbps  
ꢀ Distances may vary based on properties of the transponder.  
MRV has more than 50 offices throughout the world. Addresses, phone numbers and fax numbers are listed at www.mrv.com.  
Please e-mail us at sales@mrv.com or call us for assistance.  
MRV Los Angeles  
20415 Nordhoff St.  
Chatsworth, CA 91311  
800-338-5316  
MRV Boston  
295 Foster St.  
Littleton, MA 01460  
800-338-5316  
MRV International  
Business Park Moerfelden  
Waldeckerstrasse 13  
64546 Moerfelden-Walldorf  
Germany  
818-773-0900  
978-952-4700  
Tel. (49) 6105/2070  
Fax (49) 6105/207-100  
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the  
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.  
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.  
MRV-OP-SDISFP-120808  
3020015-001 Rev. B1  
Copyright ©2008 MRV Communications, Inc. All Rights Reserved.  

相关型号:

SFP-3711

20 GE PoE-Plus plus 4 GE PoE-Plus Combo SFP plus 4 10GE SFP-Plus L2-Plus Managed Switch, 185W
LevelOne

SFP-4200

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4210

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4240

Modularized 24 10/100 plus 4 GE Combo SFP Managed Switch -40 to 75C, IEC61850
LevelOne

SFP-4270

Modularized 24 10/100 plus 4 GE Combo SFP Managed Switch -40 to 75C, IEC61850
LevelOne

SFP-4310

16 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4320

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4330

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4340

12 x 802.3at plus 2GE SFP Combo Unmanaged Switch -40 to 75C
LevelOne

SFP-4350

12 x 802.3at plus 2GE SFP Combo Unmanaged Switch -40 to 75C
LevelOne

SFP-4360

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne

SFP-4370

8 FE plus 2 GE Combo SFP Managed Switch -40 to 75C, DIN-rail, IEC61850
LevelOne