SY100E451JI [MICREL]

6-BIT REGISTER DIFFERENTIAL DATA CLOCK; 6位寄存器差分数据时钟
SY100E451JI
型号: SY100E451JI
厂家: MICREL SEMICONDUCTOR    MICREL SEMICONDUCTOR
描述:

6-BIT REGISTER DIFFERENTIAL DATA CLOCK
6位寄存器差分数据时钟

时钟
文件: 总4页 (文件大小:63K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
6-BIT REGISTER  
DIFFERENTIAL DATA CLOCK  
SY10E451  
SY100E451  
FEATURES  
DESCRIPTION  
1100MHz min. toggle frequency  
Extended 100E VEE range of –4.2V to –5.5V  
Differential inputs: data and clock  
VBB output for single-ended use  
Asynchronous Master Reset  
The SY10/100E451 offer six D-type flip-flops with single-  
ended outputs and differential data and clock inputs,  
designed for use in new, high-performance ECL systems.  
The registers are triggered by the rising edge of the CLK  
input.  
A logic HIGH on the Master Reset (MR) input resets all  
outputs to a logic LOW. The VBB output is provided for use  
as a reference voltage for single-ended reception of ECL  
signals to that device only. When used for this purpose, it  
is recommended that VBB is decoupled to VCC via a 0.01µF  
capacitor.  
Fully compatible with industry standard 10KH,  
100K ECL levels  
Internal 75Kinput pulldown resistors  
Fully compatible with Motorola MC10E/100E451  
Available in 28-pin PLCC package  
BLOCK DIAGRAM  
PIN NAMES  
Pin  
D0–D5  
Function  
+ Data Input  
D0  
/D0  
Q0  
Q1  
Q2  
Q3  
Q4  
Q5  
D
D
/D0–/D5  
CLK  
– Data Input  
R
R
R
R
R
R
+ Clock Input  
– Clock Input  
Data Outputs  
Master Reset Input  
VBB Output  
D1  
/D1  
/CLK  
Q0–Q5  
MR  
D2  
/D2  
D
D
D
D
VBB  
VCCO  
VCC to Output  
D3  
/D3  
D4  
/D4  
D5  
/D5  
CLK  
/CLK  
MR  
VBB  
Rev.: G  
Amendment: /0  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
1
Issue Date: March 2006  
SY10E451  
SY100E451  
Micrel, Inc.  
PACKAGE/ORDERING INFORMATION  
Ordering Information(1)  
Package Operating  
Package  
Marking  
Lead  
Finish  
Part Number  
SY10E451JI  
SY10E451JITR(2)  
Type  
Range  
J28-1  
J28-1  
J28-1  
Industrial  
Industrial  
Industrial  
SY10E451JI  
SY10E451JI  
SY100E451JI  
Sn-Pb  
Sn-Pb  
Sn-Pb  
25 24  
23 22 21 20 19  
26  
27  
28  
1
18  
17  
16  
15  
14  
13  
12  
CLK  
VBB  
Q5  
Q4  
SY100E451JI  
/CLK  
VEE  
MR  
NC  
VCC  
Q3  
TOP VIEW  
PLCC  
J28-1  
SY100E451JITR(2)  
J28-1  
Industrial  
SY100E451JI  
Sn-Pb  
2
VCCO  
Q2  
SY10E451JC  
SY10E451JCTR(2)  
J28-1  
J28-1  
J28-1  
Commercial  
Commercial  
Commercial  
SY10E451JC  
SY10E451JC  
SY100E451JC  
Sn-Pb  
Sn-Pb  
Sn-Pb  
3
D0  
Q1  
4
SY100E451JC  
5
6
7
8
9
10 11  
SY100E451JCTR(2)  
SY10E451JY(3)  
J28-1  
J28-1  
Commercial  
Industiral  
SY100E451JC  
Sn-Pb  
SY10E451JY with  
Matte-Sn  
Pb-Free bar-line indicator  
SY10E451JYTR(2, 3)  
SY100E451JY(3)  
J28-1  
J28-1  
Industrial  
Industrial  
SY10E451JY with  
Pb-Free bar-line indicator  
Matte-Sn  
Matte-Sn  
28-Pin PLCC (J28-1)  
SY100E451JY with  
Pb-Free bar-line indicator  
SY100E451JYTR(2, 3)  
J28-1  
Industrial  
SY100E451JY with  
Matte-Sn  
Pb-Free bar-line indicator  
Notes:  
1. Contact factory for die availability. Dice are guaranteed at T = 25°C, DC Electricals only.  
A
2. Tape and Reel.  
3. Pb-Free package is recommended for new designs.  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
2
SY10E451  
SY100E451  
Micrel, Inc.  
DC ELECTRICAL CHARACTERISTICS  
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND  
TA = –40°C  
TA = 0°C  
TA = 25°C  
TA = +85°C  
Symbol  
Parameter  
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit  
VBB  
Output Reference 10E  
1.38  
1.38  
1.27 1.35  
1.26 1.38  
1.25 1.31  
1.26 1.38  
1.19  
1.26  
V
Voltage  
100E  
IIH  
Input HIGH Current  
150  
150  
150  
µA  
IEE  
Power Supply  
Current  
10E  
100E  
84  
84  
101  
101  
84  
84  
101  
101  
84  
97  
101  
116  
mA  
VCMR  
Common Mode Range(1)  
2.0  
0.4 2.0  
0.4 2.0  
0.4  
V
Note:  
1. VCMR is referenced to the most psitive side of the differential input signal. Normal operation is obtained when the HIGHinput is within the VCMR range  
and the input swing is greater than VPP (min) and < 1V.  
AC ELECTRICAL CHARACTERISTICS  
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND  
TA = –40°C  
TA = 0°C  
TA = 25°C  
TA = +85°C  
Symbol  
fMAX  
Parameter  
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit  
Max. Toggle Frequency  
1100 1400  
1100 1400  
1100 1400  
MHz  
ps  
tPD  
Propagation Delay to  
Output  
CLK (Diff)  
CLK (SE)  
MR  
475  
425  
425  
650  
650  
600  
800  
850  
850  
475  
425  
425  
650  
650  
600  
800  
850  
850  
475  
425  
425  
650  
650  
600  
800  
850  
850  
tS  
tH  
Set-up Time  
Hold Time  
D
D
150 100  
150 100  
150 100  
ps  
ps  
250  
150  
750  
400  
100  
250  
150  
750  
400  
100  
250  
150  
750  
400  
100  
VPP (AC) Minimum Input Swing(1)  
mV  
ps  
tRR  
tPW  
Reset Recovery Time  
Minimum Pulse Width  
600  
600  
600  
ps  
CLK, MR  
tskew  
Within-Device Skew(2)  
100  
450  
100  
450  
100  
450  
ps  
ps  
tr  
tf  
Rise/Fall Time  
20% to 80%  
275  
800  
275  
800  
275  
800  
Notes:  
1. Minimum input voltage for which AC parameters are guaranteed.  
2. Within-device skew is defined as identical transitions on similar paths through a device.  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
3
SY10E451  
SY100E451  
Micrel, Inc.  
28-PIN PLCC (J28-1)  
Rev. 03  
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA  
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com  
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.  
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.  
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can  
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into  
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchasers  
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchasers own risk and Purchaser agrees to fully indemnify  
Micrel for any damages resulting from such use or sale.  
© 2006 Micrel, Incorporated.  
M9999-032206  
hbwhelp@micrel.com or (408) 955-1690  
4

相关型号:

SY100E451JITR

6-BIT REGISTER DIFFERENTIAL DATA CLOCK
MICREL

SY100E451JY

6-BIT REGISTER DIFFERENTIAL DATA CLOCK
MICREL

SY100E451JY

D Flip-Flop, 100E Series, 1-Func, Positive Edge Triggered, 6-Bit, True Output, ECL, PQCC28, LEAD FREE, PLASTIC, LCC-28
MICROCHIP

SY100E451JY-TR

D Flip-Flop, 100E Series, 1-Func, Positive Edge Triggered, 6-Bit, True Output, ECL, PQCC28, LEAD FREE, PLASTIC, LCC-28
MICREL

SY100E451JY-TR

D Flip-Flop, 100E Series, 1-Func, Positive Edge Triggered, 6-Bit, True Output, ECL, PQCC28, LEAD FREE, PLASTIC, LCC-28
MICROCHIP

SY100E451JYTR

6-BIT REGISTER DIFFERENTIAL DATA CLOCK
MICREL

SY100E452JC

5-BIT DIFFERENTIAL REGISTER
MICREL

SY100E452JCTR

5-BIT DIFFERENTIAL REGISTER
MICREL

SY100E452JI

5-BIT DIFFERENTIAL REGISTER
MICREL

SY100E452JI

SY100E452JI
MICROCHIP

SY100E452JITR

5-BIT DIFFERENTIAL REGISTER
MICREL

SY100E457

TRIPLE DIFFERENTIAL 2:1 MULTIPLEXER
MICREL