NC316BU-1-NP [MRV]
Fiber Driver® Chassis; 光纤Driver®机箱型号: | NC316BU-1-NP |
厂家: | MRV COMMUNICATIONS, INC. |
描述: | Fiber Driver® Chassis |
文件: | 总4页 (文件大小:81K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Media Converters
Repeaters and Optimizers
Datasheet
Fiber Driver® Chassis
FD
Features
Models with 1, 2, 3, 4, or 16 slots
Rack mounting options ¹
Wall mounting options ²
Module flexibility; no slot dependency within a chassis
Hot-swap support
Management module compatibility ³
- fan status
- power supply status
- temperature status
- high and low temperature limits
- SNMP traps to report faults
Overview
The Fiber Driver® chassis is the foundation for deploying and managing
the Fiber Driver media module product family. Chassis are available with
one, two, three, four, and sixteen slots.
AC or DC redundant power supply pairs
Optional front cable management tray for NC316BU-16
chassis
The three-slot (NC316BU-3), four-slot (NC316BU-4 and NC316BU-4S),
sixteen-slot (NC316BU-16) and sixteen-slot Telco (NC316BU-16T) chassis
can be equipped with redundant, hot-swappable AC or DC internal
power supplies.The two-slot NC316BU-2 and one-slot NC316BU-1 come
with a single AC or DC internal power supply.
The NC316BU-1/NP and NC316BU4PMC/NP chassis are designed to
host fully passive modules such as the Fiber Driver Splitter/Combiner.
Because fully passive solutions require no external power source, these
chassis include no power supply.
¹ three-slot, four-slot, and sixteen-slot models
² one-slot and two-slot models
³ two-slot, three-slot, four-slot, and sixteen-slot
chassis models
ONE-SLOT CHASSIS
SIXTEEN-SLOT CHASSIS
THREE-SLOT CHASSIS
FOUR-SLOT CHASSIS
TWO-SLOT CHASSIS
SIXTEEN-SLOT TELCO 23” CHASSIS
sales@mrv.com
Media Converters
Repeaters and Optimizers
Chassis with two, three, four and sixteen slots can
accommodate network management module.
EM316NM and EM316LNXNM-OT provide monitoring of
system temperature, fan status, and power supply.
The one-slot chassis is suitable for unmanaged use in
standalone applications. The NC316BU-2 is designed for
single-module managed and two-module unmanaged
standalone applications.
a
The NC316BU-4, NC316BU-4S, and NC316BU-16 mount in
19”racks.The NC316BU-3 and NC316BU-16T,have reduced
depth form-factors and front-loaded power supplies for
Telco installations. These models mount in 23” racks, and
the NC316BU-3 can also mount in 19”racks.
Contact your nearest MRV representative for information
on Fiber Driver or other products.
REDUNDANT POWER SUPPLIES
Model
Description
NC316-3RPSAC
NC316-3RPSDC
NC316-4RPSAC
NC316-4RPSDC
NC316BU-4SRPSAC
NC316BU-4SRPSDC
NC316-16RPSAC
NC316-16RPSDC
NC316-16T/DC
Redundant Power Supply for NC316BU-3/AC
Redundant Power Supply for NC316BU-3/DC
Redundant Power Supply for NC316BU-4/AC
Redundant Power Supply for NC316BU-4/DC
Redundant Power Supply for NC316BU-4S/AC
Redundant Power Supply for NC316BU-4S/DC
Redundant Power Supply for NC316BU-16/AC
Redundant Power Supply for NC316BU-16/DC
Redundant Power Supply for NC316BU-16T/DC
ACCESSORIES
Model
Description
NC316RB23-3
NC316RB23-4
NC316-16BRACKET
NC316RB23-16
NC316MB-1
Rack Mount Bracket for NC316BU-3/AC or -3/DC Telco Chassis; 23”
Rack Mount Bracket for NC316BU-4/AC or -4/DC Telco Chassis; 23”
Rack Mount Bracket for 16-slot Chassis
Rack Mount Bracket for NC316BU-16/AC Chassis, 23”
Wall Mount Bracket for NC316BU-1
NC316MB-2
Wall Mount Bracket for NC316BU-2
NC316BP-1
Blank Panel, Single-Slot Wide, for NC316BU
NC316BP-4
Blank Panel, Four-Slot Wide, for NC316BU-16
NC316DCC
DC Power Female Connector (WAGO)
NC316BU-16CMT
NC316-16DOOR
Cable Management Tray for the NC316BU-16 Chassis
Cable Management Tray and transparent door for the NC316BU-16 Chassis
sales@mrv.com
Media Converters
Repeaters and Optimizers
CHASSIS
Model
Description
Physical Dimensions (hight x width x depth)
Weight
NC316BU-1/AC
NC316BU-1/DC
One-slot, AC power
One-slot, DC power
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
1.0 kg (2.2 lbs)
1.0 kg (2.2 lbs)
1.0 kg (2.2 lbs)
1.0 kg (2.2 lbs)
1.0 kg (2.2 lbs)
NC316BU-1/AC/EU One-slot,VAC power (European version)
NC316BU-1HP/AC One-slot, AC power
NC316BU-1HP/DC One-slot, DC power
One-slot, no power supply (passive
application only)
NC316BU-1/NP
38 mm x 159 mm x 199 mm (1.50”x 6.26”x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-2/AC
NC316BU-2/DC
NC316BU-3/AC
NC316BU-3/DC
NC316BU-4/AC
NC316BU-4/DC
NC316BU-4S/AC
NC316BU-4S/DC
Two-slot, AC power
65 mm x 159 mm x 197 mm (2.56”x 6.26”x 7.75”)
65 mm x 159 mm x 197 mm (2.56”x 6.26”x 7.75”)
44 mm x 439 mm x 203 mm (1.73”x 17.28”x 7.99”)
44 mm x 439 mm x 203 mm (1.73”x 17.28”x 7.99”)
44 mm x 439 mm x 434 mm (1.73”x 17.28”x 17.09”)
44 mm x 439 mm x 434 mm (1.73”x 17.28”x 17.09”)
44 mm x 439 mm x 305 mm (1.73”x 17.28”x 12.00”)
44 mm x 439 mm x 305 mm (1.73”x 17.28”x 12.00”)
1.4 kg (3.1 lbs)
1.4 kg (3.1 lbs)
3.1 kg (6.8 lbs)
3.0 kg (6.6 lbs)
7.7 kg (17.0 lbs)
7.7 kg (17.0 lbs)
4.5 kg (9.9 lbs)
4.5 kg (9.9 lbs)
Two-slot, DC power
Three-slot Telco, for19”rack, AC power
Three-slot Telco, for19”rack, DC power
Four-slot, for 19”rack, AC power
Four-slot, for 19”rack, DC power
Four-slot, for 19”rack, AC power
Four-slot, for 19”rack, DC power
Non-managed, non-powered four-slot
chassis for passive Mux/Demux modules
NC316BU4PMC/NP
44 mm x 441 mm x 286 mm (1.73”x 17.36”x 11.26”)
4.3 kg (9.6 lbs)
NC316BU-16/AC
NC316BU-16/DC
NC316BU-16T/DC
Sixteen-slot, for 19”rack, AC power
Sixteen-slot, for 19”rack, DC power
Sixteen-slot Telco, for 23”rack, DC power
110 mm x 439 mm x 408 mm (4.33”x 17.28”x 16.06”) 8.8 kg (19.4 lbs)
110 mm x 439 mm x 408 mm (4.33”x 17.28”x 16.06”) 8.7 kg (19.2 lbs)
132 mm x 541 mm x 254 mm (5.20”x 21.30”x 10.00”) 8.2 kg (18.1 lbs)
sales@mrv.com
Media Converters
Repeaters and Optimizers
POWER SUPPLY SPECIFICATIONS
Nominal Input
Range (VAC)
Input Range
(VDC)*
Maximum
Rating (Amps)
Operating
Temperature
Storage
Temperature
Relative
Humidity
Model
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
NC316BU-1/AC
100 - 240 @ 50/60 Hz
-
0.3
-35 to +60°C -35 to +70°C
(-31 to +140°F) (-31 to +158°F) non condensing
< 85%
NC316BU-1/DC
-
40.5 - 57
0.5
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
NC316BU-1/AC/EU
NC316BU-1HP/AC
NC316BU-1HP/DC
NC316BU-2/AC
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C -20 to +70°C
(+32 to +122°F) (0 to +154°F)
-40 to +65°C -45 to +75°C
< 85%
non condensing
100 - 240 @ 50/60 Hz
-
0.3
< 85%
-
40.5 - 57
0.5
(-40 to +149°F) (-49 to +167°F) non condensing
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
100 - 240 @ 50/60 Hz
-
0.6
-35 to +60°C -35 to +70°C
(-31 to +140°F) (-31 to +158°F) non condensing
< 85%
NC316BU-2/DC
-
40.5 - 57
1.0
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
NC316BU-3RPSAC
NC316BU-3RPSDC
NC316BU-4RPSAC
NC316BU-4RPSDC
100 - 240 @ 50/60 Hz
-
1.6
-35 to +60°C -35 to +70°C
(-31 to +140°F) (-31 to +158°F) non condensing
< 85%
-
40.5 - 57
2.0
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
100 - 240 @ 50/60 Hz
-
-
4.0
-35 to +60°C -35 to +70°C
(-31 to +140°F) (-31 to +158°F) non condensing
< 85%
40.5 - 57
-
2.0
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
NC316BU-4SRPSAC 100 - 240 @ 50/60 Hz
NC316BU-4SRPSDC
NC316BU-16RPSAC 100 - 240 @ 50/60 Hz
1.8
-35 to +60°C -35 to +70°C
(-31 to +140°F) (-31 to +158°F) non condensing
< 85%
-
40.5 - 57
-
2.0
0 to +50°C
(+32 to +122°F) (0 to +154°F)
-20 to +70°C
< 85%
non condensing
3.5
-35 to +60°C -35 to +70°C
< 85%
NC316BU-16RPSDC
NC316BU-16T/DC
-
-
40.5 - 57
40.5 - 57
5.0 or 6.5
5.0
(-31 to +140°F) (-31 to +158°F) non condensing
-35 to +60°C -35 to +70°C < 85%
(-31 to +140°F) (-31 to +158°F) non condensing
* Compliant with ANSI TI.315-1994 standard
Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking;
TUV CUE Mark (Canada, USA, EU); GOST (selected products); RoHS Directive,WEEE Directive:Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick
(selected products). Contact your sales representative for details.
MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com.
Please e-mail us at sales@mrv.com or call us for assistance.
MRV (West Coast USA)
20415 Nordhoff St.
Chatsworth, CA 91311
800-338-5316
MRV (East Coast USA)
295 Foster St.
Littleton, MA 01460
800-338-5316
MRV (International)
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
818-773-0900
978-952-4700
Tel. (49) 6105/2070
Fax. (49) 6105/207-100
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness
thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications
logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
Copyright ©2006 MRV Communications, Inc. All Rights Reserved.
MRV-FD-CHASS-120506
1398005-001 Rev. B
相关型号: