C4004ERW [MPD]

Compact, 2:1 Input 40W, Single Output DC/DC Converters; 结构紧凑, 2 : 1输入40W ,单输出DC / DC转换器
C4004ERW
型号: C4004ERW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Compact, 2:1 Input 40W, Single Output DC/DC Converters
结构紧凑, 2 : 1输入40W ,单输出DC / DC转换器

转换器
文件: 总2页 (文件大小:243K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
C4000ERWSeries  
Compact, 2:1 Input  
40W, Single Output  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Conditions  
12 VDC Input  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
Max.  
18.0  
36.0  
75.0  
9.0  
Units  
Key Features:  
40W Output Power  
2:1 Input Voltage Range  
1,500 VDC Isolation  
Compact 2 x 2 In. Case  
-40ºC to +60ºC Operation  
>1.0 MHour MTBF  
Input Voltage Range  
24 VDC Input 18.0  
48 VDC Input 36.0  
12 VDC Input  
24 VDC Input 16.0  
48 VDC Input 33.0  
(Pi) Filter  
VDC  
8.0  
Under Voltage Shutdown  
17.8  
36.0  
VDC  
A
Input Filter  
Start Up Time  
Output  
Parameter  
Output Voltage Accuracy  
Line Regulation  
See Note 1  
Conditions  
For Vin Min to Max  
2.0  
Remote ON/OFF  
Industry Standard Pin-Out  
Min.  
Typ.  
1.0  
0.2  
0.5  
75  
Max.  
Units  
%
%
%
mV P - P  
%
% Vout  
µSec  
%
Load Regulation  
Ripple & Noise (20 MHz) (Note 1)  
Output Power Protection  
Over Voltage Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
Iout = 10% to 100%  
150  
150  
130  
500  
5.0  
120  
110  
200  
25% Load Step Change  
0.02  
%/°C  
Continuous (Autorecovery)  
Parameter  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
Typ.  
Max.  
Units  
VDC  
M⍀  
pF  
kHz  
°C  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Over Temperature Protection  
Remote On/Off (Note 3)  
Parameter  
100 kHz, 0.1V  
2,000  
300  
115  
Case Temperature  
Conditions  
Min.  
3.5  
-0.0  
Typ.  
Max.  
12.0  
1.2  
Units  
VDC  
VDC  
mA  
Supply On  
Supply Off  
Standby Input Current  
Control Common  
Environmental  
Parameter  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
Humidity  
Physical  
Case Size  
Case Material  
1
Referenced to Negative Input (pin 2)  
Conditions  
Min.  
-40  
-55  
Typ.  
Max.  
+60  
+125  
Units  
°C  
°C  
Ambient  
Free Air Convection  
RH, Non-condensing  
95  
%
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
2.0 x 2.0 x 0.42 Inches (50.8 x 50.8 x 10.6 mm)  
Metal with Non-Conductive Base  
2.19 Oz (60g)  
Weight  
Reliability Specifications  
Parameter  
MTBF  
Absolute Maximum Ratings  
Parameter  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign 1,000  
Min.  
Typ.  
Typ.  
Max.  
Units  
kHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
Min.  
Max.  
20.0  
40.0  
80.0  
300  
Units  
VDC  
°C  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
Lead Temperature  
1.5 mm From Case For 10 Sec  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Capaci-  
Input  
Output  
Fuse Rating  
Model  
Number  
Efficiency  
(%, Typ)  
tive  
Load  
(µF Max)  
21,000  
Voltage (VDC)  
Current (mA)  
Slow-Blow  
(mA)  
Voltage Current  
Current  
(VDC) (mA, Max) (mA, Min)  
Nominal  
Range Full-Load No-Load  
C4001ERW  
C4002ERW  
C4003ERW  
C4004ERW  
C4011ERW  
C4012ERW  
C4013ERW  
C4014ERW  
C4021ERW  
C4022ERW  
C4023ERW  
C4024ERW  
12  
12  
12  
12  
24  
24  
24  
24  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
2,558  
3,876  
3,876  
3,831  
1,264  
1,873  
1,894  
1,873  
625  
20  
20  
20  
20  
15  
15  
15  
15  
10  
10  
10  
10  
3.3  
5.0  
12.0  
15.0  
3.3  
8,000  
8,000  
3,300  
2,666  
8,000  
8,000  
3,300  
2,666  
8,000  
8,000  
3,300  
2,666  
400.0  
400.0  
165.0  
133.0  
400.0  
400.0  
165.0  
133.0  
400.0  
400.0  
165.0  
133.0  
86  
86  
86  
87  
87  
89  
88  
88  
88  
90  
90  
90  
5,000  
5,000  
5,000  
5,000  
3,000  
3,000  
3,000  
3,000  
1,500  
1,500  
1,500  
1,500  
13,600  
2,360  
1,510  
21,000  
13,600  
2,360  
5.0  
12.0  
15.0  
3.3  
5.0  
12.0  
15.0  
1,510  
21,000  
13,600  
2,360  
926  
926  
926  
1,510  
Notes:  
A simple external circuit may be used to adjust the converter  
output. To adjust the output DOWN, connect a 5%, 3W resistor  
between the plus output pin and the Vout trim pin. To adjust the  
output UP, connect a 5%, 3W resistor between the minus output  
pin and the Vout trim pin. To calculate the correct resistor value  
(in k) use:  
External Trim  
0. When measuring output ripple,it is recommended that an external 0±.± µF ceramic capacitor  
be placed from the +Vout pin to the -Vout pin. For noise sensitive applications, the use of  
47 µF capacitors will reduce the output ripple.  
2. Transient recovery is measured to within a 0% error band for a load step change of 75% to  
0±±%.  
3. The Remote On/Off Control input (Pin 3) is referenced to -Vin (Pin 0). Connection to the  
pin should be made through a 0kresistor and diode (0N4048). If it is not used, the  
control pin should be left open.  
4. Operation at no-load will not damage these units. However, they may not meet all specifica-  
tions.  
5. The +sense and -sense connections will compensate for up to 5% of Vout. When not used,  
they should be connected directly to the appropriate output pin (+sense to +Vout and -sense  
to -Vout).  
(VOUT - 0.24) x (2.87)  
3.3 VOUT UP  
OtherVOUT UP  
RADJ  
RADJ  
=
=
- 0±  
- 0±  
V
ADJ - VOUT  
(VOUT - 2.5) x (2.87)  
VADJ - VOUT  
(VADJ - 0.24) (VOUT - 0.24) x 2.87  
3.3 VOUT Down RADJ  
OtherVOUT Down RADJ  
=
=
- 0±  
- 0±  
6. To improve performance and stability, a simple external LC filter can be added to the unit  
input.Typical component values would be 0.± µH/0±A & 0,±±± µF/25V for 02V input models;  
2.2 µH/0±A & 0,±±± µF/5±V for 24V input models; and 74.7 µH/5A & 0,±±± µF/0±±V for 48V  
input models.  
V
OUT - VADJ  
(VADJ - 2.5) (VOUT - 2.5) x 2.87  
V
OUT - VADJ  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the  
table above for the correct rating.  
For UP/Down trimming capability, connect a 0± kW potentiometer  
between the plus and minus outputs with the wiper arm con-  
nected to the Vout trim pin.  
Mechanical Dimensions  
Derating Curves  
Pin Connections  
Pin Single  
Pin Single  
1
2
4
5
+Vin  
-Vin  
ON/OFF  
-Sense  
6
7
8
9
+Sense  
+Vout  
-Vout  
Trim  
Mechanical Notes:  
All dimensions are typical  
in inches (mm)  
Tolerance x.xx = ±±.±0 (±±.25)  
MicroPower Direct  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

C4005-401

Strip Terminal Block, 16A, 1 Row(s), 1 Deck(s)
MOLEX

C4006

BROADBAND: RF & WIRELESS
PULSE

C4006

Strip Terminal Block, 16A, 1 Row(s), 1 Deck(s)
MOLEX

C4006-10A

Strip Terminal Block, 16A, 1 Row(s), 1 Deck(s)
MOLEX

C4006-401

Strip Terminal Block
MOLEX

C4006-L

Strip Terminal Block
MOLEX

C4006401

暂无描述
MOLEX

C4007-401

Strip Terminal Block
MOLEX

C4007401

STRIP TERMINAL BLOCK
MOLEX

C4008

Strip Terminal Block, 16A, 1 Row(s), 1 Deck(s)
MOLEX

C4008-10A

Strip Terminal Block
MOLEX

C4008-401

Strip Terminal Block
MOLEX