QP-150B [MEANWELL]

150W Quad Output with PFC Function; 150W四路输出带PFC功能
QP-150B
型号: QP-150B
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

150W Quad Output with PFC Function
150W四路输出带PFC功能

功率因数校正
文件: 总5页 (文件大小:756K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
150W Quad Output with PFC Function  
QP-150 series  
Features :  
Universal AC input / Full range  
Built-in active PFC function, PF>0.95  
Protections: Short circuit / Over load / Over voltage  
Forced air cooling by built-in DC fan  
CH4: Polarity is selectable  
Fixed switching frequency at 100KHz  
3 years warranty  
..  
SPECIFICATION  
MODEL  
QP-150-3A  
QP-150-3B  
QP-150-3C  
OUTPUT NUMBER  
CH1  
5V  
CH2  
3.3V  
10A  
CH3  
12V  
5A  
CH4  
-5V  
CH1  
5V  
CH2  
CH3  
12V  
5A  
CH4  
-12V  
0.6A  
CH1  
5V  
CH2  
CH3  
15V  
4A  
CH4  
-15V  
0.6A  
DC VOLTAGE  
3.3V  
10A  
3.3V  
10A  
RATED CURRENT  
CURRENT RANGE  
RATED POWER (max.)  
10A  
0.6A  
10A  
10A  
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A  
146W  
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A  
150.2W  
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A  
152W  
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p  
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V  
VOLTAGE TOLERANCE Note.3 3.0%  
OUTPUT  
3.0%  
1.0%  
2.0%  
6.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
6.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
+8,-6%  
2.0%  
5.0%  
1.0%  
2.0%  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
1.0%  
2.0%  
6.0%  
800ms, 50ms/230VAC  
800ms, 50ms/115VAC at full load  
HOLD UP TIME (Typ.)  
VOLTAGE RANGE  
24ms/230VAC  
90 ~ 264VAC  
47 ~ 63Hz  
24ms/115VAC at full load  
127 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
PF>0.95/230VAC  
73%  
PF>0.98/115VAC at full load  
75%  
74%  
INPUT  
2.5A/115VAC  
1.2A/230VAC  
COLD START 40A/230V  
<3.5mA / 240VAC  
LEAKAGE CURRENT  
105 ~ 150% rated output power  
OVERLOAD  
Protection type : Hiccup mode, recovers automatically after fault condition is removed  
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V  
Protection type : Shut down o/p voltage, re-power on to recover  
95 (TSW1)  
PROTECTION  
OVER VOLTAGE  
5
OVER TEMPERATURE(OPTION)  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
-10 ~ +60 (Refer to output load derating curve)  
WORKING TEMP.  
20 ~ 90% RH non-condensing  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
-20 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT  
0.03%/ (0~50  
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
UL60950-1, TUV EN60950-1 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH  
SAFETY &  
EMC  
(Note 4)  
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B  
HARMONIC CURRENT  
EMS IMMUNITY  
MTBF  
Compliance to EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A  
141.5K hrs min. MIL-HDBK-217F (25  
199*99*50mm (L*W*H)  
)
DIMENSION  
PACKING  
OTHERS  
NOTE  
0.93Kg; 20pcs/19.6Kg/1.28CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
File Name:QP-150-SPEC 2010-10-18  
150W Quad Output with PFC Function  
QP-150 series  
Features :  
Universal AC input / Full range  
Built-in active PFC function, PF>0.95  
Protections: Short circuit / Overload / Over voltage  
Forced air cooling by built-in DC fan  
CH4: Polarity is selectable  
Fixed switching frequency at 100KHz  
3 years warranty  
..  
SPECIFICATION  
MODEL  
QP-150-3D  
QP-150D  
QP-150F  
OUTPUT NUMBER  
CH1  
5V  
CH2  
3.3V  
10A  
CH3  
24V  
2.5A  
CH4  
-12V  
0.6A  
CH1  
5V  
CH2  
12V  
4A  
CH3  
24V  
2A  
CH4  
-12V  
0.6A  
CH1  
5V  
CH2  
15V  
3A  
CH3  
24V  
2A  
CH4  
-15V  
0.6A  
DC VOLTAGE  
RATED CURRENT  
CURRENT RANGE  
RATED POWER (max.)  
10A  
10A  
10A  
3 ~ 15A 0 ~ 15A 0.3 ~ 3A 0 ~ 1A  
150.2W  
3 ~ 15A 0 ~ 5A  
150.2W  
0.4 ~ 3A 0 ~ 1A  
3 ~ 15A 0 ~ 5A  
152W  
0.4 ~ 3A 0 ~ 1A  
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p  
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V  
VOLTAGE TOLERANCE Note.3 3.0%  
OUTPUT  
3.0%  
1.0%  
2.0%  
6.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
6.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
3.0%  
1.0%  
2.0%  
6.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
HOLD UP TIME (Typ.)  
1.0%  
2.0%  
800ms, 50ms/230VAC  
800ms, 50ms/115VAC at full load  
24ms/230VAC  
90 ~ 264VAC  
47 ~ 63Hz  
24ms/115VAC at full load  
127 ~ 370VDC  
VOLTAGE RANGE  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
PF>0.95/230VAC  
76%  
PF>0.98/115VAC at full load  
78%  
78%  
INPUT  
2.5A/115VAC  
1.2A/230VAC  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
COLD START 40A/230V  
<3.5mA / 240VAC  
LEAKAGE CURRENT  
105 ~ 150% rated output power  
OVERLOAD  
Protection type : Hiccup mode, recovers automatically after fault condition is removed  
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V  
Protection type : Shut down o/p voltage, re-power on to recover  
95 (TSW1)  
CH2:17.25 ~ 20.25V  
PROTECTION  
OVER VOLTAGE  
5
OVER TEMPERATURE(OPTION)  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
-10 ~ +60 (Refer to output load derating curve)  
WORKING TEMP.  
20 ~ 90% RH non-condensing  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
-20 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT  
0.03%/ (0~50  
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
UL60950-1, TUV EN60950-1 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  
SAFETY &  
ISOLATION RESISTANCE  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH  
EMC  
(Note 4)  
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B  
HARMONIC CURRENT  
EMS IMMUNITY  
MTBF  
Compliance to EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A  
141.5K hrs min. MIL-HDBK-217F (25  
199*99*50mm (L*W*H)  
)
OTHERS  
NOTE  
DIMENSION  
PACKING  
0.93Kg; 20pcs/19.6Kg/1.28CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
File Name:QP-150-SPEC 2010-10-18  
150W Quad Output with PFC Function  
QP-150 series  
Mechanical Specification  
Case No. 916B Unit:mm  
199  
65  
20  
25  
35  
133  
117  
48.5  
70  
LED  
10  
+V ADJ.2  
+V ADJ.1  
9
8
7
6
5
4
3
2
1
2-M4  
5-M3 L=6mm  
15  
142  
25  
Air flow  
direction  
Terminal Pin No. Assignment :  
Pin No.  
Assignment  
AC/L  
Pin No.  
5
Assignment  
9 max.  
1
2
3
4
DC OUTPUT V3  
DC OUTPUT V1  
DC OUTPUT COM  
DC OUTPUT V2  
AC/N  
6,7  
8,9  
10  
FG  
DC OUTPUT V4  
6-M4 L=6mm  
FAN  
Block Diagram  
fosc : 100KHz  
V4  
RECTIFIERS  
&
FILTER  
REGULATOR  
EMI FILTER  
&
RECTIFIERS  
RECTIFIERS  
&
FILTER  
POWER  
SWITCHING  
PFC  
CIRCUIT  
I/P  
FG  
V3  
V2  
RECTIFIERS  
&
FILTER  
MA  
&
CONTROL  
PWM & PFC  
CONTROL  
+5V  
COM  
RECTIFIERS  
&
FILTER  
DETECTION CIRCUT  
O.V.P.  
Derating Curve  
Output Derating VS Input Voltage  
100  
90  
100  
80  
80  
70  
60  
40  
60  
50  
40  
20  
-10  
-10  
0
0
10  
20  
30  
40  
50  
60 (HORIZONTAL)  
90  
100  
115  
135  
155  
230 264  
AMBIENT TEMPERATURE (  
)
INPUT VOLTAGE (VAC) 60Hz  
File Name:QP-150-SPEC 2010-10-18  
150W Quad Output with PFC Function  
QP-150B,C series  
Features :  
Universal AC input / Full range  
Built-in active PFC function, PF>0.95  
Protections: Short circuit / Overload / Over voltage  
Forced air cooling by built-in DC fan  
Fixed switching frequency at 100KHz  
3 years warranty  
..  
SPECIFICATION  
MODEL  
QP-150B  
QP-150C  
OUTPUT NUMBER  
CH1  
CH2  
12V  
CH3  
CH4  
-5V  
CH1  
CH2  
15V  
CH3  
CH4  
-5V  
DC VOLTAGE  
5V  
-12V  
2A  
5V  
-15V  
2A  
RATED CURRENT  
CURRENT RANGE  
RATED POWER (max.)  
15A  
4A  
0.6A  
0 ~ 1A  
15A  
3A  
0.6A  
0 ~ 1A  
3 ~ 15A  
150W  
0.4 ~ 5A  
0.3 ~ 2A  
3 ~ 15A  
153W  
0.4 ~ 4A  
0.3 ~ 2A  
RIPPLE & NOISE (max.) Note.2 100mVp-p  
150mVp-p  
150mVp-p  
100mVp-p  
100mVp-p  
CH1:4.75 ~ 5.5V  
3.0%  
150mVp-p  
150mVp-p  
100mVp-p  
OUTPUT  
VOLTAGE ADJ. RANGE  
CH1:4.75 ~ 5.5V  
VOLTAGE TOLERANCE Note.3 3.0%  
6.0%  
2.0%  
6.0%  
+10,-6%  
2.0%  
5.0%  
1.0%  
2.0%  
+6,-10%  
2.0%  
8.0%  
2.0%  
6.0%  
5.0%  
1.0%  
2.0%  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
1.0%  
2.0%  
1.0%  
6.0%  
2.0%  
6.0%  
1000ms, 50ms at full load  
24ms at full load  
HOLD UP TIME (Typ.)  
VOLTAGE RANGE  
90 ~ 264VAC  
47 ~ 63Hz  
127 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
PF>0.95/230VAC  
76%  
PF>0.98/115VAC at full load  
77%  
INPUT  
2.5A/115VAC  
1.2A/230VAC  
COLD START 40A  
LEAKAGE CURRENT  
<3.5mA / 240VAC  
105 ~ 135% rated output power  
OVERLOAD  
Protection type : Hiccup mode, recovers automatically after fault condition is removed  
CH1:5.75 ~ 6.75V  
PROTECTION  
OVER VOLTAGE  
Protection type : Shut down o/p voltage, re-power on to recover  
95  
5
(TSW1)  
OVER TEMPERATURE(OPTION)  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
-10 ~ +60 (Refer to output load derating curve)  
20 ~ 90% RH non-condensing  
WORKING TEMP.  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
VIBRATION  
-20 ~ +85 , 10 ~ 95% RH  
ENVIRONMENT  
0.03%/ (0~50  
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
UL60950-1, TUV EN60950-1 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH  
SAFETY &  
EMC  
(Note 4)  
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B  
HARMONIC CURRENT  
EMS IMMUNITY  
MTBF  
Compliance to EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A  
141.5K hrs min. MIL-HDBK-217F (25  
199*99*50mm (L*W*H)  
)
OTHERS  
NOTE  
DIMENSION  
PACKING  
1.1Kg; 20pcs/22Kg/1.28CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
File Name:QP-150B,C-SPEC 2010-10-18  
150W Quad Output with PFC Function  
QP-150B,C series  
Mechanical Specification  
Case No. 916B Unit:mm  
199  
65  
20  
25  
35  
133  
117  
48.5  
70  
LED  
10  
+V ADJ.1  
9
8
7
6
5
4
3
2
1
2-M4  
5-M3 L=6mm  
15  
142  
25  
Air flow  
direction  
Terminal Pin No. Assignment :  
Pin No.  
Assignment  
AC/L  
Pin No.  
5
Assignment  
9 max.  
1
2
3
4
DC OUTPUT V3  
DC OUTPUT V1  
DC OUTPUT COM  
DC OUTPUT V2  
AC/N  
6,7  
8,9  
10  
FG  
DC OUTPUT V4  
6-M4 L=6mm  
Block Diagram  
fosc : 100KHz  
V4  
RECTIFIERS  
&
FILTER  
REGULATOR  
EMI FILTER  
&
RECTIFIERS  
RECTIFIERS  
&
FILTER  
POWER  
SWITCHING  
PFC  
CIRCUIT  
I/P  
FG  
V3  
V2  
FAN  
RECTIFIERS  
&
FILTER  
MA  
&
CONTROL  
PWM & PFC  
CONTROL  
+5V  
COM  
RECTIFIERS  
&
FILTER  
DETECTION CIRCUT  
O.V.P.  
Derating Curve  
Output Derating VS Input Voltage  
100  
90  
100  
80  
80  
70  
60  
40  
60  
50  
40  
20  
-10  
-10  
0
0
10  
20  
30  
40  
50  
60 (HORIZONTAL)  
90  
100  
115  
135  
155  
230 264  
AMBIENT TEMPERATURE (  
)
INPUT VOLTAGE (VAC) 60Hz  
File Name:QP-150B,C-SPEC 2010-10-18  

相关型号:

QP-150C

150W Quad Output with PFC Function
MEANWELL

QP-150D

150W Quad Output with PFC Function
ASTRODYNE

QP-150D

150W Quad Output with PFC Function
MEANWELL

QP-150F

150W Quad Output with PFC Function
ASTRODYNE

QP-150F

150W Quad Output with PFC Function
MEANWELL

QP-150_10

150W Quad Output with PFC Function
MEANWELL

QP-150_11

150W Quad Output with PFC Function
MEANWELL

QP-200

200W Quad Output with PFC Function
ASTRODYNE

QP-200

200W Quad Output with PFC Function
RSG

QP-200

200W Quad Output with PFC Function
MEANWELL

QP-200-3A

200W Quad Output with PFC Function
ASTRODYNE

QP-200-3A

200W Quad Output with PFC Function
RSG