QP-150B [MEANWELL]
150W Quad Output with PFC Function; 150W四路输出带PFC功能型号: | QP-150B |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 150W Quad Output with PFC Function |
文件: | 总5页 (文件大小:756K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
150W Quad Output with PFC Function
QP-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Over load / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-150-3A
QP-150-3B
QP-150-3C
OUTPUT NUMBER
CH1
5V
CH2
3.3V
10A
CH3
12V
5A
CH4
-5V
CH1
5V
CH2
CH3
12V
5A
CH4
-12V
0.6A
CH1
5V
CH2
CH3
15V
4A
CH4
-15V
0.6A
DC VOLTAGE
3.3V
10A
3.3V
10A
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
10A
0.6A
10A
10A
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
146W
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
150.2W
3 ~ 15A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
152W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0%
OUTPUT
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
+8,-6%
2.0%
5.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
6.0%
800ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
24ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
PF>0.95/230VAC
73%
PF>0.98/115VAC at full load
75%
74%
INPUT
2.5A/115VAC
1.2A/230VAC
COLD START 40A/230V
<3.5mA / 240VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1)
PROTECTION
OVER VOLTAGE
5
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
)
DIMENSION
PACKING
OTHERS
NOTE
0.93Kg; 20pcs/19.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2010-10-18
150W Quad Output with PFC Function
QP-150 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-150-3D
QP-150D
QP-150F
OUTPUT NUMBER
CH1
5V
CH2
3.3V
10A
CH3
24V
2.5A
CH4
-12V
0.6A
CH1
5V
CH2
12V
4A
CH3
24V
2A
CH4
-12V
0.6A
CH1
5V
CH2
15V
3A
CH3
24V
2A
CH4
-15V
0.6A
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
10A
10A
10A
3 ~ 15A 0 ~ 15A 0.3 ~ 3A 0 ~ 1A
150.2W
3 ~ 15A 0 ~ 5A
150.2W
0.4 ~ 3A 0 ~ 1A
3 ~ 15A 0 ~ 5A
152W
0.4 ~ 3A 0 ~ 1A
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p 120mVp-p 150mVp-p 200mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V
VOLTAGE TOLERANCE Note.3 3.0%
OUTPUT
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
6.0%
2.0%
6.0%
5.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
1.0%
2.0%
800ms, 50ms/230VAC
800ms, 50ms/115VAC at full load
24ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
24ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.95/230VAC
76%
PF>0.98/115VAC at full load
78%
78%
INPUT
2.5A/115VAC
1.2A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
COLD START 40A/230V
<3.5mA / 240VAC
LEAKAGE CURRENT
105 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V CH1:5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
95 (TSW1)
CH2:17.25 ~ 20.25V
PROTECTION
OVER VOLTAGE
5
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.93Kg; 20pcs/19.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:QP-150-SPEC 2010-10-18
150W Quad Output with PFC Function
QP-150 series
Mechanical Specification
Case No. 916B Unit:mm
199
65
20
25
35
133
117
48.5
70
LED
10
+V ADJ.2
+V ADJ.1
9
8
7
6
5
4
3
2
1
2-M4
5-M3 L=6mm
15
142
25
Air flow
direction
Terminal Pin No. Assignment :
Pin No.
Assignment
AC/L
Pin No.
5
Assignment
9 max.
1
2
3
4
DC OUTPUT V3
DC OUTPUT V1
DC OUTPUT COM
DC OUTPUT V2
AC/N
6,7
8,9
10
FG
DC OUTPUT V4
6-M4 L=6mm
FAN
Block Diagram
fosc : 100KHz
V4
RECTIFIERS
&
FILTER
REGULATOR
EMI FILTER
&
RECTIFIERS
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
I/P
FG
V3
V2
RECTIFIERS
&
FILTER
MA
&
CONTROL
PWM & PFC
CONTROL
+5V
COM
RECTIFIERS
&
FILTER
DETECTION CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
90
100
80
80
70
60
40
60
50
40
20
-10
-10
0
0
10
20
30
40
50
60 (HORIZONTAL)
90
100
115
135
155
230 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-150-SPEC 2010-10-18
150W Quad Output with PFC Function
QP-150B,C series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-150B
QP-150C
OUTPUT NUMBER
CH1
CH2
12V
CH3
CH4
-5V
CH1
CH2
15V
CH3
CH4
-5V
DC VOLTAGE
5V
-12V
2A
5V
-15V
2A
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
15A
4A
0.6A
0 ~ 1A
15A
3A
0.6A
0 ~ 1A
3 ~ 15A
150W
0.4 ~ 5A
0.3 ~ 2A
3 ~ 15A
153W
0.4 ~ 4A
0.3 ~ 2A
RIPPLE & NOISE (max.) Note.2 100mVp-p
150mVp-p
150mVp-p
100mVp-p
100mVp-p
CH1:4.75 ~ 5.5V
3.0%
150mVp-p
150mVp-p
100mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
6.0%
2.0%
6.0%
+10,-6%
2.0%
5.0%
1.0%
2.0%
+6,-10%
2.0%
8.0%
2.0%
6.0%
5.0%
1.0%
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
1.0%
2.0%
1.0%
6.0%
2.0%
6.0%
1000ms, 50ms at full load
24ms at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
90 ~ 264VAC
47 ~ 63Hz
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
PF>0.95/230VAC
76%
PF>0.98/115VAC at full load
77%
INPUT
2.5A/115VAC
1.2A/230VAC
COLD START 40A
LEAKAGE CURRENT
<3.5mA / 240VAC
105 ~ 135% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V
PROTECTION
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
95
5
(TSW1)
OVER TEMPERATURE(OPTION)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
141.5K hrs min. MIL-HDBK-217F (25
199*99*50mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
1.1Kg; 20pcs/22Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:QP-150B,C-SPEC 2010-10-18
150W Quad Output with PFC Function
QP-150B,C series
Mechanical Specification
Case No. 916B Unit:mm
199
65
20
25
35
133
117
48.5
70
LED
10
+V ADJ.1
9
8
7
6
5
4
3
2
1
2-M4
5-M3 L=6mm
15
142
25
Air flow
direction
Terminal Pin No. Assignment :
Pin No.
Assignment
AC/L
Pin No.
5
Assignment
9 max.
1
2
3
4
DC OUTPUT V3
DC OUTPUT V1
DC OUTPUT COM
DC OUTPUT V2
AC/N
6,7
8,9
10
FG
DC OUTPUT V4
6-M4 L=6mm
Block Diagram
fosc : 100KHz
V4
RECTIFIERS
&
FILTER
REGULATOR
EMI FILTER
&
RECTIFIERS
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
I/P
FG
V3
V2
FAN
RECTIFIERS
&
FILTER
MA
&
CONTROL
PWM & PFC
CONTROL
+5V
COM
RECTIFIERS
&
FILTER
DETECTION CIRCUT
O.V.P.
Derating Curve
Output Derating VS Input Voltage
100
90
100
80
80
70
60
40
60
50
40
20
-10
-10
0
0
10
20
30
40
50
60 (HORIZONTAL)
90
100
115
135
155
230 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:QP-150B,C-SPEC 2010-10-18
相关型号: