ENC-240-12 [MEANWELL]
240W Programmable Desktop Type Battery Charger;型号: | ENC-240-12 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 240W Programmable Desktop Type Battery Charger 电池 |
文件: | 总5页 (文件大小:107K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
240W Programmable Desktop Type Battery Charger
ENC-240 series
UL60950-1
IEC60950-1
■ Features
■ Applications
ꢀCharger for lead-acid batteries (flooded, Gel and AGM)
and li-ion batteries (lithium iron and lithium manganese)
ꢀBuilt-in 3 stage programmable charging curve
ꢀUniversal AC input / Full range
ꢀRadio system backup solution
ꢀElectric scooter charger
ꢀSurveillance system
ꢀBuilt-in active PFC function
ꢀFanless design, cooling by free air convection
ꢀBuilt-in temperature compensation function
ꢀProtection: Short circuit / Over voltage /Over temperature /
Battery under voltage / Battery over voltage / Battery reverse
polarity protection
ꢀ3 years warranty
■ Description
ENC-240 is a single output 240W AC/DC desktop type charger with 3 stage charging curve. In addition to
the embedded pre-defined charging curves, the default curve is programmable and thus able to accommodate
different types of batteries, such as lead-acid batteries (gel, flooded and AGM) and li-ion batteries
(lithium iron and lithium manganese). With the rugged mechanical design along with the high efficiency
circuitry, ENC-240 operates for the ambient temperature range -30~+70℃ under free air convection.
■ Model Encoding
ENC -240 - 24
Nominal voltage
Rated wattage
Series name
File Name:ENC-240-SPEC 2017-02-13
240W Programmable Desktop Type Battery Charger
ENC-240 series
SPECIFICATION
MODEL
ENC-240-12
ENC-240-24
ENC-240-48
BOOST CHARGE VOLTAGE(Vboost)(default) 14.4V
28.8V
27.6V
18 ~ 30V
8A
57.6V
55.2V
36 ~ 60V
4A
FLOAT CHARGE VOLTAGE(Vfloat)(default) 13.8V
CHARGE VOLTAGE RANGE Note.3 9 ~ 15V
OUTPUT CURRENT(CC) (default) 16A
OUTPUT
RATED POWER
230.4W
230.4W
230.4W
RECOMMENDED BATTERY
CAPACITY (AMP HOURS) Note.4
60 ~ 170AH
30 ~ 85AH
15 ~ 45AH
LEAKAGE CURRENT FROM
BATTERY (Typ.)
<1mA
VOLTAGE RANGE
Note.5 90 ~ 264VAC
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load
INPUT
91%
92%
93%
2.5A/115VAC
1.25A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
COLD START 75A at 230VAC
<3.5mA / 240VAC
SHORT CIRCUIT
Note.6
Protection type : Shut down O/P voltage, re-power on to recover
15.5 ~ 18.2V 31 ~ 36.5V
62.1 ~ 72.9V
OVER VOLTAGE
Note.7
PROTECTION
FUNCTION
ENVIRONMENT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
By internal fuse
REVERSE POLARITY
OVER TEMPERATURE
Shut down O/P voltage, recovers automatically after temperature goes down
By NTC
TEMPERATURE COMPENSATION
WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH non-condensing
0.05%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC60950-1, UL60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Conducted
Radiated
Standard
Test Level / Note
EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B
EN55032 (CISPR32) / FCC PART15 (CISPR22) Class B
EMC EMISSION
Harmonic Current
Voltage Flicker
EN55024
EN61000-3-2
EN61000-3-3
-----
-----
SAFETY &
EMC
(Note 8)
Parameter
ESD
Standard
Test Level / Note
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Level 2, 3V/m
Radiated
EFT / Burst
Surge
Level 2, 1KV
EMC IMMUNITY
Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Level 2, 3Vrms
Conducted
Magnetic Field
Level 1, 1A/m
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
155.8K hrs min. MIL-HDBK-217F (25℃)
MTBF
OTHERS
NOTE
DIMENSION
PACKING
192*178*45.5mm (L*W*H)
1.23Kg; 10pcs/13.3Kg /1.34CUFT
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.
4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
7. Each model incorporates a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant
Voltage stage whereas 115% of Vfloat over Float stage.
8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:ENC-240-SPEC 2017-02-13
240W Programmable Desktop Type Battery Charger
ENC-240 series
Block Diagram
POLARITY
REVERSE
PROTECTION
+V
RECTIFIERS
&
FILTER
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
PFC
I/P
FG
CIRCUIT
-V
O.C.P.
O.L.P.
DETECTION
CIRCUIT
PWM
CONTROL
PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
90
80
70
60
50
40
100
80
60
40
20
-30
0
10
20
30
40
50
60
70 (HORIZONTAL)
90 100 115 120 140 160 180 190 200 220 240 264
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE (℃)
File Name:ENC-240-SPEC 2017-02-13
240W Programmable Desktop Type Battery Charger
ENC-240 series
Function Manual
1.Charging Curve
※ This series provides a 3 stage charging. The default curve is programmable, whereas other pre-defined curves can be
activated by the means of the DIP switch; please refer to the table below and the Mechanical Specification.
※ To accommodate the parameters of the charging curve, SBP-001, the smart battery charging programmer designed by
MEAN WELL, and a personal computer are needed. Please contact MEAN WELL for details.
◎ Default 3 stage charging curve
Start
Vboost
Vfloat
Charge Voltage
100% CC
10% CC
Charge Current
Constant Current Constant Voltage
stage 1 stage 2
Float
stage 3
Green
Orange
Color of LED
Status Indicator
◎ Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese).
◎ Embedded 3 stage charging curve
MODEL Description
Default, programmable
CC(default)
V
boost
Vfloat
14.4
14
13.8
13.6
13.4
13.5
27.6
27.2
26.8
27
Pre-defined, gel batter
12V
24V
48V
16A
Pre-defined, flooded battery
Pre-defined, AGM battery
Default, programmable
Pre-defined, gel battery
Pre-defined, flooded battery
Pre-defined, AGM battery
Default, programmable
Pre-defined, gel battery
Pre-defined, flooded battery
Pre-defined, AGM battery
14.2
14.5
28.8
28
8A
4A
28.4
29
57.6
56
55.2
54.4
53.6
54
56.8
58
2. Front Panel LED Indicators & Corresponding Signal at Function Pins
LED
Description
Green
Orange
Float (stage 3)
Charging (stage 1 or stage 2)
File Name:ENC-240-SPEC 2017-02-13
240W Programmable Desktop Type Battery Charger
ENC-240 series
Mechanical Specification
Case No. 252 Unit:mm
4.3
192
45.5
LED
TB1
1
2
3
4
47.5
DIP
SW
CN31
2-M3 L=5
CN31
1 2
1
5
2
6
SWITCH
INLET
Connector Pin No. Assignment (CN31) :
HRS DF11-6DP-2DS or equivalent
Pin No. Assignment Mating Housing
Terminal Pin No. Assignment (TB1):
Pin No. Assignment
Terminal
1,2
3,4
+V
-V
1
2
3
4
5
6
Prog- +3.3V
Prog- GND
Prog- RX
Prog- TX
RTH+
HRS DF11-6DS HRS DF11-**SC
or equivalent
or equivalent
DIP SW:
1
2
Description
RTH-
OFF
ON
OFF
OFF
ON
Default, programmable
Pre-defined, Gel battery
Pre-defined, flooded battery
Pre-defined, AGM battery
OFF
ON
ON
File Name:ENC-240-SPEC 2017-02-13
相关型号: