PT-508-SS-LC-48 [MOXA]
IEC 61850-3 8-port Layer 2 DIN-rail managed Ethernet switches;型号: | PT-508-SS-LC-48 |
厂家: | Moxa |
描述: | IEC 61850-3 8-port Layer 2 DIN-rail managed Ethernet switches |
文件: | 总5页 (文件大小:722K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PT-508 Series
IEC 61850-3 8-port Layer 2 DIN-rail managed Ethernet switches
Features and Benefits
• IEC 61850-3 and IEEE 1613 compliant
• Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), and
STP/RSTP/MSTP for network redundancy
• Easy network management by web browser, CLI, Telnet/serial console,
Windows utility, and ABC-01
• Isolated universal 24 VDC or 48 VDC redundant power inputs
• Wide 110/220 VDC/VAC power supply range
• Modbus TCP, LLDP, SNMP Inform, QoS, IGMP snooping, VLAN, IEEE
802.1X, HTTPS, SNMPv3, and SSH supported
• -40 to 85°C operating temperature range
Certifications
Introduction
The PowerTrans PT-508 Series is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613). The
PT-508’s optical fiber Fast Ethernet backbone, redundant ring, redundant power inputs (24 VDC or 48 VDC), and isolated power inputs (24 VDC, 48
VDC, or 110/220 VDC/VAC) increase the reliability of your communications and save on cabling/wiring costs. In addition, the DIN-rail and wall-
mounting design of the PT-508 switches simplify network planning, and allows greater flexibility by letting you install up to 8 Fast Ethernet ports for
power distribution applications.
Additional Features and Benefits
• Command line interface (CLI) for quickly configuring major
managed functions
• VLAN Unaware: Supports priority-tagged frames to be received by
specific IEDs
• EtherNet/IP and Modbus TCP industrial Ethernet protocols
supported
• IEEE 802.3ad, LACP for optimum bandwidth utilization
• Bandwidth management to prevent unpredictable network status
• Multi-port mirroring for online debugging
• Automatic warning by exception through email and relay output
• RMON for proactive and efficient network monitoring
• Automatic recovery of connected device’s IP addresses
• Configurable by web browser, Telnet/Serial console, CLI, Windows • Line-swap fast recovery
utility, and ABC-01 automatic backup configurator
• DHCP Option 82 for IP address assignment with different policies
• IGMP snooping and GMRP for filtering multicast traffic from
industrial Ethernet protocols
Cybersecurity Features
• User passwords with multiple levels of security protect against
unauthorized configuration
• 802.1Q VLAN allows you to logically partition traffic transmitted
between selected switch ports
• SSH/HTTPS is used to encrypt passwords and data
• Lock switch ports with 802.1X port-based network access control
so that only authorized clients can access the port
• Secure switch ports so that only specific devices and/or MAC
addresses can access the ports
• Disable one or more ports to block network traffic
• RADIUS/TACACS+ allows you to manage passwords from a central • SNMPv3 provides encrypted authentication and access security
location
Specifications
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
100BaseFX Ports (multi-mode SC connector)
100BaseFX Ports (multi-mode ST connector)
6
PT-508-MM-SC Series: 2
PT-508-MM-ST Series: 2
1
www.moxa.com
100BaseFX Ports (single-mode SC connector)
100BaseFX Ports (multi-mode LC connector)
100BaseFX Ports (single-mode LC connector)
Optical Fiber
PT-508-SS-SC Series: 2
PT-508-MM-LC Series: 2
PT-508-SS-LC Series: 2
100BaseFX
Multi-Mode
50/125 µm
Single-Mode
G.652
Fiber Cable Type
OM1
4 km
800 MHz x km
5 km
Typical Distance
Typical (nm)
40 km
1310
1300
Waveleng-
th
TX Range (nm)
RX Range (nm)
1260 to 1360
1280 to 1340
1100 to 1600
0 to -5
1100 to 1600
-10 to -20
-3 to -32
12
TX Range (dBm)
RX Range (dBm)
Link Budget (dB)
Dispersion Penalty (dB)
-3 to -34
29
Optical
Power
3
1
Note: When connecting a single-mode fiber transceiver, we recommend using an
attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link
budget (dB) > dispersion penalty (dB) + total link loss (dB).
Standards
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
Ethernet Software Features
Filter
802.1Q, GMRP, GVRP, IGMP v1/v2c, Port-based VLAN, VLAN unaware
EtherNet/IP, Modbus TCP
Industrial Protocols
Management
Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow
control, HTTP, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform,
SNMPv1/v2c/v3, Syslog, Telnet, TFTP
MIB
Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB
Groups 1, 2, 3, 9, RSTP MIB
Redundancy Protocols
Security
Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2
HTTPS/SSL, TACACS+, Port Lock, RADIUS, Rate Limit, SSH
NTP Server/Client, SNTP, 100BaseFX Single-Mode
Time Management
Switch Properties
IGMP Groups
256
8 K
MAC Table Size
2
www.moxa.com
Max. No. of VLANs
Packet Buffer Size
VLAN ID Range
64
1 Mbits
VID 1 to 4094
4
Priority Queues
Serial Interface
Console Port
RS-232 (RJ45)
Input/Output Interface
Alarm Contact Channels
Resistive load: 1 A @ 24 VDC
Power Parameters
Connection
1 removable 5-contact terminal block(s)
Input Voltage
PT-508-24/48 Series: Redundant power inputs
PT-508-24 Series: 24 VDC (18 to 36 VDC)
PT-508-48 Series: 48 VDC (36 to 72 VDC)
PT-508–HV Series: 110/220 VAC/VDC (88 to 300 VAC, 85 to 264 VDC)
Overload Current Protection
Reverse Polarity Protection
Input Current
Supported
Supported
PT-508-24 Series: 0.27 A @ 24 VDC
PT-508-48 Series: 0.12 A @ 48 VDC
PT-508-HV Series: 0.18/0.11 A @ 110/220 VAC, 0.084/0.043 A @ 110/220 VDC
Physical Characteristics
Housing
Aluminum
IP Rating
IP40
Dimensions (without ears)
Weight
60 x 160 x 110 mm (2.36 x 6.30 x 4.33 in)
995 g (2.21 lb)
Installation
DIN-rail mounting, DIN-rail mounting (with optional kit)
Environmental Limits
Operating Temperature
-40 to 85°C (-40 to 185°F)
Note: Cold start requires minimum of 100 VAC @ -40°C
Storage Temperature (package included)
Ambient Relative Humidity
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
Standards and Certifications
EMI
EN 55032 Class A, CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Power Substation
Safety
IEC 61850-3, IEEE 1613
UL 508
3
www.moxa.com
MTBF
Time
394,238 hrs
Standards
Telcordia SR332
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty
Package Contents
Device
1 x PT-508 Series switch
Cable
1 x DB9 female to RJ45 10-pin
1 x grounding cable
Installation Kit
1 x DIN-rail kit
2 x cap, plastic, for SC fiber port (PT-508-SC Series)
2 x cap, plastic, for ST fiber port (PT-508-ST Series)
2 x cap, plastic, for LC fiber port (PT-508-LC Series)
11 x cap, plastic, for RJ45 port
Documentation
1 x document and software CD
1 x quick installation guide
1 x warranty card
1 x product certificates of quality inspection, Simplified Chinese
1 x product notice, Simplified Chinese
Dimensions
Ordering Information
100BaseFX
Single-Mode
Ports with SC
Connector
100BaseFX
Multi-Mode
Ports with SC
Connector
100BaseFX
Multi-Mode
Ports with ST
Connector
100BaseFX
Single-Mode
Ports with LC
Connector
100BaseFX
Multi-Mode
Ports with LC
Connector
10/
Model Name
Operating
Temp.
Input Voltage
100BaseT(X)
PT-508-SS-SC-24
PT-508-SS-SC-48
6
6
2
2
–
–
–
–
–
–
–
–
-45 to 85°C
-45 to 85°C
24 VDC
48 VDC
110/220 VDC/
VAC
PT-508-MM-ST-HV
6
–
–
2
–
–
-45 to 85°C
4
www.moxa.com
100BaseFX
Single-Mode
Ports with SC
Connector
100BaseFX
Multi-Mode
Ports with SC
Connector
100BaseFX
Multi-Mode
Ports with ST
Connector
100BaseFX
Single-Mode
Ports with LC
Connector
100BaseFX
Multi-Mode
Ports with LC
Connector
10/
100BaseT(X)
Operating
Temp.
Model Name
Input Voltage
24 VDC
PT-508-MM-SC-24
PT-508-SS-SC-HV
6
6
–
2
–
–
–
–
–
–
–
-45 to 85°C
-45 to 85°C
110/220 VDC/
VAC
2
PT-508-MM-SC-48
PT-508-MM-ST-24
PT-508-MM-ST-48
6
6
6
–
–
–
2
–
–
–
2
2
–
–
–
–
–
–
-45 to 85°C
-45 to 85°C
-45 to 85°C
48 VDC
24 VDC
48 VDC
PT-508-MM-SC-
HV
110/220 VDC/
VAC
6
–
2
–
–
–
-45 to 85°C
PT-508-SS-LC-24
PT-508-SS-LC-48
PT-508-MM-LC-24
PT-508-MM-LC-48
6
6
6
6
–
–
–
–
–
–
–
–
–
–
–
–
2
2
–
–
–
–
2
2
-45 to 85°C
-45 to 85°C
-45 to 85°C
-45 to 85°C
24 VDC
48 VDC
24 VDC
48 VDC
110/220 VDC/
VAC
PT-508-MM-LC-HV
PT-508-SS-LC-HV
6
6
–
–
–
–
–
–
–
2
–
-45 to 85°C
-45 to 85°C
110/220 VDC/
VAC
2
Accessories (sold separately)
Software
MXview-50
Industrial network management software with a license for 50 nodes (by IP address)
Industrial network management software with a license for 100 nodes (by IP address)
Industrial network management software with a license for 250 nodes (by IP address)
Industrial network management software with a license for 500 nodes (by IP address)
Industrial network management software with a license for 1000 nodes (by IP address)
Industrial network management software with a license for 2000 nodes (by IP address)
MXview-100
MXview-250
MXview-500
MXview-1000
MXview-2000
MXview Upgrade-50
License expansion of MXview industrial network management software by 50 nodes (by IP address)
Storage Kits
ABC-01
Configuration backup and restoration tool for managed Ethernet switches and AWK Series wireless
APs/bridges/clients, 0 to 60°C operating temperature
© Moxa Inc. All rights reserved. Updated Jul 02, 2019.
This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of
Moxa Inc. Product specifications subject to change without notice. Visit our website for the most up-to-date product information.
5
www.moxa.com
相关型号:
©2020 ICPDF网 联系我们和版权申明