MBU100_13 [MINMAX]

DC/DC CONVERTER 1W Miniature SIP-Package with Industry Standard Pinout; DC / DC转换器1W微型SIP的封装与国际标准引脚
MBU100_13
型号: MBU100_13
厂家: MINMAX TECHNOLOGY CO., LTD.    MINMAX TECHNOLOGY CO., LTD.
描述:

DC/DC CONVERTER 1W Miniature SIP-Package with Industry Standard Pinout
DC / DC转换器1W微型SIP的封装与国际标准引脚

转换器
文件: 总4页 (文件大小:516K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MBU100 SERIES  
DC/DC CONVERTER 1W, SIP-Package  
FEATURES  
Miniature SIP-Package with Industry Standard Pinout  
Package Dimension:  
11.5 x 10.2 x *6.1 mm (0.45”x 0.40”x 0.24”) 3.3V,5V&12V Models  
11.5 x 10.2 x *7.1 mm (0.45”x 0.40”x 0.28”) 24V Models  
Single and Dual Output Models  
I/O-Isolation 1000 VDC  
Operating Temp. Range -40°C to +85°C  
3 Years Product Warranty  
PRODUCT OVERVIEW  
The MINMAX MBU100 series is a range of 1W DC/DC converters in a miniature SIP Package featuring I/O-isolation of 1000VDC.  
A high efficiency allows an operating temperature range of –40°C to +85°C.  
These converters offer an economical solution for many space critical applications where a voltage has to be isolated i.e for noise reduction, ground loop  
elimination, digital interfaces or for board level power distribution.  
Model Selection Guide  
Model  
Input  
Output  
Output Current  
Input Current  
Load  
Max. capacitive  
Load  
Efficiency  
(typ.)  
Number  
Voltage  
(Range)  
Voltage  
Regulation  
@Max. Load  
@No Load  
mA(typ.)  
Max.  
Min.  
@Max. Load  
VDC  
3.3  
VDC  
3.3  
5
mA  
260  
200  
260  
200  
110  
84  
mA  
6
mA(typ.)  
351  
394  
238  
290  
260  
262  
258  
117  
107  
106  
105  
60  
% (max.)  
µF  
33  
%
74  
77  
72  
69  
76  
77  
78  
71  
77  
79  
80  
70  
76  
79  
79  
MBU135  
MBU131  
MBU105  
MBU101  
MBU102  
MBU103  
MBU104  
MBU111  
MBU112  
MBU113  
MBU114  
MBU121  
MBU122  
MBU123  
MBU124  
14  
14  
11  
11  
8
35  
(2.97 ~ 3.63)  
4
3.3  
5
6
4
5
(4.5 ~ 5.5)  
9
2
30  
33  
12  
15  
5
1.5  
1
7
67  
6
200  
110  
84  
4
9
12  
(10.8 ~ 13.2)  
9
2
5
13  
7
33  
33  
12  
15  
5
1.5  
1
5
67  
4
200  
110  
84  
4
8
24  
9
2
54  
5
(21.6 ~ 26.4)  
12  
15  
1.5  
1
53  
4
67  
53  
4
Input Specifications  
Parameter  
Model  
Min.  
Typ.  
3.3  
5
Max.  
3.63  
5.5  
13.2  
26.4  
6
Unit  
3.3V Input Models  
5V Input Models  
12V Input Models  
24V Input Models  
3.3V Input Models  
5V Input Models  
12V Input Models  
24V Input Models  
2.97  
4.5  
Input Voltage Range  
10.8  
21.6  
-0.7  
-0.7  
-0.7  
-0.7  
---  
12  
24  
---  
VDC  
---  
9
Input Surge Voltage (1 sec. max.)  
---  
18  
---  
30  
Reverse Polarity Input Current  
Internal Filter Type  
---  
0.3  
A
All Models  
Internal Capacitor  
Internal Power Dissipation  
---  
---  
450  
mW  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/01/24 REV:5 Page 1 of 4  
MBU100 SERIES  
DC/DC CONVERTER 1W, SIP-Package  
Output Specifications  
Parameter  
Conditions  
Min.  
---  
Typ.  
1.0  
Max.  
3.0  
Unit  
%
Output Voltage Accuracy  
Line Regulation  
For Vin Change of 1%  
Io=20% to 100%  
---  
1.2  
1.5  
%
Load Regulation  
See Model Selection Guide  
Ripple & Noise  
max. 20MHz Bandwidth  
---  
---  
100  
150  
mVP-P  
Temperature Coefficient  
Short Circuit Protection  
0.01  
0.02  
%/  
0.5 Second Max.  
General Specifications  
Parameter  
Conditions  
60 Seconds  
500 VDC  
Min.  
1000  
1000  
---  
Typ.  
---  
Max.  
---  
Unit  
VDC  
MΩ  
I/O Isolation Voltage (rated)  
I/O Isolation Resistance  
I/O Isolation Capacitance  
Switching Frequency  
MTBF (calculated)  
---  
---  
100KHz, 1V  
60  
90  
---  
100  
110  
---  
pF  
50  
KHz  
Hours  
MIL-HDBK-217F@25, Ground Benign  
2,000,000  
Input Fuse  
3.3V Input Models  
800mA Slow-Blow Type  
5V Input Models  
12V Input Models  
200mA Slow-Blow Type  
24V Input Models  
500mA Slow-Blow Type  
100mA Slow-Blow Type  
Environmental Specifications  
Parameter  
Conditions  
Ambient  
Min.  
-40  
---  
Max.  
+85  
+90  
+125  
95  
Unit  
Operating Ambient Temperature Range (See Power Derating Curve)  
Case Temperature  
Storage Temperature Range  
-50  
---  
Humidity (non condensing)  
% rel. H  
Cooling  
Free-Air convection  
---  
Lead Temperature (1.5mm from case for 10Sec.)  
260  
Power Derating Curve  
(5V Output Only)  
(All Other Output)  
Notes  
1
2
3
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.  
Ripple & Noise measurement bandwidth is 0-20MHz.  
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these  
modules; however they may not meet all specifications listed.  
4
5
6
7
All DC/DC converters should be externally fused at the front end for protection.  
Other input and output voltage may be available, please contact factory.  
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).  
Specifications are subject to change without notice.  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/01/24 REV:5 Page 2 of 4  
MBU100 SERIES  
DC/DC CONVERTER 1W, SIP-Package  
Package Specifications  
Mechanical Dimensions  
Pin Connections  
Pin  
1
Function  
-Vin  
11.5 [0.45]  
2
+Vin  
3
-Vout  
+Vout  
4
0.5  
T: 6.1mm(0.24 inch) for 3.3V&5V&12V Input Models  
T: 7.1mm(0.28 inch) for 24V Input Models  
[0.02]  
1.9  
3X2.54  
[0.07]  
[3X0.10]  
10.5 [0.41]  
All dimensions in mm (inches)  
Tolerance: X.X 0.25 (X.XX 0.01)  
X.XX 0.13 ( X.XXX 0.005)  
Pins 0.05( 0.002)  
1
2
3
4
Bottom View  
0.50  
[0.02]  
Physical Characteristics  
Case Size(3.3V, 5V, 12V Input)  
Case Size(24V Input)  
:
:
11.5x6.1x10.2mm (0.45x0.24x0.40 inches)  
11.5x7.1x10.2mm (0.45x0.28x0.40 inches)  
Case Material  
Pin Material  
:
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)  
Alloy 42  
Weight(3.3V, 5V, 12V Input)  
Weight(24V Input)  
:
:
1.3g  
1.7g  
E-mail:sales@minmax.com.tw Tel:886-6-2923150  
2013/01/24 REV:5 Page 3 of 4  
MBU100 SERIES  
DC/DC CONVERTER 1W, SIP-Package  
Test Setup  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between  
50 mm and 75 mm from the DC/DC Converter.  
+Vin  
+Out  
-Out  
Copper Strip  
Cout  
Single Output  
DC / DC  
Converter  
Resistive  
Load  
Scope  
-Vin  
Copper Strip  
Technical Notes  
Maximum Capacitive Load  
The MBU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. For optimum performance we recommend 33µF maximum capacitive load for devices. The maximum capacitance can  
be found in the data sheet.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In  
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
Capacitor mounted close to the power module helps ensure stability of the unit, it is comended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at  
100 KHz) capacitor of a 2.2µF for the 3.3V, 5V input devices, a 1.0µF for the 12V input devices and a 0.47µF for the 24V devices.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 1µF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
Single Output  
DC / DC  
Converter  
DC Power  
Source  
Cout  
Load  
-
-Out  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 90. The derating curves are determined from  
measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Minmax Technology Co., Ltd.  
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan  
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw  
2013/01/24 REV:5  
Page 4 of 4  

相关型号:

MBU101

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER

MBU101

1W, Ultra Miniature SIP, Single Output DC/DC Converter
MINMAX

MBU102

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER

MBU102

1W, Ultra Miniature SIP, Single Output DC/DC Converter
MINMAX

MBU103

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER

MBU103

1W, Ultra Miniature SIP, Single Output DC/DC Converter
MINMAX

MBU104

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER

MBU104

1W, Ultra Miniature SIP, Single Output DC/DC Converter
MINMAX

MBU105

DC/DC CONVERTER 1W Miniature SIP-Package with Industry Standard Pinout
MINMAX

MBU111

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER

MBU111

1W, Ultra Miniature SIP, Single Output DC/DC Converter
MINMAX

MBU112

MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
TOTAL-POWER