LS05-15B15SS [MORNSUN]
AC/DC converter;型号: | LS05-15B15SS |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | AC/DC converter |
文件: | 总5页 (文件大小:284K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC/DC Converter
LS05-15BXXSS Series
5W, AC/DC converter
FEATURES
z Wide input voltage range: 85~264VAC/100~400VDC
z Over current protection and short circuit protection
z High efficiency, high safety isolation 3000VAC
z Urtal-slim SIP package
z Industrial grade
z Meet IEC60950, UL60950 and EN60950 standards
z UL60950, EN60950 approval
z 3 years of quality assurance
RoHS
LS05-15BXXSS series is a high efficiency green power modules provided by Mornsun. The features of this series are: Accept either AC or DC
input, wide input voltage, high efficiency, low loss, safety isolation etc. All models are particularly suitable for the applications such as
industrial, electric power, instrumentation, smart home which do not have high requirement on EMC.EMC application circuit must be added
if the products need to be applied to EMC harsh environment .
Selection Guide
Nominal Output Voltage
and Current(Vo/Io)
Efficiency
(230VAC,%/Typ.)
Max. Capacitive Load
(uF)
Certification
Model
Output Power
3.3W
LS05-15B03SS
LS05-15B05SS
LS05-15B09SS
LS05-15B12SS
LS05-15B15SS
LS05-15B24SS
67
74
75
76
77
79
3.3V/1A
5V/1A
2200
1500
680
9V/0.56A
12V/0.42A
15V/0.34A
24V/0.21A
UL/CE
470
5W
330
100
Input Specifications
Item
Operating Conditions
Min.
100
85
100
47
--
Typ.
--
Max.
240
264
400
63
Unit
Conventional
AC input
VAC
Input Voltage Range
--
--
VDC
Hz
DC input
--
Input frequency
Input current
115VAC
--
0.2
0.1
--
230VAC
--
--
A
115VAC
--
5
Inrush current
230VAC
--
10
--
--
leakage Current
CY0 is 1nF/400VAC
--
0.25
mA
Output Specifications
Item
Operating Conditions
LS05-15B03SS
Min.
--
Typ.
±2
Max.
±3
Unit
%
Output Voltage Accuracy
LS05-15B05/09/12/15/24SS
Full load
--
±1
±2
--
±0.1
±1
±0.5
±1.5
150
--
Line Regulation
--
Load Regulation
10%-100% load
--
50
mV
%/°C
W
Output Ripple & Noise*
Temperature Drift Coefficient
Stand-by Power Consumption
Short Circuit Protection
Over-current Protection
Over-voltage Protection
Min. Load
20MHz bandwidth (peak-peak value)
--
±0.02
--
--
0.5
Continuous, self-recovery
≥110%Io self-recovery
Zener clamp diode
0
--
--
%
2014.04.14-A/0
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS05-15BXXSS Series
--
--
20
80
--
--
115VAC input
230VAC input
ms
Hold-up Time
Note: *Ripple and Noise measuring refer to “ripple and noise measure figure”, please see AC-DC Converter Application Notes for specific operation methods.
General Specifications
Item
Operating Conditions
Min.
3000
-25
-40
--
Typ.
--
Max.
--
Unit
VAC
Isolation Voltage
Input-output
Test time: 1min(leakage current setting value:5 mA)
--
+85
+105
85
Operating Temperature
Storage Temperature
Storage Humidity
°C
--
--
%RH
Wave-soldering
Manual-welding
260±5℃; time:5~10s
360±10℃; time:3~5s
Welding Temperature
Switching Frequency
Power Derating
--
100
--
--
--
--
kHz
-25℃~0℃
0.8
%/
°C
+55℃~+85℃
1.33
--
IEC60950/EN60950/UL60950
EN60950/UL60950
CLASS II
Safety Standard
Safety-regulated Certification
Safety Class
Hot Plug
Unavailable
MIL-HDBK-217F@25°C > 300,000 h
MTBF
Physical Specifications
Package Dimensions
Weight
42.00*13.65*20.00mm
7 g(Typ.)
Cooling method
Free air convection
EMC Specifications
CISPR22/EN55022, CLASS A (See Fig. 1 for recommended circuit)
CISPR22/EN55022, CLASS B (See Fig. 2 for recommended circuit)
CISPR22/EN55022, CLASS B (See Fig. 1or Fig. 2 for recommended circuit)
Conducted Disturbance
EMI
Radiated Emission
IEC/EN61000-4-2
IEC/EN61000-4-3
IEC/EN61000-4-4
contact ±4KV
Perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria A
Electrostatic Discharge
Radiation Immunity
10V/m
±2KV (See Fig. 1 for recommended circuit)
EFT
IEC/EN61000-4-4
IEC/EN61000-4-5
IEC/EN61000-4-6
±4KV (See Fig. 2 for recommended circuit)
EMS
Surge Immunity
±1KV/2KV (See Fig. 1or Fig. 2 for recommended circuit)
3 Vr.m.s(See Fig. 2 for recommended circuit)
Conducted Disturbance
Immunity for Power
IEC/EN61000-4-8
10A/m
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-11
0%-70%
perf. Criteria B
Product Characteristic Curve
Temperature Derating Graph
Input Voltage Derating Graph
100
100
80
80
Ambient temperature:25
℃
60
40
60
Input voltage:110~240VAC
40
-25
0
55
85
85
110
240
264 VAC
Ambient Temperature(
℃
)
Input Voltage
( )
V
Note: Input voltage should be derated based on temperature derating
when it is 85~110VAC /240~264VAC.
Note: When input DC, VDC=1.414VAC-20.
2014.04.14-A/0
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS05-15BXXSS Series
LS05-15B12SS AC Input
Efficiency Vs Output Load
LS05-15BXXSS AC Input
Efficiency Vs Input Voltage(Full Load)
90
85
80
75
70
65
60
55
50
90
85
80
75
70
65
60
LS05-15B24SS
efficiency
85VAC
LS05-15B12SS
efficiency
230VAC
240VAC
LS05-15B05SS
efficiency
10
20
30
40
50
60
70
80
90 100
85
110
120
220
230
240
264
Output Power Percentage(%)
Input Voltage(VAC)
LS05-15B12SS DC Input
Efficiency Vs Output Load
LS05-15BXXSS DC Input
Efficiency Vs Input Voltage(Full Load)
90
85
80
75
70
65
60
90
88
86
84
82
80
78
76
74
72
70
LS05-15B24SS
efficiency
300VDC Input
efficiency
200VDC Input
efficiency
LS05-15B12SS
efficiency
400VDC Input
efficiency
LS05-15B05SS
efficiency
100
150
200
250
300
350
400
10
20
30
40
50
60
70
80
90 100
Input Voltage(VDC)
Output Power Percentage(%)
Design Reference
1. Typical application circuit
NTC
FUSE
R1
+Vo
14
C2 TVS C3 RL
+
AC(L)
AC(N)
3
5
C1
+
MOV
AC/DC
CX1
7
1
12
-Vo
CY0
Fig. 1: Typical application circuit
C1
(Required)
C2
(Required)
FUSE
(Required)
R1
NTC
MOV
Model
C3
CX1
CY0
TVS
LS05-15B03SS
LS05-15B05SS
LS05-15B09SS
LS05-15B12SS
LS05-15B15SS
LS05-15B24SS
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ30A
220μF/35V
150μF/35V
100nF/
50V
0.1μF/
275VAC
1nF/400
VAC
12Ω/2W
10μF/400V
13D-5
14D561K
1A/250V
Note:
1. C1: When AC input, C1 is used as filter capacitor, the value of C1 is recommended to be 10μF /400V.
When DC input, C1 is used as EMC filter capacitor, the value of C1 is recommended to be 10μF/400V(when the input voltage is above 370VDC, the
recommended value of C1 is 10μF/450V).
2. Output filtering capacitor C2 is electrolytic capacitor, C2 is recommended to apply electrolytic capacitor with high frequency and low resistance. For
capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitance withstand voltage derating should be 80% or above. C3 is
ceramic capacitor, which is used to filter high-frequency noise.
2014.04.14-A/0
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS05-15BXXSS Series
2. EMC solution-recommended circuit
NTC
FUSE
TVS
C3 RL
AC(L)
AC(L)
14
LDM
+Vo
CY1
CY2
LCM
C2
MOV2
CX
+
C1
+
AC/DC
5
7
-Vo
12
AC(N)
AC(N)
CY0
Fig 2: EMC application circuit with higher requirements
Fig 3: Recommended EMC circuit-PCB layout
Suggestions for safety regulation and wiring width: wire width ≥3mm, distance between wires ≥6mm, and distance between wire and
ground ≥6mm
Components
MOV2
CY1, CY2
CX
Recommend Parameter
S14K320
1nF/400VAC
0.1μF/275VAC
3.5mH
LCM
LDM
330μH
NTC
13D-5
FUSE
1A/250V, slow fusing, required
3. For more information please find application notes on www.mornsun-power.com
2014.04.14-A/0
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LS05-15BXXSS Series
Dimensions and Recommended Layout
Note:
1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58230001;
2. Module required dispensing fixed after assembled;
3. This part is open frame, at least 6.4mm safety distance between the the primary and secondary external components of the module is
needed to meet the safety requirement;
4. All specifications were measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified;
5. All index testing methods in this datasheet are based on our Company’s corporate standards;
6. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products
will exceed the above-mentioned requirements, and please directly contact our technician for specific information;
7. We can provide product customization service;
8. Specifications of this product are subject to changes without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2014.04.14-A/0
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
©2020 ICPDF网 联系我们和版权申明