LS01-15B12S [MORNSUN]

LS01 Series ----- are high efficiency green power modules with miniature packaging provided by Mornsun.; LS01系列-----高效率绿色电源模块金升阳所提供的微型封装。
LS01-15B12S
型号: LS01-15B12S
厂家: MORNSUN SCIENCE& TECHNOLOGY LTD.    MORNSUN SCIENCE& TECHNOLOGY LTD.
描述:

LS01 Series ----- are high efficiency green power modules with miniature packaging provided by Mornsun.
LS01系列-----高效率绿色电源模块金升阳所提供的微型封装。

电源电路
文件: 总4页 (文件大小:412K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LS01 Series  
1W, HIGH VOLTAGE DC-DC(AC-DC) CONVERTER  
LS01 Series ----- are high efficiency green power modules with miniature  
packaging provided by Mornsun. The features of this series are: wide input  
voltage, DC and AC all in one, high efficiency, high reliability, low loss, safety  
isolation etc, meet UL60950/EN60950 standards. All models are particularly  
suitable for the applications demanding on the volume, need to meet UL/CE  
standard, less demanding on EMC like industrial, electric power,  
instrumentation, smart home. For harsh EMC environment, this series of  
products must use the refered application circuit.  
RoHS  
FEATURES  
PART NUMBER SYSTEM  
LS01-15B15S  
1. Wide input voltage:100 ~ 400VDC(85 ~ 264VAC)  
2. Over current protection and short circuit protection  
3. High efficiency, high density  
4. Low loss, green power  
5. Industrial level  
6. Ultra-Miniature package  
Special Mark  
Output Voltage  
Output Style  
put Voltage  
In  
Voltage  
Isolation  
Output Power  
Package Style  
Product Series  
7. Meet UL/CE standard  
SELECTION GUIDE  
Package  
(Typ.)  
Efficiency (%)  
Output (Vo/Io)  
Ripple and Noise  
Model  
Power  
1W  
(Typ.)  
66  
LS01-15B05S  
LS01-15B09S  
LS01-15B12S  
LS01-15B15S  
LS01-15B24S  
5V/200mA  
9V/111mA  
100mV(Typ.)  
150mV(Max.)  
120mV(Max.)  
120mV(Max.)  
120mV(Max.)  
150mV(Max.)  
67  
80mV(Typ.)  
80mV(Typ.)  
80mV(Typ.)  
100mV(Typ.)  
34.0*26.0*10.5mm  
70  
12V/83.3mA  
15V/66.6mA  
24V/41.6mA  
69  
68  
INPUT SPECIFICATIONS  
Input voltage range  
100~400VDC(85~264VAC)  
120mA (Max.)  
20A  
Input current  
Inrush current  
External input fuse (recommended)  
1A/250V  
slow blow  
OUTPUT SPECIFICATIONS  
-25~+55℃  
-40~+85℃  
±5%  
LS01-15B05S  
±10%  
LS01-15B09S  
LS01-15B12S  
LS01-15B15S  
LS01-15B24S  
Voltage set accuracy  
-25~+55℃  
-40~+85℃  
±3%  
±5%  
Input variation  
±1.5% (Typ.)  
±2.5% (Typ.)  
100mV(Typ.)  
80mV(Typ.)  
80mV(Typ.)  
80mV(Typ.)  
100mV(Typ.)  
Load variation (5%~100%)  
5 VDC output  
9 VDC output  
12VDC output  
15VDC output  
24VDC output  
150mV(Max.)  
120mV(Max.)  
120mV(Max.)  
120mV(Max.)  
150mV(Max.)  
Ripple & noise(p-p)  
(20MHz Bandwidth)  
Note :Low frequency ripple is  
normal.  
Short circuit protection  
Continuous, automatic resume  
No  
Over temperature protection  
The copyright and authority for the interpretation of the products are reserved by MORNSUN  
Specifications subject to change without notice.  
LS01 series A/0-2012 Page 1 of 4  
COMMON SPECIFICATIONS  
Operating  
-40+85℃  
1.33%/ ℃  
(5585)  
Power  
derating  
Temperature ranges  
2%/ ℃  
(-40-20)  
-40+105℃  
Storage  
The Max. Case Temperature +90(Max.)  
Humidity  
85% (Max.)  
0.1%/℃  
Temperature coefficient  
Switching frequency  
I/O-isolation voltage  
Variational Frequency 50KHz (Max.)  
Input and Output  
CE  
3000VAC/1Min  
CISPR22/EN55022 CLASS AExternal Circuit Refer to Figure 1)  
CISPR22/EN55022 CLASS BExternal Circuit Refer to Figure 3)  
CISPR22/EN55022 CLASS AExternal Circuit Refer to Figure 1)  
EMI  
RE  
CISPR22/EN55022 CLASS BExternal Circuit Refer to Figure 3)  
IEC/EN61000-4-2 Contact ±4KV perf. Criteria B  
ESD  
RS  
IEC/EN61000-4-3 10V/m  
IEC/EN61000-4-4 ±2KV  
IEC/EN61000-4-4 ±4KV  
IEC/EN61000-4-5 ±2KV/±4KV  
IEC/EN61000-4-6 3 Vr.m.s  
IEC/EN61000-4-8 10A/m  
perf. Criteria AExternal Circuit Refer to Figure 3)  
EMC  
perf. Criteria BExternal Circuit Refer to Figure 1)  
perf. Criteria BExternal Circuit Refer to Figure 3)  
perf. Criteria BExternal Circuit Refer to Figure 3)  
perf. Criteria AExternal Circuit Refer to Figure 3)  
perf. Criteria A  
EFT  
EMS  
Surge  
CS  
PFM  
Voltage dipsshort and  
interruptions immunity  
IEC/EN61000-4-11 0%-70%  
perf. Criteria B  
UL94V-0  
Case material  
Install  
PCB  
>300,000h @25℃  
MTBF  
Note:  
1.  
2.  
3.  
4.  
External electrolytic capacitor are required to models when AC input, more details refer to typical applications.  
Ripple and Noise were measured by the method of anear measure (more details refer to the anear measure).  
All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.  
In this datasheet, all the test methods of indications are based on corporate standards.  
ANEAR MEASURE  
Connect Oscillograph Probe  
Copper sheet  
FUSE  
L
Load  
N
Note: C1: 1µF (Ceramic capacitor) C2: 10µF (Electrolytic capacitor)  
PRODUCT TYPICAL CURVE  
Temperature VS Load  
Input Voltage VS Load  
Load(%)  
100  
Load(%)  
100  
80  
60  
40  
80  
60  
40  
-40 -20  
Temperature(  
55 85  
Vdc  
Vac  
70 100  
85 110  
340 400  
240 264  
)
The copyright and authority for the interpretation of the products are reserved by MORNSUN  
Specifications subject to change without notice.  
LS01 series A/0-2012 Page 2 of 4  
LS01 DC input rated load efficiency cure  
80  
LS01 DC input efficiency cure  
80  
75  
70  
65  
60  
55  
50  
45  
40  
35  
30  
25  
75  
70  
65  
60  
55  
LS01-15B05S  
LS01-15B09S  
LS01-15B12S  
LS01-15B15S  
LS01-15B24S  
100VDC  
200VDC  
300VDC  
400VDC  
.
100 150 200 250 300 350 400  
Input Voltage(VDC)  
10 20 30 40 50 60 70 80 90 100  
Load(%)  
LS01 AC input rated load efficiency cure  
LS01 AC input efficiency cure  
80  
80  
75  
70  
65  
60  
55  
50  
45  
40  
35  
30  
25  
85VAC  
LS01-15B05S  
LS01-15B09S  
LS01-15B12S  
LS01-15B15S  
LS01-15B24S  
75  
70  
65  
60  
55  
110VAC  
230VAC  
264VAC  
85  
110  
120  
220  
230  
240  
264  
10 20 30 40 50 60 70 80 90 100  
Load (%)  
Input Voltage(VAC)  
STRUCTURE FIGURE  
3
12  
+Vin(L)  
-Vin(N)  
+Vo  
Rectifier  
filter  
circuit  
DC/DC  
Convertor  
Rectificate  
1
7
10  
-Vo  
GND  
External  
Capacitor  
C1  
+
+CAP  
5
TYPICAL APPLICATIONS  
L
L
+Vo  
AC-DC  
-Vo  
+Vo  
-Vo  
FUSE  
NTC  
+Vo  
12  
C2 C3 TVS RL  
+
L
3
5
C1  
+
MOV  
AC-DC  
N
N
7
1
10  
-Vo  
N
PE  
Figure 1LS01-15BXXS  
Figure 2Note: This application is not supported for this series.  
can use MORNSUNs FC-L01D  
FUSE  
R2  
L
L
CY1  
CY2  
CY3  
R3  
MOV  
R1  
CX  
C1  
+
OUTPUT  
AC-DC  
5
7
CY4  
N
N
LCM  
PE  
Figure 3LS01 series Recommended circuit for application require higher EMC standard  
(external circuit output same as above)  
The copyright and authority for the interpretation of the products are reserved by MORNSUN  
Specifications subject to change without notice.  
LS01 series  
A/0-2012  
Page 3 of 4  
Figure 4EMC application circuit PCB layout  
Safety and recommend wiring: linewidth A3mm  
EXTERNAL CAPACITORS TYPICAL VALUE  
Output Voltage  
C1  
C2  
C3  
FUSE  
TVS  
5V  
9V  
470µF/35V  
SMBJ7.0A  
SMBJ12A  
1µF/50V  
(Ceramic capacitor)  
12V  
15V  
24V  
10µF-22µF /400V  
150µF/35V  
100µF/35V  
1A/250V  
SMBJ20A  
SMBJ30A  
Note:  
1.  
C1:AC input, is filtering electrolytic capacitor (which is required), when input voltage is below 100VAC, and the value of C1 is 10µF-22μF/400V.  
DC input, is a filtering capacitor in EMC Filter, the value of C1 is 10µF/400V(when input voltage is above 370VDC, and the value of C1 is 10µF/450V), If  
EMC performance is not required,C1 could not need.  
2.  
3.  
Output filtering capacitor C2 (which is required when AC input or DC input) is recommended to use high frequency and low impedance electrolytic capacitors.  
For capacitance and current of capacitor please refer to manufactures datasheet. Voltage derating of capacitor should be 80% or above. C3 is ceramic  
capacitor, it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (if converter fails). External input NTC is  
recommended to use 5D-9.  
For standard EMC requirement, please refer to figure 1 , if higher EMC requirement ,please refer to figure 3.  
MOV: Varistor, model: 561KD14it is used to protect the device under surge;  
R1 R22Ω/3W Winding resistor;  
R31MΩ/2W ;  
CY1CY2CY3CY41nF/400VAC;  
CX0.22µF /275VAC;  
LCM10mH-30mH;  
FC-L01DMornsuns 2KV/4KV Surge protector.  
FUSE: 1A/250V  
4.  
OUTLINE DIMENSIONS & FOOTPRINT DETAILS  
MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT  
PACKAGING DIAGRAM  
SIP Package  
(Front View)  
1
3
5
7
10 12  
1
3
5
7
10 12  
Φ1.30  
[0.051]  
0.84[0.033]  
2.54[0.100]  
5.08[0.200]  
Note: grid 2.54*2.54mm.  
7.62[0.300]  
(Bottom View)  
FOOTPRINT DETAILS  
Function  
-Vin(N)  
+Vin(L)  
+CAP  
GND  
Pin  
1
Inner box dimensions: L*W*H=355*192*93mm  
Packaging quantity: 100pcs  
Outer box dimensions: L*W*H=405*380*305mm  
Packaging quantity: 600pcs  
Max35.00[1.378]  
3
5
7
Note:  
10  
12  
-Vo  
Unit: mm[inch]  
Pin section tolerances: ±0.10mm[±0.004inch]  
General tolerances: ±0.50mm[ ± 0.020inch]  
+Vo  
MORNSUN Science & Technology Co.,Ltd.  
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.  
Tel: 86-20-28203030  
Fax:86-20-38601272  
Http://www.mornsun-power.com  
The copyright and authority for the interpretation of the products are reserved by MORNSUN  
Specifications subject to change without notice.  
LS01 series A/0-2012 Page 4 of 4  

相关型号:

LS01-15B12S-F

AC-DC Regulated Power Supply Module
MORNSUN

LS01-15B15S

LS01 Series ----- are high efficiency green power modules with miniature packaging provided by Mornsun.
MORNSUN

LS01-15B15SS

暂无描述
MORNSUN

LS01-15B24S

LS01 Series ----- are high efficiency green power modules with miniature packaging provided by Mornsun.
MORNSUN

LS01-15B24SS

暂无描述
MORNSUN

LS01-1A66-PA-500W

Level Sensors with Magnetic Floats
MEDER

LS01-1A66-PA-500W_DE

(deutsch) LS Level Sensor
MEDER

LS01-1A66-PA-700W

LS Level Sensor
MEDER

LS01-1A66-PA-700W_DE

(deutsch) LS Level Sensor
MEDER

LS01-1A66-PP-1000W

LS Level Sensor
MEDER

LS01-1A66-PP-1000W_DE

(deutsch) LS Level Sensor
MEDER

LS01-1A66-PP-1500W

LS Level Sensor
MEDER