MGWI06-48D05 [MINMAX]
DC/DC CONVERTER 6W, Ultra compact DIP Package;型号: | MGWI06-48D05 |
厂家: | MINMAX TECHNOLOGY CO., LTD. |
描述: | DC/DC CONVERTER 6W, Ultra compact DIP Package |
文件: | 总4页 (文件大小:284K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
FEATURES
►Ultra compact DIP Package
21.6 x 20.3 x 10.2 mm (0.85 x 0.80 x 0.40 inches)
►Ultra wide 4:1 Input Range
►Fully regulated Output
►Operating Temp. Range –40°C to +85°C
►Over Load Protection
►Remote On/Off Control
►I/O-isolation 1500 VDC
►Input Filter complies with EN55022,class A
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MGWI06 series is a new range of isolated 6W DC/DC converter modules featuring fully regulated output voltages and ultra-wide 4:1 input
voltage ranges. These products are with a very small footprint occupying just 4.5cm2 (0.7 square in.) on PCB. An excellent efficiency allows an operating
temperature range of –40° to +85°C. Further features include remote On/Off control and over load protection.
The very compact dimensions of these DC/DC converters make them an ideal solution for many space critical applications in battery-powered equipment
and instrumentation.
Model Selection Guide
Model
Input
Voltage
(Range)
VDC
Output
Output
Input Current
Max. capacitive
Load
Efficiency
(typ.)
Number
Voltage
Current
@Max. Load
@No Load
mA(typ.)
Max.
Min.
@Max. Load
VDC
3.3
5
12
15
mA
1450
1200
500
400
250
±600
±250
±200
1450
1200
500
400
250
±600
±250
±200
mA
218
180
75
60
38
±90
±38
±30
218
180
75
60
38
±90
±38
±30
mA(typ.)
262
316
301
301
301
301
301
301
131
158
151
151
151
151
151
151
uF
%
76
79
83
83
83
82
83
83
76
79
83
83
83
82
83
83
MGWI06-24S033
MGWI06-24S05
MGWI06-24S12
MGWI06-24S15
MGWI06-24S24
MGWI06-24D05
MGWI06-24D12
MGWI06-24D15
MGWI06-48S033
MGWI06-48S05
MGWI06-48S12
MGWI06-48S15
MGWI06-48S24
MGWI06-48D05
MGWI06-48D12
MGWI06-48D15
330
100
24
(9 ~ 36)
30
24
±5
±12
±15
3.3
5
12
15
24
100#
330
100
48
(18 ~ 75)
20
±5
±12
±15
100#
# For each output
Input Specifications
Parameter
Model
Min.
-0.7
-0.7
---
Typ.
Max.
50
Unit
VDC
mW
24V Input Models
48V Input Models
24V Input Models
48V Input Models
24V Input Models
48V Input Models
---
---
---
---
---
---
---
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
100
9
---
18
---
8.5
17
Under Voltage Shutdown
---
Short Circuit Input Power
Conducted EMI
---
3000
All Models
Compliance to EN 55022,class A and FCC part 15,class A
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/11/22 REV:6
Page 1 of 4
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Output Specifications
Parameter
Conditions
Min.
---
Typ.
±1.0
±1.0
±0.5
±0.5
60
Max.
±2.0
---
Unit
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output, Balanced Loads
Vin=Min. to Max.
---
%
---
±1.0
±1.2
100
150
600
---
%
Io=15% to 100%
Load Regulation
---
%
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
---
mV P-P
mV P-P
uS
Over Line, Load & Temp.
25% Load Step Change
---
---
---
300
±3
---
%
---
±0.01
150
±0.02
---
%/℃
%
Foldback
110
Continuous
General Specifications
Parameter
Conditions
60 Seconds
500 VDC
Min.
1500
1000
---
Typ.
---
Max.
---
Unit
VDC
MΩ
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
---
---
100KHz, 1V
1200
330
---
1500
---
pF
---
KHz
Hours
MIL-HDBK-217F@25℃, Ground Benign
350,000
---
Safety Approvals(pending)
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Input Fuse
24V Input Models
48V Input Models
1500mA Slow-Blow Type
750mA Slow-Blow Type
Remote On/Off Control
Parameter
Conditions
Min.
Typ.
Max.
Unit
Converter On
Converter Off
2.5V ~ 50VDC or Open Circuit
-0.7V ~ 0.8V
Control Input Current (on)
Control Input Current (off)
Control Common
Vin-RC=5V
Vin-RC=0V
---
---
---
500
uA
uA
---
-500
Referenced to Negative Input
---
Standby Input Current
---
10
mA
Environmental Specifications
Parameter
Conditions
Ambient
Min.
Max.
+85
Unit
-40
℃
℃
℃
Operating Temperature Range (with Derating)
Case Temperature
---
+105
+125
95
-50
Storage Temperature Range
Humidity (non condensing)
Cooling
---
% rel. H
Free-Air convection
---
Lead Temperature (1.5mm from case for 10Sec.)
260
℃
Power Derating Curve
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/11/22 REV:6
Page 2 of 4
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Notes
1
2
3
4
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
5
6
7
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
Specifications subject to change without notice.
Package Specifications
Mechanical Dimensions
Pin Connections
Pin
Single Output
Dual Output
Remote On/Off
-Vin
1
2
Remote On/Off
-Vin
NC
6
Common
-Vout
8
NC
9
+Vout
-Vout
+Vin
+Vout
0.50 [0.02]
11
16
Common
+Vin
2.54
[0.10]
10.16 [0.40]
NC: No Connection
1
2
6
8
9
Bottom View
11
16
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
12.7 [0.50] 5.08
1.9
[0.20]
[0.08]
X.XX±0.13 ( X.XXX±0.005)
21.6 [0.85]
►Pin diameter 0.5 ±0.05 (0.02±0.002)
Physical Characteristics
Case Size
Case Material
Weight
:
:
:
21.6x20.3x10.2 mm (0.85x0.8x0.4 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
9.1g
E-mail:sales@minmax.com.tw
Tel:886-6-2923150
2011/11/22 REV:6
Page 3 of 4
®
MGWI06 SERIES
DC/DC CONVERTER 6W, DIP Package
Test Configurations
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
Copper Strip
Cout
+Vin
+Out
-Out
Copper Strip
+Vin
+Out
Com.
-Out
Scope
Scope
Single Output
DC / DC
Converter
Dual Output
DC / DC
Converter
Resistive
Load
Resistive
Load
Cout
Scope
Copper Strip
Cout
-Vin
Copper Strip
-Vin
Copper Strip
Design & Feature Considerations
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.
A logic low is -0.7V to 0.8V. A logic high is 2.5V to 50V. The maximum sink current of the switch at on/off terminal during a logic low is -500 uA.
The maximum sink current of the switch at on/off terminal during a logic high is 500uA or open.
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <
1.0Ω at 100 KHz) capacitor of a 4.7uF for the 24V input devices and a 2.2uF for the 48V devices.
+
+Vin
+Out
+
DC / DC
Converter
DC Power
Source
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
+Vin
-Vin
+Out
+
+Vin
+Out
Com.
-Out
Single Output
DC / DC
Converter
Load
Load
Dual Output
DC / DC
Converter
DC Power
Source
Cout
Cout
DC Power
Source
Cout
Load
-
-Out
-
-Vin
Maximum Capacitive Load
The MGWI06 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
Air Flow
50mm / 2in
15mm / 0.6in
DUT
Minmax Technology Co., Ltd.
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw
2011/11/22 REV:6
Page 4 of 4