B2025RW [MPD]

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers; 紧凑的1 ×2英寸20W宽输入范围DC / DC体质VERT器
B2025RW
型号: B2025RW
厂家: MICROPOWER DIRECT, LLC    MICROPOWER DIRECT, LLC
描述:

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers
紧凑的1 ×2英寸20W宽输入范围DC / DC体质VERT器

文件: 总2页 (文件大小:254K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
B2000RWSeries  
Compact 1 x 2 Inch 20W  
Wide Input Range  
DC/DC Converters  
Electrical Specifications  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
Key Features:  
20W Output Power  
Conditions  
12 VDC Input  
Min.  
8.6  
Typ.  
8.8  
Max.  
9.0  
Units  
Input Start Voltage  
24 VDC Input 17.0  
48 VDC Input 34.0  
(Pi) Filter (Complies with EN55022 Class “A”)  
17.5  
35.0  
18.0  
36.0  
VDC  
2:1 Input Voltage Range  
1,500 VDC Isolation  
Compact 1 x 2 Inch Case  
Single & Dual Outputs  
Optional Remote ON/OFF  
Input Filter  
Reverse Polarity Input Current  
Short Circuit Input Power  
Output  
2.0  
3,500  
A
mW  
Parameter  
Conditions  
Min.  
Typ.  
0.5  
0.5  
0.1  
0.1  
55  
Max.  
1.0  
2.0  
0.3  
0.5  
80  
100  
10  
160  
300  
4.0  
Units  
%
%
%
%
mV P - P  
mV P - P  
mV rms  
%
µSec  
%
Industry Standard Pin-Out  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Dual Output , Balanced Loads  
Vin = Min to Max  
Load Regulation  
Iout = 10% to 100%  
Ripple & Noise (20 MHz) (Note 1)  
Ripple & Noise (20 MHz)  
Ripple & Noise (20 MHz)  
Output Power Protection  
Transient Recovery Time (Note 2)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
Over Line, Load & Temp.  
25% Load Step Change  
110  
150  
2.0  
0.01  
0.02  
%/°C  
Continuous (Autorecovery)  
Parameter  
Isolation Voltage  
Conditions  
Min.  
Typ.  
Max.  
Units  
VDC  
VDC  
M⍀  
pF  
kHz  
60 Seconds 1,500  
Isolation Test Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Remote On/Off (Note 3)  
Parameter  
Flash Tested For 1 Sec 1,650  
500 VDC 1,000  
100 kHz, 1V  
1,200 1,500  
330  
290  
360  
Conditions  
Min.  
2.5  
Typ.  
Max.  
100.0  
1.0  
Units  
VDC  
VDC  
mA  
Supply On  
Supply Off  
0.0  
Standby Input Current  
Control Common  
Environmental  
Parameter  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
2
5
Referenced to Negative Input (pin 2)  
Conditions  
Min.  
-40  
Typ.  
+25  
Max.  
+50  
+105  
+125  
Units  
°C  
°C  
Ambient  
Case  
-50  
°C  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
RFI  
Six-Side Shielded Metal Case  
EN55022 Class “A”  
Conducted EMI  
MicroPower Direct  
292 Page Street  
Suite D  
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
Reliability Specifications  
Parameter  
MTBF  
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)  
Metal with Non-Conductive Base  
1.06 Oz (30g)  
Conditions  
Min.  
800  
Typ.  
Typ.  
Max.  
Units  
kHours  
T: (781) 344-8226  
F: (781) 344-8481  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
MIL HDBK 217F, 25°C, Gnd Benign  
Absolute Maximum Ratings  
Parameter  
Conditions  
Min.  
Max.  
25.0  
50.0  
100.0  
260.0  
4,500  
Units  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
VDC  
Lead Temperature  
Internal Power Dissipation  
1.5 mm From Case For 10 Sec  
All Models  
°C  
mW  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
www.micropowerdirect.com  
Model Selection Guide  
www.micropowerdirect.com  
Over  
Input  
Reflected  
Ripple  
Current  
(mA, Typ)  
Output  
Capacitive Fuse Rating  
Model  
Number  
Voltage Efficiency  
Protection (%, Typ)  
(VDC)  
Voltage (VDC)  
Current (mA)  
Load  
Slow-Blow  
(mA)  
Voltage Current  
Current  
(µF Max)  
(VDC) (mA, Max) (mA, Min)  
Nominal Range Full-Load No-Load  
B2001RW  
B2002RW  
B2003RW  
B2004RW  
B2005RW  
B2006RW  
B2011RW  
B2012RW  
B2013RW  
B2014RW  
B2015RW  
B2016RW  
B2021RW  
B2022RW  
B2023RW  
B2024RW  
B2025RW  
B2026RW  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
1,358  
1,984  
1,898  
1,903  
1,898  
1,903  
671  
980  
938  
941  
938  
941  
335  
490  
469  
471  
469  
471  
30  
30  
30  
30  
30  
30  
17  
17  
17  
17  
17  
17  
10  
10  
10  
10  
10  
10  
50  
50  
50  
50  
50  
50  
30  
30  
30  
30  
30  
30  
20  
20  
20  
20  
20  
20  
3.3  
5.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
240.0  
240.0  
100.0  
80.0  
50.0  
40.0  
3.9  
6.8  
81  
84  
88  
88  
88  
88  
82  
85  
89  
89  
89  
89  
82  
85  
89  
89  
89  
89  
470  
470  
470  
470  
220  
220  
470  
470  
470  
470  
220  
220  
470  
470  
470  
470  
220  
220  
4,000  
4,000  
4,000  
4,000  
4,000  
4,000  
2,000  
2,000  
2,000  
2,000  
2,000  
2,000  
1,000  
1,000  
1,000  
1,000  
1,000  
1,000  
12.0  
15.0  
12.0  
15.0  
3.3  
15.0  
18.0  
15.0  
18.0  
3.9  
670.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
5.0  
6.8  
12.0  
15.0  
12.0  
15.0  
3.3  
15.0  
18.0  
15.0  
18.0  
3.9  
670.0  
4,000.0  
4,000.0  
1,670.0  
1,340.0  
835.0  
5.0  
6.8  
12.0  
15.0  
12.0  
15.0  
15.0  
18.0  
15.0  
18.0  
670.0  
Derating Curve  
For heatsink option, add suffix “H” to model number (i.e. B2003RW-H)  
For Remote Control option, add suffix “R” to model number (i.e. B2003RW-R)  
Notes:  
1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from  
the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units.  
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.  
3. The maximum control current at the on/off pin (pin 6) during a logic high is 5 µA.The maximum control current  
to the on/off pin at logic low is -100 µA. If the on/off pin is left open, the unit operates. If it is grounded, the  
unit will shut off.  
4. Operation at no-load will not damage these units. However, they may not meet all specifications.  
5. Dual output units may be connected to provide a 24VDC or 30VDC output.To do this, connect the load across  
the positive (+Vout) and negative (-Vout) outputs and float the output common.  
6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive  
impedance may affect the stability of the converter. In applications where the converter output loading is high  
and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure  
start-up.  
In this case, it is recommended that a low ESR (ESR <1.0at 100 kHz) capacitor be mounted close to the  
converter. For 12V input units, a 22.0 µF is recommended; for 24V & 48V units a 6.8 µF.  
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for  
the correct rating.  
Heatsink Dimensions (Optional)  
Mechanical Dimensions  
Pin Connections  
Pin Single  
Dual  
+Vin  
-Vin  
1
2
3
4
5
6
+Vin  
-Vin  
+Vout  
No Pin Comm.  
-Vout -Vout  
ON/OFF ON/OFF  
+Vout  
Heatsink Notes:  
Use of the heatsink will extend the units operating temperature  
range by approximately 10°C.  
The heatsink is black anodized aluminum.  
Mechanical Notes:  
MicroPower Direct  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
We Power Your Success - For Less!  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

B2025RW-F

Analog Circuit
MPD

B2025RW-R

Analog Circuit
MPD

B2026

BROADBAND ACCESS: xDSL, HPN, CMCs
PULSE

B2026-1M

Dual-Channel Power Distribution Switch
ETC

B2026-1P

Dual-Channel Power Distribution Switch
ETC

B2026-2M

Dual-Channel Power Distribution Switch
ETC

B2026-2P

Dual-Channel Power Distribution Switch
ETC

B2026RW

Compact 1 x 2 Inch 20W Wide Input Range DC/DC Con vert ers
MPD

B2026RW-F

Analog Circuit
MPD

B2026RW-R

Analog Circuit
MPD

B2028

Peripheral IC
ETC

B203

FIXED INPUT ISOLATED & UNREGULATED 1W OUTPUT 6000VDC ISOLATION SINGLE OUTPUT DIP PACKAGE
INTRONICS