LPF-90-30 [MEANWELL]
90W Single Output Switching Power Supply; 90W单路输出开关电源型号: | LPF-90-30 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 90W Single Output Switching Power Supply |
文件: | 总3页 (文件大小:209K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
90W Single Output Switching Power Supply
LPF-90 series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 91%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class
power unit, no FG
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
M
M
SELV
IP67
SPECIFICATION
MODEL
LPF-90-15
LPF-90-20
LPF-90-24
LPF-90-30
LPF-90-36
LPF-90-42
LPF-90-48
LPF-90-54
36V
42V
DC VOLTAGE
15V
20V
24V
30V
48V
54V
21.6 ~ 36V
2.5A
25.2 ~ 42V
2.15A
CONSTANT CURRENT REGION Note.4 9 ~ 15V
12 ~ 20V
4.5A
14.4 ~ 24V
3.75A
90W
18 ~ 30V
3A
28.8 ~ 48V
1.88A
32.4 ~ 54V
1.67A
RATED CURRENT
RATED POWER
5A
90W
90.3W
200mVp-p
4.0%
75W
90W
90W
90.24W
200mVp-p
4.0%
90.18W
200mVp-p
4.0%
200mVp-p
4.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE TOLERANCE Note.3 4.0%
150mVp-p
4.0%
150mVp-p
4.0%
200mVp-p
4.0%
OUTPUT
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
0.5%
1.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
0.5%
Note.7 2000ms, 80ms / 115VAC at full load
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
16ms/230VAC
Note.5 90 ~ 305VAC
47 ~ 63Hz
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
PF>0.97/115VAC, PF>0.96/230VAC, PF>0.95/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
INPUT
90%
91%
91%
91%
91%
89%
91%
90.5%
0.5A / 230VAC
0.95A / 115VAC
0.4A / 277VAC
COLD START 70A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
47 ~ 53V
18 ~ 21V
Protection type : Shut down o/p voltage, re-power on to recover
90 10 (RTH2)
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
54 ~ 60V
59 ~ 65V
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
UL8750, EN61347-1, EN61347-2-13 independent, J61347-1, J61347-2-13, IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC
SAFETY &
EMC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
EMC IMMUNITY
MTBF
301.6Khrs min. MIL-HDBK-217F (25
161*61*36mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.7Kg;20pcs/15Kg/0.73CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:LPF-90-SPEC 2011-07-28
90W Single Output Switching Power Supply
LPF-90 series
Mechanical Specification
Case No.LPF-90A
Unit:mm
161
4
300 20
300 20
AC/L(Brown)
AC/N(Blue)
+V(Red)
-V(Black)
SJTW 18AWG 2C
T case
SVT 18AWG 2C
91
4
T case: Max. Case Temperature.
Block Diagram
fosc : 100KHz
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
+V
-V
I/P
CIRCUIT
O.L.P.
O.T.P.
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
90
80
70
60
50
40
100
80
230VAC
Input only
60
40
20
(HORIZONTAL)
-40
-25 -10
0
15
30
50
60
70
90 100 125 135 145 155 165 175 180 200 230 305
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (V) 60Hz
File Name:LPF-90-SPEC 2011-07-28
90W Single Output Switching Power Supply
LPF-90 series
Power Factor Characteristic
Constant Current Mode
1
0 . 9 9
0 . 9 8
0 . 9 7
0 . 9 6
0 . 9 5
2 7 7 V A C
2 3 0 V A C
1 1 5 V A C
5 0 %
6 0 %
7 0 %
8 0 %
9 0 %
1 0 0 %
(90W)
LOAD
EFFICIENCY vs LOAD (48V Model)
LPF-90 series possess superior working efficiency that up to 91% can be reached in field applications.
93
92
91
90
277VAC
89
230VAC
88
115VAC
87
86
85
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
100
Constant
Current area
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
File Name:LPF-90-SPEC 2011-07-28
相关型号:
©2020 ICPDF网 联系我们和版权申明