IF1205XT-1WR2 [MORNSUN]
DC-DC Regulated Power Supply Module;型号: | IF1205XT-1WR2 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DC-DC Regulated Power Supply Module |
文件: | 总4页 (文件大小:274K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
IF_XT-1WR2 series
1W, Fixed input voltage , isolated & regulated single output
FEATURES
Efficiency up to 75%
Isolation voltage: 3K VDC
Operating temperature range: -40℃to +85℃
Miniature SMD package
Surface mounted design
No external components
International standard pin-out
Patent Protection RoHS
IF_XT-1WR2 series is specially designed for applications where an isolated voltage is required in a distributed power supply system.It is suitable for:
1.Where the voltage of the input power supply is stable (voltage variation: ±5%Vin);
2.Where isolation is necessary between input and output (isolation voltage ≤3000VDC);
3.Where has high requirement of line regulation, load regulation and the ripple & noise of the output voltage.
Selection Guide
Input Voltage (VDC)
Output
Output Current (mA)
Efficiency
(%,Min./Typ.)
@ Full Load
Max. Capacitive Load
(µF)
Part No.
Nominal
(Range)
Output Voltage
(VDC)
(Max./Min.)
243/25
200/20
83/9
IF0503XT-1WR2
IF0505XT-1WR2
IF0512XT-1WR2
IF0515XT-1WR2
IF1205XT-1WR2
IF1212XT-1WR2
IF2405XT-1WR2
IF2412XT-1WR2
3.3
54/58
68/72
69/73
70/74
69/73
69/73
69/73
69/73
5
12
15
5
5
(4.75-5.25)
67/7
220
200/20
83/9
12
(11.4-12.6)
12
5
200/20
83/9
24
(22.8-25.2)
12
Input Specifications
Item
Operating Conditions
Min.
--
Typ.
270/15
115/10
56/7
--
Max.
--
Unit
mA
5V input
12V input
24V input
5V input
--
--
Input Current (full load / no-load)
Surge Voltage (1sec. max.)
--
--
-0.7
-0.7
-0.7
--
9
--
18
30
--
VDC
mA
12V input
24V input
--
15
Reflected Ripple Current
Input Filter
Capacitance Filter
Output Specifications
Item
Operating Conditions
100% load
Min.
--
Typ.
--
Max.
±3
Unit
%
Output Voltage Accuracy
Line Regulation
--
--
±0.25
3
Input voltage change: ±1%
--
--
3.3VDC output
Other output
Load Regulation
10%-100% load
--
--
2
--
10
--
Ripple*
Noise*
mVp-p
20MHz bandwidth
100% load
--
--
50
--
--
±0.03
%/℃
Temperature Coefficient
Short Circuit Protection
Continuous, self-recovery
Note: * Ripple and noise tested with “parallel cable” method, please see DC-DC Converter Application Notes for specific operation methods.
PowerPax UK Ltd
Unit 5 Kennet Weir Business Park, Arrowhead Road, Theale, Berkshire, RG7 4AD, United Kingdom
Tel: +44 (0) 118 9033290
info@powerpaxuk.com
Fax: +44 (0) 118 9033291
Website: www.mornsun.co.uk
DC/DC Converter
IF_XT-1WR2 series
General Specifications
Item
Operating Conditions
Min.
Typ.
--
Max.
--
Unit
Input-output, with the test time of 1 minute and the leak
current lower than 1mA
3000
VDC
Isolation Voltage
1000
--
--
--
--
MΩ
Isolation Resistance
Isolation Capacitance
Input-output, isolation Voltage 500VDC
Input-output, 100KHz/0.1V
20
pF
Derating when operating temperature up to 71℃, (see Fig.
1)
-40
-55
--
--
--
85
125
--
Operating Temperature
Storage Temperature
℃
25
--
Casing Temperature Rise
Pin Welding Resistance Temperature
Ta =25℃
--
300
Welding spot is 1.5mm away from the casing, 10 seconds
Peak temp.≤245℃, maximum duration
time≤60s at 217℃.
For actual application, please refer to
IPC/JEDEC J-STD-020D.1.
Reflow Soldering Temperature
--
--
--
100
--
95
%
Storage Humidity
Switching Frequency
MTBF
Non-condensing
KHz
100% load, nominal input voltage
MIL-HDFK-217F@25℃
300
--
3500
K hours
Physical Specifications
Casing Material
Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions
15.24*11.20*7.25mm
Weight
2.0g(Typ.)
Cooling Method
Free air convection
EMC Specifications
Conducted disturbance
CISPR22/EN55022 CLASS B (see Fig. 3 for recommended circuit)
CISPR22/EN55022 CLASS B (see Fig. 3 for recommended circuit)
EMI
Radiated emission
EMS
Electrostatic discharge
IEC/EN61000-4-2 Contact ±6KV
perf. Criteria B
Product Characteristic Curve
Te mpe ra ture De ra ting Gra p h
120
100
80
60
Sa fe Op e ra ting Are a
40
20
0
71
85
120
-40
0
40
℃
Am bient Te mp .(
)
Fig. 1
Efficiency VsInput Voltage(Full Load)
Efficiency VsOutput Load(Vin=Vin-nominal)
100
100
90
80
70
60
50
40
30
20
10
0
95
90
85
80
75
70
65
60
55
50
IF0505XT-1WR2
IF0505XT-1WR2
10 20 30 40 50 60 70 80 90 100
Output Current Percentage(%)
Input Voltage(V)
PowerPax UK Ltd
Unit 5 Kennet Weir Business Park, Arrowhead Road, Theale, Berkshire, RG7 4AD, United Kingdom
Tel: +44 (0) 118 9033290
info@powerpaxuk.com
Fax: +44 (0) 118 9033291
Website: www.mornsun.co.uk
DC/DC Converter
IF_XT-1WR2 series
Efficiency VsInput Voltage(Full Load)
Efficiency VsOutput Load(Vin=Vin-nominal)
100
95
90
85
80
75
70
65
60
55
50
100
90
80
70
60
50
40
30
20
10
0
IF1205XT-1WR2
IF1205XT-1WR2
10 20 30 40 50 60 70 80 90 100
Output Current Percentage(%)
Input Voltage(V)
Design Reference
1. Typical application
If it is required to further reduce input and output ripple, a filter capacitor can be connected to the input and output terminals, see Fig.2.
Moreover, choosing suitable filter capacitor is very important , start-up problems may be caused by too large capacitance.To ensured the modules
running well, the recommended capacitive load values as shown in Table 1.
Recommended capacitive load value table (Table 1)
Vin(VDC)
Cin(µF)
Vo (VDC)
Cout(µF)
+Vo
0V
5
12
24
4.7
2.2
1
3.3/5
12
15
10
2.2
1
Vin
Cout
Cin
DC
Fig.2
DC
GND
It is not recommended to connect any external capacitor when output
power is less than 0.5W.
2. EMC typical recommended circuit
Input voltage (V)
C1
5/12/24
4.7µF /50V
LDM
EMI
C2
Refer to the Cout in Fig.2
Vin
Vin
+Vo
LDM
6.8µH
Note: It is not needed to add the component in the peripheral circuit when
parameter with the symbol of "--"
DCDC
LOAD
C1
C2
GND
GND
0V
Fig. 3
3. Output load requirements
To ensure the module work efficiently and reliably, during the operation, the min. output load should be no less than 10% of the full load. If the actual
output power is low, please connect a resister to the output terminal in parallel, with a recommenced resistance which is 10% of the rated power, and
derating is required during operation.
4. For more information please find DC-DC converter application notes on www.mornsun-power.com
Dimensions and Recommended Layout
PowerPax UK Ltd
Unit 5 Kennet Weir Business Park, Arrowhead Road, Theale, Berkshire, RG7 4AD, United Kingdom
Tel: +44 (0) 118 9033290
info@powerpaxuk.com
Fax: +44 (0) 118 9033291
Website: www.mornsun.co.uk
DC/DC Converter
IF_XT-1WR2 series
Notes:
1. Packing information please refer to "Product Packing Information".Packing bag number: 58210023;
2. If the product is operated out of the min. load requirement, the product performance may not meet all parameter indexes in this datasheet;
3. The max. capacitive load offered is tested at nominal input voltage and full load;
4. Unless otherwise specified,parameter indexes in this datasheet is measured under the conditions of Ta=25℃, humidity<75% with nominal input
voltage and rated output load;
5. All testing methods in this datasheet are based on our Company’s corporate standards;
6. The parameter indexes above are for the modules listed in this datasheet, for non-standard module's parameter indexes, please contact our
technicians for specific information;
7. We can provide custom design;
8. Specifications are subject to change without prior notice.
PowerPax UK Ltd
Unit 5 Kennet Weir Business Park, Arrowhead Road, Theale, Berkshire, RG7 4AD, United Kingdom
Tel: +44 (0) 118 9033290
info@powerpaxuk.com
Fax: +44 (0) 118 9033291
Website: www.mornsun.co.uk