NTU-1200-112GFCI
更新时间:2024-09-18 23:18:53
品牌:MEANWELL
描述:1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200-112GFCI 概述
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200-112GFCI 数据手册
通过下载NTU-1200-112GFCI数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
User’s Manual
Video
E13
UL458
IEC62368-1 BS EN/EN62368-1 (for 112/124 type GFCI only)
TPTC004 AS/NZS 62368.1
■
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧℃℃
‧
‧
‧-
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
■
℃
■
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
SPECIFICATION
NTU-1200-112
= US, GFCI, UN
NTU-1200-124
NTU-1200-148
NTU-1200-212
NTU-1200-224
NTU-1200-248
MODEL NO.
= EU, CN, AU, UK, UN
RATED POWER(Continuous) 1200W
OVER RATED POWER(3 Min.) 1380W
PEAK POWER(10 Sec.)
SURGE POWER(30 Cycles)
1800W
2000W
Default setting set at 110VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W
Default setting set at 60±0.1Hz
Default setting set at 230VAC
200 / 220 / 230 / 240Vac selectable by DIP S.W
Default setting set at 50±0.1Hz
AC VOLTAGE
FREQUENCY
AC OUTPUT
50/60Hz selectable by DIP S.W
50/60Hz selectable by DIP S.W
WAVEFORM
Note.1 True sine wave (THD<3%)
±3.0% at rated input voltage
Please see page 5
AC REGULATION
FRONT PANEL LED
DC VOLTAGE
24Vdc
48Vdc
24Vdc
48Vdc
12Vdc
12Vdc
VOLTAGE RANGE (Typ.)
DC CURRENT (Typ.)
10 ~ 16.5Vdc
120A
20 ~ 33Vdc
60A
40 ~ 66Vdc
30A
10 ~ 16.5Vdc
120A
20 ~ 33Vdc
60A
40 ~ 66Vdc
30A
15W
NON-SAVING MODE
25W
NO LOAD
DISSPATION
(Typ.)
Default disable, auto detect AC output load≦10W will be changed to saving mode
DC INPUT
SAVING MODE
<8W
OFF MODE CURRENT DRAW ≦1mA
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE (INTERNAL)
Note.1 89%
Lead Acid or li-ion
90%
91%
90%
92%
93%
40A*4
40A*2
25A*2
40A*4
40A*2
25A*2
11±0.3Vdc
22±0.5Vdc
20±0.5Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
44±1Vdc
40±1Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
11±0.3Vdc
10±0.3Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
22±0.5Vdc
20±0.5Vdc
25±0.5Vdc
31±0.5Vdc
33±0.5Vdc
30±0.5Vdc
44±1Vdc
40±1Vdc
50±1Vdc
62±1Vdc
66±1Vdc
60±1Vdc
ALARM
10±0.3Vdc
12.5±0.3Vdc
15.5±0.3Vdc
16.5±0.3Vdc
15±0.3Vdc
By internal fuse open
LOW
HIGH
SHUTDOWN
RESTART
ALARM
SHUTDOWN
RESTART
BAT. POLARITY
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
15A
OVER LOAD (Typ.)
CIRCUIT BREAKER
GFCI PROCTECTION
10A
UL458 (Only for “GFCI” AC socket, by request)
None
Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Normal work ; Short : Remote off
Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
CONNECTOR
ACCESSORY
REMOTE
CONTROL
FUNCTION
RS-232 COMMUNICATION
RS-232 ~ RJ11 Type connector (Please refer to page 4 for more details)
100/110/115/120Vac±16%, recover±13%
45 ~ 65Hz
200/220/230/240Vac±16%, recover±13%
AC INPUT RANGE
FREQUENCY RANGE
TRASFER TIME(Typ.)
WORKING TEMP.
AC UPS
MODE
10ms inverter
AC by pass
-25 ~ +70℃(Refer to “Derating curve”)
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
ENVIRONMENT
-30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
CB IEC62368-1,Dekra BS EN/EN62368-1,UL458, E13,EAC TP TC 004 approved; Design refer to AS/NZS 62368.1
SAFETY STANDARDS
WITHSTAND VOLTAGE
(Please refer to next page“AC output socket” table for more details)
DC I/P - AC I/P:3.0KVac DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac
Parameter
Standard
Test Level / Note
Class A
Class A
Class A
Class A
FCC for 112,124,148 only(expect for Type-UN)
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)
FCC for 112,124,148 only(expect for Type-UN)
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)
BS EN/EN61000-3-2
Radiated
EMC EMISSION
Conducted
Harmonic Current
Voltage Flicker
Class A
-----
BS EN/EN61000-3-3
SAFETY
&
BS EN/EN55024, BS EN/EN55035
EMC
Parameter
Standard
Test Level / Note
(Note.3)
ESD
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-5
BS EN/EN61000-4-6
BS EN/EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Level 2
Level 2, 1KV
Level 3, 1KV/Line-Line 2KV/Line-Earth
Level 2
Level 1
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
EMC IMMUNITY
>95% dip 0.5 periods, 30% dip 25 periods,
Voltage Dips and
BS EN/EN61000-4-11
>95% interruptions 250 periods
Interruptions
166.3K hrs min. Telcordia TR/SR-332 (Bellcore) ; 58.3K hrs min. MIL-HDBK-217F (25℃)
MTBF
OTHERS
NOTE
DIMENSION
PACKING
333*184*70mm (L*W*H)
3.3Kg; 2pcs/ 7.6Kg/ 1.25CUFT
℃
※:https://www.meanwell.com/serviceDisclaimer.aspx
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
AC Output Socket
MODEL NO.
NTU-1200-112
NTU-1200-124
NTU-1200-148
NTU-1200-212
NTU-1200-224
NTU-1200-248
Socket type
TYPE-US
Standard
TYPE-GFCI
Optional
TYPE-UN
Standard
TYPE-EU
Standard
TYPE-CN
Standard
TYPE-UK
Optional
TYPE-AU
TYPE-UN
Standard
Optional
Country
USA
USA
UNIVERSAL
EUROPE
CHINA
U.K
AUSTRALIA
UNIVERSAL
E13
E13
E13
None
Certificate
(Except for 48V input)
DERATING CURVE
100
85
50
30
-25
0
10
20
30
35
40
60 70(HORIZONTAL)
AMBIENT TEMPERATURE (℃)
100
others
80
12V
50
40
20
10Vdc
20Vdc
40Vdc
11Vdc
16.5Vdc
21Vdc
42Vdc
33Vdc
66Vdc
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
IRC1/2/3 Remote Controller (Accessory sold seperately)
NTU-1200 series
IRC1/IRC2/IRC3 is the monitoring and control unit.
IRC1/IRC2/IRC3 can decode the RS-232 signals sent by the inverter series and display through digital meters.
Note: Part of the control signals will not function properly due to different compliance of each model.
SOLAR CHARGE
Green
:
ON
Green
: ON
Orange : OFF
Orange : OFF
AC
BATTERY
INVERTER
BATTERY
INVERTER
Red
:
Abnormal
Red
:
Abnormal
LOAD
LOAD
100%
CHARGE
100%
Green
Orange
Red
:
:
:
:
ON
OFF
Abnormal
Power Saving
Orange Power
Orange Power
100%
0%
100%
0%
:
:
Flash Saving
Flash Saving
BY PASS
Orange Flash
0%
0%
AC IN
PUSH
ON OFF
PUSH
PUSH
Model No : IRC1
Model No : IRC2
Model No : IRC3
Inverter Remote Controller
/
ON
/
OFF
ON / OFF
Inverter Remote Controller
Inverter Remote Controller
https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1
※ Please refer to for more detail:
Support RS-232 Communication
The internal data of single NTU-1200 can be read through RS-232.
AC OUTPUT
B
Status
a
SW
e
R.C
DC
input
1
2
Load
AC
input
Remote port
AC INPUT
※ Please refer to for more detail: http://www.meanwell.com/manual.html
※ RJ11-RS232 Communication cable should be ordered seperately, Order No.: RJ11-RS232
Remote ON-OFF Control (Built-in)
Remote ON-OFF
Open
AC Output Status
power inverter ON
power inverter OFF
Short
AC Output Voltage、Frequency、Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the
voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC OUTPUT
B
Status
a
SW
e
R.C
DC
input
1
2
1
2
Load
AC
input
Remote port
AC INPUT
Type-US
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1 SW2
SW4
SW3
OFF OFF : 100Vac or 200Vac
OFF ON : 110Vac or 220Vac
ON : 50Hz
ON : Saving mode
ON
ON
OFF : 115Vac or 230Vac
ON : 120Vac or 240Vac
OFF: Non-Saving mode
OFF: 60Hz
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
LED STATUS
Normal work:
Green
Orange
Red
Remote off
Saving mode
Status
Abnormal Status
Inverter OK
(See below table)
Green
Orange
Red
12.5~15.5Vdc
25~31Vdc
11~12.5Vdc
22~25Vdc
44~50Vdc
<11Vdc or >15.5Vdc
<22Vdc or >31Vdc
<44Vdc or >62Vdc
DC Iput
Load
50~62Vdc
Green
Orange
Red
<40% load
40~80% load
>80% load
Green
-----
-----
Utility OK
AC Input
-----
-----
Utility error
Utility disconnected
Abnormal status :
LED Indicator
Abnormal Indication
Status
DC Input
Load
Output overload or AC output short circuit
Status
DC Input
Load
Abnormal DC voltage
Status
DC Input
Load
Over temperature or Fan lock
Inverter fail
Status
DC Input
Load
Light
Light off
Flash
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
MECHANICAL SPECIFICATION
Unit:mm
333
220
200
200
56.5
20
180
20
9.8
8.3
Air flow
direction
20.9
21.1
7
70
AC OUTPUT
AC OUTPUT
B
B
a
a
SW
SW
e
e
Status
Status
R.C
R.C
DC
DC
input
input
1
2
1
2
Load
Load
AC
AC
input
input
Remote port
Remote port
AC INPUT
AC INPUT
Type-US
Type-EU
AC OUTPUT
AC OUTPUT
B
B
a
a
SW
SW
e
e
Status
Status
R.C
R.C
DC
DC
input
input
1
2
1 2
Load
Load
AC
AC
input
input
Remote port
Remote port
AC INPUT
AC INPUT
Type-CN
Type-UN
(AC output side)
R.C Connector : JST B-XH or equivalent
Remote Control
Mating Housing
Terminal
Pin 1,2 Open: Normal work
JST XHP
JST SXH-001T
or equivalent
or equivalent
Pin 1,2 Short: Remote off
Remote port connector (RJ11)
Rx
2
3
Assignment
Remote port
GND
3
5
Tx
4
2
DB9
Remote port
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
Accessory List
※ Communication cable (Optional accessory, Power inverter and Communication cable should ordered seperately)
MW’s Order No.
Item
Quantity
1
RJ11-RS232
※ Pull handle (Optional accessory, Power inverter and Pull handle should ordered seperately)
MW’s Order No.
Item
Quantity
1
1
2
3
Pull handle
Foot pad
Screw
4
2
Carry Handle
1
Pull Handle
M4*2
2
Foot pad
File Name:NTU-1200-SPEC 2021-09-26
1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter
NTU-1200 series
TYPICAL APPLICATION
1 Battery Bank
2 Off-Grid DC/AC Solar Inverter (NTU series)
3 AC Outlet
3
1
(Shore)
1 Utility Input
5
2 AC/DC Battery Charger (PB/NPB/NPP series)
3 Battery Bank
Off-Grid DC/AC
4
5
Power Inverter (NTU series)
AC Outlet
AC/DC Battery Charger
Battery Bank
(PB/NPB/NPP series)
(NTU series)
4
4
Off-Grid DC/AC Inverter
AC Outlet
2
3
4
1
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:NTU-1200-SPEC 2021-09-26
NTU-1200-112GFCI 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
NTU-1200-112UN | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-112US | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-124GFCI | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-124UN | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-124US | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-148GFCI | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-148UN | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-148US | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-212AU | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 | |
NTU-1200-212CN | MEANWELL | 1200W High Reliable True Sine Wave with UPS DC-AC Power Inverter | 获取价格 |
NTU-1200-112GFCI 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6