ADC223 [MPSIND]
1W, High Isolation SIP, Single & Dual Output DC/DC Converters; 1W ,高隔离SIP ,单和双输出DC / DC转换器型号: | ADC223 |
厂家: | MPS INDUSTRIES, INC. |
描述: | 1W, High Isolation SIP, Single & Dual Output DC/DC Converters |
文件: | 总2页 (文件大小:170K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Selection Guide
Model
Number
Input
Voltage
Output
Voltage
Output
Current
mA
Efficiency
Load
Regulation
VDC
VDC
3.3
5
% Typ.
73
71
76
78
78
72
77
78
79
74
73
78
80
80
74
79
81
81
73
71
76
78
79
72
76
79
80
% Max.
260
200
110
84
ADC201
ADC202
ADC203
ADC204
ADC205
ADC206
ADC207
ADC208
ADC209
ADC211
ADC212
ADC213
ADC214
ADC215
ADC216
ADC217
ADC218
ADC219
ADC221
ADC222
ADC223
ADC224
ADC225
ADC226
ADC227
ADC228
ADC229
10
10
8
9
12
15
±5
±9
±12
±15
3.3
5
7
5
67
7
(4.5 – 5.5)
±100
±56
±42
±34
260
200
110
84
10
8
7
7
8
Key Features
8
9
5
• Efficiency up to 81%
• 3000VDC Isolation
• MTBF > 2,000,000 Hours
• Low Cost
• Input 5, 12 and 24VDC
• Output 3.3, 5, 9, 12, 15,
±5, ±9, ±12 and ±15VDC
• Temperature Performance
-40°C to +85°C
• UL 94V-0 Package Material
• Internal SMD Construction
• Industry Standard Pinout
12
15
±5
±9
±12
±15
3.3
5
5
12
67
5
(10.8 – 13.2)
±100
±56
±42
±34
260
200
110
84
8
5
5
5
8
8
9
5
12
15
±5
±9
±12
±15
5
24
67
5
(21.6 – 26.4)
±100
±56
±42
±34
8
5
5
5
MPS Industries ADC200 1W
DC/DC's are specially designed
to provide high levels of isolation
3000VDC in a miniature SIP
package.
Mechanical Dimensions
Pin Connections
Pin
Singles
Duals
+Vin
-Vin
-Vout
Common
+Vout
19.5 [0.77]
1
+Vin
2
-Vin
5
6
7
-Vout
No Pin
+Vout
The series consists of 27 models
with input voltages of 5V, 12V and
24VDC which offers standard output
voltages of 3.3V, 5V, 9V, 12V, 15V,
±5V, ±9V, ±12V and ±15VDC for a
wide choice.
Case Size –
5V & 12V Input – 19.5x6.1x10.2mm
(0.77x0.24x0.40inch)
24V Input –19.5x7.1x10.2mm
2.54 [0.100]
2.1 [0.08]
18.5 [0.73]
(0.77x0.28x0.40inch)
Case Material –
Non-Conductive Black Plastic
Weight –
The ADC200 series is an excellent
selection for a variety of applications
including distributed power
systems, mixed analog/digital
subsystems, portable test
1
2
5
6
7
5V & 12V Input – 2.2g (0.08Oz)
24V Input– 2.6g (0.09Oz)
0.50 [0.020]
Tolerance
Pin
Millimeters
X.X±0.25
Inches
X.XX±0.01
equipments, local power networks
and battery backed systems.
T= 6.1 (0.24) for 5V & 12V Input Models
T= 7.1 (0.28) for 24V Input Models
X.XX±0.13
X.XXX±0.005
±0.05
±0.002
2463 208th Street, Ste. 205
Torrance, CA 90501
Tel: (310) 533-1455
Fax: (310) 533-1853
http://www.mpsind.com
E-mail: sales@mpsind.com
ADC200 SERIES
1W, High Isolation SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
General Characteristics
Parameter
Parameter
Conditions
Min. Max. Units
Min.
3000
Typ.
---
Max.
---
Units
VDC
Isolation
Voltage
60 Seconds
5VDC Input Models
-0.7
9
VDC
Isolation
Resistance
Input Surge Voltage
12VDC Input Models
500VDC
-0.7
18
VDC
10
---
70
---
60
---
GΩ
pF
(1000mS)
Isolation
Capacitance
100kHz, 1V
24VDC Input Models
-0.7
30
VDC
100
120
Lead Temperature
(1.5mm from case for 10sec.)
Switching
Frequency
---
---
260
450
°C
100
kHz
Internal Power Dissipation
mW
MIL-HDBK-217F
@25°C
Ground Benign
MTBF
2
---
---
MHrs
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
Environmental Characteristics
Output Characteristics
Conditions
Parameter
Min.
---
Typ.
±1.2
Max.
±1.5
Units
%
Parameter
Conditions
Min. Max. Units
For Vin Change of
1%
Operating
Temperature
Ambient
-40
85
°C
Line Regulation
Operating
Temperature
Io = 20% to 100%
20MHz BW
See Selection Guide
Case
-40
90
°C
Load Regulation
%
Storage
Temperature
mV P-P
-40
---
125
95
°C
%
Ripple & Noise
Short Circuit
---
65
100
0.5 Second Max.
Humidity
Cooling
Free-Air Convection
Maximum Capacitive Load
Units
uF
Derating Curve (3.3, 5 & ±5V Outputs)
Singles
Duals
100
Models by Output Voltage
(Each Output on Duals)
220
100
100LFM
200LFM
400LFM
80
Natural
convection
Notes:
60
40
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
20
0
¡ã
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
-40
50
60
70
80
90
100
110
Ambient Temperature
]
Derating Curve (Other Outputs)
100
100LFM
400LFM
200LFM
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
80
60
Natural
convection
40
20
0
¡ã
-40
50
60
70
80
90
100
110
Ambient Temperature
]