MT9044  
T1/E1/OC3 System Synchronizer  
Advance Information  
DS5058  
ISSUE 3  
September 1999  
Features  
Supports AT&T TR62411 and Bellcore  
Ordering Information  
GR-1244-CORE Stratum 3, Stratum 4  
Enhanced and Stratum 4 timing for DS1  
interfaces  
MT9044AP  
MT9044AL  
44 Pin PLCC  
44 Pin MQFP  
Supports ITU-T G.812 Type IV clocks for 1,544  
kbit/s interfaces and 2,048 kbit/s interfaces  
-40 to +85 °C  
Description  
Supports ETSI ETS 300 011, TBR 4, TBR 12  
and TBR 13 timing for E1 interfaces  
The MT9044 T1/E1/OC3 System Synchronizer  
contains a digital phase-locked loop (DPLL), which  
provides timing and synchronization signals for  
multitrunk T1 and E1 primary rate transmission links  
and STS-3/0C3 links.  
Selectable 1.544MHz, 2.048MHz or 8kHz input  
reference signals  
Provides C1.5, C2, C3, C4, C6, C8, C16, and  
C19 (STS-3/OC3 clock divided by 8) output  
clock signals  
The MT9044 generates ST-BUS clock and framing  
signals that are phase locked to either a 2.048MHz,  
1.544MHz, or 8kHz input reference.  
Provides 5 different styles of 8 KHz framing  
pulses  
Holdover frequency accuracy of 0.05 PPM  
Holdover indication  
The MT9044 is compliant with AT&T TR62411 and  
Bellcore GR-1244-CORE Stratum 3, Stratum 4  
Enhanced, and Stratum 4; and ETSI ETS 300 011. It  
will meet the jitter/wander tolerance, jitter/wander  
transfer, intrinsic jitter/wander, frequency accuracy,  
capture range, phase change slope, holdover  
frequency and MTIE requirements for these  
specifications.  
Attenuates wander from 1.9Hz  
Provides Time Interval Error (TIE) correction  
Accepts reference inputs from two independent  
sources  
JTAG Boundary Scan  
Applications  
Synchronization and timing control for  
multitrunk T1,E1 and STS-3/OC3 systems  
ST-BUS clock and frame pulse sources  
OSCi  
OSCo  
TCLR  
VDD  
VSS  
C19o  
Master Clock  
Virtual  
C1.5o  
TIE  
Reference  
TCK  
C3o  
C2o  
C4o  
C6o  
C8o  
C16o  
F0o  
F8o  
F16o  
RSP  
Corrector  
Circuit  
DPLL  
TDI  
TMS  
TRST  
TDO  
IEEE  
1149.1a  
Output  
Interface  
Circuit  
Selected  
State  
Select  
Reference  
Reference  
Select  
MUX  
PRI  
SEC  
Input  
Impairment  
Monitor  
TIE  
Corrector  
Enable  
State  
Select  
Reference  
Select  
TSP  
Feedback  
Frequency  
Select  
MUX  
RSEL  
LOS1  
LOS2  
Automatic/Manual  
Control State Machine  
Guard Time  
Circuit  
ACKi  
APLL  
ACKo  
MS1  
MS2  
RST HOLDOVER  
GTo  
GTi  
FS1  
FS2  
Figure 1 - Functional Block Diagram  
1
MT9044  
Advance Information  
44 43 42 41 40 3938 37 36 35 34  
6
5 4 3 2 1 44 43 42 41 40  
TEST  
RSEL  
MS1  
MS2  
TDO  
LOS1  
LOS2  
GTo  
VSS  
GTi  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
1
2
3
4
5
6
7
8
9
VDD  
OSCo  
OSCi  
VSS  
F16o  
RSP  
F0o  
VDD  
OSCo  
OSCi  
VSS  
F16o  
RSP  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
TEST  
RSEL  
MS1  
MS2  
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
TDO  
MT9044AL  
MT9044  
LOS1  
LOS2  
GTo  
VSS  
GTi  
F0o  
TSP  
F8o  
TSP  
F8o  
C1.5o  
10  
11  
C1.5o  
HOLDOVER  
AVDD  
HOLDOVER  
AVDD  
12 13 14 15 16 17 18 19 20 21 22  
18 19 20 21 22 23 24 25 26 27 28  
Figure 2 - Pin Connections  
Pin Description  
Pin # Pin #  
PLCC MQFP  
Name  
Description  
1,10, 39,4,17  
VSS  
Ground. 0 Volts.  
23,31  
,25  
2
40  
TCK  
Test Clock (TTL Input): Provides the clock to the JTAG test logic. This pin is  
internally pulled up to V  
.
DD  
3
41  
TCLR  
TIE Circuit Reset (TTL Input): A logic low at this input resets the Time Interval  
Error (TIE) correction circuit resulting in a re-alignment of input phase with output  
phase as shown in Figure 19. The TCLR pin should be held low for a minimum of  
300ns. This pin is internally pulled down to VSS.  
4
5
42  
43  
TRST  
SEC  
Test Reset (TTL Input): Asynchronously initializes the JTAG TAP controller by  
putting it in the Test-Logic-Reset state. This pin is internally pulled down to VSS.  
Secondary Reference (TTL Input). This is one of two (PRI & SEC) input  
reference sources (falling edge) used for synchronization. One of three possible  
frequencies (8kHz, 1.544MHzMHz, or 2.048MHz) may be used. The selection of  
the input reference is based upon the MS1, MS2, LOS1, LOS2, RSEL, and GTi  
control inputs (Automatic or Manual). This pin is internally pulled up to V  
.
DD  
6
44  
PRI  
Primary Reference (TTL Input). See pin description for SEC. This pin is  
internally pulled up to V  
.
DD  
7,28  
8
1,22  
2
VDD  
Positive Supply Voltage. +5V nominal.  
DC  
OSCo  
Oscillator Master Clock (CMOS Output). For crystal operation, a 20MHz crystal  
is connected from this pin to OSCi, see Figure 10. For clock oscillator operation,  
this pin is left unconnected, see Figure 9.  
9
3
5
OSCi  
F16o  
Oscillator Master Clock (CMOS Input). For crystal operation, a 20MHz crystal is  
connected from this pin to OSCo, see Figure 10. For clock oscillator operation, this  
pin is connected to a clock source, see Figure 9.  
11  
Frame Pulse ST-BUS 8.192 Mb/s (CMOS Output). This is an 8kHz 61ns active  
low framing pulse, which marks the beginning of an ST-BUS frame. This is typically  
used for ST-BUS operation at 8.192 Mb/s. See Figure 20.  
2
Advance Information  
MT9044  
Pin Description (continued)  
Pin # Pin #  
Name  
Description  
PLCC MQFP  
12  
13  
14  
15  
6
7
8
9
RSP  
F0o  
TSP  
F8o  
Receive Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing  
pulse, which marks the end of an ST-BUS frame. This is typically used for  
connection to the Siemens MUNICH-32 device. See Figure 21.  
Frame Pulse ST-BUS 2.048Mb/s (CMOS Output). This is an 8kHz 244ns active  
low framing pulse, which marks the beginning of an ST-BUS frame. This is typically  
used for ST-BUS operation at 2.048Mb/s and 4.096Mb/s. See Figure 20.  
Transmit Sync Pulse (CMOS Output). This is an 8kHz 488ns active high framing  
pulse, which marks the beginning of an ST-BUS frame. This is typically used for  
connection to the Siemens MUNICH-32 device. See Figure 21.  
Frame Pulse (CMOS Output). This is an 8kHz 122ns active high framing pulse,  
which marks the beginning of a frame. See Figure 20.  
16  
17  
18  
19  
10  
11  
12  
13  
C1.5o  
AVdd  
C3o  
Clock 1.544MHz (CMOS Output). This output is used in T1 applications.  
Analog Vdd. +5V nominal.  
DC  
Clock 3.088MHz (CMOS Output). This output is used in T1 applications.  
C2o  
Clock 2.048MHz (CMOS Output). This output is used for ST-BUS operation at  
2.048Mb/s.  
20  
14  
C4o  
Clock 4.096MHz (CMOS Output). This output is used for ST-BUS operation at  
2.048Mb/s and 4.096Mb/s.  
21  
22  
15  
16  
C19o  
ACKi  
Clock 19.44MHz (CMOS Output). This output is used in OC3/STS3 applications.  
Analog PLL Clock Input (CMOS Input). This input clock is a reference for an  
internal analog PLL. This pin is internally pulled down to VSS.  
24  
25  
26  
18  
19  
20  
ACKo  
C8o  
Analog PLL Clock Output (CMOS Output). This output clock is generated by  
the internal analog PLL.  
Clock 8.192MHz (CMOS Output). This output is used for ST-BUS operation at  
8.192Mb/s.  
C16o  
Clock 16.384MHz (CMOS Output). This output is used for ST-BUS operation with  
a 16.384MHz clock.  
27  
29  
21  
23  
C6o  
Clock 6.312 Mhz (CMOS Output). This output is used for DS2 applications.  
HOLDOVER Holdover (CMOS Output). This output goes to a logic high whenever the digital  
PLL goes into holdover mode.  
30  
24  
GTi  
Guard Time (Schmitt Input). This input is used by the MT9044 state machine in  
both Manual and Automatic modes. The signal at this pin affects the state changes  
between Primary Holdover Mode and Primary Normal Mode, and Primary  
Holdover Mode and Secondary Normal Mode. The logic level at this input is gated  
in by the rising edge of F8o. See Tables 4 and 5.  
32  
33  
26  
27  
GTo  
Guard Time (CMOS Output). The LOS1 input is gated by the rising edge of F8o,  
buffered and output on GTo. This pin is typically used to drive the GTi input through  
an RC circuit.  
LOS2  
Secondary Reference Loss (TTL Input). This input is normally connected to the  
loss of signal (LOS) output signal of a Line Interface Unit (LIU). When high, the  
SEC reference signal is lost or invalid. LOS2, along with the LOS1 and GTi inputs  
control the MT9044 state machine when operating in Automatic Control. The logic  
level at this input is gated in by the rising edge of F8o. This pin is internally pulled  
down to VSS.  
3
MT9044  
Advance Information  
Pin Description (continued)  
Pin # Pin #  
Name  
Description  
PLCC MQFP  
34  
28  
LOS1  
Primary Reference Loss (TTL Input). Typically, external equipment applies a  
logic high to this input when the PRI reference signal is lost or invalid. The logic  
level at this input is gated in by the rising edge of F8o. See LOS2 description. This  
pin is internally pulled down to VSS.  
35  
36  
29  
30  
TDO  
MS2  
Test Serial Data Out (TTL Output). JTAG serial data is output on this pin on the  
falling edge of TCK. This pin is held in high impedance state when JTAG scan is  
not enable.  
Mode/Control Select 2 (TTL Input). This input, in conjunction with MS1,  
determines the device’s mode (Automatic or Manual) and state (Normal, Holdover  
or Freerun) of operation. The logic level at this input is gated in by the rising edge  
of F8o. See Table 3.  
37  
38  
31  
32  
MS1  
Mode/Control Select 1 (TTL Input). The logic level at this input is gated in by the  
rising edge of F8o. See pin description for MS2. This pin is internally pulled down  
to VSS.  
RSEL  
Reference Source Select (TTL Input). In Manual Control, a logic low selects the  
PRI (primary) reference source as the input reference signal and a logic high  
selects the SEC (secondary) input. In Automatic Control, this pin must be at logic  
low. The logic level at this input is gated in by the rising edge of F8o. See Table 2.  
This pin is internally pulled down to VSS.  
39  
40  
33  
34  
TEST  
FS2  
Test (TTL Input). This input is normally tied low. When pulled high, it enables  
internal test modes. This pin is internally pulled down to VSS.  
Frequency Select 2 (TTL Input). This input, in conjunction with FS1, selects  
which of three possible frequencies (8kHz, 1.544MHz, or 2.048MHz) may be input  
to the PRI and SEC inputs. See Table 1.  
41  
42  
35  
36  
FS1  
TDI  
Frequency Select 1 (TTL Input). See pin description for FS2.  
Test Serial Data In (TTL Input). JTAG serial test instructions and data are shifted  
in on this pin. This pin is internally pulled up to V  
.
DD  
43  
37  
RST  
Reset (Schmitt Input). A logic low at this input resets the MT9044. To ensure  
proper operation, the device must be reset after changes to the method of control,  
reference signal frequency changes and power-up. The RST pin should be held  
low for a minimum of 300ns. While the RST pin is low, all frame and clock outputs  
are at logic high. Following a reset, the input reference source and output clocks  
and frame pulses are phase aligned as shown in Figure 19.  
44  
38  
TMS  
Test Mode Select (TTL Input). JTAG signal that controls the state transitions of  
the TAP controller. This pin is internally pulled up to V  
.
DD  
4
Advance Information  
MT9044  
Functional Description  
FS2  
FS1  
Input Frequency  
The MT9044 is a Multitrunk System Synchronizer,  
providing timing (clock) and synchronization (frame)  
signals to interface circuits for T1 and E1 Primary  
Rate Digital Transmission links.  
0
0
1
1
0
1
0
1
Reserved  
8kHz  
1.544MHz  
2.048MHz  
Figure 1 shows the functional block diagram which is  
described in the following sections.  
Table 1 - Input Frequency Selection  
Time Interval Error (TIE) Corrector Circuit  
Reference Select MUX Circuit  
The TIE corrector circuit, when enabled, prevents a  
step change in phase on the input reference signals  
(PRI or SEC) from causing a step change in phase at  
the input of the DPLL block of Figure 1.  
The MT9044 accepts two simultaneous reference  
input signals and operates on their falling edges.  
Either the primary reference (PRI) signal or the  
secondary reference (SEC) signal can be selected  
as input to the TIE Corrector Circuit. The selection is  
based on the Control, Mode and Reference  
Selection of the device. See Tables 1, 4 and 5.  
During reference input rearrangement, such as  
during a switch from the primary reference (PRI) to  
the secondary reference (SEC), a step change in  
phase on the output signals will occur. A phase step  
at the input of the DPLL will lead to unacceptable  
phase changes in the output signal.  
Frequency Select MUX Circuit  
The MT9044 operates with one of three possible  
input reference frequencies (8kHz, 1.544MHz or  
2.048MHz). The frequency select inputs (FS1 and  
FS2) determine which of the three frequencies may  
be used at the reference inputs (PRI and SEC). Both  
inputs must have the same frequency applied to  
them. A reset (RST) must be performed after every  
frequency select input change. Operation with FS1  
and FS2 both at logic low is reserved and must not  
be used. See Table 1.  
As shown in Figure 3, the TIE Corrector Circuit  
receives one of the two reference (PRI or SEC)  
signals, passes the signal through a programmable  
delay line, and uses this delayed signal as an  
internal virtual reference, which is input to the DPLL.  
Therefore, the virtual reference is a delayed version  
of the selected reference.  
During a switch, from one reference to the other, the  
State Machine first changes the mode of the device  
TCLR  
Resets Delay  
Control  
Circuit  
Control Signal  
Delay Value  
Programmable  
Delay Circuit  
Virtual  
Reference  
to DPLL  
PRI or SEC  
from  
Reference  
Select Mux  
Compare  
Circuit  
TIE Corrector  
Enable  
Feedback  
Signal from  
Frequency  
Select MUX  
from  
State Machine  
Figure 3 - TIE Corrector Circuit  
5
MT9044  
Advance Information  
from Normal to Holdover. In Holdover Mode, the  
DPLL no longer uses the virtual reference signal, but  
generates an accurate clock signal using storage  
techniques. The Compare Circuit then measures the  
phase delay between the current phase (feedback  
signal) and the phase of the new reference signal.  
This delay value is passed to the Programmable  
Delay Circuit (See Figure 3). The new virtual  
reference signal is now at the same phase position  
as the previous reference signal would have been if  
the reference switch had not taken place. The State  
Machine then returns the device to Normal Mode.  
Digital Phase Lock Loop (DPLL)  
As shown in Figure 4, the DPLL of the MT9044  
consists of a Phase Detector, Limiter, Loop Filter,  
Digitally Controlled Oscillator, and a Control Circuit.  
Phase Detector - the Phase Detector compares the  
virtual reference signal from the TIE Corrector circuit  
with the feedback signal from the Frequency Select  
MUX circuit, and provides an error signal  
corresponding to the phase difference between the  
two. This error signal is passed to the Limiter circuit.  
The Frequency Select MUX allows the proper  
feedback signal to be externally selected (e.g., 8kHz,  
1.544MHz or 2.048MHz).  
The DPLL now uses the new virtual reference signal,  
and since no phase step took place at the input of  
the DPLL, no phase step occurs at the output of the  
DPLL. In other words, reference switching will not  
create a phase change at the input of the DPLL, or at  
the output of the DPLL.  
Limiter - the Limiter receives the error signal from  
the Phase Detector and ensures that the DPLL  
responds to all input transient conditions with a  
maximum output phase slope of 5ns per 125us. This  
is well within the maximum phase slope of 7.6ns per  
125us or 81ns per 1.326ms specified by AT&T  
TR62411, and Bellcore GR-1244-CORE.  
Since internal delay circuitry maintains the alignment  
between the old virtual reference and the new virtual  
reference, a phase error may exist between the  
selected input reference signal and the output signal  
of the DPLL. This phase error is a function of the  
difference in phase between the two input reference  
signals during reference rearrangements. Each time  
a reference switch is made, the delay between input  
signal and output signal will change. The value of  
this delay is the accumulation of the error measured  
during each reference switch.  
Loop Filter - the Loop Filter is similar to a first order  
low pass filter with a 1.9 Hz cutoff frequency for all  
three reference frequency selections (8kHz,  
1.544MHz or 2.048MHz). This filter ensures that the  
jitter transfer requirements in ETS 300 011 and AT&T  
TR62411 are met.  
Control Circuit - the Control Circuit uses status and  
control information from the State Machine and the  
Input Impairment Circuit to set the mode of the  
DPLL. The three possible modes are Normal,  
Holdover and Freerun.  
The programmable delay circuit can be zeroed by  
applying a logic low pulse to the TIE Circuit Reset  
(TCLR) pin. A minimum reset pulse width is 300ns.  
This results in a phase alignment between the input  
reference signal and the output signal as shown in  
Figure 20. The speed of the phase alignment  
correction is limited to 5ns per 125us, and  
convergence is in the direction of least phase travel.  
Digitally Controlled Oscillator (DCO) - the DCO  
receives the limited and filtered signal from the Loop  
FIlter, and based on its value, generates  
a
corresponding digital output signal. The  
synchronization method of the DCO is dependent on  
the state of the MT9044.  
The state diagrams of Figure 7 and 8 indicate the  
state changes that activate the TIE Corrector Circuit.  
Phase  
Detector  
Digitally  
Controlled  
Oscillator  
Virtual Reference from  
DPLL Reference to  
Output Interface Circuit  
Limiter  
Loop Filter  
TIE Corrector  
Feedback Signal from  
Frequency Select MUX  
State Select from  
Input Impairment  
Monitor  
Control  
Circuit  
State Select from  
State Machine  
Figure 4 - DPLL Block Diagram  
6
Advance Information  
MT9044  
In Normal Mode, the DCO provides an output signal  
which is frequency and phase locked to the selected  
input reference signal.  
C1.5o  
C3o  
T1 Divider  
12MHz  
In Holdover Mode, the DCO is free running at a  
frequency equal to the last (less 30ms to 60ms)  
frequency the DCO was generating while in Normal  
Mode.  
Tapped  
Delay  
Line  
C2o  
C4o  
C8o  
C16o  
F0o  
F8o  
E1 Divider  
In Freerun Mode, the DCO is free running with an  
accuracy equal to the accuracy of the OSCi 20MHz  
source.  
Tapped  
Delay  
Line  
16MHz  
From  
DPLL  
F16o  
Output Interface Circuit  
Tapped  
Delay  
Line  
C6o  
The output of the DCO (DPLL) is used by the Output  
Interface Circuit to provide the output signals shown  
in Figure 5. The Output Interface Circuit uses four  
Tapped Delay Lines followed by a T1 Divider Circuit ,  
an E1 Divider Circuit, a DS2 Divider Circuit and an  
analog PLL to generate the required output signals.  
12MHz  
19MHz  
DS2 Divider  
Tapped  
Delay  
Line  
C19o  
ACKo  
Four tapped delay lines are used to generate a  
16.384MHz, 12.352MHz, 12.624MHz and 19.44 MHz  
signals.  
Analog PLL  
ACKi  
Figure 5 - Output Interface Circuit Block  
Diagram  
The E1 Divider Circuit uses the 16.384MHz signal to  
generate four clock outputs and three frame pulse  
The frame pulse outputs (F0o, F8o, F16o, TSP, RSP)  
are generated directly from the C16 clock.  
outputs.  
The C8o, C4o and C2o clocks are  
generated by simply dividing the C16o clock by two,  
four and eight respectively. These outputs have a  
nominal 50% duty cycle.  
The T1 and E1 signals are generated from a  
common DPLL signal. Consequently, the clock  
outputs C1.5o, C3o, C2o, C4o, C8o, C16o, F0o, F16o  
and C6o are locked to one another for all operating  
states, and are also locked to the selected input  
reference in Normal Mode. See Figures 20 and 21.  
The T1 Divider Circuit uses the 12.384MHz signal to  
generate two clock outputs. C1.5o and C3o are  
generated by dividing the internal C12 clock by four  
and eight respectively.  
nominal 50% duty cycle.  
These outputs have a  
All frame pulse and clock outputs have limited driving  
capability, and should be buffered when driving high  
capacitance (e.g. 30pF) loads.  
The DS2 Divider Circuit uses the 12.624 MHz signal  
to generate the clock output C6o. This output has a  
nominal 50% duty cycle.  
Analog Phase Lock Loop (APLL)  
The analog PLL is intended to be used to achieve a  
50% duty cycle output clock. Connecting C19o to  
ACKi will generate a phase locked 19.44 MHz ACKo  
output with a nominal 50% duty cycle. The analog  
PLL has an intrinsic jitter of less than 0.01 U.I. In  
order to achieve this low jitter level a separate pin is  
provided to power (AVdd) the analog PLL.  
7
MT9044  
Advance Information  
Input Impairment Monitor  
Guard Time Circuit  
This circuit monitors the input signal to the DPLL and  
The GTi pin is used by the Automatic/Manual Control  
State Machine in the MT9044 under either Manual or  
Automatic control. The logic level at the GTi pin  
performs two functions, it enables and disables the  
TIE Corrector Circuit (Manual and Automatic), and it  
selects which mode change takes place (Automatic  
only). See the Applications - Guard Time section.  
automatically  
enables  
the  
Holdover  
Mode  
(Auto-Holdover) when the frequency of the incoming  
signal is outside the auto-holdover capture range  
(See AC Electrical Characteristics - Performance).  
This includes a complete loss of incoming signal, or  
a large frequency shift in the incoming signal. When  
the incoming signal returns to normal, the DPLL is  
returned to Normal Mode with the output signal  
locked to the input signal. The holdover output  
signal is based on the incoming signal 30ms  
minimum to 60ms prior to entering the Holdover  
Mode. The amount of phase drift while in holdover is  
negligible because the Holdover Mode is very  
accurate (e.g. ±0.05ppm). The the Auto-Holdover  
circuit does not use TIE correction. Consequently,  
the phase delay between the input and output after  
switching back to Normal Mode is preserved (is the  
same as just prior to the switch to Auto-Holdover).  
For both Manual and Automatic control, when  
switching from Primary Holdover to Primary Normal,  
the TIE Corrector Circuit is enabled when GTi=1, and  
disabled when GTi=0.  
Under Automatic control and in Primary Normal  
Mode, two state changes are possible (not counting  
Auto-Holdover). These are state changes to Primary  
Holdover or to Secondary Normal. The logic level at  
the GTi pin determines which state change occurs.  
When GTi=0, the state change is to Primary  
Holdover. When GTi=1, the state change is to  
Secondary Normal.  
Automatic/Manual Control State Machine  
The Automatic/Manual Control State Machine allows  
the MT9044 to be controlled automatically (i.e.  
LOS1, LOS2 and GTi signals) or controlled manually  
(i.e. MS1, MS2, GTi and RSEL signals). With  
manual control a single mode of operation (i.e.  
Normal, Holdover and Freerun) is selected. Under  
automatic control the state of the LOS1, LOS2 and  
GTi signals determines the sequence of modes that  
the MT9044 will follow.  
Master Clock  
The MT9044 can use either a clock or crystal as the  
master timing source. For recommended master  
timing circuits, see the Applications - Master Clock  
section.  
Control and Modes of Operation  
As shown in Figure 1, this state machine controls the  
Reference Select MUX, the TIE Corrector Circuit, the  
DPLL and the Guard Time Circuit. Control is based  
on the logic levels at the control inputs LOS1, LOS2,  
RSEL, MS1, MS2 and GTi of the Guard Time Circuit  
(See Figure 6).  
The MT9044 can operate either in Manual or  
Automatic Control. Each control method has three  
possible modes of operation, Normal, Holdover and  
Freerun.  
As shown in Table 3, Mode/Control Select pins MS2  
and MS1 select the mode and method of control.  
All state machine changes occur synchronously on  
the rising edge of F8o. See the Controls and Modes  
of Operation section for full details on Automatic  
Control and Manual Control.  
Control  
RSEL  
Input Reference  
MANUAL  
0
1
0
1
PRI  
SEC  
To  
To TIE  
Corrector  
Enable  
To DPLL  
State  
Select  
Reference  
Select MUX  
AUTO  
State Machine Control  
Reserved  
RSEL  
LOS1  
LOS2  
To and From  
Guard Time  
Circuit  
Automatic/Manual Control  
State Machine  
Table 2 - Input Reference Selection  
MS1  
MS2  
Figure 6 - Automatic/Manual Control State  
Machine Block Diagram  
8
Advance Information  
MT9044  
Normal Mode  
MS2 MS1  
Control  
Mode  
Normal Mode is typically used when a slave clock  
source, synchronized to the network is required.  
0
0
1
1
0
1
0
1
MANUAL  
MANUAL  
MANUAL  
AUTO  
NORMAL  
HOLDOVER  
In Normal Mode, the MT9044 provides timing (C1.5o,  
C2o, C3o, C4o, C8o, C16o, and C19) and frame  
synchronization (F0o, F8o, F16o, RSP, TSP) signals,  
which are synchronized to one of two reference  
inputs (PRI or SEC). The input reference signal may  
have a nominal frequency of 8kHz, 1.544MHz or  
2.048MHz.  
FREERUN  
State Machine Control  
Table 3 - Operating Modes and States  
Manual Control  
Manual Control should be used when either very  
simple MT9044 control is required, or when complex  
control is required which is not accommodated by  
Automatic Control. For example, very simple control  
could include operation in a system which only  
requires Normal Mode with reference switching  
using only a single input stimulus (RSEL). Very  
simple control would require no external circuitry.  
Complex control could include a system which  
requires state changes between Normal, Holdover  
and Freerun Modes based on numerous input  
stimuli. Complex control would require external  
circuitry, typically a microcontroller.  
From a reset condition, the MT9044 will take up to 25  
seconds for the output signal to be phase locked to  
the selected reference.  
The selection of input references is control  
dependent as shown in State Tables 4 and 5. The  
reference frequencies are selected by the frequency  
control pins FS2 and FS1 as shown in Table 1.  
Holdover Mode  
Holdover Mode is typically used for short durations  
(e.g. 2 seconds) while network synchronization is  
temporarily disrupted.  
Under Manual Control, one of the three modes is  
selected by mode/control select pins MS2 and MS1.  
The active reference input (PRI or SEC) is selected  
by the RSEL pin as shown in Table 2. Refer to Table  
In Holdover Mode, the MT9044 provides timing and  
synchronization signals, which are not locked to an  
external reference signal, but are based on storage  
techniques. The storage value is determined while  
the device is in Normal Mode and locked to an  
external reference signal.  
4
and Figure 7 for details of the state change  
sequences.  
Automatic Control  
When in Normal Mode, and locked to the input  
reference signal, a numerical value corresponding to  
the MT9044 output frequency is stored alternately in  
two memory locations every 30ms. When the device  
is switched into Holdover Mode, the value in memory  
from between 30ms and 60ms is used to set the  
output frequency of the device.  
Automatic Control should be used when simple  
MT9044 control is required, which is more complex  
than the very simple control provide by Manual  
Control with no external circuitry, but not as complex  
as Manual Control with a microcontroller.  
For  
example, simple control could include operation in a  
system which can be accommodated by the  
Automatic Control State Diagram shown in Figure 8.  
The frequency accuracy of Holdover Mode is  
±0.05ppm, which translates to a worst case 35 frame  
(125us) slips in 24 hours. This meets the Bellcore  
GR-1244-CORE Stratum 3 requirement of ±0.37ppm  
(255 frame slips per 24 hours).  
Automatic Control is also selected by mode/control  
pins MS2 and MS1. However, the mode and active  
reference source is selected automatically by the  
internal Automatic State Machine (See Figure 6).  
The mode and reference changes are based on the  
logic levels on the LOS1, LOS2 and GTi control pins.  
Refer to Table 5 and Figure 8 for details of the state  
change sequences.  
Two factors affect the accuracy of Holdover Mode.  
One is drift on the Master Clock while in Holdover  
Mode, drift on the Master Clock directly affects the  
Holdover Mode accuracy. Note that the absolute  
Master Clock (OSCi) accuracy does not affect  
Holdover accuracy, only the change in OSCi  
accuracy while in Holdover. For example, a ±32ppm  
9
MT9044  
Advance Information  
master clock may have a temperature coefficient of  
±0.1ppm per degree C. So a 10 degree change in  
temperature, while the MT9044 is in Holdover Mode  
may result in an additional offset (over the  
±0.05ppm) in frequency accuracy of ±1ppm, which  
is much greater than the ±0.05ppm of the MT9044.  
The other factor affecting accuracy is large jitter on  
the reference input prior (30ms to 60ms) to the  
mode switch. For instance, jitter of 7.5UI at 700Hz  
may reduce the Holdover Mode accuracy from  
0.05ppm to 0.10ppm.  
Freerun Mode  
Freerun Mode is typically used when a master clock  
source is required, or immediately following system  
power-up before network synchronization is  
achieved.  
In Freerun Mode, the MT9044 provides timing and  
synchronization signals which are based on the  
master clock frequency (OSCi) only, and are not  
synchronized to the reference signals (PRI and  
SEC).  
The accuracy of the output clock is equal to the  
accuracy of the master clock (OSCi). So if a ±32ppm  
output clock is required, the master clock must also  
be ±32ppm. See Applications - Crystal and Clock  
Oscillator sections.  
10  
Advance Information  
MT9044  
Description  
State  
Normal  
(PRI)  
Normal  
(SEC)  
Holdover  
(PRI)  
Holdover  
(SEC)  
Input Controls  
Freerun  
S0  
MS2  
MS1  
RSEL  
GTi  
S1  
S2  
S1H  
S2H  
0
0
0
0
0
1
0
0
0
1
1
0
0
0
1
0
1
X
0
1
S1  
S1  
S2  
/
-
-
S1 MTIE  
S1  
S1 MTIE  
S1 MTIE  
S1 MTIE  
S1 MTIE  
X
X
X
X
S2 MTIE  
S1H  
S2H  
S0  
-
/
S2 MTIE  
S2 MTIE  
-
/
/
-
/
S2H  
S0  
-
S0  
S0  
Legend:  
-
No Change  
Not Valid  
/
MTIE  
State change occurs with TIE Corrector Circuit  
Refer to Manual Control State Diagram for state changes to and from Auto-Holdover State  
Table 4 - Manual Control State Table  
S0  
Freerun  
(10X)  
S1  
S1A  
Auto-Holdover  
Primary  
S2A  
Auto-Holdover  
Secondary  
(001)  
S2  
Normal  
Secondary  
(001)  
{A}  
{A}  
Normal  
Primary  
(000)  
(000)  
(GTi=0)  
(GTi=1)  
S1H  
Holdover  
Primary  
(010)  
S2H  
Holdover  
Secondary  
(011)  
NOTES:  
(XXX)  
{A}  
MS2 MS1 RSEL  
Invalid Reference Signal  
Phase Re-Alignment  
Phase Continuity Maintained (without TIE Corrector Circuit)  
Phase Continuity Maintained (with TIE Corrector Circuit)  
Movement to Normal State from any  
state requires a valid input signal  
Figure 7 - Manual Control State Diagram  
11  
MT9044  
Advance Information  
Description  
Input Controls  
State  
Normal  
(PRI)  
Normal  
(SEC)  
Holdover  
(PRI)  
Holdover  
(SEC)  
Freerun  
S0  
LOS2  
LOS1  
GTi  
RST  
S1  
S2  
S1H  
S2H  
1
X
X
0
0
1
1
0
0
1
1
1
X
0
1
0
1
X
0 to 1  
-
S0  
S0  
S0  
S0  
1
1
1
1
1
S1  
S1  
S1  
S2  
-
-
-
S1 MTIE  
S1  
S1 MTIE  
S1 MTIE  
S2 MTIE  
S2 MTIE  
-
S1 MTIE  
S1 MTIE  
S1H  
S2 MTIE  
S1H  
-
-
-
S2 MTIE  
-
S2H  
Legend:  
-
No Change  
MTIE  
State change occurs with TIE Corrector Circuit  
Refer to Automatic Control State Diagram for state changes to and from Auto-Holdover State  
Table 5 - Automatic Control (MS1=MS2=1, RSEL=0) State Table  
(11X)  
(11X) RST=1  
Reset  
S0  
Freerun  
(X0X)  
(01X)  
(X0X)  
(01X)  
(X0X)  
(01X)  
(X0X)  
(01X)  
{A}  
S1  
Normal  
Primary  
S1A  
Auto-Holdover  
Primary  
S2A  
Auto-Holdover  
Secondary  
S2  
{A}  
Normal  
Secondary  
(X0X)  
(011)  
(11X)  
(010 or 11X)  
(X0X)  
(011)  
(01X)  
(X00)  
S1H  
Holdover  
Primary  
S2H  
Holdover  
Secondary  
(X01)  
(010 or 11X)  
(11X)  
NOTES:  
(XXX)  
{A}  
LOS2 LOS1 GTi  
Invalid Reference Signal  
Phase Re-Alignment  
Phase Continuity Maintained (without TIE Corrector Circuit)  
Phase Continuity Maintained (with TIE Corrector Circuit)  
Movement to Normal State from any  
state requires a valid input signal  
Figure 8 - Automatic Control State Diagram  
12  
Advance Information  
MT9044  
same signal, these transfer values apply to all  
outputs.  
MT9044 Measures of Performance  
It should be noted that 1UI at 1.544MHz is 644ns,  
which is not equal to 1UI at 2.048MHz, which is  
The following are some synchronizer performance  
indicators and their corresponding definitions.  
488ns.  
Consequently, a transfer value using  
different input and output frequencies must be  
calculated in common units (e.g. seconds) as shown  
in the following example.  
Intrinsic Jitter  
Intrinsic jitter is the jitter produced by the  
synchronizing circuit and is measured at its output.  
It is measured by applying a reference signal with no  
jitter to the input of the device, and measuring its  
output jitter. Intrinsic jitter may also be measured  
when the device is in a non-synchronizing mode,  
such as free running or holdover, by measuring the  
output jitter of the device. Intrinsic jitter is usually  
measured with various bandlimiting filters depending  
on the applicable standards.  
What is the T1 and E1 output jitter when the T1 input  
jitter is 20UI (T1 UI Units) and the T1 to T1 jitter  
attenuation is 18dB?  
A  
------  
20  
OutputT1 = InputT1×10  
–18  
--------  
20  
OutputT1 = 20×10  
= 2.5UI(T1)  
Jitter Tolerance  
(1UIT1)  
---------------------  
(1UIE1)  
OutputE1 = OutputT1 ×  
Jitter tolerance is a measure of the ability of a PLL to  
operate properly (i.e., remain in lock and or regain  
lock in the presence of large jitter magnitudes at  
various jitter frequencies) when jitter is applied to its  
reference. The applied jitter magnitude and jitter  
frequency depends on the applicable standards.  
(644ns)  
(488ns)  
-------------------  
OutputE1 = OutputT1 ×  
= 3.3UI(T1)  
Using the above method, the jitter attenuation can be  
calculated for all combinations of inputs and outputs  
based on the three jitter transfer functions provided.  
Jitter Transfer  
Note that the resulting jitter transfer functions for all  
combinations of inputs (8kHz, 1.544MHz, 2.048MHz)  
Jitter transfer or jitter attenuation refers to the  
magnitude of jitter at the output of a device for a  
given amount of jitter at the input of the device. Input  
jitter is applied at various amplitudes and  
frequencies, and output jitter is measured with  
various filters depending on the applicable  
standards.  
and  
outputs  
(8kHz,  
1.544MHz,  
2.048MHz,  
4.096MHz, 8.192MHz, 16.384MHz) for a given input  
signal (jitter frequency and jitter amplitude) are the  
same.  
Since intrinsic jitter is always present,  
jitter  
attenuation will appear to be lower for small input  
jitter signals than for large ones. Consequently,  
accurate jitter transfer function measurements are  
usually made with large input jitter signals (e.g. 75%  
of the specified maximum jitter tolerance).  
For the MT9044, two internal elements determine  
the jitter attenuation. This includes the internal  
1.9Hz low pass loop filter and the phase slope  
limiter. The phase slope limiter limits the output  
phase slope to 5ns/125us. Therefore, if the input  
signal exceeds this rate, such as for very large  
amplitude low frequency input jitter, the maximum  
output phase slope will be limited (i.e. attenuated) to  
5ns/125us.  
Frequency Accuracy  
Frequency accuracy is defined as the absolute  
tolerance of an output clock signal when it is not  
locked to an external reference, but is operating in a  
free running mode. For the MT9044, the Freerun  
accuracy is equal to the Master Clock (OSCi)  
accuracy.  
The MT9044 has thirteen outputs with three possible  
input frequencies for a total of 39 possible jitter  
transfer functions. However, the data sheet section  
on AC Electrical Characteristics - Jitter Transfer  
specifies transfer values for only three cases, 8kHz  
to 8kHz, 1.544MHz to 1.544MHz and 2.048MHz to  
2.048MHz. Since all outputs are derived from the  
Holdover Accuracy  
Holdover accuracy is defined as the absolute  
tolerance of an output clock signal, when it is not  
13  
MT9044  
Advance Information  
locked to an external reference signal, but is  
end of a particular observation period. Usually, the  
given timing signal and the ideal timing signal are of  
the same frequency. Phase continuity applies to the  
output of the synchronizer after a signal disturbance  
due to a reference switch or a mode change. The  
observation period is usually the time from the  
disturbance, to just after the synchronizer has settled  
to a steady state.  
operating using storage techniques.  
For the  
MT9044, the storage value is determined while the  
device is in Normal Mode and locked to an external  
reference signal.  
The absolute Master Clock (OSCi) accuracy of the  
MT9044 does not affect Holdover accuracy, but the  
change in OSCi accuracy while in Holdover Mode  
does.  
In the case of the MT9044, the output signal phase  
continuity is maintained to within ±5ns at the  
instance (over one frame) of all reference switches  
and all mode changes. The total phase shift,  
depending on the switch or type of mode change,  
may accumulate up to ±200ns over many frames.  
The rate of change of the ±200ns phase shift is  
limited to a maximum phase slope of approximately  
5ns/125us. This meets the maximum phase slope  
requirement of Bellcore GR-1244-CORE (81ns/  
1.326ms).  
Capture Range  
Also referred to as pull-in range. This is the input  
frequency range over which the synchronizer must  
be able to pull into synchronization. The MT9044  
capture range is equal to ±230ppm minus the  
accuracy of the master clock (OSCi). For example, a  
±32ppm master clock results in a capture range of  
±198ppm.  
Phase Lock Time  
Lock Range  
This is the time it takes the synchronizer to phase  
lock to the input signal. Phase lock occurs when the  
input signal and output signal are not changing in  
phase with respect to each other (not including jitter).  
This is the input frequency range over which the  
synchronizer  
must  
be  
able  
to  
maintain  
synchronization. The lock range is equal to the  
capture range for the MT9044.  
Lock time is very difficult to determine because it is  
affected by many factors which include:  
Phase Slope  
i) initial input to output phase difference  
ii) initial input to output frequency difference  
iii) synchronizer loop filter  
Phase slope is measured in seconds per second and  
is the rate at which a given signal changes phase  
with respect to an ideal signal. The given signal is  
typically the output signal. The ideal signal is of  
constant frequency and is nominally equal to the  
value of the final output signal or final input signal.  
iv) synchronizer limiter  
Although a short lock time is desirable, it is not  
always possible to achieve due to other synchronizer  
requirements. For instance, better jitter transfer  
performance is achieved with a lower frequency loop  
filter which increases lock time. And better (smaller)  
phase slope performance (limiter) results in longer  
lock times. The MT9044 loop filter and limiter were  
optimized to meet the AT&T TR62411 jitter transfer  
Time Interval Error (TIE)  
TIE is the time delay between a given timing signal  
and an ideal timing signal.  
and phase slope requirements.  
phase lock time, which is not  
Consequently,  
standards  
Maximum Time Interval Error (MTIE)  
a
requirement, may be longer than in other  
applications. See AC Electrical Characteristics -  
Performance for maximum phase lock time.  
MTIE is the maximum peak to peak delay between a  
given timing signal and an ideal timing signal within a  
particular observation period.  
MTIE(S)= TIEmax(t) TIEmin(t)  
Phase Continuity  
Phase continuity is the phase difference between a  
given timing signal and an ideal timing signal at the  
14  
Advance Information  
MT9044  
MT9044 and Network Specifications  
Applications  
The MT9044 fully meets all applicable PLL  
requirements (intrinsic jitter/wander, jitter/wander  
tolerance, jitter/wander transfer, frequency accuracy,  
frequency holdover accuracy, capture range, phase  
change slope and MTIE during reference  
rearrangement) for the following specifications.  
This section contains MT9044 application specific  
details for clock and crystal operation, guard time  
usage, reset operation, power supply decoupling,  
Manual Control operation and Automatic Control  
operation.  
Master Clock  
1. Bellcore GR-1244-CORE June 1995 for  
Stratum 3, Stratum 4 Enhanced and Stratum 4  
2. AT&T TR62411 (DS1) December 1990 for  
Stratum 3, Stratum 4 Enhanced and Stratum 4  
3. ANSI T1.101 (DS1) February 1994 for  
Stratum 3, Stratum 4 Enhanced and Stratum 4  
4. ETSI 300 011 (E1) April 1992 for  
Single Access and Multi Access  
The MT9044 can use either a clock or crystal as the  
master timing source.  
In Freerun Mode, the frequency tolerance at the  
clock outputs is identical to the frequency tolerance  
of the source at the OSCi pin. For applications not  
requiring an accurate Freerun Mode, tolerance of the  
master timing source may be ±100ppm.  
For  
5. TBR 4 November 1995  
applications requiring an accurate Freerun Mode,  
such as Bellcore GR-1244-CORE, the tolerance of  
the master timing source must Be no greater than  
±32ppm.  
6. TBR 12 December 1993  
7. TBR 13 January 1996  
8. ITU-T I.431 March 1993  
9. ITU-T G.812 June 1998 for type IV clocks for  
1,544 kbit/s interfaces and 2,048 kbit/s interfaces  
Another consideration in determining the accuracy of  
the master timing source is the desired capture  
range. The sum of the accuracy of the master timing  
source and the capture range of the MT9044 will  
always equal ±230ppm. For example, if the master  
timing source is ±100ppm, then the capture range  
will be ±130ppm.  
Clock Oscillator - when selecting a Clock Oscillator,  
numerous parameters must be considered. This  
includes absolute frequency, frequency change over  
temperature, output rise and fall times, output levels  
and duty cycle. See AC Electrical Characteristics.  
MT9044  
+5V  
OSCi  
+5V  
20MHz OUT  
GND  
0.1uF  
OSCo  
No Connection  
Figure 9 - Clock Oscillator Circuit  
For applications requiring ±32ppm clock accuracy,  
the following clock oscillator module may be used.  
CTS CXO-65-HG-5-C-20.0MHz  
Frequency:  
Tolerance:  
20MHz  
25ppm 0C to 70C  
15  
MT9044  
Advance Information  
Rise & Fall Time:  
Duty Cycle:  
8ns (0.5V 4.5V 50pF)  
45% to 55%  
e.g., CTS R1027-2BB-20.0MHZ  
(±20ppm absolute, ±6ppm 0C to 50C, 32pF, 25)  
The output clock should be connected directly (not  
AC coupled) to the OSCi input of the MT9044, and  
the OSCo output should be left open as shown in  
Figure 9.  
Guard Time Adjustment  
Excessive switching of the timing reference (from  
PRI to SEC) in the MT9044 can be minimized by first  
entering Holdover Mode for  
a
predetermined  
Crystal Oscillator  
-
Alternatively,  
a
Crystal  
maximum time (i.e., guard time). If the degraded  
signal returns to normal before the expiry of the  
guard time (e.g. 2.5 seconds), then the MT9044 is  
returned to its Normal Mode (with no reference  
switch taking place). Otherwise, the reference input  
may be changed from Primary to Secondary.  
Oscillator may be used. A complete oscillator circuit  
made up of a crystal, resistor and capacitors is  
shown in Figure 10.  
MT9044  
OSCi  
MT9044  
GTo  
20MHz  
1MΩ  
R
+
150kΩ  
56pF  
39pF  
3-50pF  
C
10uF  
OSCo  
100Ω  
1uH  
GTi  
1uH inductor: may improve stability and is optional  
R
P
1kΩ  
Figure 10 - Crystal Oscillator Circuit  
Figure 11 - Symmetrical Guard Time Circuit  
The accuracy of a crystal oscillator depends on the  
crystal tolerance as well as the load capacitance  
tolerance. Typically, for a 20MHz crystal specified  
with a 32pF load capacitance, each 1pF change in  
load capacitance contributes approximately 9ppm to  
the frequency deviation. Consequently, capacitor  
tolerances, and stray capacitances have a major  
effect on the accuracy of the oscillator frequency.  
A simple way to control the guard time (using  
Automatic Control) is with an RC circuit as shown in  
Figure 11. Resistor R is for protection only and  
P
limits the current flowing into the GTi pin during  
power down conditions. The guard time can be  
calculated as follows.  
V
DD  
V  
---------------------------------  
guard  
guard  
= RC × ln  
RC × 0.6  
The trimmer capacitor shown in Figure 10 may be  
time  
V
DD  
SIH  
used to compensate for capacitive effects.  
If  
accuracy is not a concern, then the trimmer may be  
removed, the 39pF capacitor may be increased to  
56pF, and a wider tolerance crystal may be  
substituted.  
time  
example  
guard  
150k × 10u × 0.6= 0.9s  
time  
The crystal should be a fundamental mode type - not  
an overtone. The fundamental mode crystal permits  
a simpler oscillator circuit with no additional filter  
components and is less likely to generate spurious  
responses. The crystal specification is as follows.  
VSIH is the logic high going threshold level for the  
GTi Schmitt Trigger input, see DC Electrical  
Characteristics  
In cases where fast toggling might be expected of  
the LOS1 input, then an unsymmetrical Guard Time  
Circuit is recommended. This ensures that reference  
switching doesn’t occur until the full guard time value  
has expired. An unsymmetrical Guard Time Circuit  
is shown in Figure 12.  
Frequency:  
20MHz  
As required  
Fundamental  
Parallel  
32pF  
Tolerance:  
Oscillation Mode:  
Resonance Mode:  
Load Capacitance:  
Maximum Series Resistance:  
Approximate Drive Level:  
35Ω  
1mW  
16  
Advance Information  
MT9044  
For instance, 10 Normal to Holdover to Normal mode  
change sequences occur, and in each case Holdover  
was entered for 2s. Each mode change sequence  
could account for a phase change as large as 350ns.  
Thus, the accumulated phase change could be as  
large as 3.5us, and, the overall MTIE could be as  
large as 3.5us.  
MT9044  
GTo  
+
R
C
150kΩ  
R
D
1kΩ  
C
10uF  
Phase  
Phase  
Phase  
= 0.05ppm × 2s = 100ns  
= 50ns + 200ns= 250ns  
hold  
state  
GTi  
R
P
= 10 × (250ns + 100ns) = 3.5us  
1kΩ  
10  
Figure 12 - Unsymmetrical Guard Time  
Circuit  
0.05ppm is the accuracy of Holdover Mode  
50ns is the maximum phase continuity of the  
MT9044 from Normal Mode to Holdover Mode  
Figure 13 shows a typical timing example of an  
unsymmetrical Guard Time Circuit with the MT9044  
in Automatic Control.  
200ns is the maximum phase continuity of the  
MT9044 from Holdover Mode to Normal Mode (with  
or without TIE Corrector Circuit)  
TIE Correction (using GTi)  
When 10 Normal to Holdover to Normal mode  
change sequences occur without MTIE enabled, and  
in each case holdover was entered for 2s, each  
mode change sequence could still account for a  
phase change as large as 350ns. However, there  
would be no accumulated phase change, since the  
input to output phase is re-aligned after every  
Holdover to Normal state change. The overall MTIE  
would only be 350ns.  
When Primary Holdover Mode is entered for short  
time periods, TIE correction should not be enabled.  
This will prevent unwanted accumulated phase  
change between the input and output. This is mainly  
applicable to Manual Control, since Automatic  
Control together with the Guard Time Circuit  
inherently operate in this manner.  
SEC  
SIGNAL  
STATUS  
GOOD  
LOS2  
PRI  
SIGNAL  
STATUS  
GOOD  
GOOD  
BAD  
GOOD  
BAD  
T
T
D
D
LOS1  
GTo  
GTi  
V
SIH  
MT9044  
STATE  
PRI  
NORMAL  
PRI  
HOLDOVER  
PRI  
NORMAL  
PRI  
HOLDOVER  
SEC  
NORMAL  
PRI  
NORMAL  
NOTES:  
1. T represents the time delay from when the reference goes  
D
bad to when the MT9044 is provided with a LOS indication.  
Figure 13 - Automatic Control, Unsymmetrical Guard Time Circuit Timing Example  
17  
MT9044  
Advance Information  
Reset Circuit  
Dual T1 Reference Sources with MT9044 in  
Automatic Control  
A simple power up reset circuit with about a 50us  
reset low time is shown in Figure 14. Resistor R is  
For systems requiring simple state machine control,  
the application circuit shown in Figure 15 using  
Automatic Control may be used.  
P
for protection only and limits current into the RST pin  
during power down conditions. The reset low time is  
not critical but should be greater than 300ns.  
In this circuit, the MT9044 is operating Automatically,  
using a Guard Time Circuit, and the LOS1 and LOS2  
inputs to determine all mode changes. Since the  
Guard Time Circuit is set to about 1s, all line  
interruptions (LOS1=1) less than 1s will cause the  
MT9044 to go from Primary Normal Mode to  
Holdover Mode and not switch references. For line  
interruptions greater than 1s, the MT9044 will switch  
MT9044  
+5V  
R
10kΩ  
Modes from Holdover to Secondary  
Normal,  
RST  
provided that the secondary signal is valid (LOS2=0).  
After receiving a good primary signal (LOS1=0), the  
MT9044 will switch back to Primary Normal Mode  
For complete Automatic Control state machine  
details, refer to Table 5 for the State Table, and  
Figure 8 for the State Diagram.  
R
P
1kΩ  
C
10nF  
Figure 14 - Power-Up Reset Circuit  
MT9074  
To Line 1  
DSTo  
TTIP  
DSTi  
To  
TX Line  
XFMR  
TRING  
F0i  
C4i  
RTIP  
To  
RX Line  
XFMR  
RRING  
MT9044  
F0o  
PRI  
E1.5o  
LOS  
C4o  
SEC  
LOS1  
LOS2  
+ 5V  
+ 5V  
FS1  
MS1  
FS2  
150kΩ  
1kΩ  
MS2  
RSEL  
MT9074  
To Line 2  
GTo  
GTi  
DSTo  
DSTi  
TTIP  
TRST  
RST  
TRING  
To  
TX Line  
XFMR  
1kΩ  
1kΩ  
OSCi  
+
F0i  
C4i  
RTIP  
+ 5V  
10kΩ  
10uF  
RRING  
To  
RX Line  
XFMR  
10nF  
E1.5o  
LOS  
CLOCK  
Out  
20MHz ±32ppm  
MT8985  
STo0  
STi0  
STo1  
STi1  
F0i  
C4i  
Figure 15 - Dual T1 Reference Sources with MT9044 in 1.544MHz Automatic Control  
18  
Advance Information  
MT9044  
To Line 1  
MT9075  
DSTo  
DSTi  
TTIP  
To  
TX Line  
XFMR  
TRING  
F0i  
C4i  
RTIP  
To  
RX Line  
XFMR  
RRING  
MT9044  
RxFP  
LOS  
F0o  
PRI  
C4o  
SEC  
C1.5o  
LOS1  
LOS2  
+ 5V  
FS1  
FS2  
MS1  
MS2  
RSEL  
MT9075  
To Line 2  
DSTo  
DSTi  
TTIP  
GTi  
TRST  
RST  
To  
TX Line  
XFMR  
CLOCK  
Out  
20MHz ±32ppm  
TRING  
OSCi  
F0i  
C4i  
RTIP  
RRING  
To  
RX Line  
XFMR  
RxFP  
LOS  
External Stimulus  
CONTROLLER  
MT8985  
STo0  
STi0  
STo1  
STi1  
F0i  
C4i  
Figure 16 - Dual E1 Reference Sources with MT9044 in 8kHz Manual Control  
Dual E1 Reference Sources with MT9044 in  
Manual Control  
circuit reset pin (TCLR), and a complete device reset  
is done with the RST pin.  
The controller uses two stimulus inputs (LOS)  
directly from the MT9075 E1 interfaces, as well as an  
external stimulus input. The external input may  
come from a device that monitors the status registers  
of the E1 interfaces, and outputs a logic one in the  
event of an unacceptable status condition.  
For systems requiring complex state machine  
control, the application circuit shown in Figure 16  
using Manual Control may be used.  
In this circuit, the MT9044 is operating Manually  
and is using a controller for all mode changes. The  
controller sets the MT9044 modes (Normal, Holdover  
or Freerun) by controlling the MT9044 mode/control  
select pins (MS2 and MS1). The input (Primary or  
Secondary) is selected with the reference select pin  
(RSEL). TIE correction from Primary Holdover Mode  
to Primary Normal Mode is enabled and disabled  
with the guard time input pin (GTi). The input to  
output phase alignment is re-aligned with the TIE  
For complete Manual Control state machine details,  
refer to Table 4 for the State Table, and Figure 7 for  
the State Diagram.  
19  
MT9044  
Advance Information  
To E1 Line  
MT9075  
DSTo  
TTIP  
DSTi  
To  
TX Line  
XFMR  
TRING  
F0i  
C4i  
RTIP  
To  
RX Line  
XFMR  
RRING  
MT9044  
RxFP  
LOS  
F0o  
C4o  
PRI  
C1.5o  
LOS1  
LOS2  
+ 5V  
FS1  
FS2  
MS1  
MS2  
RSEL  
CLOCK  
Out  
20MHz ±32ppm  
MT90840  
To OC3 Line  
STo0-7  
STi0-7  
PDo0-7  
PPFTo  
OSCi  
To  
TX Line  
XFMR  
TCLR  
RST  
C19o  
ACKi  
ACKo  
1kΩ  
F0i  
C4b  
PDi0-7  
GTi  
To  
RX Line  
XFMR  
PCKR  
PPFRi  
+ 5V  
PCKT  
10kΩ  
10nF  
MT90820  
STo0  
STi0  
STo1-8  
STi1-8  
F0i  
C4i  
Figure 17 - Single Source - E1 to STS-3 with 8kHz Reference  
Single Reference Source E1 to STS-3 with 8 kHz  
Reference  
The device may operate in freerun mode or with a  
single reference source. The 8 kHz output from the  
MT9075 is sourced from the clock extracted from the  
E1 trunk. It becomes the reference for the PLL which  
then generates ST-BUS signals F0o, C4o and C2o to  
form the system backplane clock. The MT90840  
connects to the system backplane, as well as to an  
OC3 link via an STS-3 Framer and optical link. The  
19.44 Mhz clock required by the MT90840 is  
generated by the MT9044. In the event that the E1  
link is broken, the LOS output of the MT9075 goes  
high placing the MT9044 in freerun mode.  
20  
Advance Information  
MT9044  
Absolute Maximum Ratings* - Voltages are with respect to ground (V ) unless otherwise stated.  
SS  
Parameter  
Symbol  
Min  
Max  
Units  
1
2
3
4
5
6
Supply voltage  
VDD  
-0.3  
-0.3  
7.0  
VDD+0.3  
20  
V
V
Voltage on any pin  
Current on any pin  
Storage temperature  
V
PIN  
PIN  
I
mA  
°C  
TST  
-55  
125  
PLCC package power dissipation  
P
900  
mW  
mW  
PD  
MQFP package power dissipation  
P
900  
PD  
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.  
Recommended Operating Conditions* - * Voltages are with respect to ground (VSS) unless otherwise stated.  
Characteristics  
Sym  
Min  
Max  
Units  
1
2
Supply voltage  
Operating temperature  
VDD  
TA  
4.5  
-40  
5.5  
85  
V
C
DC Electrical Characteristics* - * Voltages are with respect to ground (V ) unless otherwise stated.  
SS  
Characteristics  
Supply current with: OSCi = 0V  
OSCi = Clock  
Sym  
Min  
Max  
Units  
Conditions/Notes  
1
2
3
4
5
6
7
8
9
IDDS  
IDD  
10  
90  
mA  
mA  
V
Outputs unloaded  
Outputs unloaded  
TTL high-level input voltage  
TTL low-level input voltage  
CMOS high-level input voltage  
CMOS low-level input voltage  
Schmitt high-level input voltage  
Schmitt low-level input voltage  
Schmitt hysteresis voltage  
VIH  
2.0  
VIL  
0.8  
V
VCIH  
VCIL  
VSIH  
VSIL  
VHYS  
IIL  
0.7V  
V
OSCi  
DD  
0.3V  
V
OSCi  
DD  
2.3  
V
GTi, RST  
GTi, RST  
GTi, RST  
0.8  
V
0.4  
-10  
V
10 Input leakage current  
11 High-level output voltage  
12 Low-level output voltage  
+10  
uA  
V
V =V or 0V  
I DD  
VOH  
0.8V  
IOH=4mA  
IOL=4mA  
DD  
VOL  
0.2V  
V
DD  
* Supply voltage and operating temperature are as per Recommended Operating Conditions.  
21  
MT9044  
Advance Information  
AC Electrical Characteristics - Performance  
Characteristics  
Sym  
Min  
Max  
Units Conditions/Notes†  
1
2
3
4
5
6
7
8
9
Freerun Mode accuracy with OSCi at:  
Holdover Mode accuracy with OSCi at:  
Capture range with OSCi at:  
±±0ppm  
±32ppm  
±100ppm  
±0ppm  
-0  
+0  
ppm  
ppm  
ppm  
ppm  
ppm  
ppm  
ppm  
ppm  
ppm  
s
5-8  
-32  
+32  
5-8  
-100  
+100  
5-8  
-0.05 +0.05  
-0.05 +0.05  
-0.05 +0.05  
1,2,4,6-8,40  
1,2,4,6-8,40  
1,2,4,6-8,40  
1-3,6-8  
±32ppm  
±100ppm  
±0ppm  
-230  
-198  
-130  
+230  
+198  
+130  
30  
±32ppm  
±100ppm  
1-3,6-8  
1-3,6-8  
10 Phase lock time  
1-3,6-14  
1-3,6-14  
1-2,4-14  
1-,4,6-14  
1-3,6-14  
1-14,27  
1-14,27  
1-3,6,9-11  
1-3,7,9-11  
1-3,8-11  
11 Output phase continuity with:  
reference switch  
200  
200  
200  
50  
ns  
12  
13  
14  
mode switch to Normal  
mode switch to Freerun  
mode switch to Holdover  
ns  
ns  
ns  
15 MTIE (maximum time interval error)  
600  
45  
ns  
16 Output phase slope  
us/s  
ppm  
ppm  
ppm  
17 Reference input for Auto-Holdover with:  
8kHz  
1.544MHz  
2.048MHz  
-18k  
-36k  
-36k  
+18k  
+36k  
+36k  
18  
19  
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels* - Voltages are  
with respect to ground (V ) unless otherwise stated.  
SS  
Characteristics  
Sym  
Schmitt  
TTL  
CMOS  
Units  
1
2
3
Threshold Voltage  
V
1.5  
2.3  
0.8  
1.5  
2.0  
0.8  
0.5V  
0.7V  
0.3V  
V
V
V
T
DD  
DD  
DD  
Rise and Fall Threshold Voltage High  
Rise and Fall Threshold Voltage Low  
V
HM  
V
LM  
* Supply voltage and operating temperature are as per Recommended Operating Conditions.  
* Timing for input and output signals is based on the worst case result of the combination of TTL and CMOS thresholds.  
* See Figure 18.  
Timing Reference Points  
V
HM  
T
LM  
V
ALL SIGNALS  
V
t
IRF, tORF  
tIRF, tORF  
Figure 18 - Timing Parameter Measurement Voltage Levels  
22  
Advance Information  
MT9044  
AC Electrical Characteristics - Input/Output Timing  
Characteristics  
Sym  
Min  
Max  
Units  
1
Reference input pulse width high or low  
Reference input rise or fall time  
8kHz reference input to F8o delay  
1.544MHz reference input to F8o delay  
2.048MHz reference input to F8o delay  
F8o to F0o delay  
t
t
100  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
RW  
2
10  
6
IRF  
3
t
-21  
337  
222  
110  
11  
R8D  
4
t
363  
238  
134  
35  
R15D  
5
t
R2D  
6
t
F0D  
7
F16o setup to C16o falling  
F16o hold from C16o rising  
F8o to C1.5o delay  
t
F16S  
F16H  
C15D  
8
t
0
20  
9
t
-51  
-3  
-37  
11  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
F8o to C6o delay  
t
t
t
t
t
C6D  
C3D  
C2D  
C4D  
C8D  
F8o to C3o delay  
-51  
-13  
-13  
-13  
-13  
-10  
-10  
0
-37  
2
F8o to C2o delay  
F8o to C4o delay  
2
F8o to C8o delay  
2
F8o to C16o delay  
t
2
C16D  
TSPD  
RSPD  
F8o to TSP delay  
t
10  
F8o to RSP delay  
t
10  
F8o to C19o delay  
t
52  
C19D  
C1.5o pulse width high or low  
C3o pulse width high or low  
C6o pulse width high or low  
C2o pulse width high or low  
C4o pulse width high or low  
C8o pulse width high or low  
C16o pulse width high or low  
TSP pulse width high  
t
309  
149  
72  
339  
175  
86  
C15W  
t
t
t
t
t
C3W  
C6W  
C2W  
C4W  
C8W  
230  
111  
52  
258  
133  
70  
t
24  
35  
C16WL  
t
478  
474  
16  
494  
491  
36  
TSPW  
RSP pulse width high  
t
RSPW  
C19o pulse width high or low  
F0o pulse width low  
t
C19W  
t
230  
111  
52  
258  
133  
70  
F0WL  
F8WH  
F8o pulse width high  
t
F16o pulse width low  
t
F16WL  
Output clock and frame pulse rise or fall time  
Input Controls Setup Time  
Input Controls Hold Time  
t
9
ORF  
t
100  
100  
S
t
H
† See "Notes" following AC Electrical Characteristics tables.  
23  
MT9044  
Advance Information  
t
R8D  
PRI/SEC  
8kHz  
t
t
RW  
V
T
t
t
R15D  
PRI/SEC  
RW  
1.544MHz  
V
T
R2D  
t
PRI/SEC  
RW  
2.048MHz  
V
T
V
T
F8o  
NOTES:  
1. Input to output delay values  
are valid after a TRST or RST  
with no further state changes  
Figure 19 - Input to Output Timing (Normal Mode)  
t
F8WH  
F0D  
V
V
V
V
V
V
T
T
T
T
T
T
F8o  
F0o  
t
t
F0WL  
t
F16WL  
F16o  
t
t
F16S  
F16H  
t
C16WL  
tC16D  
C16o  
C8o  
t
t
C8W  
C8W  
t
t
C8D  
C4D  
C2D  
t
C4W  
C4W  
t
t
C4o  
C2o  
t
C2W  
V
V
T
T
t
t
C6W  
C6W  
t
C6D  
C6o  
t
t
t
C3W  
C3W  
C3D  
V
T
C3o  
t
t
C15D  
C15W  
V
T
C1.5o  
t
C19W  
t
C19D  
t
C19W  
V
T
C19o  
Figure 20 - Output Timing 1  
24  
Advance Information  
MT9044  
F8o  
C2o  
V
T
V
T
tRSPD  
V
T
RSP  
TSP  
t
t
RSPW  
TSPW  
V
T
t
TSPD  
Figure - 21 Output Timing 2  
V
T
F8o  
t
t
S
H
MS1,2  
V
T
LOS1,2  
RSEL, GTi  
Figure 22 - Input Controls Setup and Hold Timing  
AC Electrical Characteristics - Intrinsic Jitter Unfiltered  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
7
8
9
Intrinsic jitter at F8o (8kHz)  
0.0002  
0.0002  
0.0002  
0.030  
0.040  
0.060  
0.120  
0.080  
0.160  
0.320  
0.0002  
0.0002  
0.10  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
1-14,21-24,28  
1-14,21-24,28  
1-14,21-24,28  
1-14,21-24,29  
1-14,21-24,30  
1-14,21-24,31  
1-14,21-24,31  
1-14,21-24,32  
1-14,21-24,33  
1-14,21-24,34  
1-14,21-24,28  
1-14,21-24,28  
1-14,21-24,41  
Intrinsic jitter at F0o (8kHz)  
Intrinsic jitter at F16o (8kHz)  
Intrinsic jitter at C1.5o (1.544MHz)  
Intrinsic jitter at C2o (2.048MHz)  
Intrinsic jitter at C3o (3.088MHz)  
Intrinsic jitter at C6o (6.312MHz)  
Intrinsic jitter at C4o (4.096MHz)  
Intrinsic jitter at C8o (8.192MHz)  
10 Intrinsic jitter at C16o (16.384MHz)  
11 Intrinsic jitter at TSP (8kHz)  
12 Intrinsic jitter at RSP (8kHz)  
13 Intrinsic jitter at C19o (19.44MHz)  
† See "Notes" following AC Electrical Characteristics tables.  
25  
MT9044  
Advance Information  
AC Electrical Characteristics - C1.5o (1.544MHz) Intrinsic Jitter Filtered  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
Intrinsic jitter (4Hz to 100kHz filter)  
Intrinsic jitter (10Hz to 40kHz filter)  
Intrinsic jitter (8kHz to 40kHz filter)  
Intrinsic jitter (10Hz to 8kHz filter)  
0.015  
0.010  
0.010  
0.005  
UIpp  
UIpp  
UIpp  
UIpp  
1-14,21-24,29  
1-14,21-24,29  
1-14,21-24,29  
1-14,21-24,29  
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - C2o (2.048MHz) Intrinsic Jitter Filtered  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
Intrinsic jitter (4Hz to 100kHz filter)  
Intrinsic jitter (10Hz to 40kHz filter)  
Intrinsic jitter (8kHz to 40kHz filter)  
Intrinsic jitter (10Hz to 8kHz filter)  
0.015  
0.010  
0.010  
0.005  
UIpp  
UIpp  
UIpp  
UIpp  
1-14,21-24,30  
1-14,21-24,30  
1-14,21-24,30  
1-14,21-24,30  
† See "Notes" following AC Electrical Characteristics tables  
AC Electrical Characteristics - 8kHz Input to 8kHz Output Jitter Transfer  
Characteristics  
Sym Min Max Units  
Conditions/Notes†  
1
2
3
4
5
6
Jitter attenuation for 1Hz@0.01UIpp input  
Jitter attenuation for 1Hz@0.54UIpp input  
Jitter attenuation for 10Hz@0.10UIpp input  
Jitter attenuation for 60Hz@0.10UIpp input  
Jitter attenuation for 300Hz@0.10UIpp input  
Jitter attenuation for 3600Hz@0.005UIpp input  
0
6
dB  
dB  
dB  
dB  
dB  
dB  
1-3,6,9-14,21-22,24,28,35  
1-3,6,9-14,21-22,24,28,35  
1-3,6,9-14,21-22,24,28,35  
1-3,6,9-14,21-22,24,28,35  
1-3,6,9-14,21-22,24,28,35  
1-3,6,9-14,21-22,24,28,35  
6
16  
22  
38  
12  
28  
42  
45  
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - 1.544MHz Input to 1.544MHz Output Jitter Transfer  
Characteristics  
Sym Min Max Units  
Conditions/Notes†  
1
2
3
4
5
6
7
Jitter attenuation for 1Hz@20UIpp input  
Jitter attenuation for 1Hz@104UIpp input  
Jitter attenuation for 10Hz@20UIpp input  
Jitter attenuation for 60Hz@20UIpp input  
Jitter attenuation for 300Hz@20UIpp input  
Jitter attenuation for 10kHz@0.3UIpp input  
Jitter attenuation for 100kHz@0.3UIpp input  
0
6
dB  
dB  
dB  
dB  
dB  
dB  
dB  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
1-3,7,9-14,21-22,24,29,35  
6
16  
22  
38  
12  
28  
42  
45  
45  
† See "Notes" following AC Electrical Characteristics tables.  
26  
Advance Information  
MT9044  
AC Electrical Characteristics - 2.048MHz Input to 2.048 MHz Output Jitter Transfer  
Characteristics  
Sym Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
7
8
9
Jitter at output for 1Hz@3.00UIpp input  
with 40Hz to 100kHz filter  
2.9  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
UIpp 1-3,8,9-14,21-22,24,30,35  
UIpp 1-3,8,9-14,21-22,24,30,36  
0.09  
1.3  
Jitter at output for 3Hz@2.33UIpp input  
with 40Hz to 100kHz filter  
0.10  
0.80  
0.10  
0.40  
0.10  
0.06  
0.05  
0.04  
0.03  
0.04  
0.02  
Jitter at output for 5Hz@2.07UIpp input  
with 40Hz to 100kHz filter  
Jitter at output for 10Hz@1.76UIpp input  
with 40Hz to 100kHz filter  
Jitter at output for 100Hz@1.50UIpp input  
10 with 40Hz to 100kHz filter  
11 Jitter at output for 2400Hz@1.50UIpp input  
12 with 40Hz to 100kHz filter  
13 Jitter at output for 100kHz@0.20UIpp input  
14 with 40Hz to 100kHz filter  
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - 8kHz Input Jitter Tolerance  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
7
8
Jitter tolerance for 1Hz input  
Jitter tolerance for 5Hz input  
Jitter tolerance for 20Hz input  
Jitter tolerance for 300Hz input  
Jitter tolerance for 400Hz input  
Jitter tolerance for 700Hz input  
Jitter tolerance for 2400Hz input  
Jitter tolerance for 3600Hz input  
0.80  
0.70  
0.60  
0.20  
0.15  
0.08  
0.02  
0.01  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
1-3,6,9-14,21-22,24-26,28  
† See "Notes" following AC Electrical Characteristics tables.  
27  
MT9044  
Advance Information  
AC Electrical Characteristics - 1.544MHz Input Jitter Tolerance  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
7
8
9
Jitter tolerance for 1Hz input  
Jitter tolerance for 5Hz input  
Jitter tolerance for 20Hz input  
Jitter tolerance for 300Hz input  
Jitter tolerance for 400Hz input  
Jitter tolerance for 700Hz input  
Jitter tolerance for 2400Hz input  
Jitter tolerance for 10kHz input  
Jitter tolerance for 100kHz input  
150  
140  
130  
35  
25  
15  
4
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1-3,7,9-14,21-22,24-26,29  
1
0.5  
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - 2.048MHz Input Jitter Tolerance  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
7
8
9
Jitter tolerance for 1Hz input  
Jitter tolerance for 5Hz input  
Jitter tolerance for 20Hz input  
Jitter tolerance for 300Hz input  
Jitter tolerance for 400Hz input  
Jitter tolerance for 700Hz input  
Jitter tolerance for 2400Hz input  
Jitter tolerance for 10kHz input  
Jitter tolerance for 100kHz input  
150  
140  
130  
50  
40  
20  
5
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
UIpp  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1-3,8,9-14,21-22,24-26,30  
1
1
† See "Notes" following AC Electrical Characteristics tables.  
AC Electrical Characteristics - OSCi 20MHz Master Clock Input  
Characteristics  
Sym  
Min  
Max  
Units  
Conditions/Notes†  
1
2
3
4
5
6
Frequency accuracy  
-0  
-32  
-100  
40  
+0  
+32  
+100  
60  
ppm  
ppm  
ppm  
%
15,18  
16,19  
17,20  
(20 MHz nominal)  
Duty cycle  
Rise time  
Fall time  
10  
ns  
10  
ns  
† See "Notes" following AC Electrical Characteristics tables.  
28  
Advance Information  
MT9044  
† Notes:  
Voltages are with respect to ground (V ) unless otherwise stated.  
SS  
Supply voltage and operating temperature are as per Recommended Operating Conditions.  
Timing parameters are as per AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels  
1. PRI reference input selected.  
2. SEC reference input selected.  
3. Normal Mode selected.  
4. Holdover Mode selected.  
5. Freerun Mode selected.  
6. 8kHz Frequency Mode selected.  
7. 1.544MHz Frequency Mode selected.  
8. 2.048MHz Frequency Mode selected.  
9. Master clock input OSCi at 20MHz ±0ppm.  
10. Master clock input OSCi at 20MHz ±32ppm.  
11. Master clock input OSCi at 20MHz ±100ppm.  
12. Selected reference input at ±0ppm.  
13. Selected reference input at ±32ppm.  
14. Selected reference input at ±100ppm.  
15. For Freerun Mode of ±0ppm.  
16. For Freerun Mode of ±32ppm.  
17. For Freerun Mode of ±100ppm.  
18. For capture range of ±230ppm.  
19. For capture range of ±198ppm.  
20. For capture range of ±130ppm.  
21. 25pF capacitive load.  
22. OSCi Master Clock jitter is less than 2nspp, or 0.04UIpp where1UIpp=1/20MHz.  
23. Jitter on reference input is less than 7nspp.  
24. Applied jitter is sinusoidal.  
25. Minimum applied input jitter magnitude to regain synchronization.  
26. Loss of synchronization is obtained at slightly higher input jitter amplitudes.  
27. Within 10ms of the state, reference or input change.  
28. 1UIpp = 125us for 8kHz signals.  
29. 1UIpp = 648ns for 1.544MHz signals.  
30. 1UIpp = 488ns for 2.048MHz signals.  
31. 1UIpp = 323ns for 3.088MHz signals.  
32. 1UIpp = 244ns for 4.096MHz signals.  
33. 1UIpp = 122ns for 8.192MHz signals.  
34. 1UIpp = 61ns for 16.384MHz signals.  
35. No filter.  
36. 40Hz to 100kHz bandpass filter.  
37. With respect to reference input signal frequency.  
38. After a RST or TRST.  
39. Master clock duty cycle 40% to 60%.  
40. Prior to Holdover Mode, device was in Normal Mode and phase locked.  
41. 1Ulpp = 51ns for 19.44MHz signals.  
29  
http://www.mitelsemi.com  
World Headquarters - Canada  
Tel: +1 (613) 592 2122  
Fax: +1 (613) 592 6909  
North America  
Tel: +1 (770) 486 0194  
Fax: +1 (770) 631 8213  
Asia/Pacific  
Tel: +65 333 6193  
Fax: +65 333 6192  
Europe, Middle East,  
and Africa (EMEA)  
Tel: +44 (0) 1793 518528  
Fax: +44 (0) 1793 518581  
Information relating to products and services furnished herein by Mitel Corporation or its subsidiaries (collectively “Mitel”) is believed to be reliable. However, Mitel assumes no  
liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of  
patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or  
service conveys any license, either express or implied, under patents or other intellectual property rights owned by Mitel or licensed from third parties by Mitel, whatsoever.  
Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Mitel, or non-Mitel furnished goods or services may infringe patents or  
other intellectual property rights owned by Mitel.  
This publication is issued to provide information only and (unless agreed by Mitel in writing) may not be used, applied or reproduced for any purpose nor form part of any order or  
contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this  
publication are subject to change by Mitel without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or  
service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific  
piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or  
data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in  
any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Mitel’s  
conditions of sale which are available on request.  
M Mitel (design) and ST-BUS are registered trademarks of MITEL Corporation  
Mitel Semiconductor is an ISO 9001 Registered Company  
Copyright 1999 MITEL Corporation  
All Rights Reserved  
Printed in CANADA  
TECHNICAL DOCUMENTATION - NOT FOR RESALE  

相关型号:

MT9044AL1

Telecom Circuit, 1-Func, PQFP44, 10 X 10 MM, 2 MM HEIGHT, LEAD FREE, MO-112AA-1, MQFP-44
MICROSEMI

MT9044AL1

Telecom Circuit, 1-Func, CMOS, PQFP44, 10 X 10 MM, 2 MM HEIGHT, LEAD FREE, MO-112AA-1, MQFP-44
ZARLINK

MT9044AP

T1/E1/OC3 System Synchronizer
MITEL

MT9044AP

Telecom Circuit, 1-Func, CMOS, PQCC44, PLASTIC, MS-018AC, LCC-44
ZARLINK

MT9044AP1

Telecom Circuit, 1-Func, PQCC44, LEAD FREE, PLASTIC, MS-018AC, LCC-44
MICROSEMI

MT9044APR

Telecom IC, CMOS, PQCC44
MICROSEMI

MT9044APR

Telecom Circuit, 1-Func, CMOS, PQCC44, PLASTIC, MS-018AC, LCC-44
ZARLINK

MT9044APR1

Telecom Circuit, 1-Func, CMOS, PQCC44, LEAD FREE, PLASTIC, MS-018AC, LCC-44
ZARLINK

MT9045

T1/E1/OC3 System Synchronizer
ZARLINK

MT9045AN

T1/E1/OC3 System Synchronizer
ZARLINK

MT9045ANR

Telecom Circuit, 1-Func, PDSO48, 0.300 INCH, MO-118AA, SSOP-48
ZARLINK

MT9045ANR1

Telecom Circuit, 1-Func, PDSO48, 0.300 INCH, LEAD FREE, MO-118AA, SSOP-48
MICROSEMI