MD248D-12RU [MPD]

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters;
MD248D-12RU
型号: MD248D-12RU
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters

文件: 总2页 (文件大小:444K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MD200RU Series  
Wide 4:1 Input, 2W SIP  
Single & Dual Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
Conditions  
Min.  
4.5  
9.0  
Typ.  
12.0  
24.0  
48.0  
4.0  
Max.  
18.0  
36.0  
75.0  
4.5  
9.0  
18.0  
4.0  
Units  
2W Output Power  
Miniature SIP Case  
Wide 4:1 Input Range  
Single & Dual Outputs  
12 VDC Input  
24 VDC Input  
48 VDC Input 18.0  
12 VDC Input  
24 VDC Input  
48 VDC Input  
12 VDC Input  
24 VDC Input  
48 VDC Input  
Input Voltage Range  
VDC  
3.0  
4.5  
8.5  
Startup Threshold Voltage  
Under Voltage Shutdown  
6.0  
12.0  
VDC  
1,500 VDC Isolation  
>1.0 MHour MTBF  
8.0  
16.0  
1,500  
VDC  
mW  
21 Standard Models  
Industry Standard Pin-Out  
Short Circuit Input Power  
Input Filter  
Internal Capacitor  
Output  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
2.0  
2.0  
0.5  
1.0  
100  
500  
5.0  
Units  
%
%
%
%
mV P - P  
mSec  
%
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
1.0  
0.3  
0.5  
VIN = Min to Max  
IOUT = 0% to 100%  
See Note 1  
Load Regulation  
Ripple & Noise (20 MHz)  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
300  
3.0  
0.01  
See Note 2  
0.02  
%/ºC  
Continuous (Autorecovery)  
Parameter  
Isolation Voltage  
Conditions  
Min.  
Typ.  
Max.  
Units  
VDC  
M  
pF  
kHz  
60 Seconds 1,500  
500 VDC 1,000  
100 kHz, 1V  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling, See Note 3  
Humidity  
250  
300  
500  
Conditions  
Min.  
Ambient -40  
Case  
Typ.  
+25  
Max.  
+75  
+105  
+125  
Units  
ºC  
ºC  
-55  
ºC  
Free Air Convection  
RH, Non-condensing  
95  
%
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
MTBF  
Absolute Maximum Ratings  
Parameter  
See Mechanical Drawing (Page 2)  
Non-Conductive Black Plastic (UL94-V0)  
0.07 Oz (2.1g)  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Conditions  
MIL HDBK 217F, 25ºC, Gnd Benign  
Min.  
2.8  
Typ.  
Typ.  
Max.  
Units  
MHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
Min.  
Max.  
25  
50  
100  
260  
Units  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
VDC  
Lead Temperature  
1.5 mm From Case For 10 Sec  
ºC  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Fuse  
Rating  
Input  
Output  
Capacitive  
Load  
Model  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Number  
Current (mA)  
Voltage Current  
Current  
(mA, Min)  
Slow-Blow  
F, Max)  
(VDC)  
(mA, Max)  
Nominal  
12  
Range  
Full-Load No-Load  
(mA)  
MD212S-03RU  
MD212S-05RU  
MD212S-12RU  
MD212S-15RU  
MD212D-05RU  
MD212D-12RU  
MD212D-15RU  
MD224S-03RU  
MD224S-05RU  
MD224S-12RU  
MD224S-15RU  
MD224D-05RU  
MD224D-12RU  
MD224D-15RU  
MD248S-03RU  
MD248S-05RU  
MD248S-12RU  
MD248S-15RU  
MD248D-05RU  
MD248D-12RU  
MD248D-15RU  
4.5 - 18.0  
4.5 - 18.0  
4.5 - 18.0  
4.5 - 18.0  
4.5 - 18.0  
4.5 - 18.0  
4.5 - 18.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
9.0 - 36.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
18.0 - 75.0  
183  
208  
204  
204  
208  
202  
204  
92  
60  
60  
60  
60  
60  
60  
60  
30  
30  
30  
30  
30  
30  
30  
20  
20  
20  
20  
20  
20  
20  
3.3  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
500  
400  
167  
134  
200  
83  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
0.0  
75  
80  
82  
82  
80  
82  
82  
75  
80  
82  
82  
80  
82  
82  
74  
80  
82  
82  
80  
82  
82  
1,000  
1,000  
170  
110  
470  
100  
470  
1,000  
1,000  
170  
110  
470  
100  
470  
1,000  
1,000  
170  
110  
470  
500  
500  
500  
500  
500  
500  
500  
250  
250  
250  
250  
250  
250  
250  
100  
100  
100  
100  
100  
100  
100  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
24  
48  
48  
48  
67  
500  
400  
167  
134  
200  
83  
104  
102  
102  
104  
101  
102  
46  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
3.3  
67  
500  
400  
167  
134  
200  
83  
52  
51  
51  
52  
51  
51  
5.0  
12.0  
15.0  
5.0  
12.0  
15.0  
48  
48  
48  
48  
100  
470  
67  
Notes:  
Derating Curve  
1. When measuring output ripple & noise, it is recommended that an external  
ceramic capacitor (0.47 µF typ.) be placed from the +VOUT to the -VOUT pins for  
single output units and from each output to common for dual output models.  
2. Transient recovery is measured to within a 1% error band for a load step  
change of 75% to 100%.  
3. Free air convection is typically 20 LFM. The units should not be operated in  
still air (0 LFM).  
4. Exceeding the absollute ratings could damage the unit.  
5. It is recommended that a fuse be used on the input of a power supply for protection.  
See the Model Selection table above for the correct rating.  
Remote ON/OFF  
Mechanical Dimensions  
The MD200x-xxRU remote control input (pin 3) is current controlled. The unit oper-  
ates when this input is open. When the input is “high” (current is flowing into the  
pin), the converter shuts down. The input current to this pin should be kept between  
2 mA and 4 mA. The diagram above shows a simple connection for the control pin.  
Using a value of 1 kfor R1,a voltage level of 5V - 9V may be used to control the  
unit. The table below gives specifications for this feature.  
Remote On/Off  
Parameter  
Min.  
Open or High Impedance  
mA  
mA  
Typ.  
Max.  
Units  
Supply On  
Supply Off  
Standby Input Current  
2
4
2.5  
Pin Connections  
Pin  
Single  
Dual  
1
2
4
5
6
7
8
-VIN  
+VIN  
-VIN  
+VIN  
Remote ON/OFF Remote ON/OFF  
NC  
+VOUT  
-VOUT  
NC  
NC  
+VOUT  
Common  
-VOUT  
NC: No Connection  
Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.02 ( 0.50)  
Pin 1 is marked by a “dot” or indentation on the side of the unit  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

MD248D-15RU

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters
MPD

MD248S-03RU

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters
MPD

MD248S-05RU

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters
MPD

MD248S-12RU

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters
MPD

MD248S-15RU

Wide 4:1 Input, 2W SIP Single & Dual Output DC/DC Converters
MPD

MD24D12-833

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24D15-667

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24S1.5-6000

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24S12-1670

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24S15-1330

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24S2.5-6000

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL

MD24S3.3-5000

Up to 20 Watts DC/DC Power Converters Single and Dual Outputs
WALL