I1014RU [MPD]
Analog Circuit;型号: | I1014RU |
厂家: | MICROPOWER DIRECT, LLC |
描述: | Analog Circuit |
文件: | 总2页 (文件大小:339K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series
I1000RU
Ultra-Miniature 10W
Wide 4:1 Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 10W Output Power
• 4:1 Input Range
• Ultra- Miniature Case
• Remote On/Off Control
• 1,500 VDC Isolation
• >350 kHour MTBF
• Standard Pin-Out
Input
Parameter
Conditions
24 VDC Input
Min.
9.0
Typ.
24.0
48.0
Max.
36.0
75.0
9.0
18.0
8.5
Units
Input Voltage Range
Start-Up Voltage
VDC
48 VDC Input 18.0
24 VDC Input
48 VDC Input
24 VDC Input
48 VDC Input
VDC
VDC
Under Voltage Shutdown
17.0
Input Filter
(Pi) Filter, Meets EN55022 Class A
Output
Parameter
Conditions
Min.
Typ.
1.0
1.0
0.3
0.5
60
Max.
2.0
2.0
1.0
1.2
100
150
600
6.0
Units
%
%
%
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 15% to 100%
Ripple & Noise (20 MHz), See Note 1
mV P - P
Over Line, Load & Temperature
25% Load Step Change
Transient Recovery Time, See Note 2
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
300
3.0
150
0.01
µSec
%
%
110
0.02
%/ºC
Continuous (Autorecovery)
Parameter
Isolation Voltage
Conditions
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M
pF
kHz
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
1,500
450
Min.
Typ.
+25
Max.
+80
+100
+125
Units
ºC
ºC
Ambient
Case
-40
-50
ºC
Free Air Convection
See Curve
Derating
Humidity
RH, Non-condensing
95
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Physical
Case Size
Case Material
Weight
1.00 x 1.00 x 0.40 Inches (25.4 x 25.4 x 10.16 mm)
Six-Sided Shielded Aluminum With Non-Conductive Base (UL94-V0)
0.52 Oz (15g)
Reliability Specifications
Parameter
MTBF
Conditions
Min.
350
Typ.
Typ.
Max.
Units
kHours
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
MIL HDBK 217F, 25ºC, Gnd Benign
Absolute Maximum Ratings
Parameter
Conditions
Min.
Max.
50.0
100.0
260
Units
VDC
ºC
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
www.micropowerdirect.com
Input
Output
Capacitive Fuse Rating
Model
Number
Efficiency
Voltage (VDC)
Current (mA)
Load
Slow-Blow
(mA)
Voltage Current
Current
(mA, Min)
(%, Typ)
(µF Max)
(VDC)
(mA, Max)
Nominal
Range
Full-Load No-Load
I1001RU
I1002RU
I1003RU
I1004RU
I1005RU
I1006RU
I1007RU
I1011RU
I1012RU
I1013RU
I1014RU
I1015RU
I1016RU
I1017RU
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
9.0 - 36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
352
496
483
474
496
477
474
180
248
241
237
248
238
237
30
30
30
30
30
30
30
20
20
20
20
20
20
20
3.3
5.0
12.0
15.0
5.0
12.0
15.0
3.3
2,200
2,000
830
660
1,000
410
330
300
125
100
150
61
86
84
86
87
84
86
87
85
84
86
87
84
86
87
560
560
150
150
220
100
100
560
560
150
150
220
100
100
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
330
50
2,200
2,000
830
660
1,000
410
330
300
125
100
150
61
5.0
12.0
15.0
5.0
12.0
15.0
500
500
330
50
Notes:
1. Output ripple is measured with a 0.47 µF ceramic capcitor connected across the outputs.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. Operation at no-load will not damage the unit, but they may not
Pin Connections
Min
Max
2.5 VDC 50 VDC
0.0 VDC 1.0 VDC
0.5 mA
Pin Single
Dual
Pin
Single
Dual
meet all specifications.
On
Off
4. The On/Off Control input (Pin 3) is referenced to -Vin (Pin 2). If it is
not used, the control pin should be left open. If the pin is shorted to
-VIN, the unit will turn off.
1
2
3
+Vin
-Vin
Remote ON/OFF
+Vin
-Vin
4
5
6
+Vout
No Pin
-Vout
+Vout
Common
-Vout
In. Current (on)
In. Current (off)
6. It is recommended that a fuse be used on the input of a power
supply for
-0.5 mA
protection. See the Model Selection table above for the correct rating.
Mechanical Dimensions
Derating Curve - Without HeatSink
Mechanical Dimensions - With HeatSink
Derating Curve - With HeatSink
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
相关型号:
I107D-100JEY
Multifunction Peripheral, CMOS, PBGA503, 33 X 33 MM, 2.75 MM HEIGHT, 1.27 MM PITCH, LEAD FREE, FLIP CHIP, PLASTIC, BGA-503
IDT
©2020 ICPDF网 联系我们和版权申明