Very Low Cost, 20W
DIN Rail Mount
Single Output
AC/DC Power Supplies
Models available to
360W! Call today
for details
Key Features:
Electrical Specifications
• 20W Output Power
• DIN Rail Mountable
• Universal AC Input
• UL ꢀ08 Compliant
• EN609ꢀ0 Compliant
• ꢀ, 12, 24 & 48 VDC Outputs
• Cond./Rad. EMI Class B
• >170 kH MTBF
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
100
127
47
Typ.
Max.
240
370
63
Units
VAC
VDC
Hz
Universal
Input Voltage Range
Input Frequency
110 VAC
220 VAC
264 VAC
22
44
A
A
Inrush Current, Cold Start
• LOW COST!
Leakage Current
Output
1.8
mA
Parameter
Conditions
Min.
Typ.
0.ꢀ
1.0
1.0
10
Max.
Units
%
%
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
Vin = Min to Max
Iout = 20% to 100%
110 VAC, Full Load
220 VAC, Full Load
%
Hold Time
mSec
20
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Transient Recovery Time (Note 3)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
See Model Selection Guide
Power Limit 130
2
160
0.03
Max.
%
mS
%
ꢀ0% Load Change
ꢀ
0.02
%/ºC
Continuous With Autorecovery
General
Parameter
Conditions
Min.
Typ.
Units
Input - Output 3,000
Isolation Voltage
Input - FG (Frame Ground) 2,000
VAC
Output - FG (Frame Ground)
ꢀ00
100
Isolation Resistance (Note 4)
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
ꢀ00 VDC
Fixed
M⍀
kHz
66
Conditions
Min.
-20
-20
Typ.
+2ꢀ
Max.
+ꢀ0
+8ꢀ
Units
ºC
ºC
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Ambient
Free Air Convection
RH, Non-condensing
Humidity
9ꢀ
%
Physical
Case Size
Case Material
Connection
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
3.ꢀ4 x 2.ꢀ4 x 1.77 Inches (90.0 x 64.ꢀ x 44.0 mm)
Plastic
Screw Terminal
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
MTBF
MIL HDBK 217F, 2ꢀºC, Gnd Benign
170
kHours
Safety Standards
EMI Compliance
EMS Immunity Compliance
UL 19ꢀ0, EN 609ꢀ0, IEC 609ꢀ0
Compliance to ENꢀꢀ011, ENꢀꢀ022 (CISPR22) Class B
EN61000-4-2,3,4,ꢀ,6,8,11 Level 3
Model Selection Guide
Input
Output
Output
Ripple &
Noise
Rated
Model
Overvoltage
Protection
(VDC)
Fuse Rating
Slow-Blow
(A)
Efficiency
(%, Typ)
Power Voltage (VAC)
Number
Current (A)
Voltage Current (A) Current (A)
(W)
(VDC)
Max)
Range
(mV P-P)
Universal Range 115 VAC 230 VAC
AD1020-0ꢀF
AD1024-12F
AD1024-24F
AD1024-48F
20
24
24
24
100 - 240
100 - 240
100 - 240
100 - 240
1.0
1.0
1.0
1.0
0.ꢀ
0.ꢀ
0.ꢀ
0.ꢀ
ꢀ
12
24
48
4.0
2.0
1.0
0.ꢀ
0 ~ 4.0
0 ~ 2.0
0 ~ 1.0
0 ~ 0.ꢀ
ꢀ0
7.0
20.0
40.0
60.0
78
80
83
83
2.0
2.0
2.0
2.0
100
1ꢀ0
2ꢀ0
Notes:
Derating Curve
1. Load regulation is specified for a load change of 20% to
100%.
2. Ripple & noise is measured using equipment with 20 Mhz of
bandwidth with the unit under test operating at rated load
and a 110 VAC input. Connection to the unit is made with
a 0.1 µF / 630V metalized capacitor & a 47 µF electrolytic
capacitor connected in parallel.
3. Transient recovery is measured to within a 1% error band
for a load step change of 50% to 100%.
4. Isolation resistance is given for Input/Output and Input/FG.
For Output/FG., it is 50 M⍀
5. Overload protection is power limiting. The unit recovers
automatically when the fault is removed.
6. Over voltage protection is a shut down type.The unit recov-
ers automatically when the fault is removed.
7. To mount the unit to the DIN rail, tilt the unit rearwards from
the top, fitting the mount over the top of the rail. Press back
on the bottom front of the unit until it locks in place on the
rail.To remove the unit from the rail, pull the removal clip at
the bottom rear of the unit downward with a screw driver.
With the clip down, lift up on the unit from the bottom front
until it clears the rail.Before installation or removal all wiring
should be disconnected and the main power to the system
shut off.
8. When wiring the supply, all lines should be as thick and
short as possible. AWG 14 wire is recommended for the
AD1024F series.
9. The units should be mounted so they are vertically orien-
tated. Air flow (if it is provided) would optimally flow from
the bottom to the top of the unit.
Mechanical Dimensions
10. It is recommended that a fuse be used on the input of a
power supply for protection. For the AD1024F series,
a 250 VAC 2.0A is recommended.
Connections TB 1
Pin
Function
DC Output (+V)
DC Output (-V)
Frame Ground (FG)
AC/Neutral
1
2
3
4
ꢀ
AC/Live
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = 0.01 ( 0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
AD102448F 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
AD1024F | MPD | Very Low Cost, 20W DIN Rail Mount Single Output AC/DC Power Supplies | 获取价格 | |
AD1024F_14 | MPD | AD1024F Series | 获取价格 | |
AD10265 | ADI | Dual Channel, 12-Bit, 65 MSPS A/D Converter with Analog Input Signal Conditioning | 获取价格 | |
AD10265/PCB | ADI | Dual Channel, 12-Bit, 65 MSPS A/D Converter with Analog Input Signal Conditioning | 获取价格 | |
AD10265AZ | ADI | Dual Channel, 12-Bit, 65 MSPS A/D Converter with Analog Input Signal Conditioning | 获取价格 | |
AD10265PCB | ADI | High Speed ADC USB FIFO Evaluation Kit | 获取价格 | |
AD102E3 | MICROSEMI | Silicon Controlled Rectifier, 2.512A I(T)RMS, 200V V(DRM), 200V V(RRM), 1 Element, TO-39, TO-39, 3 PIN | 获取价格 | |
AD102JY | ADI | General Purpose Input Isolation Amplifier | 获取价格 | |
AD103 | MICROSEMI | SCRs 1.5 Amp, Planar | 获取价格 | |
AD103 | NJSEMI | Thyristor SCR 300V 15A 3-Pin TO-39 | 获取价格 |
AD102448F 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6