B1000ERWSeries  
Low Cost 1 x 2 Inch 10W  
Wide Input Range  
A
DC/DC Converters  
Budget  
Saver!!  
Electrical Specifications  
Key Features:  
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.  
Input  
Parameter  
10W Output Power  
2:1 Input Voltage Range  
1,500 VDC Isolation  
Efficiency to 86%  
Conditions  
12 VDC Input  
Min.  
9.0  
Typ.  
12.0  
24.0  
48.0  
Max.  
18.0  
36.0  
72.0  
Units  
Input Voltage Range  
24 VDC Input 18.0  
48 VDC Input 36.0  
π (Pi) Filter  
VDC  
Input Filter  
Short Circuit Input Power  
Output  
Parameter  
Output Voltage Accuracy  
Output Voltage Balance  
Line Regulation  
Compact 1 x 2 Inch Case  
Single & Dual Outputs  
Industry Standard Pin-Out  
Lowest Cost!!  
1,500  
mW  
Conditions  
Min.  
Typ.  
Max.  
3.0  
5.0  
0.2  
0.5  
5.0  
50  
Units  
%
Dual Output , Balanced Loads  
Vin = Min to Max  
%
%
%
%
0.1  
0.2  
3.0  
30  
Positive Load Regulation  
Negative Load Regulation  
Ripple  
Iout = 25% to 100%  
Iout = 25% to 100%  
Bandwidth = 20 Hz to 300 kHz  
Bandwidth = DC to 20 MHz  
mV P - P  
mV P - P  
%
µSec  
%
Noise  
100  
Output Power Protection  
Transient Recovery Time (Note 1)  
Transient Response Deviation  
Temperature Coefficient  
Output Short Circuit  
General  
110  
RoHS Compliant  
200  
2.0  
0.01  
25% Load Step Change  
0.02  
%/°C  
Continuous  
Parameter  
Conditions  
Conditions  
Min.  
60 Seconds 1,500  
500 VDC 1,000  
100 kHz, 1V  
Typ.  
Max.  
Units  
VDC  
MΩ  
pF  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Environmental  
Parameter  
Operating Temperature Range  
Operating Temperature Range  
Storage Temperature Range  
Cooling  
130  
300  
kHz  
Min.  
Typ.  
+25  
+25  
Max.  
+71  
+90  
Units  
°C  
°C  
Ambient  
Case  
-40  
-40  
-40  
+125  
°C  
MicroPower Direct  
292 Page Street  
Suite D  
Free Air Convection  
RH, Non-condensing  
Humidity  
95  
%
Stoughton, MA 02072  
USA  
Physical  
Case Size  
Case Material  
Weight  
2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm)  
Non-Conductive Black Plastic (UL94-V0)  
1.06 Oz (30g)  
T: (781) 344-8226  
F: (781) 344-8481  
Reliability Specifications  
Parameter  
MTBF  
Absolute Maximum Ratings  
Parameter  
E: sales@micropowerdirect.com  
W: www.micropowerdirect.com  
Conditions  
MIL HDBK 217F, 25°C, Gnd Benign  
Min.  
1.0  
Typ.  
Typ.  
Max.  
Units  
MHours  
Conditions  
Min.  
Max.  
25.0  
45.0  
100.0  
300  
5,000  
Units  
12 VDC Input -0.7  
24 VDC Input -0.7  
48 VDC Input -0.7  
Input Voltage Surge (1 Sec)  
VDC  
Lead Temperature  
Internal Power Dissipation  
1.5 mm From Case for 10 Sec  
All Models  
°C  
mW  
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.  
Model Selection Guide  
Input  
Output  
Current  
(mA, Max) (mA, Min)  
Fuse Rating  
Slow-Blow  
(mA)  
Model  
Number  
Efficiency  
(%, Typ)  
Voltage (VDC)  
Current (mA)  
Voltage  
(VDC)  
Current  
Nominal  
Range  
Full-Load No-Load  
B1001ERW  
B1002ERW  
B1003ERW  
B1004ERW  
B1005ERW  
B1006ERW  
B1011ERW  
B1012ERW  
B1013ERW  
B1014ERW  
B1015ERW  
B1016ERW  
B1021ERW  
B1022ERW  
B1023ERW  
B1024ERW  
B1025ERW  
B1026ERW  
12  
12  
12  
12  
12  
12  
24  
24  
24  
24  
24  
24  
48  
48  
48  
48  
48  
48  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
9.0 - 18.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
18.0 - 36.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
36.0 - 75.0  
1,111  
1,068  
1,041  
1,157  
1,082  
1,041  
555  
534  
520  
563  
508  
496  
257  
242  
242  
264  
245  
245  
25  
25  
25  
25  
25  
25  
8
8
8
8
8
8
5
5
5
5
5
5
5
12  
15  
5
12  
15  
5
12  
15  
5
12  
15  
5
2,000  
832  
660  
1,000  
416  
333  
2,000  
832  
660  
1,000  
416  
333  
2,000  
830  
670  
1,000  
416  
333  
200  
83  
66  
100  
41  
33  
200  
83  
66  
100  
41  
33  
200  
83  
66  
100  
41  
33  
75  
78  
80  
72  
77  
80  
75  
78  
80  
74  
82  
84  
81  
86  
86  
79  
85  
85  
3,000  
3,000  
3,000  
3,000  
3,000  
3,000  
1,500  
1,500  
1,500  
1,500  
1,500  
1,500  
750  
12  
15  
5
12  
15  
750  
750  
750  
750  
750  
Notes:  
Derating Curve  
1. Transient recovery is measured to within a 1% error band for a load  
step change of 75% to 100%.  
2. Output load regulation is specified for a load change of 25% to  
100%.  
3. When measuring output ripple, it is recommended that an external  
ceramic capacitor (approx approx 1 µF to 10 µF) be placed from the  
+Vout pin to the -Vout pin for single output units and from each output  
to common for dual output units.  
4. These units should not be operated with a load under 10% of full load.  
Operation at no-load may cause damage to the unit.  
5. These converters are specified for operation without external com-  
ponents. However, in some applications the addition of input/ouput  
capacitors will enhance stability and reduce output ripple. Recom-  
mended capacitor values are:  
Input  
Capacitor  
Output  
Capacitor  
Vin  
12 VDC  
24 VDC  
48 VDC  
100 µF  
100 µF  
100 µF  
100 µF per 1A of Iout  
100 µF per 1A of Iout  
100 µF per 1A of Iout  
For applications requiring very low output noise levels, a simple LC  
filter should be effective.  
Mechanical Dimensions  
6. Dual output units may be connected to provide a 10V, 24V or 30 VDC  
output. To do this, connect the load across the positive (+Vout) and  
negative (-Vout) outputs and float the output common.  
7. It is recommended that a fuse be used on the input of a power supply  
for protection. See the Model Selection table above for the correct  
rating.  
Capacitive  
Load  
Pin Connections  
Pin  
1
Single  
+Vin  
Dual  
+Vin  
Single Output  
(µF Max)  
2
3
4
5
-Vin  
-Vin  
400  
+Vout  
No Pin  
-Vout  
+Vout  
Common  
-Vout  
Dual Output  
(µF Max)  
200  
Mechanical Notes:  
All dimensions are typical in inches (mm)  
Tolerance x.xx = 0.01 ( 0.25)  
MicroPower Direct  
www.micropowerdirect.com  
292 Page Street Ste D Stoughton, MA 02072  
TEL: (781) 344-8226  
FAX: (781) 344-8481  
E-Mail: sales@micropowerdirect.com  

相关型号:

B1013RW

Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters
MPD

B1014-QT

37.0-40.0 GHz GaAs MMIC
MIMIX

B1014-QT_11

37.0-40.0 GHz GaAs MMIC
MIMIX

B10140AA1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AB1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AC1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AD1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AG1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AS1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B10140AT1

FEMALE HEADER PROFILE : 8.6mm STRAIGHT
DBLECTRO

B1014ERW

Low Cost 1 x 2 Inch 10W Wide Input Range DC/DC Converters
MPD

B1014RW

Compact 1 x 2 Inch 10W Wide Input Range DC/DC Converters
MPD